Pro LCD Digital Tube Roller (MX-T6-)

WhatsApp Order
The Pro LCD Digital Tube Roller (MX-T6-) is a 6-roller digital tube roller featuring an LCD display, variable speed control (10-70 rpm), programmable timer (up to 1199 minutes or 99h59min), and a maintenance-free DC brushless motor, designed for gentle, efficient mixing of blood samples, viscous substances, and liquid-solid suspensions in clinical diagnostic and research laboratories .
Key features include a large LCD digital display for real-time monitoring of speed and timer simultaneously, six roller design with 24mm amplitude rocking/rolling motion for thorough yet gentle mixing, dual operating modes (continuous and timed operation), programmable timer with automatic stop and audible alert, integrated drip tray for spill containment, and overload protection with self-diagnostic error display .
The Pro LCD Digital Tube Roller (MX-T6-) accommodates up to 15 x 50 mL centrifuge tubes or 10 x 15 mL centrifuge tubes, with rollers compatible with tubes from 6 to 30 mm in diameter. The cold room and incubator compatibility (5-40°C operating temperature) allows sample mixing under controlled temperature conditions .
For the clinical laboratory scientist and phlebotomist, the Pro LCD Digital Tube Roller (MX-T6-) ensures gentle, thorough mixing of blood samples after collection—preventing clot formation, platelet activation, and hemolysis that could compromise complete blood count (CBC) and coagulation study (PT/PTT) results. For the immunology researcher, it supports immune precipitation protocols and antibody-antigen reaction studies. For the cell biologist, it provides gentle mixing of cell suspensions and culture media while preserving cell viability.
Universal voltage (100-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion, while the compact footprint (445 × 260 × 120 mm) and moderate weight (5.1 kg) allow easy benchtop placement. The IP21 protection rating provides durability against dust and moisture in typical laboratory environments. The 24-month manufacturer’s warranty ensures long-term reliability .
For the patient undergoing coagulation monitoring (warfarin, heparin), complete blood count (CBC), or routine hematology testing, the Pro LCD Digital Tube Roller (MX-T6-) gentle rolling motion, digital precision, and programmable timer ensure accurate test results that guide appropriate treatment decisions—preventing false-negative or false-positive results due to improper sample mixing, clot formation, or platelet activation.
Description

Pro LCD Digital Tube Roller (MX-T6-)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Gentle Rolling Mixing for Blood Coagulation Prevention
  • Primary Use: Provides a 6-roller digital tube roller with LCD display, variable speed control (10-70 rpm), and programmable timer (up to 1199 minutes or 99h59min), designed for gentle, efficient rocking and rolling motion to prevent blood coagulation and immune precipitation in blood samples .
  • How it helps: For the clinical laboratory scientist and phlebotomist, the Pro LCD Digital Tube Roller (MX-T6-) gentle rolling motion (amplitude 24mm) ensures thorough mixing of blood samples without causing hemolysis or activating platelets—critical for preventing clot formation in whole blood samples collected for hematology testing. The digital speed control and LCD display allow precise monitoring of mixing parameters, ensuring reproducible results across operators. For the patient undergoing complete blood count (CBC) or coagulation studies (PT/PTT), proper rolling mixing prevents micro-clot formation that could lead to inaccurate test results, false negatives, and the need for repeat blood draws.
2. LCD Digital Display for Precise Parameter Monitoring
  • Primary Use: Features a large LCD digital display that shows real-time rotation speed (10-70 rpm) and run time, enabling precise monitoring and adjustment of mixing parameters during operation .
  • How it helps: For the clinical laboratory scientist and quality assurance manager, the digital display allows accurate setting and verification of mixing parameters for different sample types and assay protocols—ensuring consistent sample processing across runs and operators, reducing variability, and supporting GLP documentation. For the patient, standardized digital mixing protocols improve diagnostic accuracy and reduce the need for repeat testing due to inconsistent sample preparation.
3. High Capacity for Multiple Tube Sizes
  • Primary Use: Accommodates up to 15 x 50 mL centrifuge tubes and 10 x 15 mL centrifuge tubes simultaneously, with rollers compatible with tubes from 6 to 30 mm in diameter and up to 280 mm in length .
  • How it helps: For the laboratory manager and high-volume testing coordinator, the Pro LCD Digital Tube Roller (MX-T6-) six-roller design and high tube capacity allow batch processing of multiple patient samples—reducing hands-on time, improving workflow efficiency, and ensuring consistent mixing across all samples in a batch. For the patient, batch processing efficiency reduces laboratory turnaround time for routine hematology and coagulation testing, enabling faster clinical decision-making.
4. Dual Operating Modes: Continuous and Timed Operation
  • Primary Use: Supports both continuous operation and programmable timer operation (up to 1199 minutes or 99h59min), with automatic stop at end of set time and audible alert .
  • How it helps: For the clinical laboratory scientist and high-throughput testing coordinator, the programmable timer ensures consistent mixing duration across all samples in a batch—reducing operator-dependent variability and improving workflow efficiency. Continuous mode allows for extended mixing of bulk reagents or when processing multiple sample batches in sequence. For the patient, automated timing reduces the risk of under-mixing or over-mixing that could compromise sample integrity and diagnostic accuracy.
5. DC Brushless Motor for Quiet, Maintenance-Free Operation
  • Primary Use: Utilizes a maintenance-free DC brushless motor providing quiet operation, high stability, and reliable long-term performance .
  • How it helps: For the laboratory manager and clinical laboratory scientist, the brushless DC motor eliminates routine brush replacement, reduces maintenance downtime, and ensures consistent performance over years of daily use—improving laboratory efficiency and reducing total cost of ownership. The quiet operation minimizes distractions in the laboratory environment. For the patient, reliable, consistent mixer performance ensures that sample preparation quality does not degrade over time, supporting reproducible diagnostic results.
6. Cold Room and Incubator Compatibility
  • Primary Use: Designed for use in cold rooms (5-40°C) and incubators (5-40°C, 80% RH), allowing sample mixing under controlled temperature conditions .
  • How it helps: For the clinical laboratory scientist and research technician, the Pro LCD Digital Tube Roller (MX-T6-) wide operating temperature range (5-40°C) and IP21 protection rating allow sample mixing in cold rooms for temperature-sensitive applications, as well as in incubators for cell culture and microbiology workflows. For the patient, temperature-controlled mixing preserves sample integrity for temperature-sensitive assays, supporting accurate diagnostic results for conditions requiring strict temperature control during sample processing.
7. Integrated Drip Tray for Spill Containment
  • Primary Use: Features an integrated drip tray that contains accidental spillages, protecting the work surface and preventing cross-contamination .
  • How it helps: For the clinical laboratory scientist and safety officer, the built-in drip tray contains accidental spills of blood samples, reagents, or other biological materials—reducing contamination risk and simplifying cleanup procedures. For the patient, proper spill containment reduces the risk of cross-contamination between samples and protects laboratory personnel from exposure to potentially infectious materials.
8. Overload Protection and Self-Diagnostic Error Display
  • Primary Use: Equipped with overload protection that automatically shuts down the unit when load exceeds capacity, with LCD display showing error code “Er 03” for overload faults .
  • How it helps: For the laboratory manager and clinical laboratory scientist, the overload protection prevents motor damage from excessive loads, extending equipment lifespan and reducing repair costs. The self-diagnostic error display (LCD showing “Err”) provides immediate visual indication of system faults, enabling rapid troubleshooting . For the patient, reliable equipment operation ensures that sample processing is not interrupted, reducing delays in diagnostic result reporting.

SECONDARY & SUPPORTIVE USES

1. Mixing of Viscous Substances and Liquid-Solid Suspensions: Used for thorough mixing of viscous materials, protein solutions, and liquid-solid suspensions in pharmaceutical and biochemical research .
2. Immune Precipitation and Antibody-Antigen Reactions: Supports gentle rolling mixing for immune precipitation protocols and antibody-antigen reaction studies in immunology research.
3. Cell Suspension and Culture Media Mixing: Used for gentle mixing of cell suspensions, culture media, and biological fluids to preserve cell viability and prevent sedimentation.
4. Enzymatic and Protein Extraction: Supports mixing for enzymatic assays, protein extraction protocols, and biochemical reaction studies requiring gentle, continuous agitation .
5. Biological Fluid Homogenization: Used for homogenization of plasma, serum, and other biological fluids for clinical chemistry and immunoassay preparation.
6. Microbiology Culture Tube Mixing: Supports mixing of bacterial cultures, fungal suspensions, and microbiological samples in tubes for growth and assay preparation.
7. Pharmaceutical Formulation Development: Used for mixing of drug formulations, suspensions, and viscous pharmaceutical preparations during product development.
8. Research and Academic Laboratories: Provides gentle rolling mixing for diverse research applications in cell biology, biochemistry, molecular biology, and biotechnology.
9. Blood Bank and Transfusion Medicine: Supports gentle mixing of blood components, donor blood samples, and reagent red blood cells for compatibility testing.
10. Veterinary Diagnostic Laboratory: Used for mixing of blood, serum, and other biological specimens for animal health testing and infectious disease diagnosis.
11. Environmental and Food Testing Laboratories: Supports mixing of environmental extracts and food samples for microbiological and chemical analysis.
12. Clinical Chemistry and Hematology Sample Preparation: Used for mixing blood samples for complete blood count (CBC), coagulation studies (PT/PTT), and clinical chemistry panels.
13. Pharmaceutical Quality Control: Supports mixing of QC samples and reagents in pharmaceutical testing laboratories.
14. Gentle Dissolution of Solids: Used for gentle dissolution of powdered reagents, crystalline materials, and freeze-dried products into liquid solvents.
15. University and Educational Laboratory Training: Provides versatile mixing for teaching laboratory techniques in undergraduate and graduate science courses.
16. Cold Room Sample Preparation: Compatible with cold room use (5-40°C) for temperature-sensitive sample mixing protocols .
17. Incubator-Compatible Cell Culture: Suitable for use in incubators for cell culture and microbiology applications requiring controlled temperature environments .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A digital tube roller with LCD display, 6-roller design, variable speed control (10-70 rpm), and programmable timer, designed for gentle, efficient mixing of blood samples, viscous substances, and liquid-solid suspensions in clinical diagnostic and research laboratories .
  • Designation: MX-T6-Pro LCD Digital Tube Roller, Digital Tube Roller, LCD Tube Roller, Laboratory Tube Roller, DLAB MX-T6-Pro, SCILOGEX MX-T6-Pro .
  • Key Components:
o Rollers: 6 rollers, each 280 mm in length, 30 mm in diameter, with 24mm amplitude rocking/rolling motion .
o Display: LCD digital display showing speed and timer simultaneously .
o Control Knob: Speed/timer control knob with push-to-start function .
o Mode Switch Button: Shifts between speed and time display/control modes .
o Motor: DC brushless motor (maintenance-free, quiet operation) .
o Drip Tray: Integrated drip tray for spill containment .
o Housing: Impact-resistant plastic body with non-slip base.
o Power Switch: I/O rocker switch with LED power indicator .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Speed Range: 10-70 rpm (variable, adjustable) .
  • Amplitude: 24 mm rocking/rolling motion .
  • Rollers: 6 rollers, 280 mm length, 30 mm diameter, compatible with tubes 6-30mm diameter, up to 280mm length .
  • Tube Capacity: Up to 15 x 50 mL centrifuge tubes or 10 x 15 mL centrifuge tubes .
  • Maximum Load Capacity: 4 kg (9 lbs) .
  • Operating Modes: Continuous operation and timed operation .
  • Timer Range: Up to 1199 minutes (or 99 hours 59 minutes, depending on model) .
  • Motor Type: DC brushless motor (maintenance-free) .
  • Operating Temperature: 5-40°C (cold room and incubator compatible) .
  • Permissible Ambient Humidity: ≤80% RH .
  • Protection Class: IP21 .
  • Power: 30W .
  • Voltage/Frequency: 100-240V, 50/60Hz (universal voltage) .
  • Dimensions (W × D × H): 445 × 260 × 120 mm (approximately 17.5"L x 11"W x 5"H) .
  • Weight: 5.1 kg (approximately 12 lbs) .
  • Compatibility: Compatible with standard centrifuge tubes, blood collection tubes, culture tubes, and small flasks.

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Impact-resistant plastic housing with non-slip base for stable benchtop placement; integrated drip tray for spill containment .
  • Roller Design: 6-roller configuration with 24mm amplitude rocking/rolling motion for gentle, thorough mixing .
  • Display: LCD digital display showing real-time speed (10-70 rpm) and timer simultaneously .
  • Control System: Digital speed control with rotary knob; mode switch button toggles between speed and time display; push knob to start/stop rotation .
  • Timer: Programmable timer (up to 1199 minutes or 99h59min) with automatic stop at end of set time and audible alert .
  • Safety Features: Overload protection (automatic shutdown with "Er 03" error code display), over-current protection, automatic self-check on power-up .
  • Operating Conditions: Can be used in cold rooms (5-40°C) and incubators (5-40°C, 80% RH) .
  • Error Display: LCD displays error codes (e.g., "Er 03" for overload) when system faults occur .
  • Portability: Compact footprint (445 × 260 × 120 mm) and moderate weight (5.1 kg) for easy benchtop placement.
  • Maintenance: DC brushless motor eliminates routine brush replacement; clean with alcohol or mild detergent; wipe with damp cloth .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards; CE certified; FCC Part 15 Class A compliant .
  • Safety Features: Overload protection (automatic shutdown with overload error code "Er 03"), over-current protection, over-voltage protection, automatic self-check on power-up, non-slip base, IP21 protection rating .
  • Electrical Safety: Universal voltage (100-240V, 50/60Hz) for international use; 30W low power consumption; earthed power connection required .
  • Noise Control: Quiet operation (DC brushless motor) minimizes distractions in clinical laboratory settings.
  • GLP Compliance: Digital timer and speed display support GLP documentation; programmable timer allows reproducible mixing protocols.
  • Protection Class: IP21 rating provides protection against solid objects >12mm and vertical dripping water .
  • Warranty: 24-month warranty (2 years) from date of invoice .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture; if not used for long period, switch off and place in dry, clean, room temperature, stable location .
  • Cleaning: Wipe exterior with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; do not use harsh cleansers; disconnect power before cleaning .
  • Inspection: Inspect power cord for damage before each use; check rollers for residue or wear; verify stability of benchtop placement.
  • Operation: Place rotator on safe, stable surface; ensure operating voltage matches power supply; socket must be earthed reliably; connect power cable; switch ON instrument; instrument begins self-checking .
  • Speed Setting: Rotate speed/timer control knob to set target speed (10-70 rpm); press knob to start rotating function; press again to stop .
  • Timer Setting: Press mode switch button to toggle to time display; rotate speed/timer control knob to set target time (up to 1199 minutes or 99h59min); press knob to start timed operation .
  • Load Balancing: Distribute tubes evenly across rollers to maintain balanced load; do not exceed maximum load capacity (4 kg / 9 lbs) .
  • Spill Management: If liquid spills onto unit, disconnect power immediately, clean thoroughly, allow to dry before reuse; drip tray contains accidental spillages .
  • Maintenance Service: If service required, instrument must be cleaned in advance to avoid pollution of hazardous substances; return in original packing .

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Gentle rolling mixing of blood samples (prevention of blood coagulation), viscous substances, liquid-solid suspensions, immune precipitation, cell suspensions, and biological fluids in clinical diagnostic, hematology, coagulation, immunology, and research laboratories .
  • Clinical Role: Essential mixing equipment in clinical diagnostic laboratories, hospital hematology laboratories, coagulation laboratories, immunology laboratories, blood banks, pharmaceutical research laboratories, and academic research facilities.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Read operating instructions carefully before use; ensure only trained staff works with instrument; ensure socket is earthed reliably; disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources .
  • Load Limits: Do not exceed maximum load capacity (4 kg / 9 lbs); ensure load is evenly distributed across rollers to prevent imbalance; if instrument does not run smoothly, decrease motor speed .
  • Spill Protection: Use appropriate tube caps or seals to prevent sample leakage; clean spills immediately; drip tray contains accidental spillages .
  • Operation Mode: For timed operation, set desired time before starting; when timer reaches zero, unit will automatically halt and alert will sound .
  • Speed Selection: Select appropriate speed for sample type (10-70 rpm); use lower speeds for blood coagulation samples to prevent platelet activation; use higher speeds for viscous substances.
  • Overload Shutdown: if rotating function suddenly stops and LCD displays "Er 03", this indicates overload protection activated; press speed/timer control knob to close rotating function; reduce load; restart rotating function .
  • Troubleshooting: If instrument cannot be powered ON, check whether power cable is connected; if instrument was damaged during transportation, contact technical support .
  • Cold Room/Incubator Use: Ensure instrument is placed on stable surface within cold room or incubator; operating temperature range 5-40°C; permissible ambient humidity ≤80% RH .
  • Training: Only trained laboratory personnel should operate the MX-T6-Pro for clinical diagnostic applications .

2. FIRST AID MEASURES

  • Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
  • Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel.
  • Overload Shutdown: If unit shuts down with "Er 03" error code, disconnect power, reduce load, allow unit to rest, restart with reduced load; if issue persists, contact service .
  • Chemical Spill: If corrosive chemicals spill on unit, disconnect power immediately, wipe with appropriate neutralizer, dry thoroughly before reconnecting power.

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn.
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires.
  • Fire Response: Unplug unit immediately; do not use water on electrical fire.