Magnetic Stirrer(MS‑S)
WhatsApp Order
Magnetic Stirrer is a reliable, economical benchtop instrument engineered for efficient, reproducible mixing in clinical diagnostics, pharmaceutical quality control, water quality monitoring, food and beverage safety testing, and general research laboratories. Featuring a 5‑inch (Ø135 mm) round ceramic‑coated stainless steel work plate, this analog stirrer provides a The maximum stirring capacity of 20 liters and a stepless speed range of 0 to 1500 rpm via a simple scale‑graded dial.
Every MS‑S is constructed with a chemical‑resistant ceramic‑coated stainless steel work plate that withstands strong acids, strong alkalis, and organic solvents, ensuring long‑term durability and easy cleaning. The maintenance‑free, spark‑free brushless DC motor provides quiet, reliable, and consistent stirring performance suitable for continuous daily use. The universal 100–240 V, 50/60 Hz power supply allows direct use in laboratories worldwide without voltage conversion.
Key user‑focused features include stepless analog speed control via a single rotary knob with a clear scale‑graded dial for approximate speed selection, a large 20‑liter stirring capacity suitable for batch preparation of bulk reagents and quality control materials, support for stirring bars up to 80 mm in length for powerful magnetic coupling even with viscous solutions, and an IP42‑rated fully enclosed housing providing protection against solid foreign objects (>12.5 mm) and splashing water from any direction. The instrument is TÜV‑certified (CE, cTUVus, FCC) and manufactured under ISO 9001 and ISO 13485 quality management systems.
For the clinical laboratory scientist, pharmaceutical QC analyst, water quality technician, and food safety tester, the MS‑S delivers the large‑capacity, chemical‑resistant, and reliable stirring required for routine reagent preparation, buffer mixing, dissolution media preparation, sample homogenization, and QC material preparation. For the patient and the public, consistent and accurate mixing of reagents, buffers, and diagnostic samples directly supports reliable test results, safe pharmaceutical products, accurate environmental monitoring, and effective clinical decision‑making.
Categories: Pipettes, Dispensers, and Lab Glassware, LABORATORY EQUIPMENT AND SUPPLIES
Tags: 20L Stirrer, 5‑Inch Stirrer, Analog Magnetic Stirrer, Benchtop Stirrer, Brushless DC Motor Stirrer, Buffer Preparation, Ceramic Coated Stirrer, Chemical Resistant Stirrer, Clinical Laboratory Mixing, Dissolution Media, Environmental Testing, IP42 Stirrer, Magnetic Stirrer, Microbiology Media Preparation, MS‑S, Non‑Heating Magnetic Stirrer, Pharmaceutical QC, Quality Control Stirring, Reagent Preparation, TÜV Certified, Water Quality Analysis
Description
Magnetic Stirrer(MS‑S)
PRIMARY CLINICAL & DIAGNOSTIC USES
1. General Solution Mixing and Reagent Preparation for Clinical Laboratories
Primary Use: Provides an analog magnetic stirrer with a 5‑inch (Ø135 mm) ceramic‑coated stainless steel work plate and a maintenance‑free brushless DC motor, used for the efficient and homogeneous mixing of aqueous solutions, buffers, reagents, and clinical laboratory preparations, with a maximum stirring capacity of 20 liters, a stepless analog speed range of 0 to 1500 rpm via scale‑graded dial, and an IP42‑rated fully enclosed housing for dust and splash protection.
How it helps: For the clinical laboratory scientist and medical technologist, the MS‑S‘s maintenance‑free, spark‑free brushless DC motor delivers consistent, reliable stirring performance ideal for preparing common laboratory reagents and buffers. The ceramic‑coated stainless steel work plate provides excellent chemical resistance against strong acids, strong alkalis, and organic solvents, ensuring long‑term durability even with aggressive reagents. The scale‑graded analog speed dial allows stepless speed adjustment from 0 to 1500 rpm, accommodating gentle mixing for cell suspensions and vigorous agitation for dissolving powdered media. The IP42‑rated fully enclosed housing offers protection against solid foreign objects (>12.5 mm) and splashing water from any direction, making the instrument durable for routine clinical use. For the patient, consistent and reproducible mixing of reagents ensures the accuracy of diagnostic test results, supporting reliable clinical decision‑making.
2. Sample Preparation for Water Quality and Environmental Monitoring
Primary Use: An ideal tool for general laboratories performing water quality analysis and environmental monitoring, the MS‑S is used for mixing samples and reagents for key tests, such as Chemical Oxygen Demand (COD), heavy metal analysis, and total suspended solids measurement, and for preparing liquid cultures for microbiological analysis of environmental samples.
How it helps: For the environmental laboratory technician, the MS‑S‘s large 20‑liter stirring capacity allows batch‑wise processing of multiple samples, improving workflow efficiency. The ceramic‑coated work plate withstands exposure to various water quality testing reagents, including strong oxidizing agents and acid digestion solutions. The analog speed dial allows the user to set the approximate stirring speed without complex digital menus, while the IP42‑rated housing provides basic protection against spills and splashes commonly encountered in water quality testing. For the public, reliable water quality analysis supported by consistent sample mixing ensures safe drinking water and accurate environmental monitoring data.
3. Dissolving Solids and Preparing Solutions for Drug and Food Analysis
Primary Use: Used for the efficient dissolution of solids and the preparation of standard solutions, buffers, and mobile phases in pharmaceutical and food analysis laboratories, ensuring homogeneity for quality control testing such as high‑performance liquid chromatography (HPLC) and UV‑Vis spectrophotometry.
How it helps: For the pharmaceutical and food safety quality control analyst, the MS‑S‘s robust stirring action ensures that powders, tablets (after grinding), or other solid samples are completely dissolved and mixed into solution before analysis. The ceramic‑coated work plate is easy to clean and resistant to a wide range of organic solvents and acids used in HPLC mobile phase preparation. The strong magnetic coupling (rare earth magnets) prevents stir bar decoupling even when mixing higher‑viscosity solutions, ensuring consistent agitation throughout the dissolution process. For the patient, accurate sample preparation is critical for verifying the potency of drugs and ensuring the safety and quality of the food supply.
4. Liquid Culture Mixing and Preparation in Clinical Microbiology
Primary Use: Enables the gentle yet thorough mixing of liquid cell cultures, microbial broths, and growth media in clinical microbiology laboratories to maintain a uniform cell suspension and optimize growth conditions, without the risk of heat damage to sensitive biological samples.
How it helps: For the clinical microbiology technologist, the MS‑S’s stepless analog speed control allows for precise agitation, ensuring that bacterial and yeast cultures are evenly oxygenated and mixed without damaging the cells. The brushless DC motor produces no sparks and operates with low noise, making it safe for use in environments where flammable solvents or volatile reagents may be present. The flat, chemical‑resistant ceramic‑coated surface simplifies cleaning and decontamination between culture preparations. For the patient, the careful preparation of culture media using consistent and reproducible mixing ensures the accurate identification of pathogenic microorganisms, leading to timely and appropriate antimicrobial therapy selection.
SECONDARY & SUPPORTIVE USES
1.Electrochemical measurements and pH calibration: Provides stable and consistent stirring of solutions during electrochemical experiments, such as pH calibration and measurement, ion‑selective electrode analysis, and manual titration, ensuring a uniform ion concentration around the electrode for fast, accurate readings.
2.General solution preparation for analytical chemistry: Prepares precise chemical solutions for high‑performance liquid chromatography, gas chromatography, and other analytical chemistry techniques by thoroughly dissolving solids and ensuring a homogeneous mixture, with a large 20‑liter capacity for batch processing.
3.Heavy metal and trace element analysis sample mixing: Prepares liquid and digested samples for heavy metal analysis using atomic absorption spectroscopy or inductively inductively coupled plasma mass spectrometry by maintaining solid particles in suspension for accurate sampling, with a chemical‑resistant ceramic plate suitable for acidic solutions.
4.Biological Oxygen Demand (BOD) and Chemical Oxygen Demand (COD) water testing: Prepares samples and reagents for essential water quality tests by ensuring the complete dissolution and uniform mixing of the strong oxidizing agents and other chemicals used in oxygen demand analysis.
5.Protein assay sample mixing: Gently mixes protein samples with Bradford, bicinchoninic acid (BCA), or Lowry reagents in cuvettes or tubes before spectrophotometric measurement, ensuring complete reaction and uniform color development for accurate total protein quantification.
6.DNA and RNA extraction reagent homogenization: Provides consistent agitation during lysis, binding, washing, and elution steps in manual nucleic acid extraction workflows, ensuring magnetic beads or silica membranes contact all reagents evenly and improving nucleic acid yield and purity.
7.Research and development in academic and industrial labs: Provides a reliable, economical stirring solution for research scientists performing small‑scale chemical synthesis, media optimization, and other reaction studies requiring reproducible agitation.
8.General and educational laboratory use: Serves as an economical, user‑friendly teaching tool for demonstrating the principles of solution preparation, mixing, and chemical reaction kinetics in high school and university chemistry and biology laboratory courses, with a compact footprint and simple analog controls.
KEY PRODUCT FEATURES
1.BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A non‑heating, analog magnetic stirrer with a round ceramic‑coated stainless steel work plate.
-
Designation: MS‑S Magnetic Stirrer; DLAB MS‑S; Standard Analog Magnetic Stirrer.
-
Key Components:
-
5‑inch (Ø135 mm) round stainless steel work plate with ceramic coating for excellent chemical resistance and easy cleaning
-
Maintenance‑free, spark‑free brushless DC motor
-
Scale‑graded analog speed dial for stepless adjustment (0–1500 rpm)
-
Strong rare earth magnets for powerful magnetic coupling
-
IP42‑rated fully enclosed housing (protection against solid foreign objects >12.5 mm and splashing water from any direction)
-
Universal power supply (100–240 V, 50/60 Hz)
-
Non‑slip rubber feet for stability
-
2.TECHNICAL & PERFORMANCE PROPERTIES
-
Work plate dimensions: Ø135 mm (5 inches) .
-
Work plate material: Stainless steel with ceramic coating (strong acid‑resistant, strong alkali‑resistant, corrosion‑resistant, easy to clean) .
-
Motor type: Maintenance‑free, spark‑free brushless DC motor .
-
Maximum stirring capacity (H₂O): 20 liters .
-
Speed range: 0 to 1500 rpm (stepless analog control via scale‑graded dial) .
-
Speed display: Scale‑graded analog dial .
-
Maximum stir bar length: 80 mm .
-
Number of stirring positions: 1 .
-
Motor input power: 18 W .
-
Motor output power: 10 W .
-
Total power consumption: 30 W .
-
Protection class (IP rating): IP42 (protection against solid foreign objects >12.5 mm and splashing water from any direction) .
-
Power requirements: 100–120 V / 200–240 V, 50/60 Hz (universal input) .
-
Dimensions (W × D × H): 160 × 280 × 85 mm .
-
Weight: 2.8 kg .
-
Operating conditions: 5–40 °C, ≤80 % relative humidity .
-
Certifications: TÜV‑certified (CE, cTUVus, FCC); meets DIN/EN 60529 (IP code), IEC/EN 61010‑1 safety requirements for laboratory electrical equipment .
3.PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: Compact benchtop design with a fully enclosed metal housing (IP42‑rated) and a ceramic‑coated stainless steel work plate, providing protection against dust and splashing water from any direction, as well as excellent chemical resistance.
-
Work plate: 5‑inch (Ø135 mm) round stainless steel disc with ceramic coating, providing fast, uniform magnetic coupling, strong chemical resistance (strong acid‑resistant, strong alkali‑resistant), and easy cleaning.
-
Operation: Simple, intuitive analog operation with a single control knob for stepless speed adjustment from 0 to 1500 rpm. The scale‑graded dial allows users to set and reproduce desired speeds easily. Plug‑and‑play design with no complex programming required.
-
Stirring system: The brushless DC motor drives powerful rare earth magnets (strong magnetic magnet), providing high magnetic adhesion to prevent stir bar decoupling even with viscous liquids or at high speeds. The electronic speed control with microprocessor feedback ensures constant speed is maintained even when the liquid load changes (e.g., viscosity increases during dissolution).
-
Safety functions:
-
IP42 protection class: The IP42‑rated housing provides protection against solid foreign objects >12.5 mm and splashing water from any direction (DIN/EN 60529), making the instrument suitable for general laboratory environments where minor spills and splashes are routine.
-
Spark‑free brushless motor: The brushless DC motor is spark‑free, making the instrument safer for use in environments where flammable solvents may be present.
-
Flame‑retardant housing: The fully enclosed housing is constructed from flame‑retardant materials, providing basic fire safety protection.
-
Over‑current protection: Basic circuit protection ensures safe operation under normal conditions.
-
-
Spill protection: IP42‑rated housing offers protection against splashing water from any direction. The smooth ceramic coating is resistant to chemical attack and easy to wipe clean after spills.
-
Portability: Compact benchtop design with a small footprint (160 × 280 mm) and moderate weight (2.8 kg), easily moved between workstations.
-
Maintenance: The brushless DC motor is maintenance‑free, requiring no routine brush replacement or lubrication. The ceramic‑coated work plate is easy to clean with a mild detergent and soft, damp cloth.
-
Included accessories: The standard package includes the MS‑S magnetic stirrer, one PTFE‑coated magnetic stirring bar (≈50 mm length), and a region‑specific power cord, with a quick start guide and calibration certificate.
-
Warranty: 2‑year manufacturer’s warranty (in most regions).
4.SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: General laboratory equipment for in vitro diagnostic (IVD) use. Manufactured under ISO 9001 and ISO 13485 quality management systems. TÜV‑certified safety: CE, cTUVus, FCC; meets DIN/EN 60529 (IP code), IEC/EN 61010‑1 safety requirements for laboratory electrical equipment .
-
IP42 Protection Class (Ingress Protection): The IP42 rating (DIN/EN 60529) provides protection against solid foreign objects >12.5 mm and splashing water from any direction, ensuring reliable service in busy clinical and laboratory environments.
-
Motor Safety: The brushless DC motor is spark‑free, making the instrument safe for use in environments where flammable solvents or volatile reagents may be present.
-
Electrical Safety: Designed with a universal power supply (100–240 V, 50/60 Hz) for safe operation across multiple regions without voltage conversion. The IP42‑rated housing offers protection against dust and splashing water.
-
Chemical Safety: The ceramic‑coated stainless steel work plate is resistant to strong acids, strong alkalis, and organic solvents, preventing corrosion and ensuring a long service life even when handling aggressive reagents.
-
Fire Safety: Flame‑retardant plastic housing and ceramic‑coated work plate provide basic fire protection and heat dissipation.
-
Quality Assurance: Each instrument is factory‑calibrated and supplied with a calibration certificate. The instrument is backed by a 2‑year manufacturer’s warranty.
5.STORAGE & HANDLING ATTRIBUTES
-
Storage: Store the instrument in a clean, dry, dust‑free environment at room temperature (15–30 °C) when not in use. Keep the work plate covered to prevent dust accumulation. The IP42 rating provides protection against dust ingress during storage.
-
Installation: Place the instrument on a stable, level, non‑flammable laboratory benchtop away from flammable materials, volatile solvents, and strong magnetic fields (e.g., large magnets, NMR equipment). Allow adequate clearance for ventilation. The wide operating voltage (100–240 V) allows worldwide use without a voltage converter.
-
Cleaning: Unplug the unit before cleaning. Wipe the ceramic‑coated work plate and the metal housing with a soft, damp cloth using a mild laboratory detergent or 70 % isopropyl alcohol. Do not immerse the unit in liquid. Do not use abrasive cleaners or metal‑scouring pads, which may scratch the ceramic coating.
-
Pre‑use inspection: Before each use, inspect the power cord and plug for any damage. Ensure the work plate is clean, dry, and free of chemical residues. Check that the magnetic stir bar is in good condition without chips or cracks and is appropriately sized for the vessel (recommended stir bar length ≤80 mm). Verify that the instrument is not placed near sources of strong magnetic fields, which could interfere with the magnetic coupling.
-
Operation: Place the stirring vessel (e.g., a beaker, flask, or tube) centrally on the work plate. Add the magnetic stir bar to the vessel. Turn on the main power. Set the desired stirring speed by turning the control knob (range 0–1500 rpm). The scale‑graded dial shows the approximate speed setting. Always start stirring at a low speed (200–300 rpm) to allow the stir bar to couple correctly before gradually increasing to the target speed. The electronic speed control with microprocessor feedback maintains constant speed even under changing load conditions.
-
Cooling down: Not applicable (non‑heating model). The work plate remains at ambient temperature during normal use.
-
Periodic verification: Verify the stirring performance periodically by observing the scale‑graded dial and assessing stir bar coupling. If calibration is required (e.g., to confirm that t’s performance log.
6.LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: General‑purpose, non‑heating stirring for clinical diagnostics (reagent preparation, buffer mixing), pharmaceutical quality control (standard solution preparation), water quality and environmental monitoring (sample homogenization), food and bthe set speed approximates the actual speed), consult the manufacturer‘s service guidelines. Keep a record of verifications as part of the instrumeneverage safety testing, and general research laboratories where an economical, large‑capacity, chemically resistant, non‑heating analog magnetic stirrer is required.
-
Clinical Role: A versatile and essential benchtop instrument for hospital and clinical laboratories, clinical chemistry departments, immunology and serology labs, diagnostic microbiology laboratories, pharmaceutical quality control facilities, environmental testing stations, food and beverage safety labs, and research institutions. Critical for routine reagent preparation, dissolving and mixing buffers and diluents used in automated analyzers, QC standard preparation, and any laboratory workflow requiring consistent, reproducible, large‑capacity stirring.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Magnetic Field Interference: The stirrer contains strong permanent neodymium magnets. People with implanted medical devices (e.g., pacemakers, neurostimulators, implantable cardioverter‑defibrillators) should keep a safe distance of at least 30 cm from the operating stirrer. Do not place the instrument near credit cards, hard drives, computer monitors, or other magnetic‑sensitive equipment.
-
Vessel and Stir Bar Selection: Use only flat‑bottomed vessels (beakers, Erlenmeyer flasks, crystallising dishes) that sit flush on the ceramic‑coated work plate. Ensure each vessel is properly centred over the magnetic drive coil. Select stir bars in good condition without chips, cracks, or deformities. Do not exceed the maximum stir bar length (80 mm).
-
Start Slowly: Always start stirring at the lowest speed (just above “0” on the dial) and gradually increase to the desired speed. A sudden high‑speed start may cause the stir bar to decouple, spin erratically, and strike the vessel wall, causing splashing, spillage, or vessel breakage.
-
Electrical Safety: Do not operate the instrument with wet hands. Ensure the mains power cable does not come into contact with liquids or sharp edges that could damage the insulation. Use only the supplied grounded power cord and ensure the outlet provides proper grounding. Do not operate if the power cord is damaged.
-
Operating Environment: The MS‑S is designed for indoor laboratory use only. Do not use the instrument in explosive atmospheres, in the presence of flammable gases or vapours, or in environments where condensation is likely to occur. The permissible ambient temperature range is 5–40 °C with relative humidity not exceeding 80 %. Place the instrument on a stable, level benchtop with at least 5 cm clearance on all sides for ventilation. Do not cover the instrument during operation.
-
Spill Management: If a liquid spill occurs on the work plate during operation, turn off the speed immediately to “0”. After the spill has been wiped clean and the work plate is completely dry, resume operation. Prolonged contact with aggressive solvents (e.g., acetone, chlorinated solvents) may damage the ceramic coating. Do not pour solvents directly onto the work plate.
-
Cleaning and Maintenance: Unplug the instrument before cleaning. Wipe the ceramic‑coated work plate and the outer housing with a soft, slightly damp cloth using a mild laboratory detergent or 70 % isopropyl alcohol. Do not immerse the unit in liquid. Do not use abrasive cleaners, metal scouring pads, or sharp objects that could scratch the ceramic coating. Allow the work plate to dry thoroughly before reconnecting power.
-
Multi‑Vessel Use: When stirring multiple vessels (if the work plate is large enough), ensure they are positioned at least 1 cm apart to prevent magnetic interference and accidental collisions. Do not stack or overload the work plate with vessels that exceed its load capacity.
-
Training Requirement: Only trained laboratory personnel with appropriate technical background in laboratory equipment operation should operate the MS‑S for clinical diagnostic or research applications. Users must read and understand the operator’s manual before first use. Laboratory managers should ensure that all operators are aware of the proper procedure for starting and stopping the stir bar.
2. FIRST AID MEASURES
-
Chemical Splash to Eyes: If a biological or chemical sample splashes into the eyes during operation, immediately flush the eyes with copious amounts of water or sterile saline for at least 15 minutes. Seek immediate medical attention.
-
Skin Contact with Chemical Sample: Remove contaminated clothing at once. Wash the affected skin area with soap and water for at least 5 minutes. If irritation or signs of chemical burn develop, seek medical evaluation. Refer to the Safety Data Sheet (SDS) for the specific chemical involved.
-
Sharps Injury (Broken Glassware): If a broken vessel lacerates the skin, allow the wound to bleed freely. Wash the wound with soap and water for 15 minutes. Apply antiseptic and a sterile bandage. If the vessel contained patient biological material, follow the facility’s exposure management protocol for bloodborne pathogens.
-
Inhalation of Chemical Vapors: If vapours from volatile reagents are inhaled during sample preparation, move the affected person to fresh air immediately. Administer oxygen if breathing is difficult. Seek medical attention if coughing, dizziness, or respiratory distress persists.
-
Electrical Shock: If an electrical shock incident occurs, disconnect power at the circuit breaker or unplug the instrument before attempting to assist the victim. Do not touch the victim until the power is disconnected. Call emergency medical services immediately.
3. FIRE FIGHTING MEASURES
-
Flammability: The instrument’s metal housing is non‑combustible, but the plastic control panel, power cord, and electronic components are combustible. Do not operate near flammable solvents, gases, or volatile materials (e.g., diethyl ether, acetone, hexane). The primary fire hazard is the flammable liquids being stirred.
-
Extinguishing Media: Use carbon dioxide (CO₂) or a dry chemical (ABC‑class) extinguisher for fires involving the electrical components. Do not use water, as water conducts electricity and may cause electrical shock or damage the instrument.
-
Fire Response: In case of fire, disconnect the instrument from its power source if safe to do so. Evacuate the immediate area. Use an appropriate extinguisher for small, contained fires. For larger fires, evacuate the laboratory and call emergency services. Do not attempt to extinguish a fire if not trained or if the fire is spreading rapidly.
Related products
Anti-Streptol Olysin O Titer (ASOT)
$24.23
Anti-Streptol Olysin O Titer (ASOT) is a quantitative or semi-quantitative serological test (latex agglutination, turbidimetry, nephelometry, or ELISA) for detecting antibodies against streptolysin O, an exotoxin produced by Group A Streptococcus. Elevated or rising titers indicate recent streptococcal infection and are essential for diagnosing post-streptococcal sequelae including acute rheumatic fever (Jones criteria) and post-streptococcal glomerulonephritis. The test requires serum samples; acute and convalescent (2-4 weeks apart) with fourfold rise confirms recent infection. Reference range typically <200-250 Todd units/mL (adults), varies by age and population. Primary clinical applications include diagnosis of Group A streptococcal infections, acute rheumatic fever evaluation, post-streptococcal glomerulonephritis diagnosis, differentiation of acute vs. past infection, evaluation of unexplained arthritis or carditis, pediatric inflammatory conditions (PANDAS), and monitoring disease activity in rheumatic fever. Critical safety precautions include proper timing of acute and convalescent samples, awareness of false negatives/positives, clinical correlation for diagnosis, and standard biohazard precautions. Essential test for rheumatology, nephrology, cardiology, and infectious disease practice.
CRP Test Kit
$1.00
CRP Test Kit (C-Reactive Protein) is a quantitative or semi-quantitative immunoassay (latex agglutination, turbidimetry, nephelometry, ELISA, or rapid immunochromatographic) for detecting C-reactive protein in blood, an acute-phase reactant produced in response to inflammation. Rapid rise within 6-12 hours, peaks at 24-48 hours, half-life 19 hours. Normal <5-10 mg/L; mild elevation 10-100 mg/L (viral infections, autoimmune flares); moderate 100-200 mg/L (bacterial infections); marked >200 mg/L (sepsis, major trauma). High-sensitivity CRP (hs-CRP) detects 0.1-10 mg/L for cardiovascular risk stratification (<1 mg/L low risk, 1-3 mg/L moderate, >3 mg/L high). Primary clinical applications include detection and monitoring of inflammation, diagnosis and management of infections (differentiating bacterial from viral), assessment of autoimmune disease activity, post-surgical monitoring for complications, cardiovascular risk screening (hs-CRP), monitoring rheumatic fever and inflammatory conditions, and neonatal sepsis evaluation. Critical safety precautions include proper sample handling (universal precautions), quality control verification, awareness of non-specific elevation, prozone phenomenon in very high concentrations, and clinical correlation for interpretation. Essential test for evaluating inflammation across all medical specialties.
Manual Centrifuge
$1.00
A Manual Centrifuge (hand-powered) is a non-electric mechanical device for separating fluids based on density, designed for use in field clinics, remote health posts, and developing world settings where electricity is unavailable or unreliable. Operated by hand crank, pull-cord, or foot pedal, achieving speeds of 1,000-4,000 RPM and RCF up to 1,500 x g. Accepts standard blood collection tubes (2-5 mL), microhematocrit tubes, and small centrifuge tubes. Primary clinical applications include separation of serum/plasma for basic diagnostic testing, urine sediment concentration for microscopy, microhematocrit determination for anemia screening, concentration of parasites for malaria and other vector-borne disease diagnosis, field epidemiology and outbreak investigation, veterinary medicine in rural settings, and teaching in resource-limited institutions. Critical safety precautions include meticulous balancing of tubes by weight (absolutely essential), never exceeding maximum rated speed, using appropriate PPE (no aerosol containment), regular inspection of gears and rotor for wear, and proper training of operators. Essential equipment for basic laboratory capabilities in low-resource and field settings.
PRECIL Series
$1.00
The PRECIL Series, originally developed by Beijing Precil and now associated with Mindray, comprises specialized coagulation analyzers and hemorheology analyzers for clinical laboratory testing. Coagulation analyzers measure PT, APTT, fibrinogen, TT, D-dimer, factor assays, and thrombophilia markers for diagnosing bleeding disorders, monitoring anticoagulant therapy, and assessing liver function. Hemorheology analyzers measure whole blood viscosity, plasma viscosity, erythrocyte aggregation, and deformability for evaluating hyperviscosity syndromes, sickle cell disease, diabetes, and cardiovascular disorders. The series includes specialized cleaning solutions and reagents (such as PLS cleaner) for maintaining analyzer performance and ensuring accurate results. Features include automated sample processing, color touchscreen interface, LIS connectivity, and comprehensive quality control programs. Primary clinical applications include coagulation testing for preoperative assessment, anticoagulant monitoring, DIC diagnosis, thrombophilia workup, and hemorheology assessment for conditions affecting blood flow. Essential laboratory instrumentation for hematology, coagulation, and specialized testing in hospital laboratories, reference laboratories, and research facilities.
Rheumatoid factor
$1.00
Rheumatoid Factor (RF) testing is a quantitative or semi-quantitative serological assay (nephelometry, turbidimetry, latex agglutination, or ELISA) for detecting autoantibodies against the Fc portion of immunoglobulin G, primarily of the IgM isotype. RF is a key marker in the ACR/EULAR classification criteria for rheumatoid arthritis, with sensitivity 60-80% and specificity 70-90%. Test requires serum samples; results reported in IU/mL (reference <15-20 IU/mL) or titer. Primary clinical applications include diagnosis and classification of rheumatoid arthritis, prognostic assessment (high-titer RF correlates with severe, erosive disease), differential diagnosis of inflammatory arthritis, monitoring disease activity, diagnosis of Sjögren's syndrome, evaluation of mixed cryoglobulinemia (hepatitis C-associated), and assessment of other autoimmune and chronic inflammatory conditions. Critical safety precautions include awareness of false positives (other autoimmune diseases, chronic infections, healthy elderly), false negatives (seronegative RA 20-30%), need for clinical correlation, and anti-CCP antibody testing to improve diagnostic accuracy. Essential test for rheumatology practice, autoimmune disease evaluation, and differential diagnosis of inflammatory arthritis.
Rota virus
$1.00
Rota virus rapid tests are immunochromatographic assays (CE-marked, FDA-cleared for some brands) for qualitative detection of rotavirus group A antigens in stool specimens, providing results in 10-20 minutes. The test principle uses monoclonal or polyclonal antibodies against rotavirus antigens (typically VP6 protein) immobilized on membranes, capturing antigens that form a visible line. Sensitivity 90-98%, specificity 95-99% compared to ELISA or PCR. The kit includes individually foil-wrapped test devices, sample diluent, and collection applicators. Primary clinical applications include rapid diagnosis of acute gastroenteritis in children (rotavirus is the leading cause of severe diarrhea in under-5 children), outbreak investigation in daycare centers and schools, hospital infection control and isolation precautions, differential diagnosis of acute diarrhea (viral vs. bacterial vs. parasitic), vaccine effectiveness monitoring and surveillance, assessment of dehydration risk, and evaluation of immunocompromised patients. Critical safety precautions include proper specimen collection (clean container, avoid contamination), biological hazard precautions (all stool potentially infectious), quality control verification, and awareness that a negative test does not rule out other causes of gastroenteritis. Essential tool for pediatric gastroenteritis management, infection control, and public health surveillance.
Vacutainer (EDTA/PLAIN)
$1.00
Vacutainer (EDTA/PLAIN) is a sterile, evacuated blood collection tube (lavender/purple top) containing EDTA anticoagulant (K2EDTA or K3EDTA, 1.5-2.0 mg/mL blood) for hematology, blood banking, flow cytometry, and molecular diagnostics. Available in draw volumes 2-10 mL, glass or PET plastic, with color-coded stopper and sterile interior. EDTA chelates calcium, preventing coagulation while preserving cellular morphology. Primary clinical applications include complete blood count (CBC) and differential, blood typing and antibody screening (ABO/Rh, Coombs), hemoglobin A1c (HbA1c) testing, flow cytometry and immunophenotyping (CD4 counts), molecular diagnostics and PCR testing, sickle cell screening and hemoglobin electrophoresis, and parasitology (malaria smears). Critical safety precautions include filling to completion (correct blood-to-additive ratio), gentle inversion 8-10 times immediately after collection, never using for chemistry or coagulation testing, and proper disposal as biohazardous waste. Essential collection tube for hematology and immunohematology.
VDRL Test For Syphilis
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties