Reinforced ET Tubes Cuffed
$1.00
WhatsApp Order
Reinforced ET Tubes Cuffed are kink-resistant endotracheal tubes with embedded wire reinforcement that maintains patency during prone positioning, neurosurgery, and long-term ventilation. The inflatable cuff provides aspiration protection and enables positive pressure ventilation. Essential for procedures requiring non-standard patient positioning, difficult airway management, and prolonged mechanical ventilation, they provide a reliable, durable airway in challenging clinical scenarios.
Description
Reinforced ET Tubes Cuffed
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Airway Management in Prone and Lateral Positioning
-
Primary Use: Provides a kink-resistant airway for patients undergoing procedures requiring prone, lateral, or other positioning where standard endotracheal tubes may kink or obstruct. The embedded wire reinforcement maintains patency regardless of patient position or tube angulation.
-
How it helps: For the anesthesiologist and surgical team, reinforced tubes provide reliable airway patency during procedures requiring non-standard positioning—ensuring that ventilation continues uninterrupted even when the patient is turned or positioned. For the patient undergoing spinal surgery, prone positioning, or lateral procedures, this means a secure airway that remains patent regardless of position.
2. Long-Term Mechanical Ventilation in ICU
-
Primary Use: Used for patients requiring prolonged mechanical ventilation where tube durability and resistance to kinking are essential. The reinforced construction withstands the rigors of long-term intubation and patient movement.
-
How it helps: For the intensivist and respiratory therapist, reinforced tubes provide a durable airway that maintains patency despite patient movement, coughing, or repositioning—reducing the risk of unplanned extubation or airway obstruction. For the critically ill patient requiring prolonged ventilation, this means a more secure, reliable airway throughout their ICU stay.
3. Neurosurgical and Head Positioning Procedures
-
Primary Use: Essential for neurosurgical procedures where the head is positioned in pins, Mayfield clamps, or other fixation devices that may compress or kink standard tubes. The reinforced design maintains patency regardless of head position.
-
How it helps: For the neurosurgeon and anesthesiologist, reinforced tubes provide airway security during procedures requiring extreme head positioning—ensuring that ventilation is not compromised by surgical positioning. For the patient undergoing craniotomy or other neurosurgical procedures, this means a safe, patent airway throughout the operation.
4. Laser Airway Surgery
-
Primary Use: Some reinforced tubes are designed with specialized materials for laser airway surgery, providing resistance to laser-induced ignition while maintaining kink resistance.
-
How it helps: For the otolaryngologist and anesthesiologist performing laser laryngeal surgery, reinforced tubes provide a secure airway that resists kinking while offering laser-safe properties. For the patient undergoing laser airway procedures, this means a safe airway that minimizes the risk of airway fire.
5. Difficult Airway Management
-
Primary Use: Used in patients with known difficult airways where tube manipulation and positioning may be challenging, providing a kink-resistant conduit that maintains patency despite tube bending or manipulation.
-
How it helps: For the anesthesiologist managing a difficult airway, reinforced tubes provide confidence that the airway will remain patent even when the tube is manipulated, positioned, or secured in non-standard orientations. For the patient with a difficult airway, this ensures a reliable airway once established.
SECONDARY & SUPPORTIVE USES
1. Transport of Intubated Patients: Provides durable, kink-resistant airway for patient transport, reducing the risk of obstruction during movement.
2. Head and Neck Surgery: Used in surgical procedures where the surgical field or positioning may compromise standard tubes.
3. Bronchoscopy and Airway Procedures: Allows passage of bronchoscopes while maintaining airway patency.
4. Burn and Trauma Patients: Used in patients with facial burns or trauma where tube positioning may be compromised.
5. Pediatric Applications: Smaller reinforced tubes available for children requiring durable airways.
6. Magnetic Resonance Imaging: MRI-compatible reinforced tubes available for patients undergoing MRI procedures.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A reinforced endotracheal tube with embedded wire spiral for kink resistance and an inflatable cuff for airway sealing.
-
Designation: Reinforced ET Tube, Armored ET Tube, Wire-Reinforced Endotracheal Tube, Kink-Resistant Tube.
-
Key Components:
-
Reinforced Wall: Embedded stainless steel or nylon wire spiral within the tube wall.
-
Inflatable Cuff: High-volume, low-pressure cuff for tracheal sealing.
-
Pilot Balloon: Indicator balloon for monitoring cuff inflation.
-
Inflation Valve: One-way valve for cuff inflation with syringe.
-
Connector: Standard 15 mm connector for ventilator circuit attachment.
-
Depth Markings: Centimeter markings along the tube for accurate placement.
-
Radiopaque Line: Embedded line for radiographic confirmation.
-
Murphy Eye: Lateral eye at the distal tip to prevent complete obstruction.
-
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Sizes: 5.0 mm to 9.0 mm internal diameter; adult and pediatric sizes.
-
Reinforcement: Stainless steel or nylon spiral embedded in tube wall.
-
Kink Resistance: Maintains patency even when bent or positioned acutely.
-
Cuff Type: High-volume, low-pressure to minimize tracheal mucosal injury.
-
Cuff Pressure: Maintain between 20-30 cm H₂O to prevent mucosal ischemia.
-
Material: Medical-grade PVC with metal or nylon reinforcement.
-
Sterility: Ethylene oxide or gamma irradiation sterilized.
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: Flexible tube with internal reinforcement; maintains shape when bent.
-
Depth Markings: 1 cm intervals for precise positioning.
-
Connector: Standard 15 mm ISO connector.
-
Pilot Balloon: Color-coded; provides visual indication of cuff inflation.
-
Packaging: Sterile, single-use; individually packaged.
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: Class II medical device regulated by FDA.
-
Cuff Safety: High-volume, low-pressure design minimizes tracheal injury risk.
-
Biocompatibility: Materials safe for airway contact.
-
Latex-Free: Manufactured without natural rubber latex.
-
MRI Compatibility: Special MRI-compatible versions available for imaging procedures.
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store in a clean, dry location at room temperature; protect from heat.
-
Sterility Maintenance: Do not use it if the package is opened, damaged, or wet.
-
Expiration: Check expiration date before use; do not use after expiration.
-
Single-Use Only: Intended for single patient use only; do not resterilize or reuse.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Kink-resistant airway management for prone positioning, neurosurgery, long-term ventilation, and difficult airways.
-
Clinical Role: Essential equipment in neurosurgery, spinal surgery, intensive care, and difficult airway management.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Tube Size Selection: Select appropriate size based on patient anatomy and clinical requirements.
-
Cuff Pressure Monitoring: Inflate cuff to minimal occluding volume; maintain cuff pressure between 20-30 cm H₂O.
-
Confirmation: Verify placement by auscultation, end-tidal CO₂, and radiographic confirmation.
-
Reinforcement Integrity: Inspect tube for kinks or damage before use; do not use if reinforcement is compromised.
-
Secure Positioning: Secure tube to prevent accidental extubation.
-
MRI Compatibility: Verify MRI compatibility before use in imaging suite.
2. FIRST AID MEASURES
-
Tube Displacement: If tube is displaced, manually ventilate patient; remove tube; reintubate as needed.
-
Cuff Rupture: If cuff ruptures, consider tube replacement if ventilation is compromised.
-
Obstruction: If tube is obstructed, attempt to suction; consider tube replacement if patency cannot be restored.
3. FIRE FIGHTING MEASURES
-
Flammability: Plastic components are combustible; an oxygen-enriched environment increases fire risk.
-
Extinguishing Media: For fire in the airway, disconnect oxygen source; remove tube if safe; use appropriate extinguisher.
Related products
Air & Oxygen Blender
$1.00
An Air & Oxygen Blender is a Class II medical device that precisely mixes compressed medical air and oxygen to deliver controlled fractions of inspired oxygen (FiO2 21-100%) to patients requiring respiratory support. Essential in neonatal, pediatric, and adult critical care, these devices ensure accurate oxygen delivery via ventilators, CPAP systems, oxygen hoods, incubators, and transport systems. Operating at 40-60 psi inlet pressure, they maintain set FiO2 within ±2-5% accuracy across varying flow demands (0-120 L/min). Gas-specific DISS or NIST fittings prevent dangerous cross-connection between oxygen and air supplies. Available in wall-mounted, rail-mounted, portable, and ventilator-integrated configurations. Primary clinical applications include neonatal intensive care (oxygen hoods, incubators, nasal CPAP), pediatric and adult mechanical ventilation, non-invasive ventilation, and critical care transport. Critical safety requirements include verification of correct gas connections, regular calibration, leak testing, and immediate response to gas supply failure alarms. Indispensable for preventing both hypoxemia and oxygen toxicity (particularly retinopathy of prematurity in neonates) in patients requiring precise oxygen therapy.
Humidifier Bottle
$1.00
A Humidifier Bottle is a water reservoir device that adds moisture to dry medical oxygen before delivery to the patient. It attaches between the oxygen flow meter and the patient's oxygen delivery device, bubbling oxygen through sterile water to achieve relative humidity levels of 80-95%. Essential for patients receiving oxygen at flow rates above 4-6 liters per minute, it prevents drying of the nasal mucosa, pharynx, and lower airways, reducing discomfort and maintaining normal mucociliary clearance. Available in disposable sterile and reusable configurations, the bottle requires daily water changes with sterile water and proper positioning below the patient to prevent water carryover. Pressure relief valves protect against over-pressurization.
Infant T-Piece Resuscitator
$1.00
An Infant T-piece Resuscitator is a Class II medical device designed for neonatal resuscitation and controlled positive pressure ventilation, delivering precise, consistent peak inspiratory pressures (PIP) and positive end-expiratory pressure (PEEP) as recommended by Neonatal Resuscitation Program (NRP) guidelines. The T-piece assembly connects to compressed air/oxygen source (5-15 L/min) with adjustable PIP (10-40 cmH₂O) and PEEP (0-10 cmH₂O) controls, built-in pressure manometer, and pressure relief valve (30-40 cmH₂O). Operator occludes port to deliver breaths (typically 40-60/min), with consistent pressures maintained regardless of technique. Essential advantages over bag-valve-mask devices include operator-independent pressure delivery, ability to provide PEEP (critical for preterm lung protection), reduced risk of barotrauma, and hands-free PEEP allowing two-handed mask seal. Primary clinical applications include delivery room resuscitation, stabilization of extremely preterm infants (<1,000 g), CPAP/PEEP delivery, meconium aspiration management, and neonatal transport ventilation. Critical safety considerations include verifying gas supply (5-15 L/min), monitoring manometer pressures, ensuring proper mask seal, observing chest rise, and titrating FiO2 to SpO2 targets. Indispensable resuscitation equipment in every delivery room, NICU, and neonatal transport setting worldwide.
Inhaler Spacer with Child Mask
$1.00
An Inhaler Spacer with Child Mask is a valved holding chamber designed to optimize aerosol medication delivery from metered-dose inhalers to infants and young children. The spacer captures the medication spray, allowing the child to inhale over multiple breaths, while the soft mask creates a seal over the nose and mouth. This improves pulmonary drug deposition, reduces oropharyngeal side effects, and eliminates the need for complex breath coordination. Essential for pediatric asthma management, the spacer enables effective inhaler use in children as young as infancy, supporting home management of reactive airway disease.
Macintosh Fiber Optic Laryngoscope
$1.00
A Macintosh Fiber Optic Laryngoscope is a rigid laryngoscope with curved Macintosh blade (sizes 0-4, 70-160 mm) incorporating an integrated fiber optic light bundle that transmits bright, focused illumination (2,000-10,000+ Lux) from a handle-mounted LED or xenon bulb to the blade tip for enhanced visualization during tracheal intubation. The curved blade design allows indirect epiglottis elevation by placing the tip in the vallecula, requiring less force and neck extension than straight blades. Features stainless steel reusable blades, ergonomic handles with knurled grip, ISO standard hook-on fittings, and steam autoclave compatibility. Primary clinical applications include routine and emergency tracheal intubation during general anesthesia, difficult airway management with improved illumination, cervical spine precautions (minimal neck movement), teaching and training (enhanced visualization for instructors), rapid sequence intubation, neonatal and pediatric intubation (sizes 0-2), and oral/maxillofacial surgery. Class II medical device requiring FDA clearance. Critical safety considerations include pre-use light check (dark spots indicate broken fibers), appropriate blade size selection, proper lifting technique (not levering on teeth), battery verification, fiber optic care (avoid sharp bending), and backup device availability.
Non-Rebreathing Oxygen Mask
$1.00
An Non-Rebreathing Oxygen Mask is a high-concentration oxygen delivery device designed for emergency use in critically hypoxic patients. It features a face mask with an attached reservoir bag and a system of one-way valves to prevent the rebreathing of exhaled carbon dioxide, allowing for the delivery of up to 95% FiO2. Its safe operation depends on a minimum oxygen flow of 10-15 L/min to keep the reservoir bag inflated. It is contraindicated where uncontrolled high-flow oxygen may be harmful (e.g., in some COPD patients) and carries a severe fire risk. It is a vital, immediate-intervention tool found in all emergency response settings.
Oxygen set (gauge, humidifier, flow meter)
$1.00
An Oxygen Set consists of a pressure gauge, flow meter, and humidifier that together regulate, monitor, and humidify oxygen delivered to a patient. The pressure gauge indicates cylinder contents, the flow meter controls delivery rate in liters per minute, and the humidifier adds moisture to dry medical oxygen to prevent airway irritation. Used with wall outlets or portable cylinders, this equipment is essential for all oxygen therapy delivery. Safe operation requires strict adherence to no-oil, no-smoking policies, regular monitoring of water levels and cylinder pressure, and proper orientation of the flow meter for accurate delivery.
Yankauer Suction
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties