Portable ORP Meter – Single Parameter (DORP10)

WhatsApp Order
The Portable ORP Meter (DORP10) is a rugged, high-precision analytical instrument designed for the critical task of monitoring Oxidation-Reduction Potential in water quality applications across clinical, pharmaceutical, and environmental settings . This single-parameter meter accurately measures ORP from -1999.9 mV to +1999.9 mV and includes a separate stainless steel temperature probe (DTEMP-02H) for Automatic Temperature Compensation (ATC), ensuring reliable readings regardless of sample temperature fluctuations .
Featuring a 3.5-inch TFT color screen and a user-friendly UI, the Portable ORP Meter (DORP10) simplifies on-site testing of disinfection efficacy in dialysis water systems, pharmaceutical purified water loops, and hospital wastewater discharge . The meter supports GLP-compliant data management by storing up to 3,000 data sets with complete timestamps and can be powered by a rechargeable lithium battery charged via a Type-C port .
Supplied with a hard carrying case, ORP electrode (DORP301), stainless steel temperature electrode, 222mV calibration standard, and a Type-C charging cable, the DORP10 is a comprehensive solution for ensuring the oxidative state of water used in patient treatments and drug manufacturing . For the patient, this rigorous monitoring helps ensure that critical treatment fluids meet stringent safety standards, preventing potential harm from improperly treated water.
Description

Portable ORP Meter – Single Parameter (DORP10)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Water Quality and Disinfection Efficacy Monitoring in Healthcare
  • Primary Use: Provides a portable, single-parameter meter for measuring Oxidation-Reduction Potential (ORP) in aqueous samples, ranging from -1999.9 mV to +1999.9 mV with ±0.03% F.S. accuracy .
  • How it helps: For infection control officers and dialysis technicians, the DORP10 is used to verify the oxidizing power of water treatment systems. Measuring ORP is a direct method to confirm the effectiveness of disinfection processes in purified water loops, dialysis water systems, and hospital plumbing, ensuring they are actively combating microbial growth. The 3.5-inch TFT color screen provides clear, real-time data, and the meter’s IP57 dustproof/waterproof rating allows for safe use in these demanding utility environments . For the patient, this ensures that the water used in treatments like dialysis is free from harmful microorganisms and meets critical safety standards.
2. Process Monitoring and Quality Assurance in Pharmaceutical Production
  • Primary Use: Used to monitor and control ORP levels in various pharmaceutical and bioprocessing applications, such as monitoring antioxidant capacity in formulations and controlling redox reactions in chemical synthesis .
  • How it helps: For the pharmaceutical QA/QC chemist, the DORP10 provides a portable method to verify the oxidative state of purified water systems and the stability of sensitive pharmaceutical ingredients. It includes a stainless steel temperature electrode (DTEMP-02H) for automatic temperature compensation (ATC), ensuring accurate readings across varying sample conditions . Its ability to store 3000 data sets with a timestamp ensures full GLP compliance and traceability for quality audits . For the patient, this helps guarantee that medications and IV solutions are free from ionic contaminants and degradation, ensuring product safety and efficacy.
3. Environmental and Industrial Effluent Compliance
  • Primary Use: Designed for on-site ORP measurement in industrial wastewater treatment, environmental remediation, and agricultural runoff monitoring to assess oxidation/reduction states and treatment efficacy .
  • How it helps: For hospital facility engineers and environmental safety officers, the DORP10’s portable design allows for easy, rapid spot-checking of wastewater discharge points to ensure compliance with environmental discharge permits. The device’s robust construction, rechargeable lithium battery, and Type-C charging port make it a reliable tool for field use . For the patient and the surrounding community, consistent monitoring of hospital wastewater helps ensure that potentially harmful substances are neutralized before being released into the public water system.

SECONDARY & SUPPORTIVE USES

1. Disinfection Control in Hydrotherapy and Spa Pools: Monitors ORP levels in hospital hydrotherapy pools, spas, and cooling towers to ensure chlorine or other oxidizers remain at effective concentrations for microbial control.
2. Agricultural and Aquaculture Research: Measures ORP in hydroponic nutrient solutions, aquaculture tanks (e.g., zebrafish facilities), and soil studies to assess system health and redox status for research purposes.
3. Food and Beverage Production Verification: Used in quality control for food and beverage production, such as monitoring sanitizer strength in CIP (Clean-In-Place) systems or assessing the antioxidant status of products.
4. Educational and Laboratory Training: A practical tool for teaching the principles of electrochemistry, redox reactions, and water quality analysis in clinical laboratory science and chemistry programs.
5. General Laboratory Redox Measurement: Serves as a reliable benchtop ORP meter for any laboratory requiring precise measurement of oxidation-reduction potential in chemical or biological samples.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A portable, single-parameter benchtop/field meter designed for high-accuracy measurement of Oxidation-Reduction Potential (ORP) and temperature, with automatic temperature compensation.
  • Designation: DORP10, DORP10 Portable ORP Meter (Single Parameter), DLAB DORP10, Portable ORP Meter .
  • Key Components:
    • Instrument Meter: Portable housing with a 3.5-inch TFT LCD color screen, IP57 rating, and Type-C charging .
    • ORP Electrode: Plastic body ORP electrode (model DORP301) with a 1-meter cable .
    • Temperature Electrode: Stainless steel temperature electrode (model DTEMP-02H) with a 1-meter cable .
    • Accessories: Hard carrying case (33×27.2×8.2 cm), calibration standard (222mV, 50mL), rechargeable lithium battery (pre-installed), and Type-C charging cable .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Measurement Parameters: ORP (mV) and Temperature (°C/°F).
  • ORP Measurement Range: -1999.9 mV to +1999.9 mV .
  • ORP Resolution: 0.1/1 (selectable) .
  • ORP Accuracy: ±0.03% F.S. ±1 digit .
  • Temperature Measurement Range: 0.0 to 100.0°C (32.0 to 212.0°F) .
  • Temperature Accuracy: ±0.2°C .
  • Data Storage: 3000 data sets (parameter, measured value, temperature, date/time) .
  • Display: 3.5-inch TFT LCD color screen .
  • Power Supply: Rechargeable lithium battery (model DH10-LI01) .
  • Charging Port: Type-C (EU standard) .
  • Protection Class: IP57 (dustproof and waterproof against temporary immersion) .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Rugged, ergonomic housing with an intuitive UI interface for easy navigation .
  • Calibration: Supports electrode calibration and standard solution calibration using the supplied 222mV ORP standard .
  • Data Management: Timer measurement, parameter setting, data lock function, and automatic power-off for battery conservation .
  • Portability: Compact hard case and IP57 rating allow for safe transport and use in field or industrial environments .
  • Compliance: Meets GLP data management standards and ISO9001:2015 quality system .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: IVD preparatory equipment; complies with GLP data management standards .
  • Certifications: ISO9001:2015, CE .
  • Protection Class: IP57 (Dustproof and waterproof against temporary immersion) .
  • Electrical Safety: Low-voltage operation with rechargeable battery; Type-C charging.

5. STORAGE & HANDLING ATTRIBUTES

  • Electrode Maintenance: Rinse the ORP electrode with distilled water after each use. The plastic body is durable and chemical-resistant.
  • Temperature Electrode: The stainless steel temperature electrode should be wiped clean and stored dry.
  • Storage: Store the meter in its hard carrying case in a clean, dry environment.
  • Calibration: Calibrate the meter periodically or before critical use with the supplied 222mV ORP standard solution.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: High-accuracy water quality assurance for disinfection efficacy in clinical dialysis centers, pharmaceutical manufacturing, and hospital environmental monitoring.
  • Clinical Role: A critical tool for Hospital Infection Control, Pharmacy Quality Control, and Dialysis Unit technical staff for verifying water safety and regulatory compliance .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Do not immerse the meter body in liquid, despite its IP57 rating.
  • Ensure the ORP electrode's sensing surface is clean and free of contamination before measurement.
  • Calibrate the meter at least daily or before critical use to ensure accurate readings.