Portable Conductivity Meter (DEC1)

WhatsApp Order
The Portable Conductivity Meter (DEC1) is a pocket-sized, single-parameter conductivity tester featuring automatic ranging (0~19.99 mS/cm), multi-color backlit LCD display, automatic temperature compensation (ATC), 1-point automatic calibration, replaceable combined probe design, IP67 dustproof/waterproof rating, and measurement of TDS (0~10.0 g/L), Salinity (0~10 ppt), and Resistivity (50 Ω·cm~20 MΩ·cm) . The DEC1+ variant adds Bluetooth connectivity, mobile APP support, unlimited data storage, graphical display modes (chart, curve, dial), calibration reminders, sample ID management, and timed storage .
For the clinical laboratory scientist, dialysis technician, and water quality specialist, the DEC1 enables rapid, on-site verification of conductivity in purified water systems, dialysis fluids, and pharmaceutical process water—critical parameters for ensuring patient safety during renal replacement therapy and drug manufacturing . The meter is supplied with a hard carrying case, DEC1-S conductivity electrode (pre-installed), 30mL sample vials (2 pieces), 1408 μS/cm and 12.85 mS/cm calibration standards, 4 × AAA batteries, and lanyard .
Key features include multi-color backlit display for easy reading in various lighting conditions , auto data lock when readings stabilize , low battery indicator , user-configurable auto shut-off (1-8 minutes) and backlight duration (5-20 seconds) , and compatibility with CH, USA, and NIST calibration standards . The IP67 rating ensures reliable operation in harsh field environments .
For the patient, accurate conductivity, TDS, and resistivity monitoring of water used in dialysis and pharmaceutical manufacturing ensures that critical treatment fluids meet stringent safety and quality standards—preventing potential harm from improperly treated water and supporting the production of safe, effective medications.
Description

 Portable Conductivity Meter (DEC1)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Water Quality Assessment for Dialysis and Pharmaceutical Applications
  • Primary Use: Provides a pocket-sized, single-parameter conductivity tester with automatic ranging (0~19.99 μS/cm up to 20.0~19.99 mS/cm) and automatic temperature compensation (ATC), designed for rapid assessment of water purity in clinical and pharmaceutical settings .
  • How it helps: For dialysis technicians and water quality specialists, the  Portable Conductivity Meter (DEC1) enables quick verification of conductivity in purified water systems, dialysis fluids, and pharmaceutical process water—critical parameters for ensuring patient safety during renal replacement therapy. The multi-color backlit display ensures easy reading in various lighting conditions, while the IP67 dustproof/waterproof rating allows for use in demanding utility environments . For the patient, accurate conductivity measurement of dialysis water helps prevent adverse events related to improper electrolyte composition, ensuring the safety and efficacy of renal replacement therapy.
2. TDS, Salinity, and Resistivity Measurement for Process Control
  • Primary Use: Measures Total Dissolved Solids (TDS: 0.0 mg/L to 10.0 g/L), Salinity (0~10 ppt), and Resistivity (50 Ω·cm to 20 MΩ·cm) in aqueous samples, providing comprehensive water quality assessment .
  • How it helps: For the pharmaceutical QC chemist and laboratory manager, the DEC1’s ability to measure multiple derived parameters from conductivity allows a single device to assess total ionic content (TDS), salinity levels, and the purity of water (resistivity)—enabling comprehensive water quality monitoring without multiple instruments. The data auto-lock feature ensures stable readings are captured automatically when the measurement stabilizes . For the patient, rigorous monitoring of TDS and resistivity in pharmaceutical water systems ensures that injectable medications and IV solutions meet stringent purity standards.
3. Temperature Measurement for Critical Process Monitoring
  • Primary Use: Integrated temperature sensor measures sample temperature from 0~60 (32~140°F) with accuracy of ±0.2, providing essential thermal data for temperature-sensitive applications .
  • How it helps: For the clinical laboratory scientist and water quality specialist, the built-in thermometer eliminates the need for a separate temperature probe, while the displayed temperature reading confirms that water samples are within acceptable thermal limits for dialysis, pharmaceutical processing, or laboratory use. Automatic temperature compensation (ATC) ensures that conductivity readings are automatically corrected to the reference temperature (typically 25), eliminating calculation errors . For the patient, accurate temperature monitoring ensures that water used in patient treatments is within safe and effective temperature ranges.
4. Portable Field Testing for Environmental and Utility Monitoring
  • Primary Use: Pocket-sized design (IP67 rated) with included carrying case, sample vials, and calibration standards supports field testing of water quality in diverse environments .
  • How it helps: For hospital facility engineers and environmental safety officers, the  Portable Conductivity Meter (DEC1) portable, battery-operated design allows for spot-checking of water quality at various points in hospital water distribution systems, cooling towers, and environmental discharge points. The low battery indicator ensures uninterrupted operation, and the customizable auto shut-off conserves battery life . For the patient and community, consistent monitoring of hospital water systems helps prevent healthcare-associated infections and ensures environmental compliance.

SECONDARY & SUPPORTIVE USES

1. Purified Water System Verification: Used to verify conductivity of purified water, water-for-injection (WFI), and distilled water in hospital and laboratory water treatment systems .
2. Pharmaceutical Process Water Monitoring: Supports validation and routine monitoring of water quality in pharmaceutical manufacturing and cleaning validation protocols.
3. Cooling Tower and Boiler Water Testing: Monitors conductivity and TDS in cooling towers, boiler feed water, and steam generation systems to control blowdown cycles and prevent scale formation .
4. Environmental and Wastewater Monitoring: Measures conductivity of wastewater discharge, surface water, and groundwater in hospital environmental monitoring programs .
5. Aquaculture and Zebrafish Facility Management: Checks conductivity and salinity levels in aquatic animal housing facilities within research institutions .
6. Hydroponic and Agricultural Nutrient Management: Monitors nutrient solution conductivity (EC) in controlled environment agriculture and research plant growth facilities.
7. Food and Beverage Quality Control: Verifies conductivity of process water, cleaning solutions, and product formulations in hospital nutrition services and food safety testing.
8. Educational and Laboratory Training: Serves as a teaching tool for demonstrating conductivity measurement principles in medical technology and clinical laboratory science training programs.
9. Pool and Spa Water Testing: Measures conductivity and TDS in hospital hydrotherapy pools, spas, and aquatic therapy centers to assess water quality.
10. Field and Remote Sample Testing: Pocket-sized design allows for on-site conductivity measurement in diverse locations including patient bedside, field studies, and remote healthcare facilities .
11. Bluetooth Connectivity for Data Management (DEC1+ model): The DEC1+ variant supports Bluetooth connection to mobile APP for bidirectional control, unlimited data storage, graphical data display (chart, table, dial modes), calibration reminders, sample ID management, and timed storage .
12. Multiple Calibration Standards Compatibility: Supports CH, USA, and NIST standard buffer solutions, allowing flexibility for different regional calibration requirements .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A pocket-sized, single-parameter portable conductivity meter with automatic ranging, automatic temperature compensation (ATC), multi-color backlit display, and IP67 dustproof/waterproof rating, designed for rapid water quality assessment in clinical, pharmaceutical, and environmental applications .
  • Designation: DEC1 Portable Conductivity Meter,  Portable Conductivity Meter (DEC1) Pocket Conductivity Tester, DLAB  Portable Conductivity Meter (DEC1), Pocket Conductivity Meter, EC/TDS/Salinity/Resistivity Tester .
  • Key Components:
o Instrument Meter: Pocket-sized housing with multi-color backlit LCD display, IP67 dustproof/waterproof rating, and low battery indicator .
o Conductivity Electrode: Replaceable combined probe design (DEC1-S, pre-installed) with platinum sensing element .
o Calibration Standards: 30mL each of 1408 μS/cm and 12.85 mS/cm conductivity standard solutions (USA series) .
o Sample Vials: 30mL sample vials (2 pieces) for convenient sample collection and testing .
o Power Supply: 4 × 1.5V AAA alkaline batteries (pre-installed) .
o Accessories: Hard carrying case (28.0×23.0×8.2 cm), lanyard, instruction manual .
o Bluetooth Variant (DEC1+): Adds Bluetooth connectivity, mobile APP support, and advanced data management features .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Measurement Parameters: Conductivity (Cond), Total Dissolved Solids (TDS), Salinity (Sal.), Resistivity (Res.), Temperature (/) .
  • Conductivity Measurement Range: 0~19.99 mS/cm, auto-ranging segments: 0~19.99 μS/cm; 20.0~199.9 μS/cm; 200~1999 μS/cm; 2.00~19.99 mS/cm .
  • TDS Range: 0.0 mg/L to 10.0 g/L (TDS coefficient adjustable, default 0.71) .
  • Resistivity Range: 50 Ω·cm to 20 MΩ·cm .
  • Salinity Range: 0~10 ppt .
  • Conductivity Resolution: 0.01/0.1/1 (auto-ranging) .
  • Conductivity Accuracy: ±1.0% F.S. ± 1 digit .
  • Temperature Measurement Range: 0~60 (32~140°F) .
  • Temperature Accuracy: ±0.2 .
  • Calibration Points: 1 point automatic calibration with preset standards .
  • Automatic Temperature Compensation (ATC) Range: 0~99 .
  • Display: Multi-color backlit LCD display; display mode changes color based on measurement status .
  • Data Functions: Reading stability indicator, auto data lock when stable, low battery indicator .
  • Auto Shut-Off: User-configurable (1-8 minutes or OFF) .
  • Backlight Duration: User-configurable (5-20 seconds or OFF) .
  • Protection Class: IP67 (dustproof and waterproof against temporary immersion) .
  • Operating Conditions: 0~60; suitable for field and laboratory use .
  • Power: 4 × AAA alkaline batteries (pre-installed); low voltage indicator .
  • Dimensions (Carrying Case): 28.0 × 23.0 × 8.2 cm .
  • Calibration Standards Supported: CH, USA, NIST standards .
  • Bluetooth Features (DEC1+): Mobile APP connection, bidirectional control, unlimited data storage, graphical display (chart, curve, dial modes),, calibration reminder, sample ID management, timed storage, user-friendly UI .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Pocket-sized, ergonomic handheld design with replaceable combined probe; IP67 dustproof/waterproof rating for field use. 
  • Display: Multi-color backlit LCD display; screen color changes based on measurement status and data stability, providing intuitive user feedback .
  • User Interface: Simple 1-key operation; short press to power on, short press to switch between measurement modes (Cond/TDS/Res/Sal); long press to enter calibration .
  • Calibration: Supports 1 point automatic conductivity calibration; rinse electrode in pure water, submerge in calibration solution (1413 μS/cm or 12.85 mS/cm), wait for stability indicator, press to confirm calibration .
  • Measurement Modes: Short press to toggle between Conductivity (Cond), Resistivity (Res), Total Dissolved Solids (TDS), and Salinity (SAL) .
  • Data Locking: Auto-hold function automatically locks readings when stable; stability indicator (smiley icon) confirms stable measurement; short press to release auto-hold .
  • Replaceable Electrode: Combined probe design allows electrode replacement to suit different applications, extending instrument life .
  • Bluetooth Operation (DEC1+): Connect to mobile APP for enhanced data management; APP provides four display modes (graph, curve, dial, normal); supportsoperation guidance .
  • Portability: Compact pocket-sized design with hard carrying case for safe transport and storage; lanyard included for convenient carrying .
  • Power Management: Low voltage indicator alerts when batteries need replacement; user-configurable auto shut-off (1-8 minutes or OFF) and backlight duration (5-20 seconds or OFF) to conserve battery life .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: In Vitro Diagnostic (IVD) preparatory equipment; laboratory water quality testing instrument.
  • Safety Certifications: Manufactured under ISO 9001:2015 quality management system; CE compliant.
  • Protection Class: IP67 (dustproof and waterproof against temporary immersion up to 1 meter for 30 minutes), suitable for harsh field environments .
  • Electrical Safety: Low-voltage operation with 4 × AAA batteries (1.5V each); safe for use in laboratory and field environments.
  • Material Safety: Plastic housing with replaceable combined probe; platinum sensing element for conductivity measurement; RoHS compliant materials.
  • Calibration Compliance: Supports CH, USA, NIST standard buffer solutions for region-specific calibration requirements .
  • GLP Compliance (DEC1+ with APP): APP supports calibration reminders, sample ID management, timed storage, and unlimited data storage for quality documentation .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store the meter in its hard carrying case in a clean, dry environment. Protect from extreme temperatures and direct sunlight. Remove batteries for long-term storage.
  • Cleaning: Rinse the conductivity electrode with distilled water after each use. Wipe the meter body with a soft, damp cloth using a mild detergent. Do not submerge the meter body beyond the IP67 rating limits. For the platinum sensing element, avoid touching or scrubbing with abrasive materials.
  • Inspection: Inspect the electrode for damage or contamination before each use; check the platinum rod for integrity (any damage or surroundings on the electrode will cause measurement failure) . Verify calibration before critical measurements.
  • Operation: Remove the protective cap; power on by short pressing the power button; select measurement mode (Cond/Res/TDS/SAL) by short pressing the mode button; rinse electrode with distilled water; immerse electrode in sample, stir gently; wait for stability indicator (smiley icon); read stabilized value; auto-hold will lock readings when stable .
  • Calibration: Calibrate before first use or when measurement errors are suspected. Rinse electrode in pure water, submerge in calibration standard (1413 μS/cm or 12.85 mS/cm), shake gently, let stand. Wait for stability indicator, then short press to confirm calibration .
  • Electrode Storage: Store electrode clean and dry with protective cap in place. Do not allow the platinum sensing element to dry with residue; follow manufacturer instructions for long-term storage.
  • Battery Replacement: Replace batteries when low voltage indicator appears; use 4 × AAA alkaline batteries (1.5V each). Ensure correct polarity when installing new batteries .
  • APP Setup (DEC1+): Download the DLAB mobile APP, follow the图文操作指引 to connect via Bluetooth, configure measurement parameters, and enable data storage functions .
  • Spill Management: If liquid spills onto the meter, wipe immediately with a soft, dry cloth; despite IP67 rating, avoid prolonged immersion.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Rapid, portable conductivity, TDS, salinity, and resistivity measurement of purified water, dialysis fluids, pharmaceutical process water, and environmental samples in clinical diagnostic, pharmaceutical, and research settings .
Clinical Role: Essential water quality testing instrument for dialysis units, hospital engineering departments, pharmaceutical quality control laboratories, and environmental monitoring programs requiring rapid on-site conductivity assessment
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Do not immerse the meter beyond the IP67 rating limits; avoid immersion in liquids other than water samples; ensure battery compartment is properly sealed before use.
  • Electrode Handling: The platinum sensing element is delicate; do not touch or scrub with abrasive materials. Inspect the platinum rod before each use for damage .
  • Calibration Verification: Calibrate daily or before critical use using fresh calibration standards (1413 μS/cm or 12.85 mS/cm) appropriate for the expected measurement range .
  • Sample Compatibility: Rinse electrode thoroughly with distilled water between different samples to prevent cross-contamination. Ensure there are no air bubbles trapped on the electrode surface during measurement .
  • Battery Safety: Use only AAA alkaline batteries; do not mix old and new batteries; remove batteries for long-term storage to prevent leakage; dispose of used batteries properly.
  • Environmental Protection: Dispose of calibration standards, sample vials, and other consumables according to local environmental regulations. Calibration solutions contain salts and may be disposed of via standard laboratory waste streams.
  • Storage: Store the meter in its hard carrying case in a clean, dry environment. Protect from extreme temperatures and direct sunlight.
  • Training: Only trained laboratory personnel should operate the DEC1 for water quality testing applications.

2. FIRST AID MEASURES

  • Calibration Standard Exposure: If conductivity calibration standard (1408 μS/cm or 12.85 mS/cm KCl solution) splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
  • Sample Splash: If biological or chemical sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
  • Electrical Malfunction: If the meter shows signs of electrical malfunction (erratic readings, display issues, battery leakage), remove batteries immediately; do not attempt to operate; contact service personnel.
  • Electrode Damage: If the platinum sensing element is damaged, discontinue use; replace the electrode with a new DEC1-S combined probe.

3. FIRE FIGHTING MEASURES

  • Flammability: The plastic housing, cable, and carrying case are combustible; may melt or burn if exposed to flame or high heat.
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for fires involving plastic components.
  • Fire Response: Remove batteries if safe to do so; do not use water on electrical fire; evacuate area if fire cannot be quickly contained.