MicroPette Plus Fully Autoclavable Fixed Volume Mechanical Pipette
WhatsApp Order
The MicroPette Plus Fully Autoclavable Fixed Volume Mechanical Pipette is a precision single‑channel manual pipette engineered for error‑free, high‑accuracy liquid handling in standardised diagnostic workflows. Pre‑set to a fixed volume, it completely eliminates the risk of operator‑induced volume adjustment errors, ensuring that every well or tube receives exactly the intended reagent volume.
Available in twelve fixed volumes from 5 μL to 5000 μL, the pipette is individually calibrated to ISO 8655 and supplied with a traceable calibration certificate. Its ergonomic design features a light‑touch plunger, relaxed finger rest, and quick‑release tip ejector, reducing user fatigue during extended pipetting sessions and allowing one‑handed, hygienic tip changes.
Constructed from high‑quality heat‑ and chemical‑resistant polymers, the entire pipette can be fully autoclaved at 121 °C for 20 minutes without disassembly, and it also withstands UV disinfection and harsh decontamination agents – ideal for aseptic microbiology, cell culture, and sterility assurance laboratories. After autoclaving, the pipette must be cooled and dried for at least 12 hours before re‑use.
For the clinical laboratory scientist, the MicroPette Plus Fixed Volume Pipette delivers the consistent, traceable accuracy required for high‑throughput ELISA, PCR setup, pharmaceutical QC, and industrial testing. For the patient, its standardised, error‑free operation ensures that diagnostic results are reproducible, reliable, and delivered with faster turnaround times, supporting timely and appropriate clinical decision‑making.
Categories: LABORATORY EQUIPMENT AND SUPPLIES, Pipettes, Dispensers, and Lab Glassware
Tags: Autoclavable Laboratory Equipment, Autoclavable Pipette, Blood Bank Pipetting, Cell Culture Pipette, Clinical Diagnostics, DLAB Pipette, ELISA Pipette, Ergonomic Pipette, Fixed Volume Pipette, Fixed Volume Transfer, Fully Autoclavable Pipette, ISO 8655 Pipette, ISO8655 Pipette, Laboratory Pipette, Manual Pipette, Mechanical Pipette, MicroPette Plus, PCR Master Mix Addition, PCR Sample Preparation, Positive Stop Pipette, Quality Control Pipette, Repetitive Pipetting Tool, Single-Channel Pipette, Standard Curve Preparation, Sterilisable Pipette
Description
MicroPette Plus Fully Autoclavable Fixed Volume Mechanical Pipette
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Fixed-Volume Precision for Standardized Diagnostic Assays
-
Primary Use: Provides a single‑channel, fully autoclavable mechanical pipette pre‑set to a fixed volume, eliminating the risk of user‑adjustment errors. Available in twelve fixed volumes from 5 μL to 5000 μL, it is designed for high‑accuracy, repeatable liquid handling in reference laboratories, diagnostic kit manufacturing, and routine clinical testing.
-
How it helps: For the clinical laboratory scientist and molecular biologist, the fixed‑volume design removes the potential for operator‑induced volume changes, thereby improving the reproducibility of critical diagnostic workflows such as ELISA, PCR, and clinical chemistry. Because the volume cannot be altered, the risk of protocol deviation is eliminated, ensuring that each well receives exactly the intended reagent volume. For the patient, this consistency reduces well‑to‑well variability in diagnostic tests, supporting reliable detection of infectious diseases, genetic markers, and therapeutic drug levels, while facilitating faster and more accurate clinical decision‑making.
2. Complete Autoclavability for Aseptic Microbiology and Cell Culture
-
Primary Use: The entire pipette is manufactured from high‑quality heat‑resistant materials that permit fully automatic steam sterilisation at 121 °C, 1 atm for 20 minutes without disassembly; it also withstands UV disinfection and harsh chemicals.
-
How it helps: For the cell‑culture specialist, public health microbiologist, and sterility assurance laboratory, this one‑step autoclaving capability eliminates cross‑contamination risks between sensitive cell lines, viral isolates, or microbial cultures. The pipette can be autoclaved without special preparation, and after cooling and drying for 12 hours it is ready for immediate aseptic use. For the patient undergoing cell‑based therapies, vaccine testing, or sterility release assays, this rigorous sterilisation protects specimens from adventitious agents, ensuring the integrity of diagnostic results and the safety of biological products.
3. Ergonomic Design for Prolonged, Repetitive Pipetting
-
Primary Use: Features a light‑touch plunger, relaxed finger rest, and overall user‑friendly shape that minimises hand and wrist strain during extended pipetting sessions. The quick‑release tip ejector enables one‑handed, fatigue‑free tip changes.
-
How it helps: For the high‑throughput laboratory staff and industrial processing facility, the ergonomic design reduces the risk of repetitive strain injury (RSI) while maintaining consistent technique. The low‑force operation and comfortable grip allow operators to work for longer periods without compromising accuracy. For the patient, a less fatigued workforce maintains error‑free sample handling, directly contributing to the reliability and reproducibility of their diagnostic results.
4. Quick‑Release Tip Ejector and Clear Digital Display
-
Primary Use: A quick‑release button allows safe, hygienic one‑handed tip removal. The fixed volume setting is displayed in a digital window, providing unambiguous visual confirmation of the pipette’s capacity.
-
How it helps: For the bench scientist and laboratory manager, the instantaneous tip ejection speeds up workflow, while the digital display prevents confusion over which pipette is in hand – a frequent source of error in busy laboratories. For the patient, the combination of rapid tip changes and clear volume identification helps maintain high throughput and reduces the risk of volume‑related mistakes.
5. Effortless User Calibration and Sustained Accuracy
-
Primary Use: Each pipette can be calibrated on‑site using standard laboratory tools; it may also be recalibrated online via the manufacturer’s website. Every MicroPette Plus is supplied with an individual calibration certificate in accordance with ISO 8655.
-
How it helps: For the quality assurance manager and laboratory technician, in‑house calibration reduces expensive downtime and eliminates the need to send pipettes off‑site for servicing. The ISO‑certified certificate and documented traceability support regulatory compliance (GLP, CLIA, CAP). For the patient, regular, effortless maintenance ensures that the pipette remains in optimal working order, sustaining diagnostic accuracy over thousands of pipetting cycles.
6. High‑Temperature and Chemical Resistance
-
Primary Use: Constructed from innovative, heat‑resistant polymers that withstand repeated autoclaving and exposure to aggressive laboratory chemicals, alcohols, and decontaminating agents.
-
How it helps: For the laboratory manager and safety officer, the pipette’s chemical resistance and thermal stability guarantee a long service life even in demanding environments. The ability to withstand harsh decontamination agents supports rigorous infection control protocols. For the patient, a durable, chemically resistant instrument reduces the risk of material degradation that could shed particles into samples or cause unnoticed volume errors.
SECONDARY & SUPPORTIVE USES
1. ELISA and immunoassay reagent addition – Precisely dispense antibodies, wash buffers, and substrates into 96‑well plates using a fixed volume that is optimised for the assay protocol.
2. PCR and qPCR master mix distribution – Consistently dispense master mix, primers, and probes into reaction wells with zero volume‑adjustment error.
3. DNA and RNA extraction – Transfer binding buffers, wash buffers, and elution solutions in defined, reproducible volumes across multiple samples during nucleic acid purification.
4. Clinical chemistry sample preparation – Add fixed volumes of patient serum, plasma, or urine to reagents for routine chemistry panels and metabolite analysis.
5. Pharmaceutical quality control – Transfer test solutions, dissolution media, and QC samples with unvarying accuracy during drug product analysis.
6. Blood bank and transfusion medicine – Load red‑cell suspensions, antisera, or other reagents for ABO/Rh typing and compatibility testing.
7. Food safety testing – Prepare food and environmental samples for PCR‑based pathogen detection (e.g., Salmonella, Listeria, E. coli O157:H7) using standardised volumes.
8. Veterinary diagnostic testing – Process animal samples (blood, serum, tissue) for infectious disease surveillance, vaccine‑response monitoring, and genetic screening.
9.Environmental monitoring – Transfer fixed volumes of water, soil, and wastewater samples into test vessels for microbial analysis and water‑quality monitoring.
10. Forensic DNA analysis – Load PCR products and DNA extracts for STR analysis in forensic casework and paternity testing.
11. Academic teaching laboratories – Serve as a consistent, introductory manual pipette for training students in precise liquid‑handling techniques.
12. Next‑generation sequencing (NGS) library preparation – Dispense adapters, indexes, and master mixes where microliter precision is critical.
13. Drug discovery and high‑throughput screening – Dispense compounds, cells, and assay reagents into 96‑well plates for pharmaceutical research.
14. Protein quantification assays – Dispense Bradford, BCA, or other protein assay reagents into standard cuvettes or microplates using an optimised fixed volume.
15. Cell culture media and buffer preparation – Transfer defined volumes of sterile media, buffers, and supplements under aseptic conditions using an autoclavable instrument.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A manual, single‑channel, fully autoclavable mechanical pipette with a pre‑set fixed volume.
-
Designation: MicroPette Plus Fully Autoclavable Fixed Volume Mechanical Pipette, DLAB MicroPette Plus Fixed Volume Pipette.
-
Key Components:
-
Digital Volume Display: Clear window showing the fixed volume capacity.
-
Quick‑Release Tip Ejector: One‑button ejection for hygienic, one‑handed tip changes.
-
Finger Rest: Relaxed, ergonomic support.
-
Material Construction: High‑quality, heat‑resistant, chemically resistant polymer.
-
Tip Cone: Universal tip cone compatible with most standard pipette tips.
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Available Fixed Volumes: 5 μL, 10 μL, 20 μL, 25 μL, 50 μL, 100 μL, 200 μL, 250 μL, 500 μL, 1000 μL, 2000 μL, 5000 μL.
-
Example Accuracy and Precision (5 μL Model):
-
Systematic Error (Accuracy): ±0.065 μL (±1.3%).
-
Random Error (Precision/CV): ±0.06 μL (±1.2%).
-
Sterilisation: Fully autoclavable at 121 °C (250 °F), 1 atm for 20 minutes without disassembly; also compatible with UV disinfection and resistant to harsh chemicals.
-
Compliance & Certification: Calibrated in accordance with ISO 8655; each pipette supplied with an individual calibration certificate; CE marked; manufactured under ISO 9001:2008 and ISO 13485:2003 quality systems.
-
Calibration: User‑adjustable using standard tools; online recalibration available via the manufacturer’s website.
-
Tip Compatibility: Compatible with most universal pipette tips on the market.
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Operation: Manual, thumb‑activated plunger with a light‑touch action.
• Volume Adjustment: None (fixed volume design); volume is factory‑set and cannot be altered by the user.
• Tip Ejection: Quick‑release button for safe, one‑handed tip removal.
• Finger Rest: Relaxed, ergonomic finger support for comfortable extended use.
• Portability: Compact, lightweight design for benchtop use and storage.
• Maintenance: User‑replaceable components; calibration tools included; can be maintained with standard laboratory tools.
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: General laboratory equipment for in vitro diagnostic (IVD) use; manufactured under ISO 9001:2008 and ISO 13485:2003 certified processes.
• Sterilisation Safety: Fully autoclavable without disassembly; after autoclaving, cool and dry for at least 12 hours before use.
• Chemical Resistance: Constructed from materials that resist a wide range of laboratory chemicals, solvents, and acids.
• Quality Compliance: Each pipette passes quality control testing, including gravimetric verification with distilled water at 22 °C, and is supplied with an individual ISO 8655 calibration certificate.
• Tip Seal Verification: Proper tip seating ensures a reliable seal, preventing leakage and inaccurate volume delivery.
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store upright in a pipette stand to prevent tip‑cone contamination.
• Cleaning: Wipe external surfaces with 70% isopropyl alcohol or mild detergent solution; do not immerse the pipette in liquid.
• Autoclaving: Pipette can be autoclaved without preparation. After autoclaving, allow to cool and dry for at least 12 hours before use.
• Calibration: Perform periodic calibration verification using a balance and distilled water per ISO 8655 guidelines; calibration tools are provided.
• Inspection: Inspect the tip cone, O‑rings, and piston for wear or damage before each use.
• Tip Loading: Press the pipette vertically into the tip box to seat the tip; avoid rocking or excessive tapping.
• Aspiration Technique: Depress the plunger to the first stop, immerse the tip below the liquid surface, then release the plunger slowly and smoothly.
• Dispensing Technique: Place the tip against the receiving vessel wall, depress the plunger to the first stop, wait one second, then press to the second stop to expel residual liquid.
• Lubrication: Apply silicone grease to the piston and seals as recommended by the manufacturer.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Precision, fixed‑volume liquid handling for standardised diagnostic assays (ELISA, PCR), clinical chemistry, molecular biology, pharmaceutical quality control, and high‑throughput industrial testing where error‑free, reproducible reagent addition is mandatory.
-
Clinical Role: An essential instrument for clinical diagnostic laboratories, molecular diagnostics labs, immunology laboratories, blood banks, pathology departments, pharmaceutical QC facilities, and industrial testing sites where fixed‑volume accuracy and full sterilisability are required for patient sample processing.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Chemical Compatibility: Verify that the pipette materials are compatible with the specific reagents used; the pipette is designed to resist a wide range of laboratory chemicals.
• Autoclaving Preparation: Pipette can be autoclaved without disassembly; after autoclaving, allow to cool and dry for at least 12 hours before use.
• Tip Fit: Ensure the pipette tip is securely attached before aspirating; a loose tip may cause inaccurate volume delivery or sample loss.
• Aspiration Technique: Release the plunger slowly and smoothly to prevent foaming, splashing, or aspiration of air bubbles that could affect volume accuracy.
• Avoid Dropping: Dropping the pipette may damage the internal piston mechanism and affect calibration; recalibrate if dropped.
• Cleaning: Do not immerse the entire pipette in liquid; wipe exterior surfaces only.
• Training: Only trained laboratory personnel should operate the MicroPette Plus Fixed Volume Pipette for clinical diagnostic applications.
2. FIRST AID MEASURES
-
Sample Splash: If a biological or chemical sample splashes into the eyes, flush immediately with water for 15 minutes and seek medical attention; if splashed on the skin, wash thoroughly with soap and water.
• Chemical Exposure: If the pipette is contaminated with hazardous chemicals, refer to the specific Safety Data Sheet (SDS) for detailed first‑aid instructions.
• Mechanical Injury: If a pipette tip punctures the skin (sharps injury), wash the wound thoroughly and follow the facility’s exposure management protocol for bloodborne pathogens.
• Autoclave Burn: If handling the pipette immediately after autoclaving, use heat‑resistant gloves; if a burn occurs, cool the area with cool running water for 15 minutes and seek medical attention.
• Inhalation: If chemical vapours are inhaled during reagent preparation, move to fresh air immediately; seek medical attention if symptoms persist.
3. FIRE FIGHTING MEASURES
-
Flammability: Plastic components and the tip ejector are combustible; they may melt or burn if exposed to flame or high heat.
• Extinguishing Media: Use carbon dioxide (CO₂) or a dry chemical extinguisher for fires involving plastic materials.
• Fire Response: The primary fire hazard is the flammable laboratory reagents being handled; follow the laboratory’s fire safety protocols.
Related products
Applicator Sticks
$1.00
Applicator Sticks are single-use medical devices with absorbent tips (cotton, rayon, flocked polyester) on wood, plastic, or paper shafts for collecting clinical specimens (throat, nasal, wound, cervical, urethral, rectal) for microbiological culture, rapid testing, and molecular diagnostics. Sterile individually wrapped or non-sterile bulk formats. Flocked swabs provide >90% specimen release for PCR testing. Primary applications include specimen collection for infection diagnosis, wound care and antiseptic application, gynecological sampling (Pap smears, STI testing), eye/ear specimen collection, laboratory slide preparation, and forensic evidence collection. Critical precautions include single-use only, sterile technique, proper collection method, and biohazard disposal. Essential consumable in all clinical settings.
Cover Glass
$1.00
Cover Glass (coverslips) are thin, transparent glass or plastic squares (e.g., 18×18 mm, 22×22 mm) or rectangles (22×30 mm, 24×50 mm) used to cover specimens on microscope slides for microscopic examination. Available in thickness No. 1 (0.13-0.16 mm) and No. 1.5 (0.16-0.19 mm) for optimal microscopy. Made from optical glass with high light transmission (>90%), refractive index 1.52 matching immersion oil. Packaged in boxes of 100-1000, interleaved with paper to prevent scratching. Primary clinical applications include covering blood films for manual differential counts and malaria diagnosis, wet mount preparations of urine sediment and vaginal secretions, histopathology and cytology slides, Gram-stained bacterial smears, semen analysis, KOH preparations for fungal elements, and India ink preparations for Cryptococcus. Critical safety precautions include handling with forceps (sharp edges), disposing of broken coverslips in sharps containers, avoiding fingerprints on optical surface, and proper disposal of biohazard-contaminated coverslips. Essential consumable in every clinical laboratory performing microscopy.
CRP Test Kit
$1.00
CRP Test Kit (C-Reactive Protein) is a quantitative or semi-quantitative immunoassay (latex agglutination, turbidimetry, nephelometry, ELISA, or rapid immunochromatographic) for detecting C-reactive protein in blood, an acute-phase reactant produced in response to inflammation. Rapid rise within 6-12 hours, peaks at 24-48 hours, half-life 19 hours. Normal <5-10 mg/L; mild elevation 10-100 mg/L (viral infections, autoimmune flares); moderate 100-200 mg/L (bacterial infections); marked >200 mg/L (sepsis, major trauma). High-sensitivity CRP (hs-CRP) detects 0.1-10 mg/L for cardiovascular risk stratification (<1 mg/L low risk, 1-3 mg/L moderate, >3 mg/L high). Primary clinical applications include detection and monitoring of inflammation, diagnosis and management of infections (differentiating bacterial from viral), assessment of autoimmune disease activity, post-surgical monitoring for complications, cardiovascular risk screening (hs-CRP), monitoring rheumatic fever and inflammatory conditions, and neonatal sepsis evaluation. Critical safety precautions include proper sample handling (universal precautions), quality control verification, awareness of non-specific elevation, prozone phenomenon in very high concentrations, and clinical correlation for interpretation. Essential test for evaluating inflammation across all medical specialties.
ESR Tubes Glass
$1.00
ESR Tubes Glass are specialized glass tubes (300 mm length, 2.55 mm bore diameter, graduated 0-200 mm in 1 mm intervals) meeting ICSH and CLSI Westergren specifications for measuring erythrocyte sedimentation rate, a non-specific marker of inflammation. Used with citrated or diluted EDTA blood, filled to exactly 200 mm, placed vertically in Westergren stand, and read at 60 minutes. Primary clinical applications include determination of ESR for diagnosing and monitoring inflammatory conditions (infections, autoimmune disorders, malignancies), monitoring disease activity in rheumatoid arthritis, assessment of temporal arteritis and polymyalgia rheumatica, evaluation of infection and inflammatory response, screening for occult inflammatory conditions, and monitoring chronic inflammatory diseases (SLE, IBD, vasculitis). Critical safety precautions include handling glass tubes carefully to avoid breakage (sharps hazard), proper disposal in sharps containers as biohazardous waste, ensuring vertical alignment and constant temperature (18-25°C), reading at exactly 60 minutes, and avoiding air bubbles and vibration. Essential consumable for reference Westergren ESR testing in clinical laboratories.
Hepatitis C Test Kit
$1.00
The Hepatitis C Test Kit is an in vitro diagnostic device for the detection of Hepatitis C virus antibodies or RNA in human blood, serum, or plasma samples. Available in rapid, laboratory immunoassay, and molecular formats, it screens for HCV infection, confirms active infection with RNA testing, and monitors treatment response. With high sensitivity and specificity exceeding 99%, it is essential for identifying infected individuals, linking them to curative direct-acting antiviral therapy, and confirming cure. Essential applications include risk-based screening of high-risk populations, birth cohort screening of baby boomers, evaluation of acute hepatitis, management of occupational exposures, and monitoring of antiviral therapy that can cure over 95% of infections. All patient samples must be handled with universal precautions, and positive antibody results require confirmatory testing.
Manual Centrifuge
$1.00
A Manual Centrifuge (hand-powered) is a non-electric mechanical device for separating fluids based on density, designed for use in field clinics, remote health posts, and developing world settings where electricity is unavailable or unreliable. Operated by hand crank, pull-cord, or foot pedal, achieving speeds of 1,000-4,000 RPM and RCF up to 1,500 x g. Accepts standard blood collection tubes (2-5 mL), microhematocrit tubes, and small centrifuge tubes. Primary clinical applications include separation of serum/plasma for basic diagnostic testing, urine sediment concentration for microscopy, microhematocrit determination for anemia screening, concentration of parasites for malaria and other vector-borne disease diagnosis, field epidemiology and outbreak investigation, veterinary medicine in rural settings, and teaching in resource-limited institutions. Critical safety precautions include meticulous balancing of tubes by weight (absolutely essential), never exceeding maximum rated speed, using appropriate PPE (no aerosol containment), regular inspection of gears and rotor for wear, and proper training of operators. Essential equipment for basic laboratory capabilities in low-resource and field settings.
Rota virus
$1.00
Rota virus rapid tests are immunochromatographic assays (CE-marked, FDA-cleared for some brands) for qualitative detection of rotavirus group A antigens in stool specimens, providing results in 10-20 minutes. The test principle uses monoclonal or polyclonal antibodies against rotavirus antigens (typically VP6 protein) immobilized on membranes, capturing antigens that form a visible line. Sensitivity 90-98%, specificity 95-99% compared to ELISA or PCR. The kit includes individually foil-wrapped test devices, sample diluent, and collection applicators. Primary clinical applications include rapid diagnosis of acute gastroenteritis in children (rotavirus is the leading cause of severe diarrhea in under-5 children), outbreak investigation in daycare centers and schools, hospital infection control and isolation precautions, differential diagnosis of acute diarrhea (viral vs. bacterial vs. parasitic), vaccine effectiveness monitoring and surveillance, assessment of dehydration risk, and evaluation of immunocompromised patients. Critical safety precautions include proper specimen collection (clean container, avoid contamination), biological hazard precautions (all stool potentially infectious), quality control verification, and awareness that a negative test does not rule out other causes of gastroenteritis. Essential tool for pediatric gastroenteritis management, infection control, and public health surveillance.
VDRL Test For Syphilis
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties