Showing all 9 results

Electronic Bottle-Top Dispenser (dFlow-Pro)

The Electronic Bottle-Top Dispenser (dFlow-Pro) is a fully digital, motor-controlled liquid handling system engineered for superior precision, efficiency, and user safety. It features a high-quality stepper motor that delivers highly accurate dispensing (R=0.2%, CV=0.07%)  with a wide volume range of 0.01 to 99.99 mL , making it suitable for demanding clinical chemistry and pharmaceutical QC workflows.
For the clinical laboratory scientist, the "Pro" series offers enhanced accuracy and "Dispenser" and "Stepper" operating modes to streamline high-throughput tasks, from QC sample preparation to plate-filling for ELISA assays. The remote control panel operates without manual disturbance , while the large LCD screen  ensures easy setup. For the laboratory manager, the "Pro" model's superior precision reduces costly reagent waste and re-runs, and its motorized drive  significantly mitigates the risk of repetitive strain injuries among staff, promoting a safer workplace. For the patient, the use of this dispenser in diagnostic labs translates directly to faster turnaround times and more reliable results, as the accuracy and reproducibility of the analytical process are enhanced.

Heating Mantle for 1000mL Beaker (HB1000)

The Heating Mantle for 1000mL Beaker (HB1000) is a dedicated, form‑fitting electric heating mantle engineered for safe, uniform, and efficient heating of 1000 mL beakers in clinical chemistry, pharmaceutical quality control, analytical chemistry, and medical laboratory science education. With a precisely machined inner diameter (118.75 mm) for optimal thermal contact, this heating mantle provides a maximum temperature of 450 °C and a power consumption appropriately scaled for 1000mL capacity, making it ideal for larger‑scale sample digestion, bulk reagent preparation, high‑throughput buffer heating, and educational large‑volume teaching demonstrations.
Every Heating Mantle for 1000mL Beaker (HB1000) features an enclosed heating element embedded within a chemically resistant fiberglass chamber, which provides excellent thermal insulation while protecting the user from burns and the element from chemical spills. The rigid outer metal housing ensures durability for heavy clinical diagnostic laboratory demands, and the bottom‑entry port allows connection of an optional temperature probe for precise temperature monitoring. The unit is typically sold with an external analog or digital controller for adjustable heating intensity.
Key user‑focused features include uniform heat distribution across the beaker wall, which prevents localized overheating and ensures reproducible results; fiberglass insulation that keeps the external housing at a safe temperature; chemical spill resistance that absorbs small spills without short‑circuiting; and a form‑fitting design that securely holds the beaker in place. The larger 1000 mL beaker format allows for unobstructed observation of boiling, dissolution, and crystallization phenomena directly through the glassware while supporting higher throughput or larger batch sizes.
For the clinical chemistry technologist, toxicology analyst, pharmaceutical quality control scientist, and teaching laboratory instructor, the Heating Mantle for 1000mL Beaker (HB1000) delivers the safe, uniform, and efficient heating required for larger‑volume sample digestion for trace element analysis (blood lead, urine cadmium), bulk buffer and reagent preparation, large‑scale dissolution testing simulation, and teaching fundamental heating techniques at a teaching laboratory scale. For the patient, reliable and reproducible heating ensures that diagnostic test results for heavy metal poisoning, metabolic disorders, and pharmaceutical products are accurate and consistent, directly supporting effective clinical decision‑making and patient safety.

Heating Mantle for 100mL Beaker (HB100)

The Heating Mantle for 100mL Beaker (HB100) is a dedicated, form‑fitting electric heating mantle engineered for safe, uniform, and efficient heating of 100mL beakers in clinical chemistry, pharmaceutical quality control, analytical chemistry, and medical laboratory science education. With a precisely machined inner diameter of 54.75mm for optimal thermal contact, this heating mantle provides a maximum temperature of 450°C and power consumption appropriately scaled for 100mL capacity, making it ideal for small‑volume sample digestion, small‑batch reagent preparation, limited‑volume solvent heating, and compact benchtop‑sized teaching demonstrations.
Every Heating Mantle for 100mL Beaker (HB100) features an enclosed heating element embedded within a chemically resistant fiberglass chamber, which provides excellent thermal insulation while protecting the user from burns and the element from chemical spills. The rigid outer metal housing ensures durability for clinical diagnostic laboratory demands, and the bottom‑entry port allows connection of an optional temperature probe for precise temperature monitoring. The unit is typically sold with an external analog or digital controller for adjustable heating intensity.
Key user‑focused features include uniform heat distribution across the beaker wall, which prevents localized overheating and ensures reproducible results; fiberglass insulation that keeps the external housing at a safe temperature; chemical spill resistance that absorbs small spills without short‑circuiting; and a form‑fitting design that securely holds the beaker in place. The smaller 100mL beaker format allows for unobstructed observation of boiling, dissolution, and crystallization phenomena directly through the glassware while supporting precious or limited‑volume specimens.
For the clinical chemistry technologist, toxicology analyst, pharmaceutical quality control scientist, and teaching laboratory instructor, the Heating Mantle for 100mL Beaker (HB100) delivers the safe, uniform, and efficient heating required for small‑volume sample digestion for trace element analysis (pediatric blood lead, cerebrospinal fluid metals), small‑batch reagent preparation, small‑scale dissolution testing simulation, and teaching fundamental heating techniques at the individual student workstation level. For the patient, reliable and reproducible heating ensures that diagnostic test results for heavy metal poisoning in pediatric populations, metabolic disorders in limited specimen volumes, and pharmaceutical product quality during early validation are accurate and consistent, directly supporting effective clinical decision‑making and patient safety.

Heating Mantle for 250mL Beaker (HB250)

The Heating Mantle for 250mL Beaker (HB250) is a dedicated, form-fitting electric heating mantle engineered for safe, uniform, and efficient heating of 250 mL beakers in clinical chemistry, pharmaceutical quality control, analytical chemistry, and educational laboratories. With a precisely machined inner diameter of 72.75 mm to ensure optimal thermal contact, this heating mantle provides a maximum temperature of 450°C and a maximum power consumption of 150W, making it ideal for sample digestion, reagent preparation, dissolution testing, and general laboratory heating applications.
Every  Heating Mantle for 250mL Beaker (HB250) features an enclosed heating element embedded within a chemically resistant fiberglass chamber, which provides excellent thermal insulation while protecting the user from burns and the element from chemical spills. The rigid outer metal housing ensures durability, and the bottom-entry port allows connection of an optional temperature probe for precise temperature monitoring. The unit is typically sold with an external analog or digital controller for adjustable heating intensity.
Key user-focused features include uniform heat distribution across the beaker wall, which prevents localized overheating and ensures reproducible results; fiberglass insulation that keeps the external housing at a safe temperature; chemical spill resistance that absorbs small spills without short-circuiting; and a form-fitting design that securely holds the beaker in place. The beaker format allows for unobstructed observation of boiling, dissolution, and crystallization phenomena directly through the glassware.
For the clinical chemistry technologist, toxicology analyst, and pharmaceutical quality control scientist, the  Heating Mantle for 250mL Beaker (HB250) delivers the safe, uniform, and efficient heating required for sample digestion for trace element analysis, buffer and reagent preparation, dissolution testing simulation, and teaching fundamental heating techniques. For the patient, reliable and reproducible heating ensures that diagnostic test results for heavy metal poisoning, metabolic disorders, and pharmaceutical products are accurate and consistent, directly supporting effective clinical decision-making and patient safety.

Heating Mantle for 500mL Beaker (HB500)

The Heating Mantle for 500mL Beaker (HB500) is a dedicated, form‑fitting electric heating mantle engineered for safe, uniform, and efficient heating of 500 mL beakers in clinical chemistry, pharmaceutical quality control, analytical chemistry, and educational laboratories. With a precisely machined inner diameter for optimal thermal contact, this heating mantle provides a maximum temperature of 450 °C and a power consumption of approximately 200–250 W, making it ideal for larger‑scale sample digestion, reagent preparation, dissolution testing, and general laboratory heating applications.
Every Heating Mantle for 500mL Beaker (HB500) features an enclosed heating element embedded within a chemically resistant fiberglass chamber, which provides excellent thermal insulation while protecting the user from burns and the element from chemical spills. The rigid outer metal housing ensures durability, and the bottom‑entry port allows connection of an optional temperature probe for precise temperature monitoring. The unit is typically sold with an external analog or digital controller for adjustable heating intensity.
Key user‑focused features include uniform heat distribution across the beaker wall, which prevents localized overheating and ensures reproducible results; fiberglass insulation that keeps the external housing at a safe temperature; chemical spill resistance that absorbs small spills without short‑circuiting; and a form‑fitting design that securely holds the beaker in place. The larger 500 mL beaker format allows for unobstructed observation of boiling, dissolution, and crystallization phenomena directly through the glassware while supporting higher throughput or larger batch sizes.
For the clinical chemistry technologist, toxicology analyst, and pharmaceutical quality control scientist, the Heating Mantle for 500mL Beaker (HB500) delivers the safe, uniform, and efficient heating required for larger‑volume sample digestion for trace element analysis, buffer and reagent preparation, dissolution testing simulation, and teaching fundamental heating techniques at a larger scale. For the patient, reliable and reproducible heating ensures that diagnostic test results for heavy metal poisoning, metabolic disorders, and pharmaceutical products are accurate and consistent, directly supporting effective clinical decision‑making and patient safety.

Heating Plate (DHP4-550)

The Heating Plate (DHP4-550) is a compact, precision benchtop heating instrument engineered for accurate, safe, and reproducible heating of clinical samples, reagents, biological specimens, and laboratory solutions in clinical diagnostics, molecular biology, microbiology, and pharmaceutical research. Featuring a 4-inch (100×100 mm) glass ceramic work plate that resists strong acids, strong alkalis, and high temperatures, this hot plate provides a temperature range from room temperature up to 550°C with ±1°C temperature control accuracy and 1°C setting increments.
Every Heating Plate (DHP4-550) is equipped with an integrated LCD display that simultaneously shows set temperature and real-time temperature, a programmable timer from 1 minute to 99 hours 59 minutes that automatically stops heating on completion, and a safety lock to prevent accidental changes to operating status. The PT1000 external temperature sensor port (±0.2°C accuracy, sensor sold separately) enables precise temperature control of the liquid or vessel surface rather than just the work plate for sensitive applications.
Key safety features include dual independent safety circuits that continuously monitor sensor status, temperature, and electrical conditions; user-adjustable maximum safety temperature to prevent overheating; and automatic shutdown with buzzer and error message if sensor failure, over-temperature, or electrical fault is detected. The corrosion-resistant all-metal housing provides good heat dissipation and fire protection, while the raised waterproof edge and drainage platform prevent liquid spills from entering internal electronics.
The Heating Plate (DHP4-550) is constructed with a glass ceramic work plate that withstands strong acids, strong alkalis, and temperatures up to 550°C without degradation. The all-metal chassis is also corrosion-resistant, and the non-slip rubber feet ensure stability during operation.
For the clinical laboratory scientist, clinical chemistry technologist, and microbiology specialist, the Heating Plate (DHP4-550) delivers the precise, safe, and reproducible heating required for clinical sample digestion, immunoassay incubation, microbiological media preparation, protein denaturation, and DNA denaturation workflows. For the patient, accurate and consistent sample preparation using precisely controlled heating ensures that downstream diagnostic test results are reliable and reproducible, directly supporting effective clinical decision-making and appropriate patient care.

LCD Digital Heating Magnetic Stirrer (MS-H-ProA )

The DLAB MS-H-ProA LCD Digital Heating Magnetic Stirrer is a high-performance, programmable benchtop instrument engineered for reliable, precise, and safe heating and stirring in clinical diagnostics, pharmaceutical quality control, analytical chemistry, and life science research. Combining a maximum stirring capacity of 20 liters with a powerful heating capability up to 340°C, the LCD Digital Heating Magnetic Stirrer is the ideal choice for a wide array of demanding laboratory applications, from routine solution preparation to complex chemical synthesis.

Every LCD Digital Heating Magnetic Stirrer is equipped with a high-resolution LCD display that simultaneously shows the set and actual values for both temperature and speed, a maintenance-free brushless DC motor, and a PID temperature controller. The 5-inch (φ135 mm) ceramic-coated aluminum work plate ensures fast, uniform heating and provides excellent chemical resistance. With an integrated PT1000 temperature sensor port, users can accurately control sample temperature at ±0.2°C, making it suitable for temperature-sensitive assays.

Key user-focused features include three selectable heating modes—fast heating, standard heating, and stable heating—allowing users to choose the optimal thermal profile for their specific application. The programmable timer, ranging from 1 minute to 99 hours 59 minutes, allows for unattended operation. Safety is paramount with two independent safety circuits (420°C over-temperature protection), an independent residual heat warning indicator (>50°C), and an IP21-rated housing for basic spill and particle protection. The RS232 data interface enables remote PC control and data logging.

For the clinical laboratory scientist and quality control analyst, the LCD Digital Heating Magnetic Stirrer delivers the programmable, precise, and safe heating and stirring required for clinical chemistry workflows, buffer and reagent preparation, sample digestion, and dissolution testing. For the patient, the reliable performance of this instrument ensures that diagnostic tests, pharmaceutical products, and food supplies are prepared consistently and accurately, directly supporting effective public health and patient safety.

LCD Digital Hotplate (HP380-Pro)

The LCD Digital Hotplate (HP380-Pro) is a high-performance, stand-alone benchtop heating instrument engineered for accurate, safe, and efficient heating in clinical diagnostics, pharmaceutical quality control, analytical chemistry, and life science research. Featuring a 6‑inch (140×140mm) ceramic-coated aluminium work plate, this hotplate delivers a wide temperature range from room temperature +5°C up to 380°C (±1°C increments) for demanding applications including sample digestion for trace element analysis (blood lead, urine cadmium, heavy metals), buffer and culture media preparation, protein denaturation for enzymatic assays, and general solution heating.
Every LCD Digital Hotplate (HP380-Pro) is calibrated according to DLAB’s quality management system and supplied with a calibration certificate traceable to international standards, delivering a temperature display accuracy of ±0.1°C and a PID controller for precise, stable heating without overshoot. The high-resolution LCD display simultaneously shows the actual plate temperature (and timer, when set) at a glance, providing real-time monitoring without toggling between modes.
Key user‑focused safety features include an independent 420°C over‑temperature protection sensor that automatically shuts off heating to prevent fire hazards and sample damage, a residual heat warning indicator that remains active after the instrument is turned off (plate >50°C) to protect users from burn hazards, and a TÜV-certified compliance (CE, cTUVus, FCC) meeting DIN/EN 60529 international safety standards. The optional PT1000 external temperature sensor (PT1000-A, PT1000-B, or PT1000-C, sold separately) provides ±0.2°C accuracy for controlling the actual temperature of the sample liquid rather than just the plate.
The work plate’s aluminium core with durable ceramic coating provides rapid, uniform heating and excellent chemical resistance against strong acids, strong alkalis, and organic solvents, while remaining easy to clean after spills. The IP21-rated housing offers basic splash and particulate protection in busy laboratory environments. The integrated timer function (displayed on the LCD) allows for timed heating protocols and unattended operation when used with appropriate laboratory safety protocols.
For the clinical laboratory scientist, toxicology analyst, and pharmaceutical quality control scientist, the LCD Digital Hotplate (HP380-Pro) delivers the precise, safe, and reproducible heating required for critical workflows. For the patient, reliable and reproducible heating ensures that diagnostic tests for heavy metal toxicity, metabolic disorders, infectious diseases, and pharmaceutical products are accurate and consistent, directly supporting effective clinical decision-making, appropriate treatment selection, and patient safety.

TopPette Single-Channel Adjustable Volume Pipette

The TopPette Single-Channel Adjustable Volume Pipette is a high-performance manual mechanical pipette engineered for accuracy, reproducibility, and operator comfort in clinical diagnostics, molecular biology, and pharmaceutical research. Available in nine volume ranges from 0.1 µL to 10 mL, this pipette provides the versatility required for micro-volume PCR setup, routine clinical chemistry, and large-volume reagent preparation.
Every TopPette is calibrated according to ISO 8655 and supplied with an individual calibration certificate, delivering exceptional accuracy (e.g., systematic error as low as ±2.5% at 2.5 µL) and precision (CV as low as ±1.5% at the same volume). The lower assembly on select models is fully autoclavable at 121°C for 20 minutes, ensuring sterility for aseptic applications in cell culture and microbiology.
Key ergonomic features include a lightweight body, a low-force plunger, a relaxed finger hook, and a smooth volume adjustment knob with a locking mechanism. A large digital display provides unambiguous volume confirmation, and the universal tip cone works with most standard pipette tips.
For the clinical laboratory scientist and medical technologist, the TopPette delivers the accuracy, reproducibility, and ergonomic comfort required for routine ELISA, PCR, clinical chemistry, and blood bank testing. For the patient, consistent, error-free sample processing ensures that diagnostic results are reproducible, reliable, and delivered with faster turnaround times, directly supporting timely and effective clinical decision making.