Drying Oven
$1.00
WhatsApp Order
A Drying Oven is a forced-air heated cabinet used for dry heat sterilization of moisture-sensitive items and for thoroughly drying laboratory glassware and samples. Operating at high temperatures (up to 250°C), it is the method of choice for sterilizing powders, oils, and glass. Its key feature is uniform temperature distribution via a mechanical fan, which is essential for effective sterilization. Critical safety protocols include using extreme caution for thermal burns, never loading flammable materials, and allowing proper cooling. It is a vital piece of equipment in sterile processing and analytical laboratories where the complete absence of moisture is required.
Description
Drying Oven
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Sterilization of Heat-Stable, Non-Aqueous Materials
-
Primary Use: Provides dry heat sterilization for materials that would be damaged by moist steam, such as glassware (pipettes, Petri dishes, test tubes), powders, oils, greases, and certain sharp instruments, operating at higher temperatures (160-180°C) for longer periods than autoclaves.
-
How it helps: For the laboratory technician and sterile processing professional, the drying oven offers a sterilization method for items that cannot tolerate moisture—anhydrous powders that would clump, oils that would emulsify, sharp instruments that might corrode. For the patient receiving a medication compounded with sterile powders, or undergoing a procedure with sterile instruments, the drying oven ensures that items requiring anhydrous sterilization are rendered free of all microbial life, protecting them from infection.
2. Dehydration of Samples and Laboratory Glassware
-
Primary Use: Thoroughly dries cleaned glassware, ceramic, and metal equipment after washing to prevent spotting and water contamination in sensitive procedures, and removes moisture from clinical or environmental samples prior to analysis.
-
How it helps: For the laboratory scientist preparing for critical experiments, the drying oven ensures that glassware emerging from the wash cycle is completely dry—free from water spots that could interfere with spectrophotometry, free from moisture that could degrade sensitive reagents. For the researcher performing dry weight determinations on tissues, soils, or filters, the oven’s consistent temperature removes all moisture, providing accurate mass measurements that reflect true sample composition.
3. Heat Treatment and Curing
-
Primary Use: Anneals glassware to relieve stress, cures resins or adhesives used in lab equipment repair, and bakes on ceramic or polymer coatings.
-
How it helps: For the laboratory glassblower and equipment specialist, the drying oven provides controlled heat treatment that strengthens glass, prevents spontaneous breakage, and ensures repairs bond properly. For the researcher relying on custom glassware or repaired equipment, proper annealing and curing means their apparatus will perform reliably under experimental conditions, without catastrophic failure that could ruin months of work.
4. Evaporation of Solvents
-
Primary Use: Gently evaporates solvents from samples in open containers, though this is typically done in fume hoods.
-
How it helps: For the analytical chemist preparing samples for analysis, controlled evaporation concentrates analytes to detectable levels while removing interfering solvents. For the environmental scientist measuring pollutants, or the toxicologist screening for drugs, this gentle evaporation ensures that trace compounds are preserved and concentrated, enabling detection at clinically or environmentally relevant concentrations.
SECONDARY & SUPPORTIVE USES
1. Incubation at Elevated Temperatures: For the microbiologist studying thermophilic organisms or conducting biochemical reactions requiring temperatures above standard incubator ranges (55-80°C), the drying oven serves as a high-temperature incubator. For researchers exploring extremophile biology or developing heat-stable enzymes, this capability expands the experimental possibilities beyond conventional equipment.
2. Preparation of Laboratory Reagents: For the chemist preparing anhydrous compounds or drying chemical salts, the drying oven removes bound water to create reagents with precisely known compositions. For the researcher conducting moisture-sensitive reactions or preparing standards for analytical chemistry, properly dried reagents ensure experimental success and accurate results.
3. Quality Control Testing: For the medical device manufacturer and quality assurance professional, the drying oven assesses the effects of dry heat on device components, simulating sterilization conditions or accelerated aging. For patients who depend on medical devices that must withstand sterilization, or that must maintain integrity throughout their usable life, this testing ensures that products meet specifications and perform reliably when needed.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: An electrically heated, insulated cabinet that uses convection to circulate hot, dry air for sterilization, drying, and heat treatment.
-
Designation: Often called a "hot air oven" or "dry heat sterilizer."
-
Core Types by Airflow:
-
Gravity-Convection Oven: Relies on natural air currents; heat rises from the bottom, creating uneven temperature zones. Less expensive but less uniform.
-
Forced-Air (Mechanical-Convection) Oven: Uses a fan to actively circulate air, providing rapid heat transfer and exceptional temperature uniformity (±1-2°C throughout the chamber). This is the standard for sterilization and critical drying.
-
-
Core Components:
-
Insulated Chamber: Double-walled with high-temperature insulation (e.g., mineral wool). Interior is stainless steel or aluminum.
-
Heating Elements: Electric heating coils.
-
Circulation Fan: For forced-air models.
-
Digital Controller: Microprocessor-based PID controller for precise temperature setting and stability.
-
Temperature Sensor: Thermocouple or RTD.
-
Timer: For automated cycle control.
-
Vent: Often includes an adjustable vent to allow moisture vapor to escape during drying cycles.
-
Door: Insulated door with a high-temperature gasket.
-
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Temperature Range: Typically from ambient +10°C to 250°C or higher. Sterilization cycles are standardized at 160°C for 120 minutes, 170°C for 60 minutes, or 180°C for 30 minutes.
-
Temperature Uniformity: Critical for sterilization. Forced-air ovens can achieve uniformity within ±1°C to ±5°C of setpoint.
-
Heat Recovery Time: Time to return to setpoint after door opening.
-
Chamber Volume: Ranges from small 20L benchtop models to large 500L+ floor-standing cabinets.
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: Robust, often with stainless steel exterior and interior for durability and cleanability.
-
Shelving: Multiple adjustable, perforated wire shelves for optimal air circulation.
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: When used for sterilization, it is a Class II medical device. For general drying, it is Class I laboratory equipment.
-
Over-Temperature Protection: Independent redundant thermostat (often called a "hi-limit" controller) that cuts power if the primary controller fails.
-
Safety Certification: Should have electrical safety certifications (e.g., CE, UL).
-
Validation: Sterilization ovens require validation (IQ/OQ/PQ) and routine monitoring with biological indicators (Bacillus atrophaeus spores) and chemical indicators.
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: The oven itself is a fixed piece of equipment. Processed items are stored in clean, dry conditions.
-
Placement: Place on a stable, level, heat-resistant surface with ample clearance for ventilation. Keep away from flammable materials.
-
Loading: Do not overload. Arrange items to allow free air circulation around them. Do not place items directly on the chamber floor; use shelves.
-
Cleaning: Regularly vacuum or wipe out the interior to remove dust and debris. Spills should be cleaned immediately.
-
Calibration: Temperature should be calibrated at least annually using NIST-traceable probes placed in multiple locations within the chamber.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Essential in hospital Central Sterile Supply Departments (CSSD) for processing specific heat-stable items, in microbiology and chemistry laboratories for drying glassware, and in pharmaceutical industries for sterilizing powders and oils.
-
Clinical Role: Provides a critical alternative to steam sterilization for moisture-sensitive instruments and materials, and ensures moisture-free conditions for accurate analytical procedures.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Extreme Heat Hazard: ALL external and internal surfaces become extremely hot during operation and for a long time after. Always use high-temperature thermal mitts. Post clear warning signs.
-
Fire Hazard: NEVER use to dry or heat flammable, combustible, or explosive materials (e.g., organic solvents, nitrocellulose). Know the auto-ignition temperature of materials placed inside.
-
Proper Loading: Use only heat-stable materials (glass, metal, certain plastics). Plastics like polypropylene may be okay at lower temperatures; polystyrene will melt.
-
Ventilation: Ensure the room is well-ventilated, especially when drying items that release moisture or odors.
-
Cooling: Allow items and the oven to cool significantly before handling. Sudden temperature changes can cause glass to shatter.
2. FIRST AID MEASURES
-
Thermal Burn: Immediately cool the affected area with cool (not cold) running water for at least 20 minutes. Remove constrictive items. Seek medical attention for anything more than a minor superficial burn.
-
Fire Inside Oven: DO NOT OPEN THE DOOR. Opening feeds oxygen to the fire. Turn off the heat and unplug the oven if safe. Allow it to cool while contained. Use a fire extinguisher through vents if possible, or let it smother. For a large fire, evacuate and call emergency services.
-
Electrical Fault: If the unit sparks, smokes, or smells of burning, turn off and unplug immediately. Do not use until inspected by a qualified technician.
3. FIRE FIGHTING MEASURES
-
Flammability: Insulation, wiring, and plastic components are combustible.
-
Extinguishing Media: For an electrical fire involving the oven itself, use a CO2 (Class C) fire extinguisher. For fires involving contents, use an appropriate extinguisher based on the fuel. Do not use water on an electrical fire.
Related products
Anti-Streptol Olysin O Titer (ASOT)
$24.23
Anti-Streptol Olysin O Titer (ASOT) is a quantitative or semi-quantitative serological test (latex agglutination, turbidimetry, nephelometry, or ELISA) for detecting antibodies against streptolysin O, an exotoxin produced by Group A Streptococcus. Elevated or rising titers indicate recent streptococcal infection and are essential for diagnosing post-streptococcal sequelae including acute rheumatic fever (Jones criteria) and post-streptococcal glomerulonephritis. The test requires serum samples; acute and convalescent (2-4 weeks apart) with fourfold rise confirms recent infection. Reference range typically <200-250 Todd units/mL (adults), varies by age and population. Primary clinical applications include diagnosis of Group A streptococcal infections, acute rheumatic fever evaluation, post-streptococcal glomerulonephritis diagnosis, differentiation of acute vs. past infection, evaluation of unexplained arthritis or carditis, pediatric inflammatory conditions (PANDAS), and monitoring disease activity in rheumatic fever. Critical safety precautions include proper timing of acute and convalescent samples, awareness of false negatives/positives, clinical correlation for diagnosis, and standard biohazard precautions. Essential test for rheumatology, nephrology, cardiology, and infectious disease practice.
Brucella Set
$1.00
A Brucella Set is a comprehensive serological test system (Class II medical device, CE-marked/FDA-cleared) for qualitative and quantitative detection of antibodies against Brucella species (B. abortus, B. melitensis, B. suis, B. canis) using multiple methodologies including tube agglutination, slide agglutination, and 2-mercaptoethanol (2-ME) testing. The set includes killed, stained Brucella antigens, positive and negative controls, dilution tubes, reaction cards, and 2-ME reagent for IgM/IgG differentiation. Diagnostic titer ≥1:160 or fourfold rise confirms brucellosis. Primary clinical applications include diagnosis of brucellosis in endemic regions (undulant fever, night sweats, arthralgia), fever of unknown origin investigation, occupational health screening in high-risk workers (veterinarians, farmers, slaughterhouse workers), diagnosis of focal complications (sacroiliitis, spondylitis, meningitis, endocarditis), treatment monitoring (fourfold decline indicates response), outbreak investigation, and public health surveillance. Critical safety precautions include handling all samples in biosafety cabinet (Brucella is highly infectious via aerosol), 2-ME reagent toxicity (use fume hood), awareness of prozone phenomenon (serial dilutions essential), cross-reactions with other Gram-negative bacteria, and mandatory reporting to public health authorities. Essential test for brucellosis diagnosis in endemic regions and occupational health settings.
Centrifuge Tubes
$1.00
Centrifuge Tubes are specialized disposable containers (polypropylene) designed to withstand high centrifugal forces (up to 30,000 x g) for separating biological fluids based on density. Available in microcentrifuge sizes (0.2-2.0 mL), conical tubes (15 mL, 50 mL), and larger volumes (100-500 mL). Features include leak-proof screw caps with O-rings (conical tubes), snap caps (microcentrifuge tubes), graduated volume markings, writing areas, and sterile/non-sterile options. Certified RNase/DNase-free, pyrogen-free, and autoclavable. Primary clinical applications include blood component separation (serum/plasma), urine sediment preparation, microbiology sample concentration, molecular biology (DNA/RNA extraction), cell culture processing, protein/enzyme analysis, and viral load testing. Critical safety precautions include never exceeding maximum RCF rating, proper balancing by weight, secure cap tightening, inspection for cracks, and disposal as biohazardous waste. Essential consumable in every clinical, research, and industrial laboratory.
Electric Centrifuge
$1.00
An Electric Centrifuge is a Class I medical device that uses rapid rotation to separate fluids of different densities, essential in clinical laboratories for processing blood, urine, and other biological specimens. Available in benchtop, refrigerated, microcentrifuge, hematocrit, and high-speed models with fixed-angle, swinging-bucket, or vertical rotors. Speed range 1,000-30,000+ RPM with RCF up to 65,000+ x g. Features include brushless induction motor, digital controls, imbalance detection, lid lock safety, and programmable protocols. Primary clinical applications include separation of serum/plasma for chemistry and hematology testing, urine sediment analysis for microscopy, platelet-rich plasma (PRP) preparation for regenerative medicine, concentration of bacteria for microbiology, cytology fluid analysis, blood banking, and molecular biology sample processing. Critical safety precautions include proper balancing of loads (weight matching), use of sealed rotors for biohazardous samples, regular rotor inspection for corrosion or cracks, never exceeding maximum rated speed, and never opening lid during operation. Essential equipment in clinical, research, and teaching laboratories.
Microscope Bulb
$1.00
A Microscope Bulb is a specialized halogen or LED lamp that serves as the essential illumination source for clinical and laboratory microscopes. Providing the bright, stable, and color-corrected light required for diagnostic visualization of specimens, it is a critical consumable component. Its technical specifications—voltage, wattage, base type, and filament alignment—must precisely match the microscope model. Proper handling (using gloves to avoid oil contamination) and adherence to safety protocols (allowing cooling, disconnecting power) are crucial for safe replacement and optimal bulb lifespan. Maintaining spares is vital to prevent operational downtime in diagnostic laboratories.
PRECIL Series
$1.00
The PRECIL Series, originally developed by Beijing Precil and now associated with Mindray, comprises specialized coagulation analyzers and hemorheology analyzers for clinical laboratory testing. Coagulation analyzers measure PT, APTT, fibrinogen, TT, D-dimer, factor assays, and thrombophilia markers for diagnosing bleeding disorders, monitoring anticoagulant therapy, and assessing liver function. Hemorheology analyzers measure whole blood viscosity, plasma viscosity, erythrocyte aggregation, and deformability for evaluating hyperviscosity syndromes, sickle cell disease, diabetes, and cardiovascular disorders. The series includes specialized cleaning solutions and reagents (such as PLS cleaner) for maintaining analyzer performance and ensuring accurate results. Features include automated sample processing, color touchscreen interface, LIS connectivity, and comprehensive quality control programs. Primary clinical applications include coagulation testing for preoperative assessment, anticoagulant monitoring, DIC diagnosis, thrombophilia workup, and hemorheology assessment for conditions affecting blood flow. Essential laboratory instrumentation for hematology, coagulation, and specialized testing in hospital laboratories, reference laboratories, and research facilities.
Urinalysis strips
$1.00
Urinalysis Strips are Class II medical devices (FDA-cleared) consisting of plastic strips with multiple reagent-impregnated pads for simultaneous semi-quantitative detection of urine analytes including leukocytes, nitrites, urobilinogen, protein, pH, blood, specific gravity, ketones, bilirubin, and glucose. Results read by visual comparison to color chart at specified times (30-120 seconds). Primary clinical applications include routine health screening, urinary tract infection diagnosis, diabetes screening and monitoring, kidney disease assessment (proteinuria), hematuria detection, liver function evaluation, and pregnancy monitoring (preeclampsia screening). Critical safety precautions include proper specimen collection (fresh urine), storage at 15-30°C in original container with desiccant, protection from humidity, reading at exact specified times, awareness of interfering substances (ascorbic acid), and confirmation of abnormal results with quantitative tests. Essential screening tool in primary care, emergency medicine, nephrology, urology, and obstetrics.
Vacutainer (EDTA/PLAIN)
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties