Showing all 2 results

Digital Dry Bath Single Block (HB150-S1)

The Digital Dry Bath Single Block (HB150-S1) is a compact benchtop dry thermostat with extended high-temperature capability up to 150°C, designed for advanced molecular biology applications, thermostable enzyme inactivation, and high-temperature diagnostic assay preparation in clinical and research laboratories . With a temperature range from room temperature +5°C to 150°C and temperature control accuracy of ±0.3°C (25-90°C) and ±0.6°C (90-150°C), this dry bath provides consistent, uniform heating for protocols requiring extreme temperatures up to 150°C—enabling specialized assays that cannot be performed on standard dry baths with lower maximum temperatures .
The HB150-S1 features a microprocessor-controlled system with LED display for real-time temperature and time monitoring, an intuitive control knob for simple operation without complex menus, and interchangeable aluminum heating blocks compatible with various tube formats including 0.2mL, 0.5mL, 1.5/2mL, 5mL, 15mL, and 50mL tubes . The unit supports both timing mode (0 to 99 hours 59 minutes) and continuous operation mode, with built-in overheating protection for equipment and sample safety .
Key advanced features include an external temperature sensor port (PT1000 compatible) for real-time sample temperature verification , USB interface for data export and quality record traceability , and a heat-preserving block lid that prevents contamination and ensures temperature stability . A sound reminder function alerts users when set temperature is reached and at run completion .
For the molecular biologist and clinical laboratory scientist, the HB150-S1 supports complete heat inactivation of thermostable restriction enzymes and heat-labile enzymes (preventing interference with downstream diagnostic assays), protein denaturation for SDS-PAGE and Western blotting at elevated temperatures, DNA denaturation for GC-rich templates and challenging PCR protocols, and high-temperature sample preparation with external temperature verification for quality assurance .
For the patient undergoing specialized molecular testing, the HB150-S1's extended temperature capability (up to 150°C) ensures complete inactivation of even thermostable enzymes, thorough DNA denaturation for the most challenging templates, and reliable high-temperature sample preparation with documented temperature verification—supporting accurate diagnostic results for complex genetic conditions, infectious diseases, and oncology testing that require extreme temperature control .

Digital Dry Bath Single Block(HB105-S1)

The Digital Dry Bath Single Block(HB105-S1) is a compact, single-block benchtop dry thermostat designed for precise temperature-controlled incubation in clinical diagnostic, molecular biology, and research laboratories . With a temperature range from room temperature +5°C to 105°C and temperature control accuracy of ±0.5°C, this dry bath provides consistent, uniform heating for a wide range of diagnostic and research applications .
The HB105-S1 features a microprocessor-controlled system with LED display for real-time temperature and time monitoring, an intuitive control knob for simple operation without complex menus, and interchangeable aluminum heating blocks compatible with various tube formats and sizes . The unit supports both timing mode (0 to 99 hours 59 minutes) and continuous operation mode, with built-in temperature self-calibration function for long-term accuracy .
For the clinical laboratory scientist and medical technologist, the HB105-S1 supports enzyme-substrate reactions for biochemical tests and clinical chemistry, serum inactivation (56°C) for immunoassays and serological testing, DNA denaturation for nucleic acid amplification and PCR preparation, and sample warming and reagent thawing for diagnostic testing . The compact, single-block design is ideal for space-constrained laboratories while delivering reliable heating performance .
Safety features include over-temperature protection and an insulated lid that prevents heat loss and contamination . For the patient undergoing diagnostic testing for infectious diseases, autoimmune disorders, or genetic conditions, the HB105-S1's precise temperature control ensures reliable enzyme reaction conditions, consistent DNA denaturation, and accurate sample preparation—supporting reliable test results that guide appropriate treatment decisions across clinical chemistry, molecular diagnostics, and research applications .