Portable Optical Dissolved Oxygen Meter (DDOPRO10)
WhatsApp Order
Portable Optical Dissolved Oxygen Meter (DDOPRO10), rugged handheld instrument using optical/fluorescence sensor technology for low-maintenance on-site DO analysis. Measures DO concentration (0.00–20.00 mg/L) and percent saturation (0.0–200.0%) with automatic compensation for temperature, barometric pressure, and manual salinity. 3.5-inch TFT color screen with user-friendly UI; stores up to 3,000 data sets for GLP-compliant documentation; rechargeable lithium battery with Type-C port. Includes optical DO probe (DODO01‑3M) with POM shell and stainless steel protection sleeve, hard carrying case, and charging cable. Optical technology eliminates electrolyte refills, membrane cap replacements, polarization times, and frequent calibrations; measures without sample stirring. Fast <15-second response. Ideal for monitoring dissolved oxygen in purified water systems (WFI, dialysis water), wastewater aeration, and pharmaceutical production.For the patient, this rigorous monitoring helps ensure that water used in dialysis and other medical treatments meets stringent safety standards, preventing potential harm from improperly treated water. The meter provides quick (<15 second response), reliable, and verifiable results for any application requiring critical DO measurement.
Categories: LABORATORY EQUIPMENT AND SUPPLIES, Analyzers
Tags: Dialysis Water Monitoring, DLAB Portable Optical Dissolved Oxygen Meter - Single Parameter (DDOPRO10), DO Measurement, Fluorescence DO Sensor, Optical DO Meter, Pharmaceutical Water QC, Portable Optical Dissolved Oxygen Meter - Single Parameter (DDOPRO10), Water Quality Testing
Description
Portable Optical Dissolved Oxygen Meter (DDOPRO10)
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Rapid, Maintenance-Free Dissolved Oxygen Measurement for Water Quality Surveillance
-
Primary Use: Provides a portable, single-parameter meter utilizing optical/fluorescence dissolved oxygen (DO) technology to measure DO concentration (0.00~20.00 mg/L) and oxygen saturation (0.0~200.0%) in aqueous samples, with integrated automatic temperature and barometric pressure compensation, as well as manual salinity compensation for accurate readings .
-
How it helps: For the clinical laboratory scientist and water quality specialist, the DDOPRO10’s optical technology requires no electrolyte or membrane cap replacement, eliminates long polarization times and frequent calibration, and offers a rapid response time (<15 seconds) . The 3.5-inch TFT color screen, IP57 dustproof/waterproof rating, and rechargeable lithium battery (charged via Type-C port) make it ideal for field use . For the patient, accurate measurement of dissolved oxygen in water used for dialysis, pharmaceutical production, or other medical processes is a critical parameter for ensuring water quality and preventing adverse events related to improper water treatment .
2. Monitoring of Critical Water Systems in Healthcare Facilities
-
Primary Use: Designed to monitor dissolved oxygen levels in purified water systems, water-for-injection (WFI) loops, and pharmaceutical process water to assess system integrity, microbial control, and oxidation-reduction conditions .
-
How it helps: For the facility water quality manager and infection control officer, the Portable Optical Dissolved Oxygen Meter – Single Parameter (DDOPRO10) fluorescence-based probe consumes no oxygen during measurement, ensuring stability in low-flow or stagnant water systems . The durable POM (polyoxymethylene) shell electrode with stainless steel protection/weighting sleeve is suitable for use in harsh environments . For the patient, continuous and accurate monitoring of water treatment processes helps prevent healthcare-associated infections linked to waterborne pathogens and ensures the chemical compatibility of water used in medical device processing .
SECONDARY & SUPPORTIVE USES
1. Pharmaceutical Bioprocess Support: Verifies DO levels in small-scale bioreactors, shaker flasks, and fermentation systems during pharmaceutical R&D.
2. Wastewater Treatment Monitoring: Measures dissolved oxygen in hospital wastewater treatment systems to assess treatment efficacy and aeration basin performance .
3. Aquaculture and Zebrafish Facility Management: Used to monitor dissolved oxygen levels in aquatic animal housing facilities within research institutions .
4. Boiler Water and Steam Generation Monitoring: Checks scavenger residuals and corrosion potential in boiler water systems for hospital facilities.
5. Environmental and Surface Water Monitoring: Portable format is ideal for field studies measuring DO in natural water bodies to assess ecosystem health .
6. Food and Beverage Quality Control: Used in the production of beverages (e.g., soft drinks, beer) and packaged foods where dissolved oxygen levels affect product shelf-life and quality.
7. Educational and Laboratory Training: Serves as a practical teaching tool for demonstrating modern optical sensor technology and water quality measurement principles.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A portable, battery-operated meter using an optical (fluorescence-based) dissolved oxygen sensor. It is a single-parameter instrument for measuring DO concentration and saturation, with integrated temperature measurement and automatic/built-in compensation mechanisms .
-
Designation: Portable Optical Dissolved Oxygen Meter - Single Parameter (DDOPRO10), DLAB Portable Optical Dissolved Oxygen Meter - Single Parameter (DDOPRO10), Portable Optical DO Meter, Single-Parameter DO Analyzer .
-
Key Components:
• Instrument Meter: Portable housing with a 3.5-inch TFT LCD color screen, UI interface, and Type-C charging port .
• Optical DO Probe: DODO01-3M optical dissolved oxygen electrode with 3-meter cable, POM shell, and stainless steel protection/weighting sleeve .
• Power Supply: Rechargeable lithium battery (pre-installed) and charging cable .
• Accessories: Hard carrying case (33 × 27.2 × 8.2 cm) for transport and storage .
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Measurement Range: Dissolved oxygen: 0.00~20.00 mg/L; Oxygen saturation: 0.0~200.0% .
-
Measurement Accuracy: DO: ±0.20 mg/L .
-
Temperature Measurement Range: 0.0~100.0°C / 32.0~212.0°F (probe limit), Display range up to 135.0°C .
-
Temperature Accuracy: ±0.2°C .
-
Compensation Methods: Automatic barometric pressure compensation (0~200.0 kPa), automatic temperature compensation (0.0~50.0 °C), and manual salinity compensation (0~45 ppt) .
-
Display: 3.5-inch TFT LCD color screen .
-
Data Storage: 3000 data sets, including parameter, measured value, temperature, and timestamp .
-
Power Supply: Rechargeable lithium battery, charged via Type-C port .
-
Protection Class: IP57 (dustproof and waterproof) .
-
Dimensions (Carrying Case): 33 × 27.2 × 8.2 cm .
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Display: High-resolution color TFT screen for superior visibility and user experience .
-
User Interface: New UI design and intelligent operation system with functions for timed measurement, data locking, and parameter setting .
-
Sensor Technology: Fluorescence/optical technology — does not consume dissolved oxygen, ensuring measurement stability and no stirring requirement .
-
Connectivity: Type-C charging port, compliant with modern electronics standards .
-
Electrode Design: POM shell electrode, rugged and durable; stainless steel protection/weighting sleeve suitable for harsh environments . No electrolyte or membrane cap replacement needed; no long polarization time or frequent calibration required .
-
Response Time: <15 seconds .
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: IVD (In Vitro Diagnostic) preparatory equipment; complies with GLP standards for data management .
-
Waterproof Rating: IP57, providing reliable operation in humid or wet field conditions .
-
Power Management: Built-in low-power management, automatic power-off, and power failure protection functions .
-
Software Upgradeable: Supports software upgrades for maintaining instrument performance .
-
Warranty: 2-year manufacturer warranty (electrode warranty may be excluded) .
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store the meter in a clean, dry place. The optical DO probe should be stored with the sensor cap protected from light and extreme temperatures; do not allow the sensing element to dry out completely (follow manufacturer storage instructions) .
-
Cleaning: Rinse the probe with distilled water after each use. Wipe the meter body with a soft, damp cloth using a mild detergent. Do not submerge the meter body.
-
Calibration: Calibrate the meter before use, typically in water-saturated air (100% humidity) or using a zero-oxygen solution . The optical technology reduces the frequency of calibration compared to polarographic probes .
-
Data Export: Connect to PC using software to configure parameters and export recorded data as CSV files for analysis .
-
Maintenance: No electrolyte solution or membrane cap replacement is required, dramatically reducing maintenance compared to polarographic DO meters .
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: On-site or laboratory measurement of dissolved oxygen concentration to assess water quality, monitor biological processes, and support environmental compliance in water treatment, aquaculture, pharmaceutical, and food/beverage facilities .
-
Clinical Role: Used in hospital engineering and facility management teams for water quality surveillance of dialysis water systems, purified water loops, pharmaceutical process water, and wastewater treatment plants, as well as in pharmaceutical QA/QC for water system validation .
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Electrical Safety: Do not immerse the meter in liquid, despite its IP57 rating. Ensure the Type-C port is dry before charging. Avoid pulling the probe cable violently .
-
Probe Handling: The optical probe is delicate. Do not touch the optical sensing element with sharp objects or abrasives. Do not use the probe in solutions containing organic solvents that might damage the sensor coating .
-
Optical Sensor Cap: The sensor cap has a finite lifespan (typically 1-2 years). Replace the sensor cap as recommended by the manufacturer to maintain accuracy .
-
Calibration Intervals: Calibrate the meter periodically as per facility protocol, especially when high accuracy is required for critical water systems . Optical technology requires less frequent calibration than polarographic probes .
-
Stirring Not Required: The optical probe does not consume oxygen and does not require sample stirring, simplifying field measurements .
2. FIRST AID MEASURES
-
Sample Splash: If a biological sample splashes into the eyes, flush with water for 15 minutes and seek medical attention; if on skin, wash with soap and water .
-
Electrical Malfunction: If the meter shows signs of electrical malfunction, disconnect it from any power source and contact service personnel .
3. FIRE FIGHTING MEASURES
-
Flammability: The plastic housing, cable, and case are combustible; may melt or burn if exposed to flame or high heat .
-
Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires .
-
Fire Response: Disconnect the meter from the charging cable; do not use water on an electrical fire .
Related products
Anti-Streptol Olysin O Titer (ASOT)
$24.23
Anti-Streptol Olysin O Titer (ASOT) is a quantitative or semi-quantitative serological test (latex agglutination, turbidimetry, nephelometry, or ELISA) for detecting antibodies against streptolysin O, an exotoxin produced by Group A Streptococcus. Elevated or rising titers indicate recent streptococcal infection and are essential for diagnosing post-streptococcal sequelae including acute rheumatic fever (Jones criteria) and post-streptococcal glomerulonephritis. The test requires serum samples; acute and convalescent (2-4 weeks apart) with fourfold rise confirms recent infection. Reference range typically <200-250 Todd units/mL (adults), varies by age and population. Primary clinical applications include diagnosis of Group A streptococcal infections, acute rheumatic fever evaluation, post-streptococcal glomerulonephritis diagnosis, differentiation of acute vs. past infection, evaluation of unexplained arthritis or carditis, pediatric inflammatory conditions (PANDAS), and monitoring disease activity in rheumatic fever. Critical safety precautions include proper timing of acute and convalescent samples, awareness of false negatives/positives, clinical correlation for diagnosis, and standard biohazard precautions. Essential test for rheumatology, nephrology, cardiology, and infectious disease practice.
Centrifuge Tubes
$1.00
Centrifuge Tubes are specialized disposable containers (polypropylene) designed to withstand high centrifugal forces (up to 30,000 x g) for separating biological fluids based on density. Available in microcentrifuge sizes (0.2-2.0 mL), conical tubes (15 mL, 50 mL), and larger volumes (100-500 mL). Features include leak-proof screw caps with O-rings (conical tubes), snap caps (microcentrifuge tubes), graduated volume markings, writing areas, and sterile/non-sterile options. Certified RNase/DNase-free, pyrogen-free, and autoclavable. Primary clinical applications include blood component separation (serum/plasma), urine sediment preparation, microbiology sample concentration, molecular biology (DNA/RNA extraction), cell culture processing, protein/enzyme analysis, and viral load testing. Critical safety precautions include never exceeding maximum RCF rating, proper balancing by weight, secure cap tightening, inspection for cracks, and disposal as biohazardous waste. Essential consumable in every clinical, research, and industrial laboratory.
Cover Glass
$1.00
Cover Glass (coverslips) are thin, transparent glass or plastic squares (e.g., 18×18 mm, 22×22 mm) or rectangles (22×30 mm, 24×50 mm) used to cover specimens on microscope slides for microscopic examination. Available in thickness No. 1 (0.13-0.16 mm) and No. 1.5 (0.16-0.19 mm) for optimal microscopy. Made from optical glass with high light transmission (>90%), refractive index 1.52 matching immersion oil. Packaged in boxes of 100-1000, interleaved with paper to prevent scratching. Primary clinical applications include covering blood films for manual differential counts and malaria diagnosis, wet mount preparations of urine sediment and vaginal secretions, histopathology and cytology slides, Gram-stained bacterial smears, semen analysis, KOH preparations for fungal elements, and India ink preparations for Cryptococcus. Critical safety precautions include handling with forceps (sharp edges), disposing of broken coverslips in sharps containers, avoiding fingerprints on optical surface, and proper disposal of biohazard-contaminated coverslips. Essential consumable in every clinical laboratory performing microscopy.
ESR Tubes Glass
$1.00
ESR Tubes Glass are specialized glass tubes (300 mm length, 2.55 mm bore diameter, graduated 0-200 mm in 1 mm intervals) meeting ICSH and CLSI Westergren specifications for measuring erythrocyte sedimentation rate, a non-specific marker of inflammation. Used with citrated or diluted EDTA blood, filled to exactly 200 mm, placed vertically in Westergren stand, and read at 60 minutes. Primary clinical applications include determination of ESR for diagnosing and monitoring inflammatory conditions (infections, autoimmune disorders, malignancies), monitoring disease activity in rheumatoid arthritis, assessment of temporal arteritis and polymyalgia rheumatica, evaluation of infection and inflammatory response, screening for occult inflammatory conditions, and monitoring chronic inflammatory diseases (SLE, IBD, vasculitis). Critical safety precautions include handling glass tubes carefully to avoid breakage (sharps hazard), proper disposal in sharps containers as biohazardous waste, ensuring vertical alignment and constant temperature (18-25°C), reading at exactly 60 minutes, and avoiding air bubbles and vibration. Essential consumable for reference Westergren ESR testing in clinical laboratories.
Finecare Analyzer
$1.00
The Finecare Analyzer is a Class II medical device (FDA-cleared, CE-marked) fluorescence immunoassay system manufactured by Wondfo Biotech for quantitative detection of cardiac markers (troponin I, CK-MB, myoglobin), inflammatory markers (CRP, procalcitonin), thyroid hormones (TSH, FT3, FT4), diabetes markers (HbA1c), reproductive hormones (LH, FSH, prolactin), tumor markers (AFP, CEA, PSA), and infectious disease markers. Features include time-resolved fluorescence technology, color touchscreen interface, built-in printer (select models), USB/Ethernet connectivity, and internal rechargeable battery for portable use. Test time 3-15 minutes, sample volume 50-100 µL (whole blood, serum, plasma). Primary clinical applications include rapid diagnosis of acute myocardial infarction in chest pain patients, early detection of sepsis and bacterial infections, thyroid disorder diagnosis and monitoring, long-term glycemic control assessment in diabetes, fertility and reproductive health evaluation, cancer screening and surveillance, and infectious disease testing in endemic and clinical settings. Critical safety precautions include proper test cartridge storage (2-8°C), regular quality control, biohazard safety protocols, and operator training. Essential point-of-care testing system for hospitals, clinics, and remote healthcare facilities requiring rapid, quantitative results.
Microscope Bulb
$1.00
A Microscope Bulb is a specialized halogen or LED lamp that serves as the essential illumination source for clinical and laboratory microscopes. Providing the bright, stable, and color-corrected light required for diagnostic visualization of specimens, it is a critical consumable component. Its technical specifications—voltage, wattage, base type, and filament alignment—must precisely match the microscope model. Proper handling (using gloves to avoid oil contamination) and adherence to safety protocols (allowing cooling, disconnecting power) are crucial for safe replacement and optimal bulb lifespan. Maintaining spares is vital to prevent operational downtime in diagnostic laboratories.
Mission Plus HB Machine
$1.00
The Mission Plus HB Machine is a portable, battery-operated hemoglobin meter (Class II medical device, FDA-cleared/CE-marked) using photometric technology to measure hemoglobin concentration in capillary or venous blood within 5-15 seconds. Features include backlit LCD display, memory storage for 100-500 results, simple one-button operation, and disposable single-use cuvettes (5-20 µL sample volume). Accuracy ±0.3 g/dL compared to reference methods, measurement range 4-24 g/dL. Primary clinical applications include rapid anemia screening in outpatient clinics, preoperative assessment, antenatal care and maternal health monitoring, malaria-endemic region screening, chronic disease management (CKD, IBD, cancer), nutritional assessment and intervention programs, and blood donor screening. Critical safety precautions include single-use lancets, proper hand hygiene, correct sample application, quality control with control solutions, proper cuvette storage (protect from heat, light, humidity), and never using expired cuvettes. Essential point-of-care device for hemoglobin testing in diverse healthcare settings.
VDRL Test For Syphilis
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties