Fetoheart Sonic Aid Doppler (clinic/hospital use)
$1.00
WhatsApp Order
A Fetoheart Sonic Aid Doppler (Fetal Doppler) is a Class II medical ultrasound device (2-3 MHz probe) for real-time detection and audible/visual display of fetal heart rate in clinical obstetric settings from 10-12 weeks gestation. Features include handheld or tabletop console, waterproof probe, digital heart rate display (30-240 bpm), amplified speaker, headphone jack, and rechargeable battery or AC power operation. Continuous wave or pulsed wave Doppler technology with auto-correlation signal processing rejects maternal artifact. Primary clinical applications include fetal heart rate detection and monitoring during routine prenatal visits, confirmation of fetal viability in first trimester, intermittent fetal monitoring during labor, non-stress test administration, multiple gestation assessment, fetal presentation determination, and post-procedure confirmation (amniocentesis, CVS, ECV). Critical safety considerations include following ALARA principle (minimum necessary exposure), appropriate ultrasound gel use, probe pressure avoidance, infection control (probe cleaning between patients), differentiation of fetal from maternal signals, and interpretation by qualified providers. Essential equipment in outpatient obstetric clinics, hospital labor and delivery units, and prenatal care settings.
Categories: DIAGNOSTIC EQUIPMENT, Diagnostic Kits, Fetal Dopplers and Monitors, Multi-Parameter Monitors, OBSTETRICS, GYNECOLOGY AND NEONATAL, PATIENT MONITORING AND LIFE SUPPORT
Tags: Dop tone, Fetal Doppler, Fetal Heart Detector, Fetal Monitor, Labor And Delivery, Obstetric Ultrasound, Prenatal Care
Description
Fetoheart Sonic Aid Doppler (clinic/hospital use)
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Fetal Heart Rate Detection and Monitoring:
-
Primary Use: Provides real-time audible and visual display of fetal heart rate using Doppler ultrasound technology, allowing clinicians to assess fetal cardiac activity, rate, and rhythm during routine prenatal visits from as early as 10-12 weeks gestation.
-
How it helps: Gives obstetricians and midwives an immediate window into the baby’s well-being at every prenatal visit, providing objective evidence that the pregnancy is progressing normally and alerting them to any concerns that need further investigation.
2. Confirmation of Fetal Viability:
-
Primary Use: Rapid, non-invasive confirmation of fetal cardiac activity in first-trimester pregnancies, particularly valuable for patients with history of miscarriage, bleeding, or cramping where viability assessment is clinically indicated.
-
How it helps: Provides anxious parents and their doctors with immediate answers during moments of uncertainty, offering reassurance that the pregnancy is viable when there are concerns about miscarriage.
3. Intermittent Fetal Monitoring During Labor:
-
Primary Use: Used in hospital labor and delivery units for periodic assessment of fetal heart rate between contractions in low-risk pregnancies, providing audible feedback of fetal response to labor.
-
How it helps: Allows laboring mothers to maintain mobility and a less restrictive birth experience while still ensuring their baby is regularly checked for any signs of distress.
4. Non-Stress Test (NST) Administration:
-
Primary Use: Integrated with fetal monitors for non-stress testing in outpatient obstetric clinics, assessing fetal heart rate accelerations in response to fetal movement as an indicator of fetal well-being.
-
How it helps: Provides reassurance that a baby in a high-risk pregnancy is healthy and receiving enough oxygen, helping doctors make informed decisions about delivery timing.
5. Multiple Gestation Assessment:
-
Primary Use: Allows identification and monitoring of individual fetal heart rates in twin and higher-order multiple pregnancies, with experienced clinicians able to distinguish between fetuses.
-
How it helps: Helps clinicians caring for mothers expecting multiples ensure each baby is developing normally, providing individual attention to every fetus in the womb.
6. Fetal Presentation and Position Determination:
-
Primary Use: The point of maximal intensity of fetal heart sounds helps experienced practitioners determine fetal lie and presentation, particularly in later gestation.
-
How it helps: Gives clinicians valuable information about how the baby is positioned before delivery, helping them plan for a safe birth and anticipate any potential complications.
7. Post-Procedure Confirmation:
-
Primary Use: Used after amniocentesis, chorionic villus sampling, or external cephalic version to confirm continued fetal well-being and cardiac activity.
-
How it helps: Provides immediate reassurance after invasive procedures that the baby is tolerating the intervention well and that fetal heart activity remains normal.
SECONDARY & SUPPORTIVE USES
1. Patient Reassurance: Provides audible fetal heart sounds to expectant parents during prenatal visits, enhancing bonding and reducing anxiety by letting them hear their baby’s heartbeat.
2. Teaching Tool: Used in obstetric education to teach students and residents fetal heart rate auscultation and interpretation, training the next generation of healthcare providers.
3. Triage Assessment: Rapid assessment of fetal heart rate in patients presenting to labor and delivery with decreased fetal movement or other concerns, helping prioritize care.
4. Preoperative Verification: Confirms fetal heart rate prior to cerclage placement or other obstetric procedures, ensuring the baby is stable before interventions.
5. Research Applications: Used in studies requiring fetal heart rate data collection, contributing to scientific understanding of fetal development and pregnancy complications.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: Handheld or tabletop Doppler ultrasound device for fetal heart rate detection.
-
Common Names: Fetal Doppler, Fetal Heart Detector, Fetal Monitor, Doptone, Fetal Sonic Aid.
-
Components:
-
Main Unit: Handheld or tabletop console with controls and display.
-
Probe/Transducer: 2-3 MHz waterproof probe with integrated ultrasound crystal.
-
Display: LCD showing fetal heart rate (numeric) and sometimes signal strength.
-
Speaker: Built-in speaker for audible heart sounds; headphone jack available.
-
Power Source: Rechargeable battery, AC power, or replaceable batteries.
-
-
Probe Frequencies: 2 MHz (deeper penetration, later gestation, obese patients), 3 MHz (better resolution, earlier gestation, thin patients).
-
Display Range: 30-240 bpm typical.
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Ultrasound Technology: Continuous wave or pulsed wave Doppler detecting motion of fetal heart structures.
-
Output Display: Digital numeric display of fetal heart rate (averaged over 3-6 beats).
-
Audio Output: Amplified heart sounds through speaker; adjustable volume.
-
Auto-Correlation: Signal processing to reject maternal vessel noise and artifact.
-
Depth Penetration: Up to 15-20 cm depending on frequency and tissue characteristics.
-
Detection Threshold: Capable of detecting fetal heart activity from 10-12 weeks gestation; earlier in thin patients, later in obese or with retroverted uterus.
-
Battery Life: 2-8 hours continuous use depending on model.
-
Wall-Plug Operation: Continuous use capability for labor and delivery settings.
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Handheld Unit Dimensions: 15-20 cm × 5-8 cm × 3-5 cm (6-8 × 2-3 × 1-2 inches).
-
Weight: 200-500 grams (7-18 ounces) depending on battery configuration.
-
Probe: 10-15 cm length, 2-3 cm diameter; with 1.5-2 meter cable.
-
Display: 2-4 cm high LCD with large numerals.
-
Controls: On/off, volume, probe selection (if multi-probe), freeze (select models).
-
Speaker: 1-2 watts; clear audio in quiet clinical environment.
-
Headphone Jack: 3.5 mm for private listening or noisy environments.
-
Probe Storage: Built-in probe holder or separate storage compartment.
-
Carrying Case: Padded case for transport; wall-mountable bracket available.
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: Class II medical device requiring FDA 510(k) clearance.
-
Intended Use: For detection of fetal heart rate during pregnancy and labor.
-
Ultrasound Safety: Output within FDA limits for diagnostic fetal use; mechanical index (MI) < 1.9, thermal index (TI) < 1.0.
-
Electrical Safety: Compliant with IEC 60601-1 for medical electrical equipment; Type BF applied part.
-
ALARA Principle: Device operates at lowest feasible output to obtain adequate signal.
-
Probe Disinfection: Waterproof probes allow cleaning with appropriate low-level disinfectant; probe covers available for specific indications.
-
Sterility: Probes non-sterile; not for intrauterine use.
-
EMC Compliance: IEC 60601-1-2 electromagnetic compatibility; immune to typical clinical interference.
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store in clean, dry environment in carrying case or on wall mount; protect probes from damage.
-
Battery Maintenance: Recharge after each use; maintain spare charged battery for continuous use settings.
-
Probe Care: Do not drop probes; inspect cable for damage; clean after each use with approved disinfectant wipe; do not immerse probe in liquids unless specified waterproof.
-
Cleaning: Wipe unit and probe with EPA-registered hospital disinfectant between patients.
-
Calibration: Annual calibration verification recommended per facility biomedical engineering protocol.
-
Inspection: Before each use, check probe cable, connector, and housing; verify audio output and display function.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Real-time fetal heart rate detection and monitoring in outpatient obstetric clinics, hospital labor and delivery units, and prenatal care settings.
-
Gestational Age Considerations:
-
10-12 weeks: Earliest detection in ideal conditions.
-
12-14 weeks: Reliable detection in most patients with appropriate technique.
-
14-16 weeks: Consistent detection in nearly all patients.
-
16+ weeks: Routine use for all prenatal visits.
-
-
Technique:
-
Apply ultrasound gel to maternal abdomen.
-
Position probe suprapubically, angled toward pelvis.
-
Slowly sweep until fetal heart tones identified.
-
Adjust angle for optimal signal.
-
Count rate (displayed) or auscultate for 60 seconds.
-
Limitations: May be difficult in early gestation, maternal obesity, retroverted uterus, or with anterior placenta; requires ultrasound gel for acoustic coupling.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Ultrasound Safety: Follow ALARA principle (As Low As Reasonably Achievable); use minimum power and duration necessary. No known adverse effects at diagnostic output levels for fetal use.
-
Gel Use: Always use appropriate ultrasound gel; never use with dry probe.
-
Probe Pressure: Avoid excessive pressure on maternal abdomen, especially in early pregnancy.
-
Infection Control: Clean probe between each patient; use disposable probe covers if probe will contact mucous membranes or if patient has known infection.
-
Interpretation: Fetal heart rate must be interpreted by qualified healthcare providers; rates <110 or >160 bpm warrant further evaluation.
-
Maternal Signal Differentiation: Distinguish fetal heart rate (typically 110-160 bpm) from maternal vessel signal (rate equals maternal pulse).
-
Doppler Not for Home Use: These clinical-grade devices intended for trained healthcare providers; not for unsupervised home use.
-
EMI Caution: May be affected by strong electromagnetic fields; avoid use near MRI.
2. FIRST AID MEASURES
-
Inability to Detect Fetal Heart: Reposition patient; try different probe angle; use different frequency probe if available; if persistent absence after 12 weeks with previous detection, arrange urgent ultrasound.
-
Gel in Eyes: Flush with copious water; seek medical attention if irritation persists.
-
Equipment Malfunction: Discontinue use; return for service; document malfunction.
-
Maternal Discomfort: Reposition; reduce probe pressure.
3. FIRE FIGHTING MEASURES
-
Flammability: Plastic casing and components are combustible.
-
Extinguishing Media: For electrical fire, use CO₂ or dry chemical (Class C) extinguisher.
-
Battery Fire: Damaged lithium battery may ignite; use Class D extinguisher or sand.
Related products
Anti-Streptol Olysin O Titer (ASOT)
$24.23
Anti-Streptol Olysin O Titer (ASOT) is a quantitative or semi-quantitative serological test (latex agglutination, turbidimetry, nephelometry, or ELISA) for detecting antibodies against streptolysin O, an exotoxin produced by Group A Streptococcus. Elevated or rising titers indicate recent streptococcal infection and are essential for diagnosing post-streptococcal sequelae including acute rheumatic fever (Jones criteria) and post-streptococcal glomerulonephritis. The test requires serum samples; acute and convalescent (2-4 weeks apart) with fourfold rise confirms recent infection. Reference range typically <200-250 Todd units/mL (adults), varies by age and population. Primary clinical applications include diagnosis of Group A streptococcal infections, acute rheumatic fever evaluation, post-streptococcal glomerulonephritis diagnosis, differentiation of acute vs. past infection, evaluation of unexplained arthritis or carditis, pediatric inflammatory conditions (PANDAS), and monitoring disease activity in rheumatic fever. Critical safety precautions include proper timing of acute and convalescent samples, awareness of false negatives/positives, clinical correlation for diagnosis, and standard biohazard precautions. Essential test for rheumatology, nephrology, cardiology, and infectious disease practice.
Digital Baby Weighing Scale
$1.00
A Digital Baby Weighing Scale is a high-precision medical device designed exclusively for the safe and accurate measurement of infant and toddler weight. Featuring a stable, hygienic platform with gram-level precision, it is indispensable in hospitals (especially NICUs), pediatric clinics, and community health settings. Its core functions—such as hold, tare, and zeroing—ensure reliable readings even with a moving child. Accurate weight data is foundational for assessing growth, calculating medication doses, managing nutrition, and detecting early signs of health issues, making this scale a critical tool for safeguarding infant health and development.
Digital Blood Pressure Monitor
$1.00
A Digital Blood Pressure Monitor is an automatic electronic device that measures and displays systolic pressure, diastolic pressure, and pulse rate using the oscillometric method. Designed primarily for home and clinical use, it offers a user-friendly alternative to manual aneroid devices, requiring minimal training. Key features often include irregular heartbeat detection, multi-user memory, and connectivity for data tracking. Its accuracy, when clinically validated and used with correct technique, makes it an indispensable tool for the diagnosis and management of hypertension, empowering patients and supporting healthcare providers with reliable ambulatory data.
ECG Machine
$1.00
An ECG Machine is a Class II medical device that records and displays the electrical activity of the heart through surface electrodes, producing an electrocardiogram for diagnosis of cardiac conditions. Standard diagnostic machines record 12 simultaneous leads (3 limb, 6 precordial, 1 ground) with frequency response 0.05-150 Hz, sampling rate 500-1,000 Hz, and high-resolution (5-10 µV) signal acquisition. Features include color touchscreen display, thermal array printer, computerized interpretation algorithms, internal memory (50-500+ ECGs), and network connectivity for EMR integration. Lead wires (AHA or IEC color coding) connect to disposable adhesive electrodes. Portable models (5-15 kg) with rechargeable batteries enable bedside and mobile use; cart-mounted units provide full diagnostic capability. Primary clinical applications include diagnosis of arrhythmias (AF, VT, bradycardia), detection of myocardial ischemia/infarction (STEMI, NSTEMI), evaluation of chest pain, preoperative cardiac risk assessment, monitoring electrolyte imbalances, assessment of chamber enlargement, and drug effect/toxicity monitoring. Essential diagnostic equipment in emergency departments, cardiology clinics, ICUs, operating rooms, and primary care settings worldwide.
Height Board
$1.00
A Height Board, or stadiometer, is a precision medical instrument designed for the accurate measurement of human stature. As a wall-mounted or portable device featuring a vertical scale and a sliding horizontal headpiece, it is the clinical standard for obtaining height. This measurement is foundational for calculating Body Mass Index (BMI), tracking growth in children, screening for nutritional issues, and assessing adults for conditions like osteoporosis. Its accuracy, dependent on proper installation and technique, makes it an indispensable tool in pediatrics, primary care, nutrition, and public health
SAFE SERIES Blood Collection Needles
$88.46
The SAFE SERIES (AM-SAFE) by Beijing Precil (Mindray subsidiary) is a comprehensive line of safety-engineered blood collection devices designed to prevent accidental needlestick injuries in healthcare workers. The series includes venous blood collection needles (AM-SAFE-V), standard safety needles (AM-SAFE1), winged infusion sets/butterfly needles (AM-SAFE2), high-gauge thin-wall needles for fragile veins (AM-SAFE3), premium coated needles for enhanced patient comfort (AM-GOLD), and nurse-friendly one-handed safety variants (AM-NURSE). All devices incorporate integral safety mechanisms that shield the contaminated needle immediately after withdrawal, complying with OSHA Needlestick Safety and Prevention Act requirements. Available in various gauges (18G-25G) and configurations for routine venipuncture, difficult vein access, pediatric/geriatric patients, and frequent blood draws. Sterile, single-use, latex-free, and color-coded for easy gauge identification. Essential safety devices for blood collection in hospitals, clinics, laboratories, and home healthcare settings.
VDRL Test For Syphilis
$1.00
The VDRL Test For Syphilis (Venereal Disease Research Laboratory) is a Class II medical device (FDA-cleared) non-treponemal flocculation test for qualitative and quantitative detection of reaginic antibodies in serum or cerebrospinal fluid, used for syphilis screening, diagnosis, and treatment monitoring. The test uses an antigen mixture (cardiolipin, cholesterol, lecithin) that reacts with antibodies, forming visible clumping (flocculation) in positive samples. Results are reported as reactive/non-reactive with quantitative titers (e.g., 1:2 to 1:256). Primary clinical applications include initial screening for syphilis infection, confirmation of active syphilis (with treponemal tests), monitoring treatment response (fourfold titer decrease indicates cure), diagnosis of neurosyphilis (CSF testing), prenatal screening for congenital syphilis prevention, screening in high-risk populations (MSM, HIV-positive, multiple partners), and blood donor screening. Critical safety precautions include confirmation of all reactive results with treponemal tests (TPPA, FTA-ABS), awareness of false positives (pregnancy, autoimmune disease, viral infections), proper specimen handling (universal precautions), refrigerated storage of reagents (2-8°C), and mandatory reporting of reactive results to public health authorities. Essential test for syphilis control and congenital syphilis prevention worldwide.
Vein Finder
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties