TopPette Single-Channel Adjustable Volume Pipette

WhatsApp Order
The TopPette Single-Channel Adjustable Volume Pipette is a high-performance manual mechanical pipette engineered for accuracy, reproducibility, and operator comfort in clinical diagnostics, molecular biology, and pharmaceutical research. Available in nine volume ranges from 0.1 µL to 10 mL, this pipette provides the versatility required for micro-volume PCR setup, routine clinical chemistry, and large-volume reagent preparation.
Every TopPette is calibrated according to ISO 8655 and supplied with an individual calibration certificate, delivering exceptional accuracy (e.g., systematic error as low as ±2.5% at 2.5 µL) and precision (CV as low as ±1.5% at the same volume). The lower assembly on select models is fully autoclavable at 121°C for 20 minutes, ensuring sterility for aseptic applications in cell culture and microbiology.
Key ergonomic features include a lightweight body, a low-force plunger, a relaxed finger hook, and a smooth volume adjustment knob with a locking mechanism. A large digital display provides unambiguous volume confirmation, and the universal tip cone works with most standard pipette tips.
For the clinical laboratory scientist and medical technologist, the TopPette delivers the accuracy, reproducibility, and ergonomic comfort required for routine ELISA, PCR, clinical chemistry, and blood bank testing. For the patient, consistent, error-free sample processing ensures that diagnostic results are reproducible, reliable, and delivered with faster turnaround times, directly supporting timely and effective clinical decision making.
Description

TopPette Single-Channel Adjustable Volume Pipette

PRIMARY CLINICAL & DIAGNOSTIC USES

1. High-Precision Liquid Handling for Routine Clinical Assays
Primary Use: Provides a manual, single-channel adjustable volume pipette with a lightweight ergonomic body and a digital volume display, used for the accurate and reproducible transfer of patient samples, reagents, calibrators, and controls in routine clinical chemistry, immunoassays, and molecular diagnostics.
How it helps: For the clinical laboratory scientist and medical technologist, the TopPette’s precision piston mechanism delivers systematic error as low as ±2.5% and random error as low as ±1.5% at low volumes (e.g., 2.5 µL), ensuring consistent sample and reagent delivery. The clear digital volume window and smooth adjustment knob minimize setting errors. For the patient, this accuracy directly supports reliable results for critical diagnostic tests such as blood glucose, lipid panels, cardiac enzymes, and infectious disease serology, reducing the risk of misdiagnosis or repeat testing.
2. Versatile Volume Range for Diverse Clinical Applications
Primary Use: Covers a broad volume range from 0.1 µL to 10 mL across multiple models (0.1–2.5 µL, 0.5–10 µL, 2–20 µL, 5–50 µL, 10–100 µL, 20–200 µL, 100–1000 µL, 1000–5000 µL, 1000–10000 µL), allowing the same pipette family to be used for micro-volume PCR setup, medium-volume reagent addition, and large-volume media or buffer preparation.
How it helps: For the laboratory manager, a single pipette platform simplifies inventory management and training across multiple diagnostic applications. Each TopPette is calibrated according to ISO 8655 and supplied with an individual calibration certificate, ready for immediate use. For the patient, the ability to use trusted, consistent instruments across all testing platforms ensures that each sample receives uniform, high-quality handling from extraction to final readout.
3. Ergonomic Design to Minimize Operator Fatigue
Primary Use: Features a lightweight, chemically resistant polymer body, a low-force plunger, a relaxed finger rest, and a contoured handle designed for both right-handed and left-handed users, with a large digital display for unambiguous volume confirmation.
How it helps: For the high-throughput laboratory staff performing hundreds to thousands of pipetting steps daily, the ergonomic design reduces the risk of repetitive strain injury (RSI) and hand fatigue. The smooth plunger action and low ejection force allow comfortable operation over extended shifts. For the patient, this fatigue-reducing design contributes to consistent, error-free sample handling throughout the day, supporting day-to-day reproducibility of diagnostic test results.
4. Autoclavable Lower Assembly for Aseptic Work
Primary Use: The lower portion of the pipette (tip cone and piston assembly) is constructed from autoclavable materials and can be steam-sterilized at 121°C for 20 minutes without disassembly on select models, and the entire pipette body is UV-resistant for routine disinfection.
How it helps: For the cell culture specialist and microbiology technologist, the ability to autoclave the tip cone assembly eliminates the risk of cross-contamination between sensitive cell lines, sterile reagents, or microbial cultures. For the patient, rigorous sterilization of pipetting equipment ensures that specimens and cell-based products are not adulterated by contaminants, maintaining the safety and integrity of diagnostic tests and therapies.

SECONDARY & SUPPORTIVE USES

1. ELISA and immunoassay reagent dispensing: Transfers coating antibodies, blocking buffers, primary antibodies, enzyme conjugates, and substrate solutions into 96-well plates with high accuracy, ensuring uniform well-to-well development for clinical immunology testing.
2. qPCR and PCR master mix preparation: Delivers precise volumes of master mix, primers, probes, template DNA, and nuclease-free water into reaction tubes or plates, minimizing evaporation and cross-contamination for reliable amplification.
3. DNA and RNA extraction procedures: Transfers lysis buffers, binding buffers, wash buffers, and elution solutions during manual or automated nucleic acid purification from blood, tissue, or swab samples.
4. Cell culture media and supplement addition: Adds sterile media, fetal bovine serum, antibiotics, glutamine, and other growth supplements to culture flasks, dishes, or multi-well plates under aseptic conditions.
5. Protein quantification assays: Dispenses Bradford, BCA, or Lowry reagents into cuvettes or microplates, and adds protein standards and samples for concentration determination in research and QC laboratories.
6. Clinical chemistry sample transfer: Transfers patient serum, plasma, or urine from primary collection tubes to analyzer cups, microcuvettes, or multi-well plates for routine chemistry, electrolyte, and metabolite testing.
7. Blood bank and transfusion medicine: Pipettes red blood cell suspensions, antisera, reagent red cells, and saline for ABO/Rh typing, antibody screening, and compatibility testing with high reproducibility.
8. Pharmaceutical quality control: Delivers test solutions, dissolution samples, and QC standards for HPLC, UV-Vis, or other analytical methods where precise volume transfer is mandatory for regulatory compliance.
9. Food safety and environmental testing: Prepares food homogenates, environmental swab eluates, and enrichment broths for pathogen detection assays such as Salmonella, Listeria, and coliform quantification.
10. Forensic DNA analysis: Transfers extracted DNA, PCR products, and allelic ladders for STR profiling in forensic casework, where microliter precision and contamination control are critical.
11. Veterinary diagnostic testing: Processes animal blood, serum, tissue homogenates, and fecal samples for infectious disease testing, vaccine response monitoring, and genetic screening.
12. Drug discovery and compound screening: Dispenses assay buffers, cell suspensions, test compounds, and detection reagents into 96-well or 384-well plates for high-throughput screening campaigns.
13. Academic research and teaching: Serves as a durable, intuitive teaching tool for students learning fundamental pipetting techniques in molecular biology, biochemistry, and clinical laboratory science courses.
14. Next-generation sequencing library preparation: Transfers adapter mixes, indexing reagents, and bead suspensions for size selection and purification during NGS library construction.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A manual, mechanical air-displacement pipette with an adjustable volume mechanism, available in single-channel configuration across nine volume ranges.
  • Designation: TopPette Single-Channel Adjustable Volume Pipette, DLAB TopPette, TopPette Manual Pipette.
  • Key Components:
    • Lightweight, chemically resistant polymer body
    • Digital volume display window with three-digit readout
    • Smooth volume adjustment knob with locking mechanism
    • Low-force plunger with clearly defined first and second stops
    • Ergonomic finger hook and contoured handle
    • Tip ejector lever for one-handed tip removal
    • Universal tip cone compatible with standard pipette tips
    • Autoclavable lower assembly (select models)

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Available volume ranges: 0.1–2.5 µL, 0.5–10 µL, 2–20 µL, 5–50 µL, 10–100 µL, 20–200 µL, 100–1000 µL, 1000–5000 µL, 1000–10000 µL
  • Example accuracy (0.1–2.5 µL model at 2.5 µL): Systematic error ±2.5% (±0.0625 µL); random error (CV) ±1.5% (±0.0375 µL)
  • Example accuracy (2–20 µL model at 10 µL): Systematic error ±1.0% (±0.1 µL); random error (CV) ±0.6% (±0.06 µL)
  • Example accuracy (100–1000 µL model at 500 µL): Systematic error ±0.7% (±3.5 µL); random error (CV) ±0.3% (±1.5 µL)
  • Example accuracy (1000–5000 µL model at 5000 µL): Systematic error ±0.6% (±30 µL); random error (CV) ±0.3% (±15 µL)
  • Sterilization: Lower assembly (tip cone and piston) autoclavable at 121°C, 1 bar for 20 minutes on select models; upper body UV-resistant for disinfection
  • Volume adjustment: Smooth rotating knob with digital display window and volume locking mechanism
  • Tip compatibility: Universal tip cone works with most standard pipette tips from major manufacturers
  • Quality compliance: Calibrated according to ISO 8655; each pipette supplied with individual calibration certificate; CE marked

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Lightweight, chemical-resistant polymer body with smooth, easy-to-clean surface
  • Operation: Manual, thumb-actuated plunger with clearly defined first and second stops
  • Weight: Approximately 0.08–0.12 kg depending on volume range (very lightweight)
  • Volume display: Large, clear digital window with three-digit readout for unambiguous volume setting; the last digit changes color on some models to indicate decimal placement
  • Volume locking: Built-in lock prevents accidental volume changes during pipetting
  • Tip ejection: Quick-release, spring-assisted ejector for safe, one-handed tip removal
  • Finger rest: Relaxed, ergonomic finger hook for comfortable extended operation
  • Maintenance: User-calibratable using standard tools; online calibration service available; replacement O-rings and seals available
  • Portability: Compact design for easy storage in pipette stands, carousels, or drawers

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic (IVD) use; manufactured under ISO 9001 and ISO 13485 quality systems
  • Chemical Resistance: Constructed from advanced polymers that resist a wide range of laboratory chemicals, acids, bases, alcohols, and common buffers
  • Autoclaving Safety: Lower assembly can be autoclaved at 121°C for 20 minutes; after autoclaving, allow to dry for at least 12 hours and lubricate piston if necessary
  • Tip Seal Verification: Clear tip cone design allows visual verification of tip seating, reducing leakage and inaccurate volume delivery
  • Quality Compliance: Each pipette individually tested and supplied with an ISO 8655-compliant calibration certificate; can be recertified online
  • Ergonomic Safety: Low-force plunger and lightweight design reduce risk of repetitive strain injury (RSI) during routine and high-throughput work

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store upright in a pipette stand to protect the tip cone; both linear and carousel stands are available separately
  • Cleaning: Wipe exterior surfaces with 70% isopropyl alcohol or a mild detergent solution; do not immerse the pipette in liquid
  • Autoclaving: Remove the lower assembly (if autoclavable model) and autoclave at 121°C, 1 bar for 20 minutes; allow to cool and dry for at least 12 hours before reassembly. Lubricate piston after every 10 autoclave cycles
  • Volume setting: Unlock the volume lock, rotate the adjustment knob until the desired volume appears in the digital window, then relock
  • Tip loading: Press the pipette vertically into a tip to seat it; avoid rocking or excessive tapping to prevent tip cone damage
  • Aspiration technique: Depress plunger to the first stop, immerse the tip below the liquid surface, release the plunger slowly and smoothly
  • Dispensing technique: Place the tip against the receiving vessel wall, depress plunger to the first stop, wait one second, then press to the second stop to expel any residual liquid
  • Pre-use inspection: Inspect the tip cone, O-rings, and piston for wear or damage; check for smooth plunger operation
  • Calibration verification: Perform periodic calibration checks using a balance and distilled water according to ISO 8655 guidelines; calibration tools are supplied or available online
  • Lubrication: Apply silicone grease to the piston and seals as recommended by the manufacturer, especially after autoclaving or if plunger action becomes stiff

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Precision liquid handling for clinical diagnostics (clinical chemistry, immunoassays, molecular diagnostics), pharmaceutical quality control, cell culture, and general research, where accurate, reproducible manual pipetting is required.
  • Clinical Role: An essential instrument for clinical diagnostic laboratories, molecular diagnostics labs, immunology laboratories, blood banks, pathology departments, pharmaceutical QC facilities, and research institutions. Critical for patient sample processing, reagent preparation, and routine testing where consistent, error-free liquid handling is mandatory.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Chemical Compatibility: Verify that the pipette materials are compatible with the specific reagents used. Although designed for broad chemical resistance, some aggressive organic solvents may still affect seals.
  • Autoclaving Preparation: Only the lower assembly of autoclavable models should be sterilized. Do not autoclave the upper body or volume adjustment mechanism. After autoclaving, allow the instrument to cool and dry for at least 12 hours.
  • Tip Fit: Ensure the pipette tip is securely attached before aspirating; a loose tip may cause inaccurate volume delivery or sample loss.
  • Aspiration Technique: Release the plunger slowly and smoothly to prevent aspiration of air bubbles or splashing, which can lead to volume errors.
  • Avoid Dropping: Dropping the pipette may damage the internal piston mechanism and affect calibration; recalibrate if dropped.
  • Cleaning: Do not immerse the entire pipette in liquid; wipe exterior surfaces only.
  • Training: Only trained laboratory personnel should operate the TopPette for clinical diagnostic applications.

2. FIRST AID MEASURES

  • Sample Splash to Eyes: If a biological or chemical sample splashes into the eyes, flush immediately with water for 15 minutes and seek medical attention.
  • Skin Contact: Wash contaminated skin with soap and water thoroughly; if irritation or signs of infection develop, seek medical evaluation.
  • Sharps Injury: If a pipette tip punctures the skin (sharps injury), wash the wound thoroughly and follow the facility's exposure management protocol for bloodborne pathogens.
  • Chemical Exposure: If the pipette is contaminated with a hazardous chemical, refer to the specific Safety Data Sheet (SDS) for detailed first-aid instructions.
  • Inhalation: If chemical vapors are inhaled during reagent preparation, move to fresh air immediately; seek medical attention if symptoms persist.
  • Autoclave Burn: If handling the lower assembly immediately after autoclaving, use heat-resistant gloves; if a burn occurs, cool the area with cool running water for 15 minutes and seek medical attention.

3. FIRE FIGHTING MEASURES

  • Flammability: The plastic components of the pipette body and tip cone are combustible; they may melt or burn if exposed to flame or high heat.
  • Extinguishing Media: Use carbon dioxide (CO₂) or a dry chemical extinguisher for fires involving plastic materials.
  • Fire Response: The primary fire hazard is the flammable laboratory reagents being handled; follow the laboratory's fire safety protocols.