Oxygen set (gauge, humidifier, flow meter)

$1.00

WhatsApp Order
An Oxygen Set consists of a pressure gauge, flow meter, and humidifier that together regulate, monitor, and humidify oxygen delivered to a patient. The pressure gauge indicates cylinder contents, the flow meter controls delivery rate in liters per minute, and the humidifier adds moisture to dry medical oxygen to prevent airway irritation. Used with wall outlets or portable cylinders, this equipment is essential for all oxygen therapy delivery. Safe operation requires strict adherence to no-oil, no-smoking policies, regular monitoring of water levels and cylinder pressure, and proper orientation of the flow meter for accurate delivery.
Description

Oxygen Set (Gauge, Humidifier, Flow Meter)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Pressure Regulation and Flow Control for Oxygen Delivery
  • Primary Use: Reduces the high pressure of oxygen from a cylinder or wall source to a safe, usable working pressure and provides precise control over the flow rate delivered to the patient via nasal cannula, oxygen mask, or other oxygen delivery device. The gauge displays cylinder pressure, while the flow meter controls the rate of oxygen delivery in liters per minute.
  • How it helps: For the respiratory therapist, nurse, and clinician managing oxygen therapy, the oxygen set transforms a dangerously pressurized oxygen source into a controlled, therapeutic tool—taking thousands of pounds of pressure and delivering it as a gentle, metered flow that can be adjusted precisely to the patient’s needs. For the patient receiving oxygen, the flow meter ensures they receive exactly the flow their doctor prescribed, protecting them from both undertreatment and the dangers of excessive, unregulated oxygen delivery.
2. Humidification of Delivered Oxygen
  • Primary Use: The humidifier adds moisture to dry medical oxygen before it reaches the patient. Dry oxygen can irritate the nasal mucosa, pharynx, and lower airways, causing discomfort, drying of secretions, and increased risk of mucosal bleeding. The humidifier bubbles oxygen through sterile water, delivering oxygen with enhanced humidity to the patient.
  • How it helps: For the nurse and respiratory therapist managing patients on oxygen therapy, the humidifier prevents the uncomfortable drying of airways that occurs with dry medical oxygen—reducing nasal crusting, preventing throat irritation, and helping to keep pulmonary secretions thin and mobilizable. For the patient breathing oxygen, humidification means the difference between comfortable therapy and the misery of dry, irritated airways that can lead to nosebleeds and thickened secretions.
3. Monitoring of Oxygen Cylinder Contents
  • Primary Use: The pressure gauge provides continuous visual indication of remaining oxygen in the cylinder, allowing clinicians to monitor oxygen supply and ensure uninterrupted therapy. This is critical during patient transport and in settings where cylinder oxygen is the primary source.
  • How it helps: For the transport team and nursing staff, the pressure gauge provides the information needed to ensure oxygen therapy continues without interruption—alerting them when a cylinder is running low and needs replacement before the patient experiences oxygen desaturation. For the patient, reliable monitoring means their oxygen supply never unexpectedly runs out, providing continuity of therapy and peace of mind.
4. Support for Multiple Oxygen Delivery Devices
  • Primary Use: The flow meter provides adjustable flow rates suitable for a wide range of oxygen delivery devices, including nasal cannula (low flow), simple face masks, non-rebreather masks, and Venturi masks. Flow rates can be precisely set to match the prescribed oxygen concentration and delivery method.
  • How it helps: For the clinician selecting the appropriate oxygen delivery device, the flow meter’s wide range of adjustability allows the same oxygen set to support patients with varying oxygen requirements—from the patient needing a low flow of supplemental oxygen to the acutely hypoxic patient requiring high-flow oxygen via non-rebreather mask. For the patient, this versatility means their oxygen therapy can be adjusted as their condition changes without changing equipment.
5. Emergency and Backup Oxygen Administration
  • Primary Use: Serves as a critical component of emergency oxygen kits, crash carts, and hospital backup systems where piped wall oxygen is unavailable or fails. The portable cylinder with oxygen set provides immediate oxygen availability anywhere in the facility.
  • How it helps: For the code team and emergency responders, a cylinder with an oxygen set means oxygen is immediately available anywhere—in the parking lot, the radiology suite, or during a power outage when wall oxygen fails. For the patient in respiratory distress, this portable oxygen set ensures they receive controlled, therapeutic oxygen even when the usual systems are unavailable.

SECONDARY & SUPPORTIVE USES

1. Oxygen-Powered Nebulizer Drive: The flow meter can be set to provide the higher flow rates needed to power a jet nebulizer for aerosolized medication delivery, allowing bronchodilators and other inhaled medications to be administered concurrently with oxygen therapy.
2. Calibration and Testing: Used in clinical engineering and respiratory therapy departments to test and calibrate other oxygen delivery devices, ensuring accuracy and reliability across the facility.
3. Home Oxygen Therapy: Portable oxygen sets are used by patients on long-term oxygen therapy who use cylinders as their primary or backup oxygen source at home, allowing them to control their prescribed flow independently.
4. Inter-Facility Patient Transport: Oxygen sets are essential for transporting patients between facilities, providing continuous oxygen support during ground or air medical transport.
5. Veterinary Applications: Used in veterinary medicine for administering oxygen to animals undergoing surgery, in critical care, or during transport.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A system of components consisting of a pressure gauge, flow meter, and humidifier used to regulate, monitor, and humidity oxygen delivered to a patient.
  • Designation: Oxygen Set, Oxygen Regulator Set, Oxygen Flow Meter with Humidifier, Oxygen Delivery System.
  • Key Components:
    • Pressure Gauge: Measures the pressure of oxygen in the cylinder; indicates remaining oxygen supply.
    • Flow Meter: Controls the rate of oxygen flow in liters per minute; may be calibrated for vertical or horizontal orientation.
    • Humidifier: A water-containing bottle that bubbles oxygen through sterile water to add moisture; includes a water reservoir, inlet and outlet ports, and a pressure relief valve.
    • Pressure Regulator: Reduces high cylinder pressure to safe working pressure for the flow meter and patient.
    • Connectors: Standardized fittings for attachment to oxygen cylinders (CGA 870, CGA 540) and wall outlets.
    • Oxygen Tubing: Flexible tubing to connect the humidifier outlet to the patient's oxygen delivery device.

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Pressure Gauge Range: Typical scale from 0 to 2000-3000 psi for high-pressure cylinders.
  • Flow Meter Range: Adjustable flow rates typically from 0 to 15 L/min; some models support up to 25 L/min for high-flow applications.
  • Flow Meter Accuracy: Calibrated to deliver accurate flow regardless of back pressure or cylinder pressure fluctuations.
  • Humidifier Output: Delivers oxygen with relative humidity typically between 80% and 95% at room temperature.
  • Pressure Relief Valve: Prevents over-pressurization of the humidifier; activates at predetermined pressure to vent excess gas.
  • Material: Anodized aluminum, brass, or stainless steel for pressure components; polycarbonate or plastic for humidifier bottles.

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Orientation: Available in vertical (post-mounted) and horizontal (wall-mounted) configurations.
  • Humidifier Capacity: Typical water capacity 250-500 mL; graduated markings for monitoring water level.
  • Portability: Compact design for cylinder-mounted use during patient transport.
  • Mounting: Wall outlets use quick-connect or DISS (Diameter Index Safety System) connectors; cylinder-mounted sets thread directly onto the cylinder valve.
  • Connector Safety: Pin-index safety system for cylinder connections ensures oxygen-specific fittings are used.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: Class I and Class II medical devices; flow meters and regulators are regulated by FDA.
  • Pressure Safety: Pressure relief devices prevent over-pressurization; cylinder connection safety systems prevent accidental use with incorrect gas.
  • Flammability Warning: Oxygen supports combustion. All components must be kept away from oil, grease, and flammable materials. Prohibit smoking and open flames in the area.
  • Material Compatibility: Components are oxygen-clean and free of hydrocarbons to prevent combustion.

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store in a clean, dry area; protect from dust and damage. Humidifier bottles are stored sterile until use.
  • Cleaning: External surfaces wiped with mild detergent; do not use oil-based cleaners. Humidifier bottles are single-use disposable or reusable with sterilization between patients.
  • Maintenance: Regular inspection of gauges for accuracy; pressure relief valve testing; flow meter calibration verification; O-ring and gasket replacement as needed.
  • Water Management: Humidifier water changed daily or per facility protocol; sterile water used to prevent microbial contamination.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Regulated oxygen delivery with humidification for patients requiring supplemental oxygen in hospitals, clinics, home care, and transport settings.
  • Clinical Role: Essential equipment for every oxygen source, providing the interface between the gas supply and the patient.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • No Oil or Grease: Never use oil or grease on oxygen equipment; hydrocarbons can cause spontaneous combustion in an oxygen-enriched environment.
  • Cylinder Handling: Secure cylinders to prevent tipping; use appropriate carts and holders.
  • Flow Meter Orientation: Use flow meter in correct orientation (vertical or horizontal) as designed; incorrect orientation affects accuracy.
  • Humidifier Water Level: Maintain water level above minimum to ensure adequate humidification; do not overfill.
  • Humidifier Replacement: Replace or refill humidifier daily; sterile water only; never leave stagnant water in humidifier.
  • Tubing Integrity: Check oxygen tubing for kinks, cracks, or disconnections; ensure secure connections.
  • Pressure Gauge Monitoring: Monitor cylinder pressure regularly; replace cylinder before pressure falls below safe operating level.
  • Fire Safety: Post "Oxygen in Use" signs; prohibit smoking and open flames; ensure oxygen shut-off valve accessible in emergency.

2. FIRST AID MEASURES

  • Oxygen Flow Interruption: If flow stops, check cylinder contents, flow meter setting, tubing connections, and humidifier water level; replace cylinder if depleted.
  • Humidifier Leak: If humidifier leaks, remove from service immediately; replace with sterile unit.
  • Pressure Gauge Failure: If gauge is damaged or non-functional, remove cylinder from service; tag for repair.
  • Skin or Eye Contact with Oxygen: No specific first aid required; oxygen is not hazardous to skin or eyes.

3. FIRE FIGHTING MEASURES

  • Flammability: Oxygen supports and accelerates combustion; fire risk is severe in oxygen-enriched atmosphere.
  • Extinguishing Media: For oxygen-fed fire, shut off the oxygen source first; then use appropriate extinguisher for surrounding materials.
  • Prevention: Strict adherence to no-smoking and no-oil policies; ensure oxygen valves accessible for emergency shut-off.