Conductivity Probe (DPH1-S)
WhatsApp Order
The Conductivity Probe (DPH1-S) is a replacement combined pH/ORP electrode specifically designed for DLAB DPH1 pen-type pH/ORP meter and DPH1+ Bluetooth pen meter . The probe features a glass pH sensing bulb for precise pH measurement, an integrated thermistor for automatic temperature compensation (ATC), and a polycarbonate body that is resistant to many aqueous solutions but should avoid organic solvents such as carbon tetrachloride, trichloroethylene, tetrahydrofuran, toluene, xylene, and methyl ethyl ketone .
The Conductivity Probe (DPH1-S) enables the DPH1 and DPH1+ meters to measure pH (-2.00 to 16.00 pH, accuracy ±0.01 pH) , ORP (-1000.0 to +1000.0 mV, accuracy ±0.1 percent of full scale ±1 digit), and temperature (0 to 60 degrees Celsius, accuracy ±0.2 degrees Celsius) . When used with the compatible meters, the probe supports 1 to 3 point automatic pH calibration with buffer recognition and is compatible with CH, USA, and NIST standard buffer solutions for flexible calibration options . The probe shares the meter’s IP67 dustproof and waterproof rating for reliable operation in harsh field environments .
The probe features a removable protective cover that prevents damage to the glass pH sensing bulb and facilitates easy cleaning . The probe is pre-installed in new DPH1 and DPH1+ meter kits and is available as a replacement part to extend instrument service life—electrode replacement rather than complete meter replacement . Replacement is straightforward for trained laboratory personnel, and the probe is a consumable item not covered under the instrument warranty .
For the clinical laboratory scientist, dialysis technician, and water quality specialist, the Conductivity Probe (DPH1-S) ensures continued, accurate pH and ORP monitoring of purified water systems, dialysis fluids, biological fluids, and pharmaceutical process water—critical parameters for ensuring patient safety during renal replacement therapy, diagnosing acid-base disorders, and supporting drug manufacturing.
For the patient, reliable replacement parts ensure continuous water quality monitoring in dialysis and pharmaceutical applications, preventing gaps in quality surveillance that could compromise patient safety. Accurate pH measurement of biological fluids supports early detection of metabolic disturbances, acid-base imbalances, and renal dysfunction, enabling timely clinical intervention.
Categories: LABORATORY EQUIPMENT AND SUPPLIES, Lab Consumables
Tags: Combination Electrode, Conductivity Probe (DPH1-S), Conductivity Probe (DPH1-S) Replacement Electrode, DLAB DPH1-S, ORP Measuring Electrode, pH/ORP Pen Meter Probe, pH/Temperature Probe, Replacement pH Probe, Water Quality Testing Accessory
Description
Conductivity Probe (DPH1-S)
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Replacement pH Electrode for Pen-Based Water Quality Analyzers
-
Primary Use: Provides a replacement combined pH electrode specifically designed for DLAB DPH1 and DPH1+ pen meters, integrating pH sensing, reference, and automatic temperature compensation (ATC) into a single replaceable probe . The polycarbonate electrode body is designed for general aqueous solutions but should avoid organic solvents such as carbon tetrachloride, trichloroethylene, tetrahydrofuran, toluene, xylene, and methyl ethyl ketone.
-
How it helps: For the clinical laboratory scientist and water quality specialist, the DPH1-S allows continued use of the DPH1 and DPH1+ pen meters by replacing only the sensing electrode rather than the entire instrument—reducing equipment costs and minimizing downtime for critical water quality monitoring. For the patient, reliable replacement parts ensure continuous monitoring of dialysis water and purified water systems, preventing gaps in water quality surveillance that could compromise patient safety. The 1-year manufacturer warranty covers the instrument but the electrode is considered a consumable, with an expected lifespan dependent on usage and care .
2. pH Measurement for Dialysis Water and Biological Fluid Testing
-
Primary Use: Measures pH across the range of -2.00 to 16.00 pH with accuracy of ±0.01 pH ±1 digit and resolution of 0.1 or 0.01, supporting pH assessment of purified water, dialysis fluids, and biological specimens when used with compatible pen meters .
-
How it helps: For dialysis technicians and clinical laboratory scientists, the DPH1-S sensor enables rapid, on-site pH verification of water used in renal replacement therapy and biological fluid analysis. The 1 to 3-point automatic calibration with buffer recognition (compatible with CH, USA, and NIST standard buffer solutions) ensures measurement reliability across different sample types . For the patient, accurate pH measurement of dialysis water helps prevent adverse events related to improper water composition, while pH testing of biological fluids supports diagnosis of metabolic acidosis, alkalosis, diabetic ketoacidosis, and renal tubular disorders.
3. Automatic Temperature Compensation for Accurate Readings
-
Primary Use: Integrated temperature sensor provides automatic temperature compensation (ATC) across 0 to 60 degrees Celsius, ensuring pH measurements are automatically corrected to standard reference temperatures.
-
How it helps: For the clinical laboratory scientist and water quality specialist, the built-in temperature sensor eliminates the need for a separate temperature probe, while automatic temperature compensation ensures that pH readings are automatically corrected to standard reference temperatures, eliminating calculation errors and improving measurement accuracy. For the patient, accurate temperature-compensated measurements ensure that water quality data used for clinical decision-making is reliable and consistent across varying sample temperatures.
4. ORP Measurement Capability with Same Electrode
-
Primary Use: The DPH1-S electrode also supports oxidation-reduction potential (ORP) measurement from -1000.0 to +1000.0 mV with accuracy of ±0.1 percent of full scale ±1 digit when used with the DPH1 or DPH1+ pen meters .
-
How it helps: For infection control officers and dialysis technicians, ORP measurement using the DPH1-S enables rapid, on-site verification of disinfection efficacy in purified water loops, dialysis water systems, and hospital plumbing—directly confirming that oxidizing agents such as chlorine are present at effective concentrations for microbial control. The 0.1 mV selectable resolution allows for precise measurement across various water quality applications . For the patient, accurate ORP monitoring ensures that water used in renal replacement therapy meets critical safety standards for dialysis treatment.
5. Compatibility with DPH1 and DPH1+ Meter Systems
-
Primary Use: Designed as the dedicated replacement electrode for DLAB DPH1 pen-type pH/ORP meter and DPH1+ Bluetooth pen meter, ensuring proper fit and electrical compatibility for pH, ORP, and temperature measurement .
-
How it helps: For the laboratory manager and equipment coordinator, using the manufacturer-specified replacement probe ensures optimal instrument performance, calibration accuracy, and measurement reliability. The DPH1-S is pre-installed in new DPH1 and DPH1+ meter kits and is available separately for replacement needs. The electrode features a removable protective cover that prevents damage to the glass bulb and facilitates cleaning. For the patient, properly compatible replacement parts ensure that water quality monitoring equipment continues to function within manufacturer specifications, maintaining the integrity of quality assurance programs.
SECONDARY & SUPPORTIVE USES
1. Purified Water System Verification: Used with DPH1 and DPH1+ meters to verify pH of purified water, water-for-injection (WFI), and distilled water in hospital and laboratory water treatment systems.
2. Pharmaceutical Process Water Testing: Supports pH measurement for validation and routine monitoring of pharmaceutical water systems, with probe replacement ensuring continued compliance.
3. Dialysis Water Quality Verification: Used with DPH1 and DPH1+ meters to test pH of dialysis water and dialysate solutions, with regular probe replacement maintaining measurement accuracy.
4. Cooling Tower and Boiler Water Testing: Measures pH in cooling towers, boiler feed water, and steam generation systems to assess corrosion potential and treatment efficacy.
5. Environmental and Wastewater Monitoring: Enables pH measurement of wastewater discharge, surface water, and groundwater in hospital environmental monitoring programs.
6. Reagent and Buffer Quality Control: Verifies pH of laboratory reagents, buffers, and preparation solutions to ensure consistent experimental conditions.
7. Aquaculture and Zebrafish Facility Management: Used to check pH levels in aquatic animal housing facilities within research institutions.
8. Hydroponic and Agricultural Nutrient Management: Monitors pH of nutrient solutions in controlled environment agriculture and research plant growth facilities.
9. Electrode Replacement for Extended Instrument Life: Serves as the replacement component to extend the service life of DPH1 and DPH1+ meters when the original probe reaches end of life .
10. ORP Measurement for Disinfection Monitoring: Enables oxidation-reduction potential measurement for assessing disinfection efficacy in water treatment systems .
11. Removable Protective Cover: Features a removable electrode bulb protective cover that prevents damage to the glass pH sensing bulb and facilitates easy cleaning .
12. Calibration Support: Compatible with CH, USA, and NIST standard buffer solutions for flexible calibration options corresponding to regional requirements .
13. IP67-Compatible Probe: The probe shares the meter’s IP67 dustproof and waterproof rating, suitable for use in harsh field environments .
14. Combined Electrode Design: Combination electrode design allows replacement as needed to meet different testing requirements.
15. Storage Solution Requirement: Requires storage in 3 mol KCl pH/ORP electrode soaking solution to prevent the pH sensing bulb from drying out and to maintain optimal performance .
16. Polycarbonate Electrode Body: The polycarbonate body is resistant to many aqueous solutions but should avoid organic solvents such as carbon tetrachloride, trichloroethylene, tetrahydrofuran, toluene, xylene, and methyl ethyl ketone .
17. Multi-Parameter Compatibility: Compatible with both pH and ORP measurement on the DPH1 series meters, allowing a single electrode to support multiple water quality parameters.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A replacement combined pH/ORP electrode for DLAB DPH1 and DPH1+ pen meters, integrating pH sensing (glass bulb), reference, and temperature sensing (thermistor) into a single replaceable probe for water quality analysis .
-
Designation: DPH1-S Conductivity Probe, DPH1-S Replacement Electrode, pH/ORP Pen Meter Probe, DLAB DPH1-S, Combination Electrode.
-
Key Components:
-
pH Sensing Element: Glass bulb for pH measurement .
-
Temperature Sensor: Integrated thermistor for automatic temperature compensation .
-
Probe Body: Polycarbonate combined probe design .
-
Connection: Compatible with DPH1 and DPH1+ meter housing .
-
Protective Cover: Removable electrode bulb protective cover .
-
Materials: Glass pH bulb, polycarbonate body, thermistor sensor .
-
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Compatible Meters: DPH1 Pen-Type pH/ORP Meter, DPH1+ Bluetooth Pen Meter .
-
pH Measurement Range (with compatible meter): -2.00 to 16.00 pH .
-
pH Resolution (with compatible meter): 0.1 or 0.01 (selectable) .
-
pH Accuracy (with compatible meter): ±0.01 pH ±1 digit .
-
pH Calibration (with compatible meter): 1 to 3 points automatic calibration; automatic buffer recognition; supports CH, USA, and NIST standard buffer solutions .
-
pH Automatic Temperature Compensation Range: 0 to 60 degrees Celsius (32 to 140 degrees Fahrenheit) .
-
ORP Measurement Range (with compatible meter): -1000.0 to +1000.0 millivolts .
-
ORP Resolution (with compatible meter): 0.1 or 1 (selectable) .
-
ORP Accuracy (with compatible meter): ±0.1 percent of full scale ±1 digit .
-
Temperature Measurement Range (with compatible meter): 0.0 to 60.0 degrees Celsius (32.0 to 140.0 degrees Fahrenheit) .
-
Temperature Accuracy (with compatible meter): ±0.2 degrees Celsius .
-
Probe Type: Combined electrode design; replaceable .
-
Sensing Material: Glass (pH bulb), Thermistor (temperature) .
-
Body Material: Polycarbonate .
-
Protection Class (with meter): IP67 (dustproof and waterproof) .
-
Calibration Compatibility: Supports CH, USA, and NIST standard buffer solutions .
-
Storage Requirement: 3 mol KCl pH/ORP electrode soaking solution recommended for pH bulb hydration .
-
Replacement Purpose: Extends instrument service life by allowing electrode replacement rather than complete meter replacement .
-
Chemical Compatibility: The polycarbonate electrode body should avoid organic solvents such as carbon tetrachloride, trichloroethylene, tetrahydrofuran, toluene, xylene, and methyl ethyl ketone .
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: Pen-style combined probe designed to fit DPH1 and DPH1+ meter housing; sealed, maintenance-free design .
-
Sensing Technology: Glass pH bulb for hydrogen ion activity; thermistor for automatic temperature compensation; reference system for stable potential .
-
Removable Protective Cover: Features a removable electrode bulb protective cover that prevents damage to the glass pH sensing bulb and facilitates easy cleaning before and after use .
-
Installation: User-replaceable; installs directly into DPH1 and DPH1+ meter body.
-
Compatibility: Specifically designed for DLAB DPH1 and DPH1+ pen meters; not compatible with other meters .
-
Maintenance: Requires no electrolyte refilling; clean with distilled water after each use; keep pH bulb moist using 3 mol KCl storage solution; never store dry .
-
Storage: Store electrode with protective cap in place; keep pH sensing bulb moist using 3 mol KCl storage solution to prevent drying; never store dry .
-
Hydration: If the pH sensing bulb has dried out, soak in 3 mol KCl storage solution for 24 to 48 hours before use; recalibrate before use.
-
Visual Confirmation: Removable protective cover allows visual inspection of glass bulb condition and facilitates cleaning.
-
Durability: Designed for harsh field environments with IP67 rating when installed on meter .
-
Calibration: Performed through the DPH1 and DPH1+ meters using standard solutions; probe does not require separate calibration.
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: Accessory and replacement part for in vitro diagnostic preparatory equipment (DPH1 and DPH1+ meters).
-
Safety Certifications: Manufactured under ISO 9001:2015 quality management system; CE compliant .
-
Protection Class (with meter): IP67 (dustproof and waterproof against temporary immersion up to 1 meter for 30 minutes) .
-
Material Safety: Glass pH bulb (fragile, handle with care); polycarbonate plastic body (avoid organic solvents); RoHS compliant materials.
-
Electrical Safety: Low-voltage passive component; safe for use with DPH1 and DPH1+ meters (four AAA batteries, 1.5 volts each).
-
Replacement Indicator: Replace probe when readings become unstable, calibration fails repeatedly, glass bulb is cracked, or physical damage is visible.
-
Consumable Status: The electrode is considered a consumable item and is not covered under the instrument warranty .
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store probe with protective cap in place; keep pH sensing bulb moist using 3 mol KCl pH/ORP electrode soaking solution; never store dry; avoid extreme temperatures and direct sunlight .
-
Cleaning: Rinse with distilled water after each use; for stubborn residues, use mild detergent and soft brush, taking care not to damage the glass pH bulb; do not scrub glass bulb with abrasive materials. The removable protective cover facilitates cleaning of the electrode bulb .
-
Inspection: Inspect the glass pH bulb for cracks or damage before each use; inspect the probe body for any visible damage; verify that the glass bulb is free of cracks or scratches.
-
Installation: Insert probe into DPH1 or DPH1+ meter body securely; ensure proper electrical contact; follow meter instructions for probe replacement .
-
Calibration: After probe replacement, calibrate the DPH1 or DPH1+ meter using appropriate calibration standards before use—pH buffers (pH 4.00 and pH 6.86 or 7.00) as appropriate for the expected sample pH range .
-
Hydration: If the pH sensing bulb has dried out, soak in 3 mol KCl storage solution for 24 to 48 hours before use; recalibrate before use .
-
Handling: Handle with care to prevent damage to the glass pH bulb; do not touch glass bulb with fingers, as oils can affect measurement accuracy; do not bend or apply excessive force to the probe.
-
Chemical Compatibility: Avoid using the electrode in organic solvents such as carbon tetrachloride, trichloroethylene, tetrahydrofuran, toluene, xylene, or methyl ethyl ketone, which may damage the polycarbonate plastic body .
-
Replacement Frequency: Replace probe when meter readings become unstable, calibration fails repeatedly, glass bulb is cracked, or physical damage is evident; no fixed replacement interval—depends on usage and sample types.
-
Disposal: Dispose of used probe according to local electronic waste regulations; the probe contains glass and plastic components.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Replacement pH and ORP electrode for DPH1 and DPH1+ pen meters, used for measuring pH and ORP in purified water, dialysis fluids, biological fluids (serum, plasma, urine), pharmaceutical process water, and environmental samples in clinical diagnostic, pharmaceutical, and research settings.
-
Clinical Role: Essential replacement component for water quality testing instruments used in dialysis units, hospital engineering departments, pharmaceutical quality control laboratories, clinical chemistry laboratories, and environmental monitoring programs requiring portable pH and ORP measurement.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Handling: Handle probe with care to avoid damage to the glass pH bulb; glass bulb is fragile and can break if bumped or dropped. Do not touch glass bulb with fingers, as oils can affect measurement accuracy.
-
Cleaning: Do not use abrasive materials or harsh chemicals on the glass pH bulb; rinse thoroughly after cleaning to remove all residue. The removable protective cover facilitates safe cleaning .
-
Storage: Always store probe with protective cap in place; keep the pH sensing bulb moist using 3 mol KCl storage solution to prevent drying; never store dry .
-
Hydration: If the pH sensing bulb has dried out, soak in 3 mol KCl storage solution for 24 to 48 hours before use; recalibrate before use.
-
Compatibility: Use only with DLAB DPH1 or DPH1+ meters; using with incompatible meters may damage the probe or produce inaccurate readings .
-
Chemical Compatibility: Avoid using the electrode in organic solvents such as carbon tetrachloride, trichloroethylene, tetrahydrofuran, toluene, xylene, or methyl ethyl ketone, which may damage the polycarbonate plastic body .
-
Calibration Requirement: Always recalibrate the meter after installing a new DPH1-S probe to ensure measurement accuracy for pH and ORP.
-
Avoid Freezing: Do not allow the probe to freeze; freezing temperatures may damage the glass pH bulb .
-
Avoid Dehydration: Do not allow the pH sensing bulb to dry out; prolonged dry storage will damage the glass membrane and require extended rehydration .
-
Training: Only trained laboratory personnel should replace and handle the DPH1-S probe for water quality testing applications.
2. FIRST AID MEASURES
-
Glass Breakage: If the glass pH bulb breaks, carefully collect any glass fragments using forceps; dispose in sharps container; inspect sample for glass contamination before further use; avoid skin contact with broken glass edges.
-
Sample Splash: If sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
-
Storage Solution Exposure: If electrode storage solution (3 mol KCl) splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
-
Electrical Malfunction: If the meter with installed probe shows signs of electrical malfunction, remove batteries immediately; do not attempt to operate; contact service personnel.
3. FIRE FIGHTING MEASURES
-
Flammability: The plastic housing (polycarbonate) is combustible; may melt or burn if exposed to flame or high heat.
-
Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for fires involving plastic components.
-
Fire Response: Remove from heat source if safe to do so; do not use water on electrical fire.
Related products
Binocular Microscope
$1.00
A Binocular Microscope is a high-precision, compound optical instrument fundamental to clinical diagnostics. Featuring dual eyepieces for comfortable viewing and a suite of parfocal objective lenses (4x, 10x, 40x, 100x oil), it provides magnifications from 40x to 1000x. Its integrated LED illumination, mechanical stage, and Abbe condenser enable the detailed examination of stained blood films, tissue sections, microbiological specimens, and cytological preparations. As the primary tool for pathologists and laboratory scientists, it is indispensable for definitive diagnoses in hematology, histopathology, microbiology, and urinalysis, demanding skilled operation and meticulous maintenance for optimal performance.
Blood Grouping kit
$1.00
A Blood Grouping Kit is a Class II medical device (FDA-cleared/CE-marked) containing monoclonal antibodies (Anti-A, Anti-B, Anti-D) and control reagents for determining ABO blood group and Rh factor by agglutination method. The kit includes color-coded reagent vials, reaction cards or slides, mixing sticks, lancets, and capillary pipettes. Test time 2-5 minutes (slide method) or 15-30 minutes (tube method). Interpretation based on agglutination pattern: Anti-A positive = group A; Anti-B positive = group B; both positive = group AB; both negative = group O; Anti-D positive = Rh positive; Anti-D negative = Rh negative. Primary clinical applications include pre-transfusion compatibility testing, prenatal and neonatal testing (Rh incompatibility prevention), preoperative blood typing, blood donor screening, and emergency blood typing. Critical safety precautions include refrigerated storage (2-8°C), proper disposal of lancets in sharps containers, universal precautions for blood samples, and confirmation with reverse typing when possible. Essential kit for transfusion medicine, obstetrics, surgery, and emergency care.
Coagulation Analyzer
$1.00
A Coagulation Analyzer is a compact, automated instrument designed for performing essential tests that evaluate the blood's clotting ability. It accurately measures key parameters such as Prothrombin Time (PT/INR), Activated Partial Thromboplastin Time (aPTT), Thrombin Time, and Fibrinogen, which are critical for monitoring anticoagulant therapy (warfarin, heparin), diagnosing bleeding disorders, and assessing surgical risk. With its photometric detection and user-friendly operation, it delivers reliable results for small to medium-volume laboratories, clinics, and hospital wards. Its role in ensuring safe and effective patient management in thrombosis and hemostasis makes it a vital tool in clinical diagnostics.
ESR Tubes Glass
$1.00
ESR Tubes Glass are specialized glass tubes (300 mm length, 2.55 mm bore diameter, graduated 0-200 mm in 1 mm intervals) meeting ICSH and CLSI Westergren specifications for measuring erythrocyte sedimentation rate, a non-specific marker of inflammation. Used with citrated or diluted EDTA blood, filled to exactly 200 mm, placed vertically in Westergren stand, and read at 60 minutes. Primary clinical applications include determination of ESR for diagnosing and monitoring inflammatory conditions (infections, autoimmune disorders, malignancies), monitoring disease activity in rheumatoid arthritis, assessment of temporal arteritis and polymyalgia rheumatica, evaluation of infection and inflammatory response, screening for occult inflammatory conditions, and monitoring chronic inflammatory diseases (SLE, IBD, vasculitis). Critical safety precautions include handling glass tubes carefully to avoid breakage (sharps hazard), proper disposal in sharps containers as biohazardous waste, ensuring vertical alignment and constant temperature (18-25°C), reading at exactly 60 minutes, and avoiding air bubbles and vibration. Essential consumable for reference Westergren ESR testing in clinical laboratories.
Finecare Analyzer
$1.00
The Finecare Analyzer is a Class II medical device (FDA-cleared, CE-marked) fluorescence immunoassay system manufactured by Wondfo Biotech for quantitative detection of cardiac markers (troponin I, CK-MB, myoglobin), inflammatory markers (CRP, procalcitonin), thyroid hormones (TSH, FT3, FT4), diabetes markers (HbA1c), reproductive hormones (LH, FSH, prolactin), tumor markers (AFP, CEA, PSA), and infectious disease markers. Features include time-resolved fluorescence technology, color touchscreen interface, built-in printer (select models), USB/Ethernet connectivity, and internal rechargeable battery for portable use. Test time 3-15 minutes, sample volume 50-100 µL (whole blood, serum, plasma). Primary clinical applications include rapid diagnosis of acute myocardial infarction in chest pain patients, early detection of sepsis and bacterial infections, thyroid disorder diagnosis and monitoring, long-term glycemic control assessment in diabetes, fertility and reproductive health evaluation, cancer screening and surveillance, and infectious disease testing in endemic and clinical settings. Critical safety precautions include proper test cartridge storage (2-8°C), regular quality control, biohazard safety protocols, and operator training. Essential point-of-care testing system for hospitals, clinics, and remote healthcare facilities requiring rapid, quantitative results.
H.pylori test kits (Antigen)
$1.00
H.pylori test kits (Antigen) are Class II medical devices (FDA-cleared/CE-marked) for rapid immunochromatographic or enzyme immunoassay detection of Helicobacter pylori antigens in stool specimens, enabling non-invasive diagnosis of active infection and post-treatment eradication confirmation. Test principles use monoclonal or polyclonal antibodies specific to H. pylori antigens, producing visible results in 10-20 minutes (rapid tests) or 1-2 hours (EIA). Sensitivity 90-98%, specificity 92-99% compared to gold standard methods. Primary clinical applications include rapid diagnosis of H. pylori infection in patients with dyspepsia, initial screening in uncomplicated dyspepsia (test-and-treat strategy), confirmation of active infection before therapy, post-treatment eradication confirmation (4-6 weeks after therapy), pediatric testing (preferred non-invasive method), screening in high-risk populations (family history of gastric cancer), and monitoring in patients with peptic ulcer disease or MALT lymphoma. Critical safety precautions include mandatory washout period (4 weeks off antibiotics, 2 weeks off PPIs) to avoid false negatives, proper specimen handling (universal precautions), refrigerated storage of kits (2-30°C), quality control verification, and disposal as biohazardous waste. Essential non-invasive tool for H. pylori management in gastroenterology and primary care.
Hepatitis B Test Kit
$1.00
The Hepatitis B Test Kit is an in vitro diagnostic device for the detection of Hepatitis B virus markers in human blood samples, available in rapid, ELISA, and molecular formats. It detects specific antigens (HBsAg) and antibodies (anti-HBc, anti-HBs) to diagnose acute and chronic infection, monitor treatment response, screen blood donations, and determine immunity status. With high sensitivity (>98%) and specificity (>99%), it provides results in 15 minutes to 4 hours depending on format. Essential applications include prenatal screening to prevent mother-to-child transmission, evaluation of acute hepatitis, pre-immunosuppression screening, and occupational health testing. All patient samples must be handled with universal precautions, and testing must include appropriate quality controls.
Rheumatoid factor
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties