Portable Analyzer – Multi-Parameter (DPC10)

WhatsApp Order
The Portable Analyzer (DPC10) is a multi-parameter, high-precision analytical instrument designed for the rigorous demands of water quality monitoring in clinical, pharmaceutical, and environmental settings. This portable meter measures pH (0-20 pH with ±0.002 accuracy), ORP (±1999.9 mV), Conductivity (0-2000 mS/cm), TDS, Salinity, Resistivity, and Temperature, consolidating multiple critical tests into one device.
Featuring a 3.5-inch TFT color screen and a user-friendly UI, the  Portable Analyzer (DPC10) simplifies on-site testing of dialysis water, pharmaceutical purified water loops, and wastewater discharge. The meter supports GLP-compliant data management by storing up to 3,000 data sets with complete timestamps and offers PC software for user hierarchy management and data traceability. Powered by a rechargeable lithium battery with a Type-C charging port and rated IP57 for dust/water resistance, it is built for reliable field use.
Supplied with a hard carrying case, ATC pH electrode, conductivity electrode, full sets of calibration standards, and a charging cable, the  Portable Analyzer (DPC10) is a comprehensive solution for ensuring the quality and safety of water used in patient treatments and drug manufacturing. For the patient, this rigorous monitoring helps ensure that critical treatment fluids meet stringent safety standards, preventing potential harm from improperly treated water.
Description

Portable Analyzer – Multi-Parameter (DPC10)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Comprehensive Water Quality Monitoring for Dialysis and Pharmaceutical Applications
  • Primary Use: Provides a portable, multi-parameter benchtop/field analyzer capable of measuring pH, ORP (Oxidation-Reduction Potential), Conductivity, TDS (Total Dissolved Solids), Salinity, Resistivity, and Temperature with high precision across automatic ranging scales.
  • How it helps: For dialysis technicians and water quality specialists, the DPC10 replaces multiple single-parameter meters, allowing a single device to verify the ionic purity, pH balance, and disinfection efficacy (ORP) of purified water and dialysis fluids. The 3.5-inch TFT color screen and IP57 dust/water resistance make it ideal for use in demanding utility environments. For the patient, this comprehensive monitoring ensures that the water used in renal replacement therapy meets all critical safety standards, preventing complications from improper dialysate composition.
2. Pharmaceutical Process Water and Cleaning Validation
  • Primary Use: Supports the validation and routine monitoring of Water-for-Injection (WFI) and purified water loops, as well as verification of rinse cycles in Clean-in-Place (CIP) systems.
  • How it helps: For the Pharmaceutical QA/QC chemist, the DPC10’s ability to measure pH, conductivity, and resistivity with high accuracy (e.g., pH ±0.002, Conductivity ±0.5% FS) allows a single device to verify water quality at multiple critical control points. The analyzer stores up to 3,000 GLP-compliant data sets with timestamps and offers PC software for user management and data traceability. For the patient, this data integrity ensures that injectable medications and IV solutions are free from ionic contaminants, upholding product safety.
3. Industrial and Environmental Compliance Monitoring
  • Primary Use: Designed for on-site measurement of pH, ORP, and conductivity in industrial wastewater treatment, cooling towers, and environmental discharge to assess chemical balance and treatment efficacy.
  • How it helps: For hospital facility engineers and environmental safety officers, the DPC10’s portable design and rechargeable lithium battery (Type-C charging) allow for easy spot-checking of wastewater discharge points to ensure compliance with environmental permits. The ability to measure Resistivity (up to 100.0 MΩ·cm) is also crucial for diagnosing the health of reverse osmosis membranes. For the patient and community, consistent monitoring of hospital wastewater and water systems helps prevent environmental contamination and ensures public health protection.
4. Dissolved Oxygen Measurement (DPCD10 Model)
  • Primary Use: The  Portable Analyzer (DPC10) variant of this analyzer adds polarographic dissolved oxygen (DO) measurement capability for assessing oxygen levels in aqueous samples.
  • How it helps: For researchers and aquaculture facility managers, the DO module expands the analyzer’s utility for monitoring biological oxygen demand (BOD) in wastewater treatment, assessing aeration in bioreactors, and ensuring optimal conditions for aquatic research animals (e.g., zebrafish facilities). For the patient involved in clinical research, this helps ensure the integrity of studies that depend on precise water quality conditions for animal models.

SECONDARY & SUPPORTIVE USES

1. Research Aquaculture and Zebrafish Facility Management: Monitors pH, conductivity, and dissolved oxygen levels in aquatic animal housing facilities within research institutions to ensure optimal environmental conditions.
  • Hydroponic Nutrient Solution Management: Checks pH and conductivity (EC) of nutrient solutions in controlled environment agriculture to optimize mineral uptake for test crops.
  • Food and Beverage Production Verification: Used in quality control to verify the pH and concentration of cleaning solutions and rinse water in food processing QA/QC workflows.
  • Boiler and Steam Generator Diagnostics: Provides rapid assessment of boiler water pH and conductivity to control blowdown cycles and prevent costly corrosion or scaling in hospital steam plants.
  • Educational Laboratory Training: Serves as a comprehensive teaching tool for demonstrating electrochemistry and water quality measurement principles in clinical laboratory science programs.
  • Swimming Pool and Hydrotherapy Water Testing: Measures pH and ORP levels in hospital hydrotherapy pools and spas to ensure chlorine or other oxidizers remain at effective concentrations for microbial control.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A portable, multi-parameter benchtop/field analyzer designed for high-precision measurement of pH, ORP, Conductivity, TDS, Salinity, Resistivity, Temperature (and optional DO) with an intelligent operating system.
  • Designation: DPC10 Portable Analyzer (Multi-Parameter), DPCD10 (with DO), DLAB DPC10, Multi-Parameter Water Quality Analyzer .
  • Key Components:
    • Instrument Meter: Portable housing with a 3.5-inch TFT LCD color screen, IP57 rating, and Type-C charging.
    • pH Electrode: Plastic ATC pH electrode D201T-H (K=1.0) .
    • Conductivity Electrode: Plastic ATC Cond electrode DCON201T (K=1.0) .
    • ORP Electrode: Optional, model DORP301 (plastic body) .
    • DO Electrode (DPCD10): Polarographic dissolved oxygen electrode DDO01-2M-H .
    • Accessories: Hard carrying case, calibration standards (pH buffers 4.00/6.86/9.18, conductivity 146.6µS/1408µS/12.85mS/cm), rechargeable lithium battery (DH10-LI01), Type-C cable.

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Measurement Parameters: pH/mV. | mV(ORP). | Cond/TDS/Sal./Res. (DO optional).
  • pH Measurement Range: (-2.000 ~ 20.000) pH.
  • pH Resolution: 0.1/0.01/0.001.
  • pH Accuracy: ±0.002pH ±1 digit.
  • pH Calibration: 1~3 points auto calibration .
  • ORP Measurement Range: (-1999.9 - +1999.9) mV.
  • ORP Resolution: 0.1/1.
  • ORP Accuracy: ±0.03% F.S ±1 digit.
  • Conductivity Range: 0~2000.0 mS/cm auto-ranging (0~200 mS/cm support range).
  • Conductivity Accuracy: ±0.5% FS ±1 digit.
  • TDS Range: 0~100.0 g/L (coefficient adjustable).
  • Resistivity Range: 5.000 Ω·cm ~ 100.0 MΩ·cm.
  • Salinity Range: 0~100 ppt.
  • Temperature Range: (0.0~100.0) °C / (32.0~212.0)°F.
  • Temperature Accuracy: ±0.2°C .
  • Data Storage: 3000 groups (parameter, value, temperature, date/time).
  • Display: 3.5-inch TFT LCD color screen.
  • Power Supply: Rechargeable lithium battery.
  • Charging Port: Type-C/USB (EU standard).
  • Protection Class: IP57 (dustproof and waterproof against temporary immersion).

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Rugged, ergonomic handheld design with a hard carrying case for transport and storage.
  • User Interface: New UI design and intelligent operation system with functions for timed measurement, parameter setting, and data locking.
  • Calibration: Supports electrode calibration and standard solution calibration for conductivity; multi-point automatic calibration for pH.
  • Connectivity: Type-C charging port and PC connectivity for data export and advanced user/device management.
  • GLP Compliance: Supports GLP documentation with operation logs, user hierarchy management, and data printing.
  • Electrode Compatibility: Compatible with dedicated DLAB pH, conductivity, ORP, and DO electrodes.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: IVD (In Vitro Diagnostic) preparatory equipment; complies with GLP standards for data management.
  • Protection Class: IP57 (Dustproof and waterproof against temporary immersion).
  • Certifications: CE, ISO 9001:2015.
  • Power Management: Built-in low-power management, automatic power-off, and power failure protection functions.

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store the meter in its hard carrying case in a clean, dry environment. Electrodes should be stored according to manufacturer instructions (typically with the sensing elements moist).
  • Electrode Maintenance: Rinse electrodes with distilled water after each use. Do not touch or scrub the platinum black sensor surface on the conductivity electrode.
  • Calibration: Calibrate the meter daily or before critical use with fresh calibration standards appropriate for the expected measurement range.
  • Data Management: Use the PC software to export data, manage user permissions, and generate quality records for regulatory compliance.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: High-precision, multi-parameter water quality assurance for clinical dialysis centers, pharmaceutical manufacturing, hospital environmental monitoring, and industrial water treatment.
  • Clinical Role: A comprehensive tool for Pharmacy Quality Control, Hospital Engineering (Water Systems), Dialysis Unit technical staff, and Infection Control officers for verifying water safety and regulatory compliance.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Do not immerse the meter body in liquid, despite its IP57 rating.
  • Ensure the electrode sensing surfaces are clean and free of contamination before measurement.
  • Verify there are no air bubbles trapped on the conductivity electrode face during measurement.
  • Calibrate the meter at least daily or before critical use to ensure accurate readings across all parameters.
  • Use fresh calibration standards and do not return used standard solution to the original container.