Pro Multifunctional Orbital Decolorizing Shaker (SK-O180-)

WhatsApp Order
The Pro Multifunctional Orbital Decolorizing Shaker (SK-O180-) is a professional digital platform shaker built for rigorous laboratory applications requiring high throughput and consistent results . Featuring a powerful brushless DC motor, it supports a heavy load capacity of up to 3kg while ensuring quiet, maintenance-free operation . The large 330x330mm platform and 20mm orbit diameter provide a smooth, circular mixing action ideal for gel decolorization, Western blot washing, and cell culture aeration .
With precise digital control, the unit offers an adjustable speed range of 50-350 rpm, allowing users to switch between gentle orbital mixing for membrane incubation and high-speed agitation for rapid destaining . The digital timer can be set up to 19 hours 59 minutes, providing true walk-away automation. Its robust construction and reliable performance make the Pro Multifunctional Orbital Decolorizing Shaker (SK-O180-) a critical tool in molecular biology, clinical pathology, and pharmaceutical R&D laboratories.
Description

Pro Multifunctional Orbital Decolorizing Shaker (SK-O180-)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Orbital Decolorization for High-Resolution Gel Imaging
  • Primary Use: Provides a digital orbital shaker with a 20mm orbit diameter, variable speed control (50-350 rpm), and dual independent LED displays, engineered specifically for uniform and rapid destaining of electrophoresis gels .
  • How it helps: For the molecular biologist and laboratory technician, the orbital motion of the Pro Multifunctional Orbital Decolorizing Shaker (SK-O180-) Pro efficiently agitates destaining solutions, accelerating the removal of background stain without damaging the gel . This results in clearer bands and more accurate densitometry for diagnostic tests . For the patient, this precision leads to more reliable test results for conditions like hereditary anemias or protein disorders, reducing the need for repeat analysis .
2. Western Blot Membrane Agitation
  • Primary Use: Used for consistent, gentle washing of Western blot membranes and antibody incubations, ensuring even reagent coverage during the immunodetection process .
  • How it helps: For the immunology technologist, the smooth orbital motion ensures that blocking buffers and wash solutions flow evenly across the membrane surface, reducing background noise and enhancing specific signal detection . This consistency is critical for confirmatory testing of HIV, Lyme disease, and autoimmune markers. For the patient, this sensitivity ensures accurate diagnosis and therapeutic monitoring .
3. DNA Hybridization and Molecular Biology
  • Primary Use: Suitable for Southern and Northern blot hybridization, as well as DNA renaturation processes, requiring precise temperature control (operable in incubators) and consistent fluid movement .
  • How it helps: For the geneticist, the ability to operate the SK-O180-Pro inside a standard incubator (5-40°C) allows for stringent temperature control during nucleic acid hybridization, improving binding specificity and reducing false positives . For the patient undergoing genetic cancer screening or hereditary disease testing, this ensures high-fidelity results .
4. High-Load Cell Culture and Aeration
  • Primary Use: Featuring a high torque motor with a load capacity of up to 3 kg, suitable for continuous shaking of multiple flasks and culture dishes for cell aeration and nutrient mixing .
  • How it helps: For the cell biologist, the quiet, robust DC motor can handle high workloads without stalling, ensuring uniform growth conditions across large-scale cell culture preparations . This efficiency speeds up processes like vaccine development or cell-based therapy preparation. For the patient, this efficiency helps accelerate the development and availability of advanced biological therapies.

SECONDARY & SUPPORTIVE USES


1. Electrophoresis Gel Staining: Distributes Coomassie blue, silver, and fluorescent stains evenly for consistent protein detection .
2. Immunoprecipitation: Provides the gentle but consistent rotation required for capturing antigen-antibody complexes in solution .
3. Liquid-Solid Suspension Mixing: Effectively resuspends cell pellets or homogenized tissue samples in buffers .
4. Clinical Chemistry Preparation: Mixes serum, plasma, or urine samples on a benchtop rocker before analysis .
5. Pharmaceutical Quality Control: Agitates QC samples for dissolution testing or stability studies in R&D labs .
6. Fermentation and Bioprocessing: Provides continuous aeration for microbial or yeast cultures in flasks .
7. Cold Room and Incubator Use: Engineered to operate reliably in cold rooms (5°C) and standard incubators (up to 40°C) for temperature-sensitive applications .
8. User Calibration: Supports user calibration for speed control, ensuring accuracy across the full 50-350 rpm range .
9. RS232 & PC Software: Connect to a computer via RS232 interface; free Shaker PC software allows real-time display of working curves on a computer .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A high-performance digital orbital shaker designed for decolorizing, blotting, and general liquid mixing in clinical and research labs .
  • Designation: SK-O180-Pro Multifunctional Orbital Decolorizing Shaker, Professional Digital Orbital Shaker .
  • Key Components:
    • Motion Type: Orbital (Circular) shaking with 20mm orbit .
    • Platform: 330 x 330 mm (13" x 13") loading platform .
    • Display: Dual independent LCD displays for speed and time .
    • Motor: Brushless DC motor .
    • Interface: RS232 for data export and PC software .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Tilt/Orbit Angle: 20mm Orbital Diameter .
  • Speed Range: 50-350 rpm (adjustable) .
  • Load Capacity: 3 kg (approx. 6.6 lbs) .
  • Timer: Programmable, 1 minute to 19 hours 59 minutes .
  • Operating Temp: 5-40°C (Cold Room/Incubator Compatible) .
  • Voltage: 100-240V, 50/60Hz .
  • Power: 30W .
  • Dimensions (mm): 210 x 365 x 100 .
  • Weight: 6.5 kg .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Sturdy, low-profile housing .
  • Platform: Large surface with anti-slip rubber mat .
  • Noise: Low-noise brushless DC motor for quiet operation .
  • Control: User-friendly digital interface with knob .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Safety: IP21 protection; Automatic stop when lid is opened (if accessory is used); Overload detection .
  • Certifications: CE, cTUVus .

5. STORAGE & HANDLING ATTRIBUTES

  • Cleaning: Wipe with 70% Isopropyl alcohol or mild detergent .
  • Maintenance: Brushless motor requires zero maintenance .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Load Capacity: Do not exceed maximum load capacity of 2.5 kg; overloading may cause motor stress and inaccurate speed regulation.

  • Platform Loading: Distribute load evenly across platform to ensure smooth operation and prevent imbalance.

  • Container Security: Ensure all vessels are securely attached to platform using appropriate clamps or non-slip mats.

  • Speed Selection: Start with lower speeds when using heavy loads or large vessels; gradually increase to desired speed.

  • Cleaning: Clean spills immediately; disinfect if biological or hazardous materials are involved.

  • Placement: Place on stable, level, vibration-dampened surface; ensure adequate ventilation around instrument.

  • Cold Room Use: Allow instrument to acclimate to cold room temperature before operation to prevent condensation.

  • Training: Only trained laboratory personnel should operate the shaker.

2. FIRST AID MEASURES

  • Sample Spill: If sample spills onto instrument, stop operation immediately, unplug unit, clean and disinfect affected area thoroughly.

  • Instrument Malfunction: If irregular noise or vibration occurs, stop instrument, check load balance and platform security.

  • Power Failure: If power fails during operation, manually remove samples after power is restored; timed runs will need to be reset.

  • Overspeed Alarm: If overspeed detection activates, reduce set speed and restart; ensure load is within specifications.

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components present fire risk.

  • Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for electrical fires.

  • Fire Response: Unplug instrument immediately; do not use water on electrical fire.