LED Overhead Stirrer (OS40-S)
WhatsApp Order
The LED Overhead Stirrer is a high-capacity LED digital overhead mechanical stirrer featuring a brushless DC motor (120W input / 100W output), microprocessor-controlled speed regulation (50-2200 rpm, accuracy ±3 rpm), LED display for real-time speed monitoring, enhanced torque (60 N·cm), and increased viscosity handling (up to 50,000 mPa·s), designed for demanding high-viscosity and large-volume (up to 40 liters) mixing, homogenizing, and suspending applications in clinical diagnostic, pharmaceutical, and research laboratories .
Key features include a maintenance-free, explosion-proof brushless DC motor for quiet, long-lasting operation and safe use in volatile environments; through-shaft design for easy impeller height adjustment; anti-spill slow-start mechanism to prevent sample splashing; overload protection (LED indicator lights, motor automatic stop in case of continuous overload) for equipment and sample safety; and compatibility with a wide range of stirrer shafts (0.5-10 mm chuck diameter) .
The LED Overhead Stirrer represents a significant upgrade from the LED Overhead Stirrer, with double the stirring capacity (40L vs 20L), double the output power (100W vs 50W), 50% higher torque (60 N·cm vs 40 N·cm), and five times higher viscosity handling (50,000 mPa·s vs 10,000 mPa·s), making it suitable for the most demanding high-viscosity applications .
For the pharmaceutical formulation scientist and quality control chemist, the LED Overhead Stirrer supports mixing of high-viscosity creams, ointments, gels, and suspensions at batch sizes up to 40L, API dissolution testing, and large-volume buffer and media preparation . For the biopharmaceutical manufacturing scientist, it enables processing of cell pastes, protein solutions, and fermentation broths with viscosity up to 50,000 mPa·s . For the clinical laboratory scientist, it facilitates bulk reagent preparation for high-volume immunoassays and clinical chemistry analyzers .
Universal voltage (100-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion, while the compact (83 × 220 × 186 mm) and lightweight (2.8 kg) design allows easy benchtop placement . The IP42-rated splash-resistant housing ensures safe operation in biosafety cabinets and fume hoods, including handling of biohazardous materials .
For the patient undergoing pharmaceutical therapy, the LED Overhead Stirrer enhanced torque and viscosity handling ensure consistent formulation quality, batch-to-batch uniformity, and accurate API release testing—supporting the manufacturing of safe, effective high-viscosity medications such as topical creams, ointments, and biopharmaceuticals . For patients requiring diagnostic testing, consistent large-volume reagent preparation reduces inter-run variability and improves the reliability of diagnostic test results across high-volume clinical chemistry, pharmaceutical QC, and analytical testing applications .
Description
LED Overhead Stirrer
PRIMARY CLINICAL & DIAGNOSTIC USES
1. High-Volume Pharmaceutical Formulation Development
-
Primary Use: Provides a high-capacity LED digital overhead stirrer with brushless DC motor (120W input / 100W output), speed range 50-2200 rpm, and maximum viscosity handling of 50,000 mPa·s, designed for demanding mixing of high-viscosity pharmaceutical formulations at large batch sizes up to 40 liters .
-
How it helps: For the pharmaceutical formulation scientist and quality control chemist, the LED Overhead Stirrer increased power output (100W vs 50W on LED Overhead Stirrer) and higher torque (60 N·cm) enable efficient mixing of high-viscosity pharmaceutical formulations such as creams, ointments, gels, and suspensions at larger batch sizes (up to 40L) . The LED display provides real-time monitoring of actual speed for precise control . For the patient, consistent high-volume formulation ensures that medications deliver the correct dosage and therapeutic effect with each use, particularly for high-viscosity topical preparations.
2. Large-Volume Clinical Reagent and Buffer Preparation
-
Primary Use: Capable of stirring volumes up to 40 liters (water) with maximum torque of 60 N·cm, enabling large-batch preparation of reagents, buffers, and clinical samples for high-throughput diagnostic testing workflows .
-
How it helps: For the clinical laboratory scientist and laboratory manager in high-volume reference laboratories, the LED Overhead Stirrer increased capacity (40L vs 20L on LED Overhead Stirrer) allows efficient preparation of bulk reagents for immunoassays, clinical chemistry analyzers, and molecular diagnostics—significantly reducing hands-on time and ensuring batch consistency across hundreds or thousands of patient samples . For the patient, consistent reagent preparation across large batches reduces inter-run variability and improves the reliability of diagnostic test results .
3. High-Viscosity Sample Processing for Biopharmaceutical Manufacturing
-
Primary Use: Capable of handling samples with viscosity up to 50,000 mPa·s, enabling homogenization and emulsification of highly viscous biological fluids, cell pastes, and biopharmaceutical formulations for quality control and manufacturing support .
-
How it helps: For the biopharmaceutical manufacturing scientist and quality control chemist, the OS40-S’s increased viscosity handling (50,000 mPa·s vs 10,000 mPa·s on OS20-S) ensures efficient processing of high-viscosity cell pastes, protein solutions, and fermentation broths—critical for downstream purification and formulation . For the patient, consistent high-viscosity sample processing ensures that biopharmaceutical products (monoclonal antibodies, vaccines, cell therapies) meet quality standards for safety and efficacy .
4. Safe Handling of High-Viscosity Biohazardous Materials
-
Primary Use: Features IP42 protection rating, splash-resistant design, overload protection with LED indicator and automatic motor stop, and anti-spill slow-start mechanism (PC control system smooth start-up), enabling safe handling of high-viscosity biohazardous materials in biosafety cabinets and fume hoods .
-
How it helps: For the clinical laboratory scientist and biosafety officer, the LED Overhead Stirrer splash-resistant housing protects against accidental spills of infectious materials, while overload protection (LED indicator lights, motor automatically stops in case of continuous overload) prevents motor damage and sample loss during high-viscosity mixing . The anti-spill slow-start mechanism gradually increases speed to prevent splashing . For the patient, safe handling of biohazardous materials in clinical and research laboratories reduces the risk of laboratory-acquired infections and ensures sample integrity .
5. High-Volume Buffer Preparation for Clinical Analyzers
-
Primary Use: Supports preparation of large volumes (up to 40L) of wash buffers, reagent solutions, and calibrators for automated clinical chemistry and immunoassay analyzers in high-throughput clinical laboratories .
-
How it helps: For the clinical laboratory scientist and automation specialist, the LED Overhead Stirrer large capacity and consistent mixing performance ensure that bulk reagents for automated analyzers are prepared with batch-to-batch uniformity—reducing re-calibration needs and improving analyzer uptime . For the patient, consistent reagent quality across large batches improves the reliability of routine diagnostic testing, from complete blood counts to cardiac enzyme panels .
SECONDARY & SUPPORTIVE USES
1. Chemical Synthesis and Reaction Mixing: Used for stirring chemical reactions in organic synthesis, polymerization, and drug discovery workflows requiring high torque and large volumes .
2. API Dissolution Testing: Supports stirring of dissolution media for active pharmaceutical ingredient (API) release testing in pharmaceutical quality control laboratories .
3. Cosmetic and Personal Care Product Formulation: Used for mixing creams, lotions, gels, and emulsions in cosmetic product development and quality control at batch sizes up to 40L .
4. Food and Beverage Product Testing: Supports sample homogenization and ingredient mixing for food safety testing and nutritional analysis of high-viscosity products .
5. Paints, Coatings, and Inks Quality Control: Used for mixing and dispersion of pigments, resins, and additives in paint, coating, and ink manufacturing .
6. Petroleum and Petrochemical Sample Preparation: Supports mixing of oil, fuel, and lubricant samples for viscosity testing and quality analysis .
7. Biopharmaceutical Buffer and Media Preparation: Used for large-volume preparation of cell culture media, buffers, and purification solutions in biopharmaceutical manufacturing up to 40L batches .
8. Environmental Sample Processing: Supports mixing of water, soil, and wastewater samples for pollutant analysis and environmental monitoring .
9. Polymer and Plastics Testing: Used for mixing polymer solutions, resins, and plastic additives for materials testing and quality control .
10. Adhesives and Sealants Formulation: Supports mixing of adhesives, epoxies, and sealants for product development and quality testing .
11. Pilot-Scale Production and Scale-Up: Used for small-batch production and scale-up studies in pharmaceutical, chemical, and food manufacturing pilot plants up to 40L .
12. Debubbling and Degassing of Viscous Liquids: Supports gentle stirring to remove air bubbles from viscous solutions and gels .
13. Quality Control Testing of Raw Materials: Used for mixing of incoming raw material samples for identity, purity, and quality testing of high-viscosity materials .
14. Research and Academic Laboratories: Provides reliable overhead stirring for diverse research applications in chemistry, biology, and materials science requiring high torque .
15. Veterinary Pharmaceutical Formulation: Supports mixing of veterinary drug formulations and medicated feeds for animal health testing .
16. Infection Control Disinfectant Production: Used for mixing bulk disinfectant solutions for healthcare facility infection control programs .
Healthcare Product Development: Supports stirring in R&D of new pharmaceutical treatments, vaccines, and healthcare products at pilot scale .
17. Solubility Testing for Drug Development: Supports dissolution and mixing in drug solubility studies for new pharmaceutical compounds requiring high shear .
18. Formulation Stability Testing: Used for mixing stability samples in pharmaceutical QC laboratories for shelf-life determination of high-viscosity products .
19. Pilot Bioprocessing: Supports mixing of fermentation broths and cell culture harvests in pilot-scale bioprocessing workflows .
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A high-capacity LED digital overhead stirrer (overhead mechanical stirrer) with brushless DC motor, microprocessor control, and enhanced torque (60 N·cm) and viscosity (50,000 mPa·s) handling, designed for demanding high-viscosity and large-volume (up to 40L) mixing, homogenizing, and suspending applications in clinical diagnostic, pharmaceutical, and research laboratories .
-
Designation: LED Overhead Stirrer, LED Digital Overhead Stirrer, High-Torque Overhead Stirrer, Laboratory Stirrer, DLAB LED Overhead Stirrer, Digital Electric Overhead Stirrer .
-
Key Components:
o Motor: Brushless DC motor (maintenance-free, explosion-proof, low noise) .
o Motor Power: 120W input / 100W output .
o Speed Control: Microprocessor-controlled, 50-2200 rpm, accuracy ±3 rpm .
o Display: LED digital display (actual speed monitoring) .
o Chuck: 0.5-10 mm chuck diameter for various stirrer shafts .
o Through-Shaft Design: Allows easy adjustment of impeller position .
o Safety Features: Overload protection (LED indicator lights, motor automatic stop), anti-spill slow-start mechanism, IP42 protection rating .
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Maximum Stirring Capacity: 40 liters (H₂O) .
-
Maximum Viscosity: 50,000 mPa·s .
-
Maximum Torque: 60 N·cm .
-
Speed Range: 50 – 2,200 rpm .
-
Speed Display Resolution: ±1 rpm .
-
Speed Control Accuracy: ±3 rpm .
-
Motor Type: Brushless DC motor (maintenance-free, low noise, explosion-proof) .
-
Motor Input Power: 120W .
-
Motor Output Power: 100W .
-
Total Power Consumption: 130W .
-
Chuck Diameter Range: 0.5 – 10 mm .
-
Voltage/Frequency: 100-240V, 50/60Hz (universal voltage) .
-
Dimensions (W × D × H): 83 × 220 × 186 mm .
-
Weight: 2.8 kg .
-
Protection Class: IP42 (splash-resistant, protection against solid objects >1mm) .
-
Operating Temperature: 5-40°C .
-
Permissible Ambient Humidity: ≤80% RH .
-
Overload Protection: LED lights, motor automatically stops in case of continuous overload .
-
Motor Protect: LED lights, motor automatically stops .
-
Stirrer Shaft Compatibility: Through-shaft design accepts various stirrer shafts .
-
Accessories (Sold Separately): Universal plate stand (base + rod + clamp), various stirrer impellers (propeller, anchor, flat blade, PTFE-coated, 316L stainless steel) .
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: Compact benchtop design with durable housing and through-shaft chuck for easy impeller height adjustment .
-
Display: LED digital display shows actual speed in real-time; overload protection LED indicator lights .
-
Control: Microprocessor-controlled with smooth acceleration; anti-spill slow-start mechanism prevents sample splashing; start/stop push-button; speed adjustment via rotary knob with positive stop .
-
Operation Modes: Continuous operation (manual control) .
-
Motor Type: Brushless DC motor provides low noise, maintenance-free, explosion-proof operation, long life, and high reliability .
-
Chuck: High-capacity chuck (0.5-10 mm) accepts various stirrer shaft diameters; through-shaft design allows vertical positioning adjustment; self-locking chuck for quick shaft attachment .
-
Portability: Compact footprint (83 × 220 × 186 mm) and moderate weight (2.8 kg) for easy benchtop placement .
-
Maintenance: Brushless DC motor requires no routine maintenance; chuck and shaft should be cleaned after each use .
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards .
-
Safety Features: Overload protection (LED indicator lights, motor automatically stops in case of continuous overload), anti-spill slow-start mechanism (microprocessor-controlled smooth acceleration), IP42 splash-resistant housing, automatic motor stop in case of anti-stall or overload condition .
-
Electrical Safety: Universal voltage (100-240V, 50/60Hz) for international use; 130W power consumption; earthed power connection recommended .
-
Motor Type: Brushless DC motor provides maintenance-free, quiet, stable operation with long service life and explosion-proof design .
-
Operating Conditions: 5-40°C ambient temperature; ≤80% relative humidity; IP42-rated for splash protection .
-
Standard Accessory: Propeller stirrer (18900071) included .
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store on clean, dry benchtop; protect from dust and moisture; store stirrer shafts separately when not in use .
-
Cleaning: Wipe drive unit housing with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface disinfection; clean chuck and shaft after each use; do not immerse drive unit in liquid; disconnect power before cleaning .
-
Inspection: Inspect power cord for damage before each use; check chuck for wear or debris; verify shaft is securely tightened before operation; inspect stand stability before mounting .
-
Operation: Mount drive unit on appropriate stand (sold separately); select appropriate stirrer shaft for sample viscosity and volume; attach shaft to chuck and tighten securely; immerse impeller into sample (ensure proper depth); set speed using rotary knob; start motor via push-button; monitor LED display for actual speed and overload indicator .
-
Speed Selection: Use lower speeds (50-500 rpm) for gentle mixing, delicate samples, and high-viscosity materials; use medium speeds (500-1200 rpm) for general mixing and suspensions; use higher speeds (1200-2200 rpm) for high shear and emulsification .
-
Shaft Selection: Use propeller-style impellers for general mixing and fluid circulation; use anchor-style impellers for high-viscosity samples; use flat-blade impellers for shear-sensitive applications; use PTFE-coated impellers for corrosive samples; straight propeller, cross blades, paddle, centrifuge style, stainless steel, and PTFE options available .
-
Stand Use: Ensure stand is properly assembled on stable benchtop; verify clamp is securely tightened; ensure drive unit is level and stable before operation .
-
Spill Management: If liquid spills onto drive unit, disconnect power immediately, clean thoroughly with appropriate disinfectant, allow to dry before reuse; IP42 rating provides splash protection but unit should not be submerged .
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: High-torque, high-viscosity (up to 50,000 mPa·s) and large-volume (up to 40L) mixing, homogenizing, suspending, and emulsifying of pharmaceutical formulations, clinical samples, chemical reactions, and quality control samples in high-demand clinical diagnostic, pharmaceutical, and research laboratories .
-
Clinical Role: Essential high-performance mixing equipment in pharmaceutical QC laboratories, clinical chemistry laboratories, biopharmaceutical manufacturing, analytical chemistry labs, and research facilities requiring high-torque or high-viscosity sample preparation .
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Electrical Safety: Disconnect power before cleaning or changing shafts; do not immerse drive unit in liquid; keep power cord away from heat sources and sharp edges; use only properly grounded electrical outlets .
-
Stand Stability: Ensure stand is placed on stable, level surface; verify that clamp is securely tightened; ensure drive unit is properly mounted before operation .
-
Shaft Security: Ensure stirrer shaft is fully inserted and securely tightened in chuck before starting motor; loose shafts may detach during operation and cause injury or sample loss; self-locking chuck provides quick, secure attachment .
-
Sample Container: Use appropriate container (beaker, vessel) with sufficient diameter and depth for impeller; clamp container to stand to prevent spinning or tipping; ensure container can withstand torque of high-viscosity mixing .
-
Operating Precautions: Never operate stirrer with impeller out of liquid; this may damage the motor and sample. Ensure impeller is fully immersed (but not touching container bottom) before starting motor. Do not operate above rated viscosity (50,000 mPa·s) or above rated torque (60 N·cm) .
-
Personal Protective Equipment: Wear appropriate PPE—laboratory coat, safety glasses/face shield, gloves—when operating stirrer; use chemical-resistant gloves when handling corrosive or hazardous materials .
-
Noise Exposure: At ≤70 dB, noise level is below occupational exposure limits; no hearing protection required .
-
Cleaning: Clean spills immediately; disinfect chuck and shaft if biological materials are involved; allow to dry before storage .
-
Overload Response: If overload protection activates (LED indicator lights, motor automatically stops), disconnect power, reduce sample viscosity or volume, or use larger impeller; allow unit to cool before restarting; contact service if issue persists .
-
Training: Only trained laboratory personnel should operate the LED Overhead Stirrer for clinical diagnostic applications .
2. FIRST AID MEASURES
-
Sample Splash: If biological or chemical sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water .
-
Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel .
-
Mechanical Failure: If unit fails to operate, makes abnormal noise, or vibrates excessively, disconnect power, check shaft for balance or damage, contact service if issue persists .
-
Overload Shutdown: If unit stops due to overload, reduce sample viscosity or volume, or use larger impeller; restart after motor cools; contact service if issue persists .
-
Chemical Spill: If corrosive chemicals spill on unit, disconnect power immediately, wipe with appropriate neutralizer, dry thoroughly before reconnecting power .
3. FIRE FIGHTING MEASURES
-
Flammability: Plastic housing and electrical components may burn; brushless DC motor does not produce sparks like carbon brush motors .
-
Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires .
-
Fire Response: Unplug unit immediately; do not use water on electrical fire .
Related products
Cover Glass
$1.00
Cover Glass (coverslips) are thin, transparent glass or plastic squares (e.g., 18×18 mm, 22×22 mm) or rectangles (22×30 mm, 24×50 mm) used to cover specimens on microscope slides for microscopic examination. Available in thickness No. 1 (0.13-0.16 mm) and No. 1.5 (0.16-0.19 mm) for optimal microscopy. Made from optical glass with high light transmission (>90%), refractive index 1.52 matching immersion oil. Packaged in boxes of 100-1000, interleaved with paper to prevent scratching. Primary clinical applications include covering blood films for manual differential counts and malaria diagnosis, wet mount preparations of urine sediment and vaginal secretions, histopathology and cytology slides, Gram-stained bacterial smears, semen analysis, KOH preparations for fungal elements, and India ink preparations for Cryptococcus. Critical safety precautions include handling with forceps (sharp edges), disposing of broken coverslips in sharps containers, avoiding fingerprints on optical surface, and proper disposal of biohazard-contaminated coverslips. Essential consumable in every clinical laboratory performing microscopy.
Finecare Analyzer
$1.00
The Finecare Analyzer is a Class II medical device (FDA-cleared, CE-marked) fluorescence immunoassay system manufactured by Wondfo Biotech for quantitative detection of cardiac markers (troponin I, CK-MB, myoglobin), inflammatory markers (CRP, procalcitonin), thyroid hormones (TSH, FT3, FT4), diabetes markers (HbA1c), reproductive hormones (LH, FSH, prolactin), tumor markers (AFP, CEA, PSA), and infectious disease markers. Features include time-resolved fluorescence technology, color touchscreen interface, built-in printer (select models), USB/Ethernet connectivity, and internal rechargeable battery for portable use. Test time 3-15 minutes, sample volume 50-100 µL (whole blood, serum, plasma). Primary clinical applications include rapid diagnosis of acute myocardial infarction in chest pain patients, early detection of sepsis and bacterial infections, thyroid disorder diagnosis and monitoring, long-term glycemic control assessment in diabetes, fertility and reproductive health evaluation, cancer screening and surveillance, and infectious disease testing in endemic and clinical settings. Critical safety precautions include proper test cartridge storage (2-8°C), regular quality control, biohazard safety protocols, and operator training. Essential point-of-care testing system for hospitals, clinics, and remote healthcare facilities requiring rapid, quantitative results.
Fridge Thermometer
$1.00
A Fridge Thermometer is a precision temperature monitoring device designed for continuous use inside medical and laboratory refrigerators and freezers. Its primary role is to safeguard the potency of vaccines, medications, and biological samples by ensuring storage temperatures remain within a critical specified range (e.g., +2°C to +8°C). Available in analog or digital formats, accurate models with memory functions are essential for compliance with cold chain protocols, requiring daily monitoring, logging, and regular calibration. It is a fundamental quality control tool in pharmacies, clinics, immunization centers, and laboratories.
Mission Plus HB Machine
$1.00
The Mission Plus HB Machine is a portable, battery-operated hemoglobin meter (Class II medical device, FDA-cleared/CE-marked) using photometric technology to measure hemoglobin concentration in capillary or venous blood within 5-15 seconds. Features include backlit LCD display, memory storage for 100-500 results, simple one-button operation, and disposable single-use cuvettes (5-20 µL sample volume). Accuracy ±0.3 g/dL compared to reference methods, measurement range 4-24 g/dL. Primary clinical applications include rapid anemia screening in outpatient clinics, preoperative assessment, antenatal care and maternal health monitoring, malaria-endemic region screening, chronic disease management (CKD, IBD, cancer), nutritional assessment and intervention programs, and blood donor screening. Critical safety precautions include single-use lancets, proper hand hygiene, correct sample application, quality control with control solutions, proper cuvette storage (protect from heat, light, humidity), and never using expired cuvettes. Essential point-of-care device for hemoglobin testing in diverse healthcare settings.
Rheumatoid factor
$1.00
Rheumatoid Factor (RF) testing is a quantitative or semi-quantitative serological assay (nephelometry, turbidimetry, latex agglutination, or ELISA) for detecting autoantibodies against the Fc portion of immunoglobulin G, primarily of the IgM isotype. RF is a key marker in the ACR/EULAR classification criteria for rheumatoid arthritis, with sensitivity 60-80% and specificity 70-90%. Test requires serum samples; results reported in IU/mL (reference <15-20 IU/mL) or titer. Primary clinical applications include diagnosis and classification of rheumatoid arthritis, prognostic assessment (high-titer RF correlates with severe, erosive disease), differential diagnosis of inflammatory arthritis, monitoring disease activity, diagnosis of Sjögren's syndrome, evaluation of mixed cryoglobulinemia (hepatitis C-associated), and assessment of other autoimmune and chronic inflammatory conditions. Critical safety precautions include awareness of false positives (other autoimmune diseases, chronic infections, healthy elderly), false negatives (seronegative RA 20-30%), need for clinical correlation, and anti-CCP antibody testing to improve diagnostic accuracy. Essential test for rheumatology practice, autoimmune disease evaluation, and differential diagnosis of inflammatory arthritis.
Urinalysis strips
$1.00
Urinalysis Strips are Class II medical devices (FDA-cleared) consisting of plastic strips with multiple reagent-impregnated pads for simultaneous semi-quantitative detection of urine analytes including leukocytes, nitrites, urobilinogen, protein, pH, blood, specific gravity, ketones, bilirubin, and glucose. Results read by visual comparison to color chart at specified times (30-120 seconds). Primary clinical applications include routine health screening, urinary tract infection diagnosis, diabetes screening and monitoring, kidney disease assessment (proteinuria), hematuria detection, liver function evaluation, and pregnancy monitoring (preeclampsia screening). Critical safety precautions include proper specimen collection (fresh urine), storage at 15-30°C in original container with desiccant, protection from humidity, reading at exact specified times, awareness of interfering substances (ascorbic acid), and confirmation of abnormal results with quantitative tests. Essential screening tool in primary care, emergency medicine, nephrology, urology, and obstetrics.
Vacutainer (EDTA/PLAIN)
$1.00
Vacutainer (EDTA/PLAIN) is a sterile, evacuated blood collection tube (lavender/purple top) containing EDTA anticoagulant (K2EDTA or K3EDTA, 1.5-2.0 mg/mL blood) for hematology, blood banking, flow cytometry, and molecular diagnostics. Available in draw volumes 2-10 mL, glass or PET plastic, with color-coded stopper and sterile interior. EDTA chelates calcium, preventing coagulation while preserving cellular morphology. Primary clinical applications include complete blood count (CBC) and differential, blood typing and antibody screening (ABO/Rh, Coombs), hemoglobin A1c (HbA1c) testing, flow cytometry and immunophenotyping (CD4 counts), molecular diagnostics and PCR testing, sickle cell screening and hemoglobin electrophoresis, and parasitology (malaria smears). Critical safety precautions include filling to completion (correct blood-to-additive ratio), gentle inversion 8-10 times immediately after collection, never using for chemistry or coagulation testing, and proper disposal as biohazardous waste. Essential collection tube for hematology and immunohematology.
VDRL Test For Syphilis
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties