Multi-Purpose Low Speed Centrifuge (DM0636)
WhatsApp Order
The Multi-Purpose Low Speed Centrifuge (DM0636) is a high-capacity benchtop centrifuge designed for large-volume clinical diagnostic sample processing, blood component separation, urinalysis, molecular biology applications, and industrial laboratory use . Operating at speeds from 300 to 6,000 rpm (up to 4,100 × g) with a maintenance-free brushless DC motor, this centrifuge provides the throughput and versatility needed for high-volume clinical laboratories while maintaining low-speed operation optimal for serum and plasma preparation .
The centrifuge accommodates a wide range of rotors, including swing-out rotors for 4 × 100 mL tubes, fixed-angle rotors for 6 × 50 mL or 30–60 × 2.0 mL tubes, and specialized rotors for microplates and PCR strips . The LCD display allows precise monitoring and adjustment of speed (300-6,000 rpm, increment: 10 rpm) and run time (30 seconds to 99 minutes), with speed/RCF switchover for user convenience . The Pulse key enables instantaneous centrifugation for quick spin-down needs .
For the medical technologist and clinical laboratory scientist, the DM0636 facilitates serum and plasma separation for blood chemistry testing (liver function tests, renal function tests, electrolytes, glucose, lipid profiles), coagulation studies, and routine hematology workflows. It supports urinalysis sediment preparation for microscopic examination, cerebrospinal fluid cell concentration for neurological diagnostic testing, blood bank compatibility testing for transfusion medicine, nucleic acid extraction for molecular diagnostics, and microplate processing for high-throughput screening.
The centrifuge features comprehensive safety protections including door interlock, imbalance protection alarm, over-speed detection, over-temperature detection, and automatic internal diagnosis system . With 9 programmable acceleration and 10 deceleration levels, 9 program memory storage, dynamic balancing for stable operation, and compliance with IEC/EN61010 safety standards, the DM0636 provides reliable, high-throughput performance for routine laboratory workflows supporting patient diagnosis and treatment monitoring .
Categories: LABORATORY EQUIPMENT AND SUPPLIES, Centrifuges and Separators
Tags: Benchtop Clinical Centrifuge, Blood Separation, Clinical Laboratory Equipment, DLAB Centrifuge, DM0636 Multi-Purpose Low Speed Centrifuge, High Capacity Centrifuge, IVD Centrifuge, Low Speed Centrifuge, Serum Separation, Urinalysis
Description
Multi-Purpose Low Speed Centrifuge (DM0636)
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Large-Capacity Blood Component Separation for High-Volume Clinical Diagnostics
-
Primary Use: Provides a high-capacity benchtop low speed centrifuge with a maximum capacity of 4 × 100 mL (swing-out rotor) and options for 6 × 50 mL or 30–60 × 2.0 mL tubes, enabling large-volume separation of whole blood into serum, plasma, and cellular components for diagnostic laboratory analysis .
-
How it helps: For the medical technologist and clinical laboratory scientist, the DM0636 significantly increases sample processing throughput with its large volume capacity—handling up to four 100 mL tubes or multiple blood collection tubes simultaneously, reducing hands-on time, accelerating turnaround for test results, and improving laboratory efficiency in high-volume clinical settings. For the patient, faster high-volume sample processing means receiving diagnostic results more quickly, enabling earlier diagnosis and treatment initiation.
2. Versatile Centrifugation for Multiple Clinical Applications
-
Primary Use: Accepts a wide range of optional rotors (fixed angle and swing-out), including rotors for 100 mL, 50 mL, 15 mL, 2.0 mL tubes, microplates, and PCR strips, supporting diverse applications from routine blood work to specialized research protocols .
-
How it helps: For the laboratory manager, the extensive rotor compatibility eliminates the need for several dedicated centrifuges—allowing a single instrument to handle blood tube processing, urine concentration, plate-based assays, and specialized molecular biology applications. For the patient, versatile equipment ensures that diagnostic testing can be performed efficiently across multiple test types without equipment delays.
3. Serum and Plasma Preparation for Clinical Chemistry
-
Primary Use: Supports serum and plasma preparation for standard blood chemistry panels including liver function tests, renal function tests, electrolytes, glucose, and lipid profiles using standard vacutainer tubes and tube adapters .
-
How it helps: For the clinical chemist, the DM0636’s consistent low speed operation (300-6,000 rpm) with ±20 rpm speed accuracy ensures optimal separation of serum and plasma without hemolysis or cellular damage—improving the accuracy of routine chemistry testing. For the patient, high-quality sample preparation reduces the need for repeat blood draws and ensures reliable diagnostic results for common health screenings.
4. Urinalysis and Body Fluid Sediment Preparation
-
Primary Use: Accommodates urine tubes and conical tubes for urine sediment preparation, as well as cerebrospinal fluid and other body fluid samples for microscopic examination .
-
How it helps: For the clinical laboratory scientist, the DM0636’s low speed, gentle centrifugation preserves cellular morphology while effectively concentrating sediment elements—improving microscopic diagnostic accuracy for urinary tract infections, kidney disease, and neurological conditions. For the patient, accurate sediment preparation supports correct diagnosis of conditions requiring urinalysis and body fluid testing.
SECONDARY & SUPPORTIVE USES
1. Blood Chemistry and Coagulation Testing Preparation: Used for serum and plasma separation for routine blood chemistry analysis and coagulation studies.
2. Lipoprotein and Lipid Panel Analysis: Supports sample preparation for lipid profiling and cholesterol fractionation for cardiovascular risk assessment.
3. Nucleic Acid Extraction and Purification: Used in DNA and RNA extraction protocols for spin column-based purification in molecular diagnostics.
4. PCR Sample Preparation: Supports spin-down of PCR microtubes and PCR strips for molecular testing workflows.
5. Urinalysis Sediment Preparation: Used for concentration of urine sediment for microscopic examination and culture preparation.
6. Cerebrospinal Fluid (CSF) Processing: Used for cell concentration and sediment preparation for CSF analysis in neurology diagnostics.
7. Pleural, Peritoneal, and Synovial Fluid Analysis: Supports cell concentration and sediment preparation for body fluid cytology and chemistry.
8. Blood Bank and Transfusion Medicine: Used for cross-matching, antibody screening, and blood component preparation.
9. Quality Control Sample Preparation: Supports preparation of QC samples for clinical laboratory quality assurance programs.
10. Aliquot Preparation: Used for preparing sample aliquots for secondary testing, storage, and reference laboratory send-outs.
11. Microplate and Deep-Well Plate Processing: Supports centrifugation of 96-well microplates and deep-well plates for high-throughput screening and sample preparation.
12. Cell Culture and Tissue Homogenate Processing: Used for pelleting cells from culture media and removing cellular debris from tissue homogenates.
13. Basic Research and Academic Laboratories: Used in university and research laboratory settings for routine centrifugation needs.
14. Veterinary Diagnostic Laboratory: Supports sample processing for animal health testing and veterinary diagnostics.
15. Environmental and Food Testing: Used in water quality and food safety laboratories for the separation of particulates from liquid samples.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A large-capacity, multi-purpose benchtop low speed centrifuge designed for clinical diagnostic sample processing, blood component separation, urinalysis, molecular biology applications, and industrial laboratory use .
-
Designation: DM0636 Multi-Purpose Low Speed Centrifuge, Low Speed Centrifuge, High Capacity Centrifuge, Benchtop Clinical Centrifuge, Multi-Purpose Centrifuge, DLAB DM0636, Laboratory Centrifuge .
-
Key Components:
-
Multiple Rotor Options: Fixed-angle and swing-out rotors for diverse tube types (100 mL, 50 mL, 15 mL, 2.0 mL, PCR strips) .
-
Motor: Maintenance-free brushless DC motor .
-
Display: LCD display for speed (RPM) and Relative Centrifugal Force (RCF/xg) monitoring .
-
Control: User-friendly interface with programmable memory .
-
Safety Features: Door interlock, imbalance protection, over-speed detection, over-temperature detection .
-
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Maximum Speed: 6,000 rpm (300 – 6,000 rpm, increment: 10 rpm) .
-
Maximum RCF (Relative Centrifugal Force): 4,100 × g (increment: 10 × g) .
-
Speed Accuracy: ±20 rpm .
-
Rotor Capacity (Maximum): 4 × 100 mL (swing-out rotor); 6 × 50 mL (angle rotor); 30 × 2.0 mL / 60 × 2.0 mL (angle rotor) .
-
Run Time: 30 seconds – 99 minutes; HOLD (continuous running) .
-
Program Memory Storage: 9 program storage capacity .
-
Acceleration/Deceleration Levels: 9 acceleration steps / 10 deceleration steps .
-
Motor Type: Maintenance-free brushless DC motor .
-
Noise Level: ≤ 65 dB .
-
Power Requirements: 220-240V, 50Hz/60Hz, 6.3A; 110-120V, 50Hz/60Hz,10A; 660W .
-
Dimensions (L × W × H): 570 × 445 × 295 mm .
-
Weight: 36 kg .
-
Certifications: CE, cTÜVus, FCC, IVD .
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: High-strength materials with excellent dynamic balancing for quiet, stable operation at high capacity .
-
Control: LCD display with user-friendly interface; speed/RCF switchover function; Pulse key for quick spin .
-
Quick Spin Function: Pulse key allows instantaneous centrifugation for quick sample processing .
-
Operation Modes: Timed operation (30 sec-99 min) and continuous (HOLD) operation .
-
Rotor Exchange: Tool-free rotor identification and easy rotor change for quick switching between applications .
-
Rotor Identification: Automatic rotor identification for safety and performance optimization .
-
Portability: Benchtop design with compact footprint suitable for routine laboratory use.
-
Maintenance: Brushless DC motor eliminates routine brush replacement .
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: Class II medical device for clinical diagnostic use; compliant with In Vitro Diagnostic (IVD) medical equipment requirements .
-
Safety Certifications: CE certified; cTÜVus certified; FCC certified .
-
Safety Features: Door interlock system (prevents operation with lid open), imbalance protection alarm, over-speed detection, over-temperature detection, automatic internal diagnosis system .
-
Electrical Safety: Over-temperature protection; wide voltage tolerance (110-240V) for international use .
-
Noise Control: Low noise operation (≤65 dB) for comfortable laboratory environment .
-
Compliance: Complies with IEC 61010-1, IEC 61010-2-020, and EN 61010-1/2-020 safety standards .
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store on clean, dry benchtop; ensure adequate clearance for ventilation; ambient temperature 2–40°C, relative humidity ≤80% .
-
Cleaning: Wipe exterior with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for sterilization; do not pour water directly into rotor chamber .
-
Rotor Maintenance: Remove and clean rotors with mild detergent; dry thoroughly before reinstallation; inspect rotor seal rings regularly .
-
Inspection: Inspect rotors for corrosion or scratches before each use; do not use damaged rotors .
-
Power Cord: Inspect power cord for damage before each use.
-
Transport: Remove rotor before moving the centrifuge .
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: High-capacity, low-speed multipurpose sample processing for blood chemistry, coagulation testing, urinalysis, nucleic acid extraction, microplate processing, and general laboratory workflows in clinical diagnostic and research settings .
-
Clinical Role: Essential sample preparation equipment in clinical diagnostic laboratories, hospital laboratories, physician office laboratories, blood banks, molecular diagnostics labs, research laboratories, and industrial quality control facilities.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Rotor Balancing: Ensure rotor is balanced with tubes of equal weight; imbalance may cause excessive vibration and trigger automatic imbalance protection alarm .
-
Lid Security: Ensure lid is securely closed before operation; door interlock prevents operation with open lid .
-
Rotor Inspection: Inspect rotors for cracks, corrosion, or damage before each use; do not use damaged rotors .
-
Tube Compatibility: Use only tubes rated for centrifugation at maximum speed (6,000 rpm) and capacity .
-
Rotor Loading: Load tubes symmetrically; never run rotor with unbalanced loads .
-
Cleaning: Clean spills immediately; disinfect rotor chamber if biological materials are involved; do not pour water directly into rotor chamber .
-
Placement: Place on firm, flat, level surface; ensure the four feet stand firmly on the table; avoid vibration and airflow around the instrument .
-
Training: Only trained laboratory personnel should operate the centrifuge.
2. FIRST AID MEASURES
-
Tube Breakage: If tube breaks during operation, stop centrifuge immediately, allow rotor to stop fully, carefully remove fragments using forceps, disinfect rotor and chamber.
-
Sample Splash: If biological sample splashes, disinfect area immediately with appropriate disinfectant (e.g., 70% ethanol, bleach solution).
-
Imbalance Shutdown: If imbalance shutdown occurs, rebalance rotor equally, restart centrifuge.
-
Power Failure: If power fails during operation, allow rotor to stop naturally before opening lid.
3. FIRE FIGHTING MEASURES
-
Flammability: Plastic and electronic components may burn.
-
Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for electrical fires.
-
Fire Response: Unplug centrifuge immediately; do not use water on electrical fire.
Related products
Anti-Streptol Olysin O Titer (ASOT)
$24.23
Anti-Streptol Olysin O Titer (ASOT) is a quantitative or semi-quantitative serological test (latex agglutination, turbidimetry, nephelometry, or ELISA) for detecting antibodies against streptolysin O, an exotoxin produced by Group A Streptococcus. Elevated or rising titers indicate recent streptococcal infection and are essential for diagnosing post-streptococcal sequelae including acute rheumatic fever (Jones criteria) and post-streptococcal glomerulonephritis. The test requires serum samples; acute and convalescent (2-4 weeks apart) with fourfold rise confirms recent infection. Reference range typically <200-250 Todd units/mL (adults), varies by age and population. Primary clinical applications include diagnosis of Group A streptococcal infections, acute rheumatic fever evaluation, post-streptococcal glomerulonephritis diagnosis, differentiation of acute vs. past infection, evaluation of unexplained arthritis or carditis, pediatric inflammatory conditions (PANDAS), and monitoring disease activity in rheumatic fever. Critical safety precautions include proper timing of acute and convalescent samples, awareness of false negatives/positives, clinical correlation for diagnosis, and standard biohazard precautions. Essential test for rheumatology, nephrology, cardiology, and infectious disease practice.
Binocular Microscope
$1.00
A Binocular Microscope is a high-precision, compound optical instrument fundamental to clinical diagnostics. Featuring dual eyepieces for comfortable viewing and a suite of parfocal objective lenses (4x, 10x, 40x, 100x oil), it provides magnifications from 40x to 1000x. Its integrated LED illumination, mechanical stage, and Abbe condenser enable the detailed examination of stained blood films, tissue sections, microbiological specimens, and cytological preparations. As the primary tool for pathologists and laboratory scientists, it is indispensable for definitive diagnoses in hematology, histopathology, microbiology, and urinalysis, demanding skilled operation and meticulous maintenance for optimal performance.
Brucella Set
$1.00
A Brucella Set is a comprehensive serological test system (Class II medical device, CE-marked/FDA-cleared) for qualitative and quantitative detection of antibodies against Brucella species (B. abortus, B. melitensis, B. suis, B. canis) using multiple methodologies including tube agglutination, slide agglutination, and 2-mercaptoethanol (2-ME) testing. The set includes killed, stained Brucella antigens, positive and negative controls, dilution tubes, reaction cards, and 2-ME reagent for IgM/IgG differentiation. Diagnostic titer ≥1:160 or fourfold rise confirms brucellosis. Primary clinical applications include diagnosis of brucellosis in endemic regions (undulant fever, night sweats, arthralgia), fever of unknown origin investigation, occupational health screening in high-risk workers (veterinarians, farmers, slaughterhouse workers), diagnosis of focal complications (sacroiliitis, spondylitis, meningitis, endocarditis), treatment monitoring (fourfold decline indicates response), outbreak investigation, and public health surveillance. Critical safety precautions include handling all samples in biosafety cabinet (Brucella is highly infectious via aerosol), 2-ME reagent toxicity (use fume hood), awareness of prozone phenomenon (serial dilutions essential), cross-reactions with other Gram-negative bacteria, and mandatory reporting to public health authorities. Essential test for brucellosis diagnosis in endemic regions and occupational health settings.
Electric Centrifuge
$1.00
An Electric Centrifuge is a Class I medical device that uses rapid rotation to separate fluids of different densities, essential in clinical laboratories for processing blood, urine, and other biological specimens. Available in benchtop, refrigerated, microcentrifuge, hematocrit, and high-speed models with fixed-angle, swinging-bucket, or vertical rotors. Speed range 1,000-30,000+ RPM with RCF up to 65,000+ x g. Features include brushless induction motor, digital controls, imbalance detection, lid lock safety, and programmable protocols. Primary clinical applications include separation of serum/plasma for chemistry and hematology testing, urine sediment analysis for microscopy, platelet-rich plasma (PRP) preparation for regenerative medicine, concentration of bacteria for microbiology, cytology fluid analysis, blood banking, and molecular biology sample processing. Critical safety precautions include proper balancing of loads (weight matching), use of sealed rotors for biohazardous samples, regular rotor inspection for corrosion or cracks, never exceeding maximum rated speed, and never opening lid during operation. Essential equipment in clinical, research, and teaching laboratories.
H.pylori test kits (Antigen)
$1.00
H.pylori test kits (Antigen) are Class II medical devices (FDA-cleared/CE-marked) for rapid immunochromatographic or enzyme immunoassay detection of Helicobacter pylori antigens in stool specimens, enabling non-invasive diagnosis of active infection and post-treatment eradication confirmation. Test principles use monoclonal or polyclonal antibodies specific to H. pylori antigens, producing visible results in 10-20 minutes (rapid tests) or 1-2 hours (EIA). Sensitivity 90-98%, specificity 92-99% compared to gold standard methods. Primary clinical applications include rapid diagnosis of H. pylori infection in patients with dyspepsia, initial screening in uncomplicated dyspepsia (test-and-treat strategy), confirmation of active infection before therapy, post-treatment eradication confirmation (4-6 weeks after therapy), pediatric testing (preferred non-invasive method), screening in high-risk populations (family history of gastric cancer), and monitoring in patients with peptic ulcer disease or MALT lymphoma. Critical safety precautions include mandatory washout period (4 weeks off antibiotics, 2 weeks off PPIs) to avoid false negatives, proper specimen handling (universal precautions), refrigerated storage of kits (2-30°C), quality control verification, and disposal as biohazardous waste. Essential non-invasive tool for H. pylori management in gastroenterology and primary care.
Microscope Bulb
$1.00
A Microscope Bulb is a specialized halogen or LED lamp that serves as the essential illumination source for clinical and laboratory microscopes. Providing the bright, stable, and color-corrected light required for diagnostic visualization of specimens, it is a critical consumable component. Its technical specifications—voltage, wattage, base type, and filament alignment—must precisely match the microscope model. Proper handling (using gloves to avoid oil contamination) and adherence to safety protocols (allowing cooling, disconnecting power) are crucial for safe replacement and optimal bulb lifespan. Maintaining spares is vital to prevent operational downtime in diagnostic laboratories.
Rota virus
$1.00
Rota virus rapid tests are immunochromatographic assays (CE-marked, FDA-cleared for some brands) for qualitative detection of rotavirus group A antigens in stool specimens, providing results in 10-20 minutes. The test principle uses monoclonal or polyclonal antibodies against rotavirus antigens (typically VP6 protein) immobilized on membranes, capturing antigens that form a visible line. Sensitivity 90-98%, specificity 95-99% compared to ELISA or PCR. The kit includes individually foil-wrapped test devices, sample diluent, and collection applicators. Primary clinical applications include rapid diagnosis of acute gastroenteritis in children (rotavirus is the leading cause of severe diarrhea in under-5 children), outbreak investigation in daycare centers and schools, hospital infection control and isolation precautions, differential diagnosis of acute diarrhea (viral vs. bacterial vs. parasitic), vaccine effectiveness monitoring and surveillance, assessment of dehydration risk, and evaluation of immunocompromised patients. Critical safety precautions include proper specimen collection (clean container, avoid contamination), biological hazard precautions (all stool potentially infectious), quality control verification, and awareness that a negative test does not rule out other causes of gastroenteritis. Essential tool for pediatric gastroenteritis management, infection control, and public health surveillance.
VDRL Test For Syphilis
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties