Pen Meter (DPC1)
WhatsApp Order
The Pen Meter (DPC1) is a pocket-sized, multi-parameter pen tester measuring pH, ORP, conductivity, TDS, salinity, resistivity, and temperature, featuring replaceable combined electrode design (DPC1-S), multi-color backlit LCD display with reading stability indicator and automatic data lock, IP67 dustproof and waterproof rating, 1 to 3 point automatic pH calibration with buffer recognition, 1 point automatic conductivity calibration, CH/USA/NIST standard buffer compatibility, low battery indicator, user-configurable automatic shut-off and backlight duration, power-on self-diagnosis, and complete field-ready kit including hard carrying case, sample vials (4), pH buffers (pH 4.00 and 6.86, 30mL each), conductivity standards (1408 μS/cm and 12.85 mS/cm, 30mL each), 3 mol KCl electrode storage solution (10mL), four AAA batteries, and lanyard—ideal for water quality testing in clinical, pharmaceutical, and environmental applications .
For the dialysis technician, water quality specialist, infection control officer, and pharmaceutical QC chemist, the DPC1 enables rapid, on-site measurement of multiple water quality parameters—pH for assessing acid-base balance, ORP for verifying disinfection efficacy, conductivity and TDS for ionic purity, resistivity for ultrapure water verification, salinity for specific applications, and temperature for thermal monitoring . This comprehensive multi-parameter capability allows a single device to replace multiple single-parameter meters, simplifying field testing and reducing equipment costs .
Key features include multi-color backlit display with reading stability indicator and automatic data lock when stable (smiley icon), power-on self-diagnosis function, low battery indicator, user-configurable automatic shut-off time and backlight duration, and compatibility with CH, USA, and NIST calibration standards . The IP67 dustproof and waterproof rating ensures reliable operation in harsh field environments, while the complete accessory kit provides field-ready capability .
For the patient, accurate multi-parameter monitoring of water used in dialysis and pharmaceutical manufacturing ensures that critical treatment fluids meet stringent safety and quality standards—preventing potential harm from improperly treated water and supporting the production of safe, effective medications.
Categories: LABORATORY EQUIPMENT AND SUPPLIES, Analyzers
Tags: Dialysis Water Testing, DLAB DPC1, DPC1 Pen Meter, IP67 Pen Meter, Multi-Parameter Pen Tester, Pen-Type Multi-Function Analyzer, pH/EC/ORP/TDS/Salinity/Resistivity Tester, Pharmaceutical Water QC, Pocket Water Quality Analyzer, Portable Water Quality Meter
Description
Pen Meter (DPC1)
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Comprehensive Water Quality Monitoring for Dialysis and Pharmaceutical Applications
-
Primary Use: Provides a pocket-sized, multi-parameter pen meter capable of measuring pH (-2.00 to 16.00), ORP (-1000.0 to +1000.0 mV), Conductivity (0 to 19.99 mS/cm), TDS (0.0 mg/L to 10.0 g/L), Salinity (0 to 10 ppt), Resistivity (50 Ω·cm to 20 MΩ·cm), and Temperature (0 to 60°C) with high precision across automatic ranging scales .
-
How it helps: For dialysis technicians, water quality specialists, and pharmaceutical QC chemists, the DPC1 replaces multiple single-parameter meters, allowing a single device to verify the ionic purity (conductivity, TDS, resistivity), pH balance, and disinfection efficacy (ORP) of purified water, dialysis fluids, and pharmaceutical process water. The multi-color backlit display ensures easy reading in various lighting conditions, while the IP67 dustproof and waterproof rating allows for use in demanding utility environments . For the patient, this comprehensive multi-parameter monitoring ensures that water used in renal replacement therapy, drug manufacturing, and medical device processing meets all critical safety standards, preventing complications from improper water composition.
2. pH Measurement of Biological Fluids for Diagnostic Assessment
-
Primary Use: Measures pH across the range of -2.00 to 16.00 with accuracy of ±0.01 pH ±1 digit and resolution of 0.1 or 0.01, suitable for assessing pH of serum, plasma, urine, cerebrospinal fluid, and other biological specimens .
-
How it helps: For the clinical laboratory scientist and medical technologist, the DPC1 enables rapid, accurate pH measurement of biological fluids—supporting diagnosis of metabolic acidosis, alkalosis, diabetic ketoacidosis, and renal tubular disorders. The 1 to 3-point automatic calibration with buffer recognition ensures measurement reliability . For the patient, accurate pH measurement of biological fluids supports early detection of metabolic disturbances, acid-base imbalances, and renal dysfunction—enabling timely clinical intervention.
3. Oxidation-Reduction Potential for Disinfection Efficacy Monitoring
-
Primary Use: Measures ORP from -1000.0 to +1000.0 mV with accuracy of ±0.1 percent of full scale ±1 digit, providing direct assessment of the oxidizing power of disinfection processes in water treatment systems .
-
How it helps: For infection control officers and dialysis technicians, ORP measurement using the DPC1 enables rapid, on-site verification of disinfection efficacy in purified water loops, dialysis water systems, and hospital plumbing—directly confirming that oxidizing agents such as chlorine are present at effective concentrations for microbial control . For the patient, accurate ORP monitoring ensures that water used in renal replacement therapy meets critical safety standards for dialysis treatment.
4. Conductivity, TDS, and Resistivity for Water Purity Verification
-
Primary Use: Measures conductivity (0 to 19.99 mS/cm, auto-ranging), TDS (0.0 mg/L to 10.0 g/L with adjustable coefficient), resistivity (50 Ω·cm to 20 MΩ·cm), and salinity (0 to 10 ppt), providing comprehensive water purity assessment for pharmaceutical and clinical applications .
-
How it helps: For the pharmaceutical quality control chemist and water quality specialist, the DPC1 provides portable measurement of multiple water purity parameters with conductivity accuracy of ±1.0 percent of full scale ±1 digit. The auto-ranging capability ensures accurate readings across a wide range of sample types—from ultrapure water to saline solutions . For the patient, rigorous conductivity, TDS, and resistivity monitoring of pharmaceutical water systems ensures that injectable medications and intravenous solutions meet stringent purity standards, supporting product safety.
5. Smart Features for Field and Utility Water Testing
-
Primary Use: Pocket-sized pen design with replaceable combined electrode (DPC1-S), multi-color backlit LCD display, reading stability indicator with automatic data lock, low voltage indicator, user-configurable automatic shut-off time and backlight duration, and IP67 dustproof and waterproof rating .
-
How it helps: For hospital facility engineers and environmental safety officers, the DPC1’s portable, battery-operated design (4 × AAA batteries) allows for convenient spot-checking of water quality at various points in hospital water distribution systems. The kit includes a hard carrying case (28.0 × 23.0 × 8.2 cm), sample vials (30mL × 4), pH buffer solutions (pH 4.00 and 6.86, 30mL each), conductivity standard solutions (1408 μS/cm and 12.85 mS/cm, 30mL each), and electrode storage solution (3 mol KCl, 10mL) for complete field-ready capability . For the patient and community, consistent monitoring of hospital water systems helps prevent healthcare-associated infections and ensures environmental compliance.
SECONDARY & SUPPORTIVE USES
1. Disinfection Control in Hydrotherapy and Spa Pools: Monitors pH and ORP levels in hospital hydrotherapy pools, aquatic therapy centers, and spas to ensure chlorine or other oxidizers remain at effective concentrations for microbial control.
2. Cooling Tower and Boiler Water Testing: Measures pH, conductivity, and ORP in cooling towers, boiler feed water, and steam generation systems to assess corrosion potential and treatment efficacy.
3. Wastewater Treatment Monitoring: Assesses pH, conductivity, and ORP levels in hospital wastewater treatment systems to evaluate aeration efficiency and treatment process performance.
4. Environmental and Surface Water Monitoring: Portable pen format is ideal for field studies measuring pH, conductivity, and ORP in natural water bodies, drinking water, and surface water to assess ecosystem health and pollution levels.
5. Pharmaceutical Process Validation: Supports pH, conductivity, and ORP measurement for validation and routine monitoring of pharmaceutical water systems and cleaning validation protocols.
6. Antioxidant and Redox Status Assessment: Measures the oxidation-reduction potential of aqueous solutions, providing information about the total oxidizing or reducing capacity of water samples in healthcare and research applications.
7. Research and Academic Laboratories: Serves as a portable multi-parameter water quality testing tool for research applications in environmental science, chemistry, and water quality studies.
8. Food and Beverage Quality Control: Verifies pH, conductivity, and ORP levels in process water, cleaning solutions, and non-viscous beverage products in hospital nutrition services and food safety testing.
9. Aquaculture and Zebrafish Facility Management: Monitors pH, conductivity, and ORP in aquatic animal housing facilities within research institutions to ensure optimal environmental conditions.
10. Educational and Laboratory Training: Serves as a teaching tool for demonstrating multi-parameter water quality measurement principles in medical technology and clinical laboratory science training programs.
11. Electrode Replacement Compatibility: Uses replaceable DPC1-S combined electrode design, extending instrument service life and allowing continued use when the original probe reaches end of life .
12. Multiple Standard Support: Calibration compatible with CH, USA, and NIST standard buffer solutions for region-specific calibration requirements .
13. Self-Diagnosis Function: Equipped with power-on self-diagnosis to verify system integrity before each use .
14. Parameter Versatility for Diverse Sample Types: Suitable for use with various aqueous samples including drinking water, surface water, groundwater, wastewater, purified water, dialysis water, and pharmaceutical process water.
15. TDS Coefficient Adjustability: TDS coefficient adjustable from 0.40 to 1.00 for accurate total dissolved solids measurement across different sample matrices .
16. Manual Data Lock Function: Available calibration points parameter restoring to factory default function available for quality control purposes.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A pocket-sized, multi-parameter pen meter capable of measuring pH, ORP, conductivity, TDS, salinity, resistivity, and temperature, with replaceable combined electrode design, multi-color backlit LCD display, IP67 dustproof and waterproof rating, and complete field-ready accessory kit .
-
Designation: DPC1 Pen Meter, DPC1 Multi-Parameter Pen Tester, Pocket Water Quality Analyzer, DLAB DPC1, Pen-Type Multi-Function Analyzer.
-
Key Components:
-
Instrument Meter: Pocket-sized pen housing with multi-color backlit LCD display, IP67 dustproof and waterproof rating, low battery indicator, and power-on self-diagnosis function .
-
Multi-Parameter Electrode: Replaceable combined probe (DPC1-S, pre-installed) for pH, conductivity, and temperature measurement .
-
pH Buffer Solutions: pH 4.00 and pH 6.86 calibration buffers, 30mL each .
-
Conductivity Standard Solutions: 1408 μS/cm and 12.85 mS/cm conductivity calibration standards, 30mL each .
-
Electrode Storage Solution: 3 mol KCl pH and ORP electrode soaking solution, 10mL .
-
Sample Vials: 30mL sample vials (4 pieces) for convenient sample collection and testing .
-
Power Supply: Four 1.5 volt AAA alkaline batteries (pre-installed) .
-
Accessories: Hard carrying case (28.0 × 23.0 × 8.2 centimeters), lanyard, instruction manual .
-
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Measurement Parameters: pH/millivolts/degrees Celsius | ORP/millivolts/degrees Celsius | Conductivity/TDS/Salinity/Resistivity/degrees Celsius .
-
pH Measurement Range: (-2.00 to 16.00) pH .
-
pH Resolution: 0.1 or 0.01 (selectable) .
-
pH Accuracy: ±0.01 pH ±1 digit .
-
pH Calibration: 1 to 3 points automatic calibration; automatic buffer recognition .
-
pH Automatic Temperature Compensation Range: 0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit) .
-
ORP Measurement Range: (-1000.0 to +1000.0) millivolts .
-
ORP Resolution: 0.1 or 1 (selectable) .
-
ORP Accuracy: ±0.1 percent of full scale ±1 digit .
-
Conductivity Measurement Range: 0 to 19.99 mS/cm, auto-ranging segments: 0 to 19.99 μS/cm; 20.0 to 199.9 μS/cm; 200 to 1999 μS/cm; 2.00 to 19.99 mS/cm .
-
Conductivity Resolution: 0.01, 0.1, or 1 (auto-ranging) .
-
Conductivity Accuracy: ±1.0 percent of full scale ±1 digit .
-
Conductivity Calibration: 1 point automatic calibration; automatic standard recognition .
-
TDS Range: 0.0 mg/L to 10.0 g/L (TDS coefficient adjustable, default 0.71) .
-
Resistivity Range: 50 Ω·cm to 20 MΩ·cm .
-
Salinity Range: 0 to 10 ppt .
-
Temperature Measurement Range: 0.0 to 60.0 degrees Celsius (32.0 to 140.0 degrees Fahrenheit) .
-
Temperature Accuracy: ±0.2 degrees Celsius .
-
Display: Multi-color backlit LCD display; display mode changes color based on measurement status; reading stability indicator; automatic data lock when stable .
-
User Settings: Customizable automatic shut-off time; adjustable backlight display duration; low voltage indicator; power-on self-diagnosis function; restore to factory default function .
-
Calibration Options: CH, USA, and NIST standard buffer solutions .
-
Protection Class: IP67 (dustproof and waterproof against temporary immersion) .
-
Operating Conditions: 0 to 60 degrees Celsius; suitable for field and laboratory use .
-
Power: Four AAA alkaline batteries (pre-installed); user replaceable; low battery indicator .
-
Dimensions (Carrying Case): 28.0 × 23.0 × 8.2 centimeters .
-
Electrode Compatibility: Replaceable combined probe (DPC1-S) .
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: Pocket-sized, ergonomic pen-style handheld design with replaceable combined probe; IP67 dustproof and waterproof rating for field use .
-
Display: Multi-color backlit LCD display; screen color changes based on measurement status and data stability; power-on self-diagnosis function .
-
User Interface: Simple operation; short press to power on; mode selection for pH, ORP, conductivity, TDS, salinity, resistivity, and temperature; reading stability indicator (smiley icon) confirms stable measurement; automatic data lock automatically locks readings when stable .
-
Calibration: pH module supports 1 to 3 point automatic calibration with buffer recognition; conductivity module supports 1 point automatic calibration with standard solution recognition; ORP module supports 1 point calibration with 222 mV standard solution .
-
Measurement Modes: Single parameter measurement; switchable between pH, ORP, conductivity, TDS, salinity, resistivity, and temperature modes .
-
Data Locking: Auto-hold function automatically locks readings when stability indicator confirms stable measurement; short press to release auto-hold .
-
Replaceable Electrode: Combined probe design allows electrode replacement (DPC1-S) to extend instrument service life and support different measurement needs .
-
Portability: Compact pocket-sized design with hard carrying case for safe transport and storage; lanyard included for convenient carrying .
-
Power Management: Low voltage indicator alerts when batteries need replacement; user-configurable automatic shut-off and backlight duration to conserve battery life .
-
Self-Diagnosis: Power-on self-diagnosis function verifies system integrity before each use .
-
Factory Reset: Restore to factory default function available for calibration and parameter restoration .
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: In Vitro Diagnostic preparatory equipment; laboratory water quality testing instrument .
-
Safety Certifications: Manufactured under ISO 9001:2015 quality management system; CE compliant .
-
Protection Class: IP67 (dustproof and waterproof against temporary immersion up to 1 meter for 30 minutes), suitable for harsh field environments .
-
Electrical Safety: Low-voltage operation with four AAA batteries (1.5 volts each); safe for use in laboratory and field environments .
-
Material Safety: Plastic housing with replaceable combined probe; platinum sensing elements for conductivity and ORP measurement; glass pH sensing bulb; RoHS compliant materials .
-
Calibration Compliance: Supports CH, USA, and NIST standard buffer solutions for region-specific calibration requirements .
-
GLP Compliance: Multi-parameter measurement capability supports comprehensive water quality documentation for regulatory compliance .
-
Quality System: Manufactured under ISO 9001:2015 quality management system .
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store the meter in its hard carrying case in a clean, dry environment; protect from extreme temperatures and direct sunlight; remove batteries for long-term storage .
-
Cleaning: Rinse the electrode with distilled water after each use; wipe the meter body with a soft, damp cloth using a mild detergent; do not submerge the meter body beyond the IP67 rating limits; for the platinum sensing elements and glass pH bulb, avoid touching or scrubbing with abrasive materials .
-
Inspection: Inspect the electrode for damage or contamination before each use; check the glass pH bulb for cracks or damage; verify calibration before critical measurements; power-on self-diagnosis function verifies system integrity .
-
Operation: Remove the protective cap; power on by short pressing the power button; select measurement mode (pH, ORP, conductivity, TDS, salinity, resistivity, or temperature); rinse electrode with distilled water; immerse electrode in sample, stir gently; wait for stability indicator (smiley icon); read stabilized value; automatic data lock will lock readings when stable .
-
Calibration: Calibrate before first use or when measurement errors are suspected; pH: calibrate with pH 4.00 and pH 6.86 buffers (1 to 3 points); conductivity: calibrate with 1408 μS/cm or 12.85 mS/cm standard; ORP: calibrate with 222 mV standard .
-
Electrode Storage: Store electrode with protective cap in place; keep electrode moist for pH measurement; store in 3 mol KCl storage solution to prevent the pH sensing bulb from drying out .
-
Electrode Hydration: If the pH sensing bulb has dried out, soak in 3 mol KCl storage solution for 24 to 48 hours before use; recalibrate before use .
-
Battery Replacement: Replace batteries when low voltage indicator appears; use four AAA alkaline batteries (1.5 volts each); ensure correct polarity when installing new batteries .
-
Spill Management: If liquid spills onto the meter, wipe immediately with a soft, dry cloth; despite IP67 rating, avoid prolonged immersion .
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Portable, multi-parameter water quality measurement for dialysis water systems, pharmaceutical purified water loops, hospital water treatment, environmental monitoring, cooling towers, boiler feed water, wastewater treatment, aquaculture, and field water quality assessment .
-
Clinical Role: Essential water quality testing instrument for dialysis units, hospital engineering departments, infection control, pharmaceutical quality control laboratories, and environmental monitoring programs requiring rapid on-site assessment of pH, ORP, conductivity, TDS, salinity, resistivity, and temperature .
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Electrical Safety: Do not immerse the meter beyond the IP67 rating limits; avoid immersion in liquids other than water samples; ensure battery compartment is properly sealed before use .
-
Electrode Handling: The glass pH bulb is fragile; handle with care to prevent breakage; do not touch the platinum sensing elements with fingers; avoid scrubbing with abrasive materials on any sensing surfaces .
-
Electrode Storage: Store electrode with protective cap in place; keep the pH sensing bulb moist using 3 mol KCl storage solution; never store dry .
-
Calibration Verification: Calibrate daily or before critical use using fresh calibration standards appropriate for the expected measurement range for each parameter .
-
Sample Compatibility: Rinse electrode thoroughly with distilled water between different samples to prevent cross-contamination; ensure there are no air bubbles trapped on the electrode surfaces during measurement .
-
Battery Safety: Use only AAA alkaline batteries; do not mix old and new batteries; remove batteries for long-term storage to prevent leakage; dispose of used batteries properly .
-
Environmental Protection: Dispose of calibration standards, sample vials, and other consumables according to local environmental regulations; buffer solutions and conductivity standards contain salts and may be disposed of via standard laboratory waste streams .
-
Self-Diagnosis: Run power-on self-diagnosis function before each use to verify system integrity .
-
Training: Only trained laboratory personnel should operate the DPC1 Pen Meter for water quality testing applications .
2. FIRST AID MEASURES
-
Calibration Standard Exposure: If pH buffer solution, conductivity standard, or ORP standard solution splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water .
-
Sample Splash: If biological or chemical sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water .
-
Glass Breakage: If the pH glass bulb breaks, carefully collect fragments using forceps; dispose in sharps container; inspect sample for glass contamination before further use .
-
Electrical Malfunction: If the meter shows signs of electrical malfunction (erratic readings, display issues, battery leakage), remove batteries immediately; do not attempt to operate; contact service personnel .
-
Electrode Damage: If the electrode is damaged, discontinue use; replace with a new DPC1-S combined probe .
-
Battery Leakage: If battery leakage occurs, remove batteries immediately, clean the battery compartment with a dry cloth, dispose of batteries properly; avoid skin contact with leaked electrolyte .
3. FIRE FIGHTING MEASURES
-
Flammability: The plastic housing and carrying case are combustible; may melt or burn if exposed to flame or high heat .
-
Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for fires involving plastic components .
-
Fire Response: Remove batteries if safe to do so; do not use water on electrical fire; evacuate areas if fire cannot be quickly contained .
Related products
Anti-Streptol Olysin O Titer (ASOT)
$24.23
Anti-Streptol Olysin O Titer (ASOT) is a quantitative or semi-quantitative serological test (latex agglutination, turbidimetry, nephelometry, or ELISA) for detecting antibodies against streptolysin O, an exotoxin produced by Group A Streptococcus. Elevated or rising titers indicate recent streptococcal infection and are essential for diagnosing post-streptococcal sequelae including acute rheumatic fever (Jones criteria) and post-streptococcal glomerulonephritis. The test requires serum samples; acute and convalescent (2-4 weeks apart) with fourfold rise confirms recent infection. Reference range typically <200-250 Todd units/mL (adults), varies by age and population. Primary clinical applications include diagnosis of Group A streptococcal infections, acute rheumatic fever evaluation, post-streptococcal glomerulonephritis diagnosis, differentiation of acute vs. past infection, evaluation of unexplained arthritis or carditis, pediatric inflammatory conditions (PANDAS), and monitoring disease activity in rheumatic fever. Critical safety precautions include proper timing of acute and convalescent samples, awareness of false negatives/positives, clinical correlation for diagnosis, and standard biohazard precautions. Essential test for rheumatology, nephrology, cardiology, and infectious disease practice.
Blood Grouping kit
$1.00
A Blood Grouping Kit is a Class II medical device (FDA-cleared/CE-marked) containing monoclonal antibodies (Anti-A, Anti-B, Anti-D) and control reagents for determining ABO blood group and Rh factor by agglutination method. The kit includes color-coded reagent vials, reaction cards or slides, mixing sticks, lancets, and capillary pipettes. Test time 2-5 minutes (slide method) or 15-30 minutes (tube method). Interpretation based on agglutination pattern: Anti-A positive = group A; Anti-B positive = group B; both positive = group AB; both negative = group O; Anti-D positive = Rh positive; Anti-D negative = Rh negative. Primary clinical applications include pre-transfusion compatibility testing, prenatal and neonatal testing (Rh incompatibility prevention), preoperative blood typing, blood donor screening, and emergency blood typing. Critical safety precautions include refrigerated storage (2-8°C), proper disposal of lancets in sharps containers, universal precautions for blood samples, and confirmation with reverse typing when possible. Essential kit for transfusion medicine, obstetrics, surgery, and emergency care.
Coagulation Analyzer
$1.00
A Coagulation Analyzer is a compact, automated instrument designed for performing essential tests that evaluate the blood's clotting ability. It accurately measures key parameters such as Prothrombin Time (PT/INR), Activated Partial Thromboplastin Time (aPTT), Thrombin Time, and Fibrinogen, which are critical for monitoring anticoagulant therapy (warfarin, heparin), diagnosing bleeding disorders, and assessing surgical risk. With its photometric detection and user-friendly operation, it delivers reliable results for small to medium-volume laboratories, clinics, and hospital wards. Its role in ensuring safe and effective patient management in thrombosis and hemostasis makes it a vital tool in clinical diagnostics.
ESR Tubes Glass
$1.00
ESR Tubes Glass are specialized glass tubes (300 mm length, 2.55 mm bore diameter, graduated 0-200 mm in 1 mm intervals) meeting ICSH and CLSI Westergren specifications for measuring erythrocyte sedimentation rate, a non-specific marker of inflammation. Used with citrated or diluted EDTA blood, filled to exactly 200 mm, placed vertically in Westergren stand, and read at 60 minutes. Primary clinical applications include determination of ESR for diagnosing and monitoring inflammatory conditions (infections, autoimmune disorders, malignancies), monitoring disease activity in rheumatoid arthritis, assessment of temporal arteritis and polymyalgia rheumatica, evaluation of infection and inflammatory response, screening for occult inflammatory conditions, and monitoring chronic inflammatory diseases (SLE, IBD, vasculitis). Critical safety precautions include handling glass tubes carefully to avoid breakage (sharps hazard), proper disposal in sharps containers as biohazardous waste, ensuring vertical alignment and constant temperature (18-25°C), reading at exactly 60 minutes, and avoiding air bubbles and vibration. Essential consumable for reference Westergren ESR testing in clinical laboratories.
Finecare Analyzer
$1.00
The Finecare Analyzer is a Class II medical device (FDA-cleared, CE-marked) fluorescence immunoassay system manufactured by Wondfo Biotech for quantitative detection of cardiac markers (troponin I, CK-MB, myoglobin), inflammatory markers (CRP, procalcitonin), thyroid hormones (TSH, FT3, FT4), diabetes markers (HbA1c), reproductive hormones (LH, FSH, prolactin), tumor markers (AFP, CEA, PSA), and infectious disease markers. Features include time-resolved fluorescence technology, color touchscreen interface, built-in printer (select models), USB/Ethernet connectivity, and internal rechargeable battery for portable use. Test time 3-15 minutes, sample volume 50-100 µL (whole blood, serum, plasma). Primary clinical applications include rapid diagnosis of acute myocardial infarction in chest pain patients, early detection of sepsis and bacterial infections, thyroid disorder diagnosis and monitoring, long-term glycemic control assessment in diabetes, fertility and reproductive health evaluation, cancer screening and surveillance, and infectious disease testing in endemic and clinical settings. Critical safety precautions include proper test cartridge storage (2-8°C), regular quality control, biohazard safety protocols, and operator training. Essential point-of-care testing system for hospitals, clinics, and remote healthcare facilities requiring rapid, quantitative results.
Fridge Thermometer
$1.00
A Fridge Thermometer is a precision temperature monitoring device designed for continuous use inside medical and laboratory refrigerators and freezers. Its primary role is to safeguard the potency of vaccines, medications, and biological samples by ensuring storage temperatures remain within a critical specified range (e.g., +2°C to +8°C). Available in analog or digital formats, accurate models with memory functions are essential for compliance with cold chain protocols, requiring daily monitoring, logging, and regular calibration. It is a fundamental quality control tool in pharmacies, clinics, immunization centers, and laboratories.
H.pylori test kits (Antigen)
$1.00
H.pylori test kits (Antigen) are Class II medical devices (FDA-cleared/CE-marked) for rapid immunochromatographic or enzyme immunoassay detection of Helicobacter pylori antigens in stool specimens, enabling non-invasive diagnosis of active infection and post-treatment eradication confirmation. Test principles use monoclonal or polyclonal antibodies specific to H. pylori antigens, producing visible results in 10-20 minutes (rapid tests) or 1-2 hours (EIA). Sensitivity 90-98%, specificity 92-99% compared to gold standard methods. Primary clinical applications include rapid diagnosis of H. pylori infection in patients with dyspepsia, initial screening in uncomplicated dyspepsia (test-and-treat strategy), confirmation of active infection before therapy, post-treatment eradication confirmation (4-6 weeks after therapy), pediatric testing (preferred non-invasive method), screening in high-risk populations (family history of gastric cancer), and monitoring in patients with peptic ulcer disease or MALT lymphoma. Critical safety precautions include mandatory washout period (4 weeks off antibiotics, 2 weeks off PPIs) to avoid false negatives, proper specimen handling (universal precautions), refrigerated storage of kits (2-30°C), quality control verification, and disposal as biohazardous waste. Essential non-invasive tool for H. pylori management in gastroenterology and primary care.
VDRL Test For Syphilis
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties