An Infantometer is a medical measuring device (typically 0-100 cm range, 1 mm graduation) designed for accurate recumbent length measurement of neonates, infants, and children up to 2 years of age. Features include rigid base board, fixed headboard, movable perpendicular footboard with smooth-gliding mechanism, and measurement scale (analog engraved or digital display). Constructed from medical-grade materials (wood, acrylic, ABS plastic, aluminum/stainless steel) with non-porous, easy-to-clean surfaces and rounded safety edges. Accuracy ±1-2 mm meets WHO and CDC requirements for growth monitoring. Primary clinical applications include accurate length measurement for growth assessment (WHO/CDC growth charts), early detection of growth abnormalities (failure to thrive, growth retardation), nutritional status monitoring (weight-for-length), premature infant follow-up, endocrine disorder evaluation (growth hormone deficiency), genetic syndrome assessment (syndrome-specific charts), and research studies requiring precise anthropometrics. Class I medical device. Critical safety considerations include two-person measurement technique, proper infant positioning (neutral head, gentle leg extension), infection control (cleaning between infants), stability on level surface, and regular calibration verification. Essential equipment in pediatric clinics, well-child visits, NICU, and child health research.
Description
Infantometer
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Accurate Length Measurement for Growth Assessment:
-
Primary Use: Provides precise measurement of recumbent length in neonates, infants, and young children up to 2 years of age, which is essential for plotting growth trajectories on standardized growth charts (WHO, CDC) and assessing overall health and nutritional status.
-
How it helps: Tracks a child’s physical development with precision, giving parents and pediatricians confidence that a baby is growing properly or alerting them to concerns that need attention.
2. Early Detection of Growth Abnormalities:
-
Primary Use: Serial length measurements allow early identification of failure to thrive, growth retardation, or excessive growth that may indicate underlying endocrine, metabolic, or genetic disorders requiring further evaluation.
-
How it helps: Spots growth problems early, when interventions can make the biggest difference, ensuring children with underlying conditions receive timely evaluation and treatment.
3. Nutritional Status Monitoring:
-
Primary Use: Length measurements combined with weight enable calculation of weight-for-length percentiles and Z-scores, critical for diagnosing malnutrition, wasting, or obesity in the pediatric population.
-
How it helps: Provides a complete picture of a child’s nutritional health, helping doctors distinguish between children who are simply small and those who are malnourished and need intervention.
4. Premature Infant Follow-up:
-
Primary Use: Extremely premature infants require close monitoring of linear growth to ensure catch-up growth and identify those at risk for long-term growth impairment.
-
How it helps: Gives parents of preemies and their doctors the detailed tracking needed to ensure these tiny fighters are catching up to their full-term peers, providing reassurance and guiding interventions.
5. Endocrine Disorder Evaluation:
-
Primary Use: Children with suspected growth hormone deficiency, hypothyroidism, or other endocrine disorders require precise, serial length measurements to document growth velocity and guide diagnostic workup and treatment.
-
How it helps: Provides the objective data endocrinologists need to diagnose growth disorders and monitor response to treatment, helping children reach their full growth potential.
6. Genetic Syndrome Assessment:
-
Primary Use: Infants with dysmorphic features or known genetic syndromes (Down syndrome, Turner syndrome, achondroplasia) need accurate length measurements for syndrome-specific growth chart monitoring.
-
How it helps: Ensures children with genetic conditions are tracked against appropriate standards, helping doctors distinguish between normal variation for their syndrome and problems that need intervention.
7. Research and Clinical Trials:
-
Primary Use: Used in pediatric research studies requiring precise anthropometric measurements for outcomes assessment in nutrition, growth, and developmental studies.
-
How it helps: Contributes to scientific understanding of child development and helps develop evidence-based guidelines for pediatric care.
SECONDARY & SUPPORTIVE USES
1. Head Circumference Measurement: Some infantometers include fixed or sliding calipers for simultaneous head circumference measurement, providing additional growth parameters in one device.
2. Length Measurement in Children with Disabilities: Useful for measuring recumbent length in older children with physical disabilities who cannot stand for height measurement, ensuring all children receive accurate growth monitoring.
3. Neonatal Intensive Care Unit Monitoring: Daily length measurements track growth in NICU infants, particularly those with complex medical conditions affecting growth, providing critical data for managing the most vulnerable patients.
4. Adoption and Foster Care Assessments: Initial health assessments for internationally adopted children include accurate length measurement for age estimation and growth evaluation, helping ensure these children receive appropriate care.
5. Public Health Nutrition Programs: Used in WIC (Women, Infants, and Children) clinics and similar programs worldwide for growth monitoring, supporting population-level nutrition interventions.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: Measuring device specifically designed for accurate recumbent length measurement of infants and young children.
-
Common Names: Infantometer, Infant Length Board, Recumbent Length Board, Neonatal Length Measurer, Baby Measuring Board.
-
Components:
-
Base Board: Rigid, flat surface supporting the infant during measurement.
-
Fixed Headboard: Perpendicular plate at zero end against which the infant's head is placed.
-
Movable Footboard: Sliding plate that moves to contact infant's feet; perpendicular to base.
-
Measurement Scale: Calibrated ruler (typically in millimeters and centimeters) along base edge.
-
Digital Display (select models): Electronic readout of length measurement.
-
-
Measurement Range: 0-100 cm (0-40 inches) typical; some models extend to 120 cm (47 inches).
-
Graduation: 1 mm or 0.1 cm for clinical accuracy.
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Accuracy: ±1-2 mm for clinical-grade infantometers; meets WHO and CDC accuracy requirements for growth monitoring.
-
Resolution: 1 mm analog or 0.1 mm digital for precise measurement.
-
Scale Type:
-
Analog: Engraved or printed scale on base; read manually.
-
Digital: Electronic readout with LCD display; may include data storage and export.
-
-
Footboard Movement: Smooth-gliding mechanism with locking capability for accurate reading.
-
Material: Medical-grade materials resistant to cleaning agents and disinfectants.
-
Weight Capacity: 15-25 kg (33-55 lbs) typical; sufficient for infants and toddlers.
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Overall Length: 110-130 cm (43-51 inches) for 100 cm measurement range.
-
Width: 25-40 cm (10-16 inches) providing a stable base.
-
Height: 5-15 cm (2-6 inches) low profile for infant safety.
-
Weight: 3-8 kg (6.6-17.6 lbs) depending on materials and features.
-
Material Options:
-
Wood: Traditional, durable, economical; may absorb moisture; heavier.
-
Acrylic/Plexiglass: Transparent, lightweight, easy to clean; may scratch.
-
ABS Plastic: Lightweight, durable, easy to clean, modern.
-
Aluminum/Stainless Steel: Premium, durable, autoclavable components; expensive.
-
-
Surface Finish: Smooth, non-porous, easy-to-clean surface; rounded edges for safety.
-
Portability: Some models fold or disassemble for transport between clinics.
-
Storage: May hang on the wall or store flat when not in use.
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: Class I medical device; 510(k) exempt.
-
Intended Use: For measuring recumbent length of infants and young children.
-
Biocompatibility: All patient-contact materials meet ISO 10993 for skin contact.
-
Latex-Free: All components latex-free.
-
Cleanability: Non-porous surfaces withstand repeated disinfection with EPA-registered hospital disinfectants.
-
Stability: Wide base prevents tipping during use; non-slip feet secure on table surface.
-
Edge Safety: All edges rounded or beveled to prevent injury.
-
Weight Capacity: Clearly marked; do not exceed.
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store flat or hung on wall in clean, dry environment; protect from impact.
-
Cleaning: Wipe with EPA-registered hospital disinfectant between patients. For heavy soil, clean with mild soap and water, rinse, then disinfect. Dry thoroughly.
-
Calibration: Annual calibration check recommended; verify against known standard (e.g., calibrated rod). Digital models may require factory calibration.
-
Inspection: Before each use, verify footboard moves smoothly, scale is legible, and surfaces are clean and undamaged.
-
Portable Models: Follow manufacturer instructions for assembly/disassembly; ensure all components securely locked before use.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Accurate recumbent length measurement for growth assessment in neonates, infants, and children up to 2 years in pediatric clinics, well-child visits, NICU, and research settings.
-
Measurement Technique (Standardized):
-
Place the infantometer on a flat, stable surface.
-
Lay infant supine with head against fixed headboard, eyes looking vertically.
-
The parent or assistant holds the infant's head in position.
-
Gently extend the infant's legs by applying light pressure to knees.
-
Slide footboard to firmly contact infant's soles with toes pointing upward.
-
Read measurement to nearest 0.1 cm.
-
Repeat for accuracy; average two measurements within 0.5 cm.
-
-
Growth Chart Integration: Measurements plotted on WHO or CDC growth charts for age- and sex-appropriate percentiles and Z-scores.
-
Limitations: Requires two trained personnel for accurate measurement; infant movement affects accuracy; not for standing height.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Two-Person Technique: Ideally use two trained personnel: one to position head, one to extend legs and read measurement. Single-person measurements are less accurate.
-
Infant Positioning: Ensure the infant's head is in neutral position (eyes looking vertically) for accurate measurement. Hyperextension or flexion affects length.
-
Gentle Leg Extension: Apply gentle, steady pressure to knees; excessive force can cause discomfort or rarely injury.
-
Footboard Contact: Footboard should firmly contact soles; do not compress toes.
-
Infection Control: Clean between each infant; disinfect thoroughly after each use, especially in NICU settings.
-
Stability: Place on stable, level surface; ensure non-slip feet engaged.
-
Temperature: Ensure device at comfortable room temperature; cold surface may cause infant agitation.
-
Calibration: Regular calibration verification essential for accurate growth tracking.
-
Documentation: Record measurement immediately; note any factors affecting accuracy (infant movement, crying).
2. FIRST AID MEASURES
-
Infant Discomfort: Stop measurement; comfort infant; reposition and try again.
-
Skin Irritation: If skin reaction occurs, discontinue use; cleanse skin; consider alternative cleaning agent.
-
Equipment Damage: If footboard jams or scale damaged, remove from service; tag for repair.
3. FIRE FIGHTING MEASURES
-
Flammability: Wood, plastic, and acrylic components are combustible; metal components non-combustible.
-
Extinguishing Media: Use water, foam, CO₂, or dry chemical as appropriate for surrounding fire.
Related products
Anti-Streptol Olysin O Titer (ASOT)
$24.23
Anti-Streptol Olysin O Titer (ASOT) is a quantitative or semi-quantitative serological test (latex agglutination, turbidimetry, nephelometry, or ELISA) for detecting antibodies against streptolysin O, an exotoxin produced by Group A Streptococcus. Elevated or rising titers indicate recent streptococcal infection and are essential for diagnosing post-streptococcal sequelae including acute rheumatic fever (Jones criteria) and post-streptococcal glomerulonephritis. The test requires serum samples; acute and convalescent (2-4 weeks apart) with fourfold rise confirms recent infection. Reference range typically <200-250 Todd units/mL (adults), varies by age and population. Primary clinical applications include diagnosis of Group A streptococcal infections, acute rheumatic fever evaluation, post-streptococcal glomerulonephritis diagnosis, differentiation of acute vs. past infection, evaluation of unexplained arthritis or carditis, pediatric inflammatory conditions (PANDAS), and monitoring disease activity in rheumatic fever. Critical safety precautions include proper timing of acute and convalescent samples, awareness of false negatives/positives, clinical correlation for diagnosis, and standard biohazard precautions. Essential test for rheumatology, nephrology, cardiology, and infectious disease practice.
Dual Head Stethoscope
$1.00
The Dual Head Stethoscope is the classic, essential acoustic diagnostic tool used by healthcare professionals worldwide. Its defining feature is a two-sided chestpiece, combining a diaphragm for high-frequency sounds (breath sounds, normal heart tones) and a bell for low-frequency sounds (heart murmurs, abnormal heart tones). Through mechanical sound conduction, it provides critical information for assessing cardiac, pulmonary, and vascular systems during physical examinations and manual blood pressure measurement. Its effectiveness relies on proper technique, a good acoustic seal, and consistent cleaning. As a fundamental symbol of medical practice, it balances functionality, durability, and affordability.
Littman Stethoscope (Classic 4 Cardiology)
$1.00
A Littman Stethoscope (Classic 4 Cardiology) represents the pinnacle of acoustic auscultation technology. Designed for clinicians who require the highest level of diagnostic accuracy, it features dual tunable diaphragms and dual-lumen tubing to provide exceptional acoustic sensitivity and ambient noise reduction. Its innovative design allows the user to hear both high and low-frequency sounds by simply adjusting pressure on either side of the chestpiece, making it the instrument of choice for cardiologists, intensivists, and specialists who cannot afford to miss a subtle murmur, rub, or breath sound. It combines superior performance with the durability and comfort expected from the Littmann brand.
MUAC Tape
$1.00
A MUAC Tape (Mid-Upper Arm Circumference) is a specialized, color-coded measuring tape used globally as the primary field tool for screening children aged 6-59 months for acute malnutrition. Its simple design—featuring red, yellow, and green zones corresponding to Severe Acute Malnutrition, Moderate Acute Malnutrition, and normal nutritional status—allows for instant, non-invasive assessment without the need for scales, calculation, or literacy. Durable, portable, and inexpensive, it is the cornerstone of community-based nutrition programs, emergency relief efforts, and public health surveillance, enabling early detection and life-saving intervention for malnourished children in even the most resource-constrained settings.
Patient Monitor
$1.00
The Patient Monitor (6 Parameters BCCMS8000) is a versatile multi-parameter monitor designed for continuous surveillance of core vital signs in various clinical settings. It tracks six essential parameters—ECG, SpO2, Non-Invasive Blood Pressure (NIBP), Respiration, Temperature, and Pulse Rate—providing clinicians with real-time waveforms and numerical data on a clear color display. With its robust alarm system, battery backup for transport, and reliable performance, it is a fundamental tool for ensuring patient safety on general hospital wards, during procedures, and in emergency departments. Its design balances comprehensive monitoring capability with user-friendly operation.
SAFE SERIES Blood Collection Needles
$88.46
The SAFE SERIES (AM-SAFE) by Beijing Precil (Mindray subsidiary) is a comprehensive line of safety-engineered blood collection devices designed to prevent accidental needlestick injuries in healthcare workers. The series includes venous blood collection needles (AM-SAFE-V), standard safety needles (AM-SAFE1), winged infusion sets/butterfly needles (AM-SAFE2), high-gauge thin-wall needles for fragile veins (AM-SAFE3), premium coated needles for enhanced patient comfort (AM-GOLD), and nurse-friendly one-handed safety variants (AM-NURSE). All devices incorporate integral safety mechanisms that shield the contaminated needle immediately after withdrawal, complying with OSHA Needlestick Safety and Prevention Act requirements. Available in various gauges (18G-25G) and configurations for routine venipuncture, difficult vein access, pediatric/geriatric patients, and frequent blood draws. Sterile, single-use, latex-free, and color-coded for easy gauge identification. Essential safety devices for blood collection in hospitals, clinics, laboratories, and home healthcare settings.
VDRL Test For Syphilis
$1.00
The VDRL Test For Syphilis (Venereal Disease Research Laboratory) is a Class II medical device (FDA-cleared) non-treponemal flocculation test for qualitative and quantitative detection of reaginic antibodies in serum or cerebrospinal fluid, used for syphilis screening, diagnosis, and treatment monitoring. The test uses an antigen mixture (cardiolipin, cholesterol, lecithin) that reacts with antibodies, forming visible clumping (flocculation) in positive samples. Results are reported as reactive/non-reactive with quantitative titers (e.g., 1:2 to 1:256). Primary clinical applications include initial screening for syphilis infection, confirmation of active syphilis (with treponemal tests), monitoring treatment response (fourfold titer decrease indicates cure), diagnosis of neurosyphilis (CSF testing), prenatal screening for congenital syphilis prevention, screening in high-risk populations (MSM, HIV-positive, multiple partners), and blood donor screening. Critical safety precautions include confirmation of all reactive results with treponemal tests (TPPA, FTA-ABS), awareness of false positives (pregnancy, autoimmune disease, viral infections), proper specimen handling (universal precautions), refrigerated storage of reagents (2-8°C), and mandatory reporting of reactive results to public health authorities. Essential test for syphilis control and congenital syphilis prevention worldwide.
Wrist Blood Pressure Monitor
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties