Preformed Oral ET Tubes Uncuffed
$1.00
WhatsApp Order
Preformed Oral ET Tubes Uncuffed are anatomically shaped endotracheal tubes designed for pediatric and neonatal airway management. The preformed curvature conforms to the oral cavity, reducing kinking and providing a stable airway during oral surgical procedures. The uncuffed design eliminates cuff-related complications in developing airways, making them the standard of care for pediatric intubation.
Description
Preformed Oral ET Tubes Uncuffed
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Pediatric and Neonatal Airway Management
-
Primary Use: Provides a pre-shaped, anatomically designed airway for pediatric and neonatal patients requiring intubation. The preformed angle allows the tube to conform to the oral cavity and pharynx, reducing the risk of kinking and maintaining a patent airway in small patients.
-
How it helps: For the pediatric anesthesiologist and neonatologist, preformed uncuffed tubes simplify airway management in children—the fixed curvature matches the anatomy, reducing the need for manipulation and minimizing the risk of accidental extubation. For the infant or child requiring intubation, the preformed design provides a stable, secure airway with reduced risk of tube displacement.
2. Nasal Intubation Alternative for Oral Procedures
-
Primary Use: Used for oral surgical procedures where the tube must be positioned away from the operative field. The preformed angle directs the tube toward the mouth while maintaining a secure airway.
-
How it helps: For the oral surgeon and anesthesiologist performing procedures in the oral cavity, preformed oral tubes allow the tube to be positioned away from the surgical site—providing unobstructed access while maintaining airway security. For the patient undergoing oral or maxillofacial surgery, this means the surgical field is clear while ventilation remains uninterrupted.
3. Stabilization in Patients with Facial Anomalies
-
Primary Use: The preformed shape aids in securing the airway in patients with craniofacial anomalies, micrognathia, or other anatomical variations where standard tubes may be difficult to stabilize.
-
How it helps: For the pediatric anesthesiologist managing patients with congenital facial anomalies, preformed tubes provide a more stable airway that conforms to the altered anatomy—reducing the risk of accidental extubation. For the child with craniofacial abnormalities, this ensures a secure airway during surgical procedures.
4. Reduced Risk of Kinking and Obstruction
-
Primary Use: The preformed curvature is designed to prevent kinking at vulnerable angles, maintaining airway patency even with patient movement or positioning changes.
-
How it helps: For the anesthesia provider, the preformed design provides confidence that the airway will remain patent throughout the procedure—reducing the need for constant repositioning and monitoring. For the patient, this means a stable airway with reduced risk of obstruction due to tube kinking.
5. Elimination of Cuff-Related Complications
-
Primary Use: The uncuffed design eliminates the risk of cuff-related tracheal injury, making it ideal for pediatric patients where the subglottic area is the narrowest part of the airway.
-
How it helps: For the pediatric anesthesiologist, uncuffed preformed tubes reduce the risk of post-intubation stridor and subglottic stenosis in young children. For the pediatric patient, this means reduced risk of airway injury during the critical period of growth and development.
SECONDARY & SUPPORTIVE USES
1. Airway Management in Patients with Tracheal Stenosis: Used in patients with subglottic stenosis where a cuffed tube may not be tolerated.
2. Short-Term Ventilation in Infants: Suitable for brief surgical procedures in neonates and infants requiring airway management.
3. Transport of Intubated Pediatric Patients: Provides a stable, secure airway during intra-hospital transport of intubated children.
4. Craniofacial Surgery: Essential for airway management during craniofacial and cleft palate repairs where the surgical site requires unobstructed access.
5. Emergency Pediatric Intubation: Used in emergency departments for securing the airway in children requiring emergent intubation.
6. PICU Airway Management: Standard equipment in pediatric intensive care units for intubated children.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A preformed, uncuffed endotracheal tube designed for oral intubation in pediatric and neonatal patients.
-
Designation: Preformed Oral ET Tube, RAE Tube, Ring-Adair-Elwyn Tube, Pediatric Preformed Tube.
-
Key Components:
-
Preformed Curve: Anatomically shaped 90-120 degree angle to conform to oral cavity.
-
Tube Body: Flexible PVC or silicone tubing with uniform internal diameter.
-
Murphy Eye: Lateral eye at the distal tip to prevent complete obstruction.
-
Connector: Standard 15 mm connector for ventilator circuit attachment.
-
Depth Markings: Centimeter markings along the tube for accurate placement.
-
Radiopaque Line: Embedded line for radiographic confirmation of tube position.
-
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Sizes: 2.5 mm to 6.5 mm internal diameter; pediatric and neonatal sizes.
-
Length: Pre-determined lengths appropriate for pediatric patients.
-
Preformed Angle: 90-120 degrees; designed to conform to oral anatomy.
-
Material: Medical-grade PVC; non-toxic, biocompatible.
-
Murphy Eye: Present to maintain airflow if tip occludes.
-
Sterility: Ethylene oxide or gamma irradiation sterilized.
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: Smooth, atraumatic surface; preformed curvature maintains shape.
-
Depth Markings: 1 cm intervals for precise positioning.
-
Connector: Standard 15 mm ISO connector.
-
Color Coding: Often color-coded by size for rapid identification.
-
Packaging: Sterile, single-use; individually packaged.
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: Class II medical device regulated by FDA.
-
Biocompatibility: Materials safe for airway contact.
-
Latex-Free: Manufactured without natural rubber latex.
-
DEHP-Free Options: Available for sensitive populations.
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store in a clean, dry location at room temperature; protect from heat.
-
Sterility Maintenance: Do not use it if the package is opened, damaged, or wet.
-
Expiration: Check expiration date before use; do not use after expiration.
-
Single-Use Only: Intended for single patient use only; do not resterilize or reuse.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Airway management for pediatric and neonatal patients requiring intubation.
-
Clinical Role: Essential equipment in pediatric anesthesia, neonatology, pediatric intensive care, and pediatric surgery.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Tube Size Selection: Select appropriate size based on patient age, weight, and anatomy; use pediatric sizing guidelines.
-
Confirmation: Verify placement by auscultation, end-tidal COâ‚‚, and radiographic confirmation.
-
Secure Positioning: Ensure the preformed curve is oriented correctly; secure tube to prevent rotation.
-
Leak Assessment: Monitor for air leak around tube; small leak expected in uncuffed tubes.
-
Position Monitoring: Monitor for tube migration; preformed design aids stability.
-
Suctioning: Suction as needed to maintain patency.
2. FIRST AID MEASURES
-
Tube Displacement: If tube is displaced, manually ventilate patient; remove tube; reintubate as needed.
-
Obstruction: If tube is obstructed, attempt to suction; consider tube replacement if patency cannot be restored.
-
Rotation: If tube rotates, correct orientation; verify placement.
3. FIRE FIGHTING MEASURES
-
Flammability: Plastic components are combustible; an oxygen-enriched environment increases fire risk.
-
Extinguishing Media: For fire in the airway, disconnect oxygen source; remove tube if safe; use appropriate extinguisher.
Related products
Chest Bottle
$1.00
 A Chest Bottle (Underwater Seal Drainage System) is a three-chamber disposable device used to drain air and fluid from the pleural space via a chest tube. Its critical component is a water seal chamber that acts as a one-way valve, preventing air from re-entering the chest while allowing drainage. It is used to treat pneumothorax, hemothorax, and pleural effusions, and is mandatory post-thoracic surgery. The system must always be kept upright and below the patient's chest level. It provides essential clinical information through tidaling in the water seal (indicating tube patency and lung expansion) and bubbling (indicating an air leak), making it both a therapeutic and diagnostic tool.
Compressor Nebulizer Machine
$1.00
 A Compressor Nebulizer Machine is a pneumatic device that transforms liquid medication into a breathable mist for treating respiratory conditions. Consisting of an electric air compressor, a nebulizer cup, tubing, and a mask or mouthpiece, it is particularly effective for infants, children, and patients with severe asthma, COPD, or cystic fibrosis who require reliable aerosol delivery. While offering robust performance for home and clinical use, its safety and efficacy depend critically on proper cleaning to prevent infection, correct assembly, and the use of prescribed nebulizer-compatible medications. It remains a fundamental tool for both acute intervention and chronic management of pulmonary diseases.
Infant Oxygen Hood
$1.00
An Infant Oxygen Hood is a Class II medical device used to deliver controlled concentrations of supplemental oxygen to spontaneously breathing newborns and infants. Made of transparent medical-grade acrylic or polycarbonate, the hood fits over the infant's head with a soft foam or rubber neck seal, creating an oxygen-enriched environment while allowing easy access for monitoring and care. Available in premature/neonatal, infant, and older infant sizes with gas inlet ports (22 mm) for connection to air/oxygen blenders (FiO2 21-100%), access ports for monitoring leads and IV lines, and outlet vents to prevent CO2 accumulation. Requires minimum flow rate of 5 L/min to ensure adequate CO2 washout. Used with heated humidifiers for prolonged therapy to prevent airway drying. Primary clinical applications include management of respiratory distress syndrome (RDS) in premature infants, neonatal pneumonia, post-extubation oxygen support, congenital heart disease, and palliative care. Critical safety considerations include maintaining adequate flow rate to prevent rebreathing, monitoring FiO2 at hood level, ensuring proper neck seal without constriction, and preventing hyperoxia to reduce retinopathy of prematurity (ROP) risk. Essential equipment in NICUs and special care nurseries for controlled oxygen delivery to vulnerable infants.
Infant T-Piece Resuscitator
$1.00
An Infant T-piece Resuscitator is a Class II medical device designed for neonatal resuscitation and controlled positive pressure ventilation, delivering precise, consistent peak inspiratory pressures (PIP) and positive end-expiratory pressure (PEEP) as recommended by Neonatal Resuscitation Program (NRP) guidelines. The T-piece assembly connects to compressed air/oxygen source (5-15 L/min) with adjustable PIP (10-40 cmHâ‚‚O) and PEEP (0-10 cmHâ‚‚O) controls, built-in pressure manometer, and pressure relief valve (30-40 cmHâ‚‚O). Operator occludes port to deliver breaths (typically 40-60/min), with consistent pressures maintained regardless of technique. Essential advantages over bag-valve-mask devices include operator-independent pressure delivery, ability to provide PEEP (critical for preterm lung protection), reduced risk of barotrauma, and hands-free PEEP allowing two-handed mask seal. Primary clinical applications include delivery room resuscitation, stabilization of extremely preterm infants (<1,000 g), CPAP/PEEP delivery, meconium aspiration management, and neonatal transport ventilation. Critical safety considerations include verifying gas supply (5-15 L/min), monitoring manometer pressures, ensuring proper mask seal, observing chest rise, and titrating FiO2 to SpO2 targets. Indispensable resuscitation equipment in every delivery room, NICU, and neonatal transport setting worldwide.
Macintosh Bulb Laryngoscope
$1.00
A Macintosh Bulb Laryngoscope is a rigid laryngoscope with curved Macintosh blade (sizes 0-4, 70-160 mm) featuring a distal incandescent (xenon, krypton, halogen) or LED bulb at the blade tip for direct illumination during tracheal intubation. The curved blade design allows indirect epiglottis elevation by placing the tip in the vallecula, requiring less force and neck extension than straight blades. Features stainless steel reusable blades (or disposable plastic), ergonomic handles with knurled grip, ISO standard hook-on fittings, and autoclavable options. Light output 500-3,000 Lux depending on bulb type and battery condition. Primary clinical applications include routine and emergency tracheal intubation during general anesthesia, difficult airway management, cervical spine precautions (minimal neck movement), rapid sequence intubation, neonatal and pediatric intubation (sizes 0-2), teaching and training, and use in resource-limited settings. Class II medical device requiring FDA clearance. Critical safety considerations include pre-use light check (brightness, bulb security), appropriate blade size selection, proper lifting technique (not levering on teeth), battery verification, bulb obstruction risk from secretions, backup device availability, and infection control (sterilization or disposable blades).
Miller Fiber Optic Laryngoscope
$1.00
A Miller Fiber Optic Laryngoscope is a rigid laryngoscope with straight Miller blade (sizes 0-4, 70-160 mm) incorporating an integrated fiber optic light bundle that transmits bright, focused illumination (2,000-10,000+ Lux) from a handle-mounted LED or xenon bulb to the blade tip for enhanced visualization during tracheal intubation. The straight blade design allows direct elevation of the epiglottis rather than the indirect vallecula technique, making it particularly useful for pediatric/neonatal intubation, patients with floppy or prominent epiglottis, anterior airways, and difficult airways requiring direct epiglottic control. Features stainless steel reusable blades, ergonomic handles with knurled grip, ISO standard hook-on fittings, and steam autoclave compatibility. Primary clinical applications include direct epiglottis elevation for tracheal intubation (especially pediatric and neonatal), difficult airway management with fiber optic illumination, patients with prominent or floppy epiglottis, cervical spine precautions, anterior airway management, teaching and training (straight blade technique), and neonatal resuscitation. Class II medical device requiring FDA clearance. Critical safety considerations include pre-use light check (dark spots indicate broken fibers), appropriate blade size selection (especially critical in pediatrics), proper lifting technique (direct epiglottic lift, not levering on teeth), pediatric fragility awareness, battery verification, fiber optic care (avoid sharp bending), and backup device availability.
Two Bottle Suction Machine
$1.00
A Two Bottle Suction Machine is a high-capacity suction unit designed for continuous, extended use in critical care, surgical, and post-operative settings. The dual-bottle system allows for seamless rotation between bottles, enabling uninterrupted suction during bottle emptying, while the larger total capacity accommodates patients with excessive secretions. Used in intensive care units, operating rooms, and post-anesthesia care units, it provides reliable suction for airway clearance, surgical field management, and chest drainage. Enhanced overflow protection, continuous operation capability, and robust pump design make it essential for patients requiring prolonged or high-volume suction support.
Yankauer Suction
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties