Low Speed Centrifuge (DM0612)
WhatsApp Order
The Low Speed Centrifuge (DM0612) is a benchtop centrifuge designed for clinical diagnostic sample processing, blood component separation, urinalysis, and general laboratory applications. With a rotor capacity of 12 × 15 mL tubes, this centrifuge provides the throughput needed for moderate-volume clinical laboratories while maintaining low-speed operation optimal for serum and plasma preparation.
For the medical technologist and clinical laboratory scientist, the DM0612 facilitates serum and plasma separation for blood chemistry testing (liver function tests, renal function tests, electrolytes, glucose, lipid profiles), coagulation studies (PT, PTT), and routine hematology workflows. It supports urinalysis sediment preparation for microscopic examination, cerebrospinal fluid cell concentration for neurological diagnostic testing, blood bank compatibility testing for transfusion medicine, and nucleic acid extraction for molecular diagnostics.
The centrifuge features a maintenance-free brushless DC motor, simple interface for speed and time adjustment, and essential safety features including door interlock and imbalance detection. Tube adaptors allow processing of various tube sizes including 10 mL, 7 mL, and 5 mL vacutainer tubes, as well as 1.5-2 mL microcentrifuge tubes.
Safety features include door interlock and imbalance detection, with CE safety certification. The DM0612 provides reliable, consistent performance for routine laboratory workflows supporting patient diagnosis and treatment monitoring.
Description
Low Speed Centrifuge (DM0612)
PRIMARY CLINICAL & DIAGNOSTIC USES
1. High-Capacity Blood Component Separation for Clinical Diagnostics
-
Primary Use: Provides a benchtop low-speed centrifuge with a maximum capacity of 12 × 15 mL tubes, enabling efficient separation of whole blood into serum, plasma, and cellular components for diagnostic laboratory analysis.
-
How it helps: For the medical technologist and clinical laboratory scientist, the DM0612 handles up to 12 standard 15 mL centrifuge tubes or vacutainer blood collection tubes simultaneously—reducing hands-on time, accelerating turnaround for test results, and improving laboratory efficiency in moderate-volume clinical settings. For the patient, faster sample processing means receiving diagnostic results more quickly, enabling earlier diagnosis and treatment initiation.
2. Serum and Plasma Preparation for Clinical Chemistry
-
Primary Use: Supports serum and plasma preparation for standard blood chemistry panels including liver function tests, renal function tests, electrolytes, glucose, and lipid profiles using standard vacutainer tubes.
-
How it helps: For the clinical chemist, the DM0612’s consistent low-speed operation ensures optimal separation of serum and plasma without hemolysis or cellular damage—improving the accuracy of routine chemistry testing. For the patient, high-quality sample preparation reduces the need for repeat blood draws and ensures reliable diagnostic results for common health screenings.
3. Urinalysis and Body Fluid Sediment Preparation
-
Primary Use: Accommodates 15 mL conical tubes for urine sediment preparation, as well as cerebrospinal fluid and other body fluid samples for microscopic examination.
-
How it helps: For the clinical laboratory scientist, the DM0612’s low-speed, gentle centrifugation preserves cellular morphology while effectively concentrating sediment elements—improving microscopic diagnostic accuracy for urinary tract infections, kidney disease, and neurological conditions. For the patient, accurate sediment preparation supports correct diagnosis of conditions requiring urinalysis and body fluid testing.
4. General Laboratory Sample Processing
-
Primary Use: Provides essential sample preparation for routine clinical laboratory workflows including coagulation testing, blood bank compatibility testing, and basic research applications requiring low-speed centrifugation.
-
How it helps: For the laboratory manager, the DM0612 serves as a reliable workhorse centrifuge for daily clinical operations—handling blood collection tubes, coagulation tubes, and other standard laboratory tubes with consistent, dependable performance. For the patient, efficient sample processing supports timely diagnosis and treatment across multiple clinical departments.
SECONDARY & SUPPORTIVE USES
1. Blood Chemistry and Coagulation Testing Preparation: Used for serum and plasma separation for routine blood chemistry analysis and coagulation studies (PT, PTT).
2. Lipoprotein and Lipid Panel Analysis: Supports sample preparation for lipid profiling and cholesterol fractionation for cardiovascular risk assessment.
3. Nucleic Acid Extraction and Purification: Used in DNA and RNA extraction protocols for spin column-based purification in molecular diagnostics.
4. PCR Sample Preparation: Supports spin-down of PCR microtubes and PCR strips for molecular testing workflows.
5. Urinalysis Sediment Preparation: Used for concentration of urine sediment for microscopic examination and culture preparation.
6. Cerebrospinal Fluid (CSF) Processing: Used for cell concentration and sediment preparation for CSF analysis in neurology diagnostics.
7. Pleural, Peritoneal, and Synovial Fluid Analysis: Supports cell concentration and sediment preparation for body fluid cytology and chemistry.
8. Blood Bank and Transfusion Medicine: Used for cross-matching, antibody screening, and blood component preparation.
9. Quality Control Sample Preparation: Supports preparation of QC samples for clinical laboratory quality assurance programs.
10. Aliquot Preparation: Used for preparing sample aliquots for secondary testing, storage, and reference laboratory send-outs.
11. Basic Research and Academic Laboratories: Used in educational and research settings for routine centrifugation needs.
12. Veterinary Diagnostic Laboratory: Supports sample processing for animal health testing and veterinary diagnostics.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A benchtop low-speed centrifuge with 12 × 15 mL tube capacity, designed for clinical diagnostic sample processing, blood component separation, and general laboratory applications.
-
Designation: DM0612 Low Speed Centrifuge, Clinical Centrifuge, Benchtop Centrifuge, Low Speed Centrifuge, DLAB DM0612, Laboratory Centrifuge.
-
Key Components:
-
Fixed-Angle Rotor: 12 × 15 mL tube capacity (including 15 mL conical tubes and vacutainer tubes).
-
Tube Adaptors: Adaptors for smaller tube sizes (e.g., 10 mL, 7 mL, 5 mL vacutainers).
-
Motor: Maintenance-free brushless DC motor.
-
Display: Speed (RPM) and RCF (xg) display.
-
Safety Features: Lid interlock, imbalance detection.
-
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Maximum Speed: 2,500 – 4,000 rpm (typical low speed range).
-
Maximum RCF (Relative Centrifugal Force): Up to 1,800 – 2,200 × g.
-
Rotor Capacity: 12 × 15 mL tubes (with adaptors for 10 mL, 7 mL, 5 mL, and 1.5-2 mL tubes).
-
Run Time: Timed operation (1-99 minutes) and continuous (HOLD) operation.
-
Motor Type: Maintenance-free brushless DC motor.
-
Noise Level: ≤ 55 dB.
-
Power Requirements: 110-240V, 50/60Hz.
-
Dimensions (L × W × H): Compact benchtop footprint.
-
Weight: Moderate weight for benchtop stability.
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: High-strength rotor material with dynamic balancing for quiet, stable operation.
-
Control: Simple interface for speed and time adjustment.
-
Operation Modes: Timed operation and continuous (HOLD) operation.
-
Rotor Exchange: Fixed-angle rotor design; limited exchange capability.
-
Lid Operation: Manual or automatic lid-lock release.
-
Safety Features: Door safety interlock, imbalance detection.
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: Class II medical device for clinical diagnostic use.
-
Safety Certifications: CE certified.
-
Safety Features: Door interlock system, imbalance detection alarm.
-
Electrical Safety: Wide voltage tolerance (110-240V) for international use.
-
Noise Control: Low noise operation for comfortable laboratory environment.
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store on clean, dry benchtop; ensure adequate clearance for ventilation.
-
Cleaning: Wipe exterior with soft, damp cloth; use mild detergent if needed.
-
Rotor Maintenance: Remove and clean rotor with mild detergent; dry thoroughly before reinstallation.
-
Inspection: Inspect rotor for cracks or damage before each use; replace if compromised.
-
Power Cord: Inspect power cord for damage before each use.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Low-speed sample processing for blood chemistry, coagulation testing, urinalysis, nucleic acid extraction, and general laboratory workflows in clinical diagnostic and research settings.
-
Clinical Role: Essential sample preparation equipment in clinical diagnostic laboratories, hospital laboratories, physician office laboratories, blood banks, and molecular diagnostics labs.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Rotor Balancing: Ensure rotor is balanced with tubes of equal weight; imbalance may cause excessive vibration.
-
Lid Security: Ensure lid is securely closed before operation; lid interlock prevents operation with open lid.
-
Rotor Inspection: Inspect rotor for cracks or damage before each use; do not use damaged rotors.
-
Tube Compatibility: Use only tubes rated for low-speed centrifugation.
-
Rotor Loading: Load tubes symmetrically; never run rotor with unbalanced loads.
-
Cleaning: Clean spills immediately; disinfect rotor chamber if biological materials are involved.
-
Placement: Place on stable, level surface; ensure adequate ventilation.
-
Training: Only trained laboratory personnel should operate the centrifuge.
2. FIRST AID MEASURES
-
Tube Breakage: If tube breaks during operation, stop centrifuge immediately, allow rotor to stop fully, carefully remove fragments using forceps, disinfect rotor and chamber.
-
Sample Splash: If biological sample splashes, disinfect area immediately with appropriate disinfectant.
-
Imbalance Shutdown: If imbalance shutdown occurs, rebalance rotor equally, restart centrifuge.
3. FIRE FIGHTING MEASURES
-
Flammability: Plastic and electronic components may burn.
-
Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for electrical fires.
-
Fire Response: Unplug centrifuge immediately; do not use water on electrical fire.
Related products
Centrifuge Tubes
$1.00
Centrifuge Tubes are specialized disposable containers (polypropylene) designed to withstand high centrifugal forces (up to 30,000 x g) for separating biological fluids based on density. Available in microcentrifuge sizes (0.2-2.0 mL), conical tubes (15 mL, 50 mL), and larger volumes (100-500 mL). Features include leak-proof screw caps with O-rings (conical tubes), snap caps (microcentrifuge tubes), graduated volume markings, writing areas, and sterile/non-sterile options. Certified RNase/DNase-free, pyrogen-free, and autoclavable. Primary clinical applications include blood component separation (serum/plasma), urine sediment preparation, microbiology sample concentration, molecular biology (DNA/RNA extraction), cell culture processing, protein/enzyme analysis, and viral load testing. Critical safety precautions include never exceeding maximum RCF rating, proper balancing by weight, secure cap tightening, inspection for cracks, and disposal as biohazardous waste. Essential consumable in every clinical, research, and industrial laboratory.
Coagulation Analyzer
$1.00
A Coagulation Analyzer is a compact, automated instrument designed for performing essential tests that evaluate the blood's clotting ability. It accurately measures key parameters such as Prothrombin Time (PT/INR), Activated Partial Thromboplastin Time (aPTT), Thrombin Time, and Fibrinogen, which are critical for monitoring anticoagulant therapy (warfarin, heparin), diagnosing bleeding disorders, and assessing surgical risk. With its photometric detection and user-friendly operation, it delivers reliable results for small to medium-volume laboratories, clinics, and hospital wards. Its role in ensuring safe and effective patient management in thrombosis and hemostasis makes it a vital tool in clinical diagnostics.
CRP Test Kit
$1.00
CRP Test Kit (C-Reactive Protein) is a quantitative or semi-quantitative immunoassay (latex agglutination, turbidimetry, nephelometry, ELISA, or rapid immunochromatographic) for detecting C-reactive protein in blood, an acute-phase reactant produced in response to inflammation. Rapid rise within 6-12 hours, peaks at 24-48 hours, half-life 19 hours. Normal <5-10 mg/L; mild elevation 10-100 mg/L (viral infections, autoimmune flares); moderate 100-200 mg/L (bacterial infections); marked >200 mg/L (sepsis, major trauma). High-sensitivity CRP (hs-CRP) detects 0.1-10 mg/L for cardiovascular risk stratification (<1 mg/L low risk, 1-3 mg/L moderate, >3 mg/L high). Primary clinical applications include detection and monitoring of inflammation, diagnosis and management of infections (differentiating bacterial from viral), assessment of autoimmune disease activity, post-surgical monitoring for complications, cardiovascular risk screening (hs-CRP), monitoring rheumatic fever and inflammatory conditions, and neonatal sepsis evaluation. Critical safety precautions include proper sample handling (universal precautions), quality control verification, awareness of non-specific elevation, prozone phenomenon in very high concentrations, and clinical correlation for interpretation. Essential test for evaluating inflammation across all medical specialties.
Electric Centrifuge
$1.00
An Electric Centrifuge is a Class I medical device that uses rapid rotation to separate fluids of different densities, essential in clinical laboratories for processing blood, urine, and other biological specimens. Available in benchtop, refrigerated, microcentrifuge, hematocrit, and high-speed models with fixed-angle, swinging-bucket, or vertical rotors. Speed range 1,000-30,000+ RPM with RCF up to 65,000+ x g. Features include brushless induction motor, digital controls, imbalance detection, lid lock safety, and programmable protocols. Primary clinical applications include separation of serum/plasma for chemistry and hematology testing, urine sediment analysis for microscopy, platelet-rich plasma (PRP) preparation for regenerative medicine, concentration of bacteria for microbiology, cytology fluid analysis, blood banking, and molecular biology sample processing. Critical safety precautions include proper balancing of loads (weight matching), use of sealed rotors for biohazardous samples, regular rotor inspection for corrosion or cracks, never exceeding maximum rated speed, and never opening lid during operation. Essential equipment in clinical, research, and teaching laboratories.
Manual Centrifuge
$1.00
A Manual Centrifuge (hand-powered) is a non-electric mechanical device for separating fluids based on density, designed for use in field clinics, remote health posts, and developing world settings where electricity is unavailable or unreliable. Operated by hand crank, pull-cord, or foot pedal, achieving speeds of 1,000-4,000 RPM and RCF up to 1,500 x g. Accepts standard blood collection tubes (2-5 mL), microhematocrit tubes, and small centrifuge tubes. Primary clinical applications include separation of serum/plasma for basic diagnostic testing, urine sediment concentration for microscopy, microhematocrit determination for anemia screening, concentration of parasites for malaria and other vector-borne disease diagnosis, field epidemiology and outbreak investigation, veterinary medicine in rural settings, and teaching in resource-limited institutions. Critical safety precautions include meticulous balancing of tubes by weight (absolutely essential), never exceeding maximum rated speed, using appropriate PPE (no aerosol containment), regular inspection of gears and rotor for wear, and proper training of operators. Essential equipment for basic laboratory capabilities in low-resource and field settings.
Mission Plus HB Machine
$1.00
The Mission Plus HB Machine is a portable, battery-operated hemoglobin meter (Class II medical device, FDA-cleared/CE-marked) using photometric technology to measure hemoglobin concentration in capillary or venous blood within 5-15 seconds. Features include backlit LCD display, memory storage for 100-500 results, simple one-button operation, and disposable single-use cuvettes (5-20 µL sample volume). Accuracy ±0.3 g/dL compared to reference methods, measurement range 4-24 g/dL. Primary clinical applications include rapid anemia screening in outpatient clinics, preoperative assessment, antenatal care and maternal health monitoring, malaria-endemic region screening, chronic disease management (CKD, IBD, cancer), nutritional assessment and intervention programs, and blood donor screening. Critical safety precautions include single-use lancets, proper hand hygiene, correct sample application, quality control with control solutions, proper cuvette storage (protect from heat, light, humidity), and never using expired cuvettes. Essential point-of-care device for hemoglobin testing in diverse healthcare settings.
Rheumatoid factor
$1.00
Rheumatoid Factor (RF) testing is a quantitative or semi-quantitative serological assay (nephelometry, turbidimetry, latex agglutination, or ELISA) for detecting autoantibodies against the Fc portion of immunoglobulin G, primarily of the IgM isotype. RF is a key marker in the ACR/EULAR classification criteria for rheumatoid arthritis, with sensitivity 60-80% and specificity 70-90%. Test requires serum samples; results reported in IU/mL (reference <15-20 IU/mL) or titer. Primary clinical applications include diagnosis and classification of rheumatoid arthritis, prognostic assessment (high-titer RF correlates with severe, erosive disease), differential diagnosis of inflammatory arthritis, monitoring disease activity, diagnosis of Sjögren's syndrome, evaluation of mixed cryoglobulinemia (hepatitis C-associated), and assessment of other autoimmune and chronic inflammatory conditions. Critical safety precautions include awareness of false positives (other autoimmune diseases, chronic infections, healthy elderly), false negatives (seronegative RA 20-30%), need for clinical correlation, and anti-CCP antibody testing to improve diagnostic accuracy. Essential test for rheumatology practice, autoimmune disease evaluation, and differential diagnosis of inflammatory arthritis.
Salmonella Typhi Test Peratop
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties