Portable Conductivity Meter (DEC10-2)

WhatsApp Order
The Portable Conductivity Meter (DEC10-2) is a rugged, high-performance analytical instrument designed for the rigorous demands of water quality monitoring in clinical, pharmaceutical, and industrial environments. This single-parameter meter accurately measures Conductivity, TDS, Salinity, and Resistivity across a wide auto-ranging scale (0~2000.0 mS/cm), featuring a 3.5-inch TFT color screen and IP57 dustproof/waterproof rating [citation:1][citation:2].
For the water quality specialist, the Portable Conductivity Meter (DEC10-2) simplifies critical testing of dialysis water and pharmaceutical purified water loops. It includes the DCON201T 4-ring platinum conductivity cell, which integrates a temperature sensor for automatic temperature compensation (ATC), ensuring accurate readings regardless of sample temperature fluctuations [citation:4]. The meter stores up to 3,000 GLP-compliant data records, complete with timestamps and temperature data, supporting rigorous quality assurance protocols [citation:2].
Supplied with a hard carrying case, calibration standards, Type-C charging cable, and PC software for data export, the Portable Conductivity Meter (DEC10-2) is a comprehensive solution for ensuring the ionic purity of water used in patient treatments and drug manufacturing. For the patient, this rigorous water quality verification helps ensure the safety and efficacy of therapies ranging from kidney dialysis to intravenous medications.
Description

Portable Conductivity Meter (DEC10-2)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Quality Control of Dialysis Water and Purified Water Systems
  • Primary Use: Provides a high-precision, single-parameter portable meter for measuring electrical conductivity (EC), Total Dissolved Solids (TDS), Salinity, and Resistivity across a wide auto-ranging scale, specifically designed for the stringent water quality demands of clinical and pharmaceutical settings [citation:1].
  • How it helps: For dialysis technicians and water quality specialists, the Portable Conductivity Meter (DEC10-2) ensures that purified water and dialysis fluids meet the required ionic purity standards, directly impacting patient safety during renal replacement therapy. A 3.5-inch TFT color screen offers clear visibility of critical parameters, while automatic temperature compensation (ATC) ensures readings are accurate regardless of water temperature fluctuations [citation:2]. For the patient, this precise monitoring helps prevent complications associated with improper dialysate composition, ensuring the treatment is both safe and effective.
2. Pharmaceutical Process Water and Clean-in-Place (CIP) Verification
  • Primary Use: Supports the validation and routine monitoring of Water-for-Injection (WFI) and purified water loops used in pharmaceutical manufacturing, as well as verification of rinse cycles in CIP systems [citation:3].
  • How it helps: For the pharmaceutical QA/QC chemist, the Portable Conductivity Meter (DEC10-2) ability to auto-range from ultra-pure water readings up to high-concentration saline solutions allows a single device to validate water at multiple critical control points. The unit supports GLP-compliant data management by storing up to 3,000 data sets, including timestamps and temperature recordings [citation:2]. For the patient, this data integrity ensures that injectable medications and IV solutions are free from ionic contaminants, upholding product safety and efficacy standards.
3. Industrial Water and Cooling Tower Management
  • Primary Use: Utilized for monitoring conductivity in industrial water treatment, boiler feed water, cooling towers, and environmental discharge to prevent scale formation and ensure regulatory environmental compliance.
  • How it helps: For hospital facility engineers and environmental safety officers, the portable IP57-rated design allows for easy spot-checking of water quality in steam sterilization systems and environmental discharge points. The ability to measure Resistivity (up to 100.0 MΩ·cm) is crucial for diagnosing the health of reverse osmosis membranes used in high-purity loops [citation:1]. For the community, consistent monitoring of hospital wastewater helps prevent environmental contamination and ensures public health protection.

SECONDARY & SUPPORTIVE USES

1. Salinity and TDS Measurement in Research Aquaculture: Monitors salinity levels in zebrafish facilities and research aquariums, ensuring optimal environmental conditions for laboratory animals [citation:4].
2. Hydroponic Nutrient Solution Management: Checks the conductivity (EC) of nutrient solutions in controlled environment agriculture to optimize mineral uptake for test crops [citation:4].
3. Food and Beverage Production Verification: Used to verify the concentration of cleaning solutions and rinse water quality in food processing QA/QC workflows.
4. Educational Laboratory Training: Serves as a teaching tool in clinical laboratory science and chemistry programs to demonstrate the principles of conductometric analysis.
5. Boiler and Steam Generator Diagnostics: Provides rapid assessment of boiler water conductivity to control blowdown cycles and prevent costly corrosion or scaling in hospital steam plants.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A portable, single-parameter benchtop/field meter designed for high-accuracy measurement of conductivity, TDS, salinity, and resistivity with automatic temperature compensation.
  • Designation: DEC10-2 Portable Conductivity Meter, DEC10-2 , DLAB DEC10-2, Single-Parameter Cond Meter [citation:1].
  • Key Components:
    • Instrument Meter: Portable housing with a 3.5-inch TFT LCD color screen, IP57 rating, and Type-C charging [citation:2].
    • Conductivity Electrode: DCON201T 4-ring/platinum epoxy-body sensor with integrated temperature sensor (K=1.0) [citation:4].
    • Accessories: Hard carrying case (330×272×82mm), calibration standards, Type-C cable, lithium battery [citation:3].

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Measurement Modes: Conductivity (Cond), Total Dissolved Solids (TDS), Salinity (Sal.), Resistivity (Res.).
  • Conductivity Range: 0~2000.0 mS/cm, auto-ranging (0~200 mS/cm standard) [citation:1].
  • TDS Range: 0~100.0 g/L.
  • Resistivity Range: 5.000Ω·cm ~ 100.0 MΩ·cm [citation:1].
  • Salinity Range: 0~100 ppt.
  • Conductivity Accuracy: ±0.5% FS ±1 digit.
  • Temperature Range: 0.0~100.0°C (32.0~212.0°F).
  • ATC Range: 0.0~50.0°C.
  • Data Storage: 3000 sets (Value, Temp, Time) [citation:2].
  • Display: 3.5-inch TFT LCD color screen [citation:2].
  • Electrode Constant: K=1.0 cm¹ (DCON201T) [citation:4].

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Rugged, ergonomic design with a durable, chemical-resistant epoxy body for the electrode.
  • User Interface: Intuitive UI with timed measurement, data lock, auto-power off, and brightness adjustment.
  • Calibration: One-point automatic calibration using preset standards; supports manual calibration for specific ranges.
  • Electrode Maintenance: The 4-ring platinum design minimizes polarization, eliminating the need for polishing; requires only regular rinsing and clean storage [citation:4].
  • Portability: Compact hard case and IP57 rating allow for safe transport and use in field or industrial environments [citation:3].
  • Connectivity: Type-C charging (compliant with EU standards) and PC software for data export [citation:2].

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: IVD preparatory equipment; complies with GLP data management standards [citation:2].
  • Protection Class: IP57 (Dustproof and waterproof against temporary immersion).
  • Safety Certifications: CE, ISO 9001:2015; Type-C EU compliance.
  • Electrode Material: Epoxy body (chemical resistant) and platinum sensor (corrosion resistant) [citation:4].

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store meter in a clean, dry place. Electrode should be stored clean and dry to prevent contamination of the platinum surface.
  • Electrode Cleaning: Rinse with distilled water after each use. For stubborn residues (organic or inorganic), use a mild detergent or brief dilute acid soak, followed by thorough rinsing.
  • Handling: Do not touch the platinum black sensor surface; avoid scratching or abrasive cleaning.
  • Calibration Interval: Calibrate daily or before critical use with fresh standards matching the expected measurement range.
  • Data Management: Connect to PC via software to export data for permanent quality records or LIMS integration.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: High-precision water quality assurance in pharmaceutical manufacturing, clinical dialysis centers, and industrial water treatment.
  • Clinical Role: Critical tool for Pharmacy Quality Control, Hospital Engineering (Water Systems), and Dialysis Unit technical staff for verifying water safety and regulatory compliance.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Do not immerse the meter body in liquid (despite IP57 rating).
  • Ensure the electrode is not dry when measuring; the sensing surface must be wetted.
  • Verify there are no air bubbles trapped on the electrode face during measurement, as this will cause unstable readings.