Digital Vortex Mixer (MX-S+)

WhatsApp Order
The Digital Vortex Mixer (MX-S+) is a precision benchtop vortex mixer featuring an LCD display, variable speed control (100-3000 rpm), programmable timer (1 second to 99 minutes 59 seconds), and a maintenance-free DC brushless motor. This digital mixer provides optimal, reproducible mixing for blood collection tubes, reagents, and biological samples in clinical diagnostic and research laboratories.
Key features include a large LCD digital display for real-time monitoring of speed and time, dual operating modes (touch activation for quick mixing of individual tubes, continuous mode for extended operation), variable speed control for precise adjustment of mixing intensity from gentle to vigorous, and a programmable timer for automated, reproducible mixing protocols. The DC brushless motor provides high stability, smooth operation, low noise, and maintenance-free performance.
The pressure-mounted accessory system accommodates a wide range of sample containers—including 0.2 mL PCR tubes, 1.5-2.0 mL microcentrifuge tubes, 5-50 mL conical tubes, blood collection tubes (various sizes), PCR strip tubes, and (using optional adapters) 96-well microplates. The low-profile rubber suction feet ensure stable benchtop placement, preventing “walking” during high-speed operation.
For the clinical laboratory scientist and phlebotomist, the Digital Vortex Mixer (MX-S+) ensures optimal mixing of blood collection tubes after venipuncture with digital precision—gentle speeds for light blue top coagulation tubes (PT/PTT) to prevent platelet activation, and higher speeds for lavender top EDTA tubes (CBC) and serum separator tubes to ensure thorough mixing of anticoagulants and clot activators. For the molecular biologist, it facilitates resuspension of nucleic acid pellets, mixing of PCR reaction components, and homogenization of buffers for diagnostic assays.
Universal voltage (100-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion, while the compact footprint (160 × 146 × 115 mm) and moderate weight (3.4 kg) allow easy benchtop placement. The IP21 protection class provides durability against dust and moisture in typical laboratory environments.
For the patient undergoing coagulation monitoring (warfarin, heparin), complete blood count (CBC), molecular diagnostic testing (COVID-19, influenza, hepatitis), or routine chemistry panels, the MX-S+’s digital precision, programmable timer, and versatile sample format compatibility ensure accurate test results that guide appropriate treatment decisions—preventing false-negative or false-positive results due to improper sample mixing.
Description

Digital Vortex Mixer (MX-S+)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Precision Digital Mixing for Blood Collection Tubes
  • Primary Use: Provides a digital vortex mixer with LCD display, adjustable speed control (100-3000 rpm), and programmable timer (1 second to 99 minutes 59 seconds), designed for optimal mixing of blood collection tubes at speeds appropriate for different anticoagulants and tube types.
  • How it helps: For the phlebotomist and clinical laboratory technician, the MX-S+ digital vortex mixer allows selection of precise mixing speeds for different blood collection tubes—gentler speeds (100-500 rpm) for light blue top coagulation tubes (PT/PTT) to prevent platelet activation, and higher speeds (1500-3000 rpm) for lavender top EDTA tubes (CBC) to ensure thorough mixing of anticoagulant. The LCD display provides real-time monitoring of speed and time, allowing precise control and reproducibility across operators. For the patient undergoing coagulation monitoring (warfarin, heparin) or complete blood count (CBC) testing, speed-optimized digital mixing ensures accurate test results that guide appropriate clinical management.
2. LCD Digital Display for Precise Parameter Control
  • Primary Use: Features a large LCD digital display that shows real-time rotation speed (100-3000 rpm) and run time (1 second to 99 minutes 59 seconds), enabling precise monitoring and adjustment of mixing parameters.
  • How it helps: For the clinical laboratory scientist and quality assurance manager, the digital display allows accurate setting and verification of mixing parameters for different sample types and assay protocols—ensuring consistent sample processing across runs and operators, reducing variability, and supporting GLP documentation. For the patient, standardized digital mixing protocols improve diagnostic accuracy and reduce the need for repeat testing due to inconsistent sample preparation.
3. DC Brushless Motor for Maintenance-Free Operation
  • Primary Use: Utilizes a maintenance-free DC brushless motor providing high stability, smooth operation, and low noise levels for reliable long-term laboratory use.
  • How it helps: For the laboratory manager and clinical laboratory scientist, the brushless DC motor eliminates routine brush replacement, reduces maintenance downtime, and ensures consistent performance over years of daily use—improving laboratory efficiency and reducing total cost of ownership. For the patient, reliable, consistent mixer performance ensures that sample preparation quality does not degrade over time, supporting reproducible diagnostic results.
4. Touch-Activation and Continuous Operation Modes
  • Primary Use: Features both touch-activation (press down to start) and continuous operation modes, allowing hands-free mixing for extended periods when processing multiple samples.
  • How it helps: For the clinical laboratory scientist and research technician, the dual operating modes provide flexibility—touch mode for quick mixing of individual tubes, continuous mode for extended mixing of bulk reagents or when processing multiple samples in sequence. For the patient, efficient mixing modes reduce hands-on time and potential for error, ensuring consistent sample preparation across large batches of diagnostic tests.
5. Comprehensive Accessory System for Multiple Sample Formats
  • Primary Use: Equipped with pressure-mounted accessory system compatible with various tube sizes (microcentrifuge tubes, blood collection tubes, conical tubes, PCR tubes) and optional adapters for 96-well microplates, enabling versatile sample processing.
  • How it helps: For the clinical laboratory scientist and molecular biologist, the MX-S+ accommodates a wide range of sample containers—from 0.2 mL PCR tubes and 1.5-2.0 mL microcentrifuge tubes to 15-50 mL conical tubes and blood collection tubes (various sizes)—allowing a single mixer to support diverse diagnostic workflows. For the patient, versatile sample format compatibility reduces laboratory equipment needs and streamlines sample processing across multiple test types.
6. Programmable Timer for Automated Reproducibility
  • Primary Use: Programmable timer (1 second to 99 minutes 59 seconds) allows automated, reproducible mixing protocols with automatic stop at end of set time.
  • How it helps: For the clinical laboratory scientist and high-throughput testing coordinator, the programmable timer ensures consistent mixing duration across all samples in a batch—reducing operator-dependent variability and improving workflow efficiency. For the patient, automated timing reduces the risk of under-mixing or over-mixing that could compromise sample integrity and diagnostic accuracy.

SECONDARY & SUPPORTIVE USES

1. Reagent and Sample Homogenization for Diagnostic Assays: Used to rapidly mix reagents, buffers, and biological samples (serum, plasma, urine) before analysis in clinical chemistry, immunoassay, and point-of-care testing devices.
2. Liquid Resuspension of Cell Pellets and Precipitates: Facilitates rapid resuspension of cell pellets, protein precipitates, and nucleic acid pellets in appropriate buffers using adjustable speed control to prevent foaming or shearing.
3. 96-Well Microplate Mixing for ELISA and Immunoassays: Supports uniform mixing of reagents across all 96 wells of a microplate for ELISA, immunoassays, and high-throughput screening applications (using optional microplate adapter).
4. PCR Plate Sample Preparation: Used to mix PCR reaction components in 96-well PCR plates before thermal cycling, ensuring uniform distribution of master mix, primers, probes, and template DNA (using optional microplate adapter).
5. Mixing of Microcentrifuge Tubes and PCR Strips: Supports mixing of individual microcentrifuge tubes (0.2-2.0 mL) and 0.2 mL PCR strip tubes for molecular diagnostics workflows.
6. Mixing of Larger Vessels (Conical Tubes, Flasks): Accommodates larger vessels (up to 50 mL conical tubes, small flasks) using optional flat rubber pad accessory.
7. Preparation of Serial Dilutions for Standard Curves: Used to mix serial dilutions for standard curve preparation in ELISA and other quantitative immunoassays.
8. Dissolution of Lyophilized Controls and Calibrators: Used to dissolve lyophilized quality control materials and calibrators in clinical chemistry and immunoassay laboratories.
9. Mixing of Buffers and Diluents for Manual Assays: Supports manual preparation of working reagents, dilutions, and standard curves for manual immunoassay formats.
10. Homogenization of Viscous Liquids (Glycerol, Protein Solutions): Used to mix viscous solutions to ensure homogeneous distribution of components before aliquoting.
11. Dissolution of Powders and Crystalline Materials: Used to accelerate dissolution of powdered reagents, salts, and crystalline materials into liquid solvents.
12. Preparation of Suspensions for Turbidimetric Assays: Used to mix bacterial suspensions and latex bead suspensions for turbidimetric and nephelometric immunoassays.
13. Mixing of Lipid and Lipoprotein Fractions: Supports homogenization of lipid samples for cholesterol, triglyceride, and HDL/LDL fraction analysis.
14. Quality Control Sample Preparation: Used to mix QC samples before analysis to ensure batch-to-batch consistency in clinical laboratory quality assurance programs.
15. Blood Gas and Electrolyte Sample Mixing: Used to mix heparinized blood samples before blood gas and electrolyte analysis to ensure even distribution of anticoagulant.
16. Mixing of Reagent Red Blood Cells: Used to mix reagent red blood cells, antisera, and patient samples for blood bank compatibility testing and antibody screening.
17. Point-of-Care Testing Support: Provides reliable mixing of test reagents and patient samples in point-of-care settings (physician offices, clinics, emergency departments).
18. Veterinary Diagnostic Laboratory: Supports mixing of blood, urine, and other biological specimens for animal health testing.
19. Pharmaceutical Quality Control: Supports mixing of drug formulations, dissolution media, and QC samples in pharmaceutical testing laboratories.
20. Environmental and Food Testing Laboratories: Used to mix water, soil, and food extracts for microbiological and chemical analysis.
21. Research and Academic Laboratories: Provides digital vortex mixing for routine laboratory applications in research and teaching laboratories.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A digital vortex mixer with LCD display, variable speed control (100-3000 rpm), programmable timer (1s-99min59s), and maintenance-free brushless DC motor, designed for mixing of blood tubes, reagents, and biological samples in clinical diagnostic and research laboratories.
  • Designation:Digital Vortex Mixer (MX-S+) , Digital Vortex Mixer, LCD Vortex Mixer, Laboratory Vortex Mixer, DLAB Vortex Mixer, Programmable Vortex Mixer.
  • Key Components:
o Drive Motor: Maintenance-free DC brushless motor.
o Display: LCD digital display showing speed and time.
o Operating Modes: Touch activation and continuous operation.
o Speed Control: Variable control (100-3000 rpm).
o Timer: Programmable (1 second to 99 minutes 59 seconds).
o Orbit Diameter: 4 mm.
o Cup Head: Standard cup head for individual tubes.
o Optional Accessories: Various adapters for different tube sizes, PCR strips, and 96-well microplates.
o Housing: Impact-resistant plastic body with rubber suction feet for stability.

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Speed Range: 100-3000 rpm (variable, adjustable).
  • Orbit Diameter: 4 mm.
  • Operating Modes: Touch (pressure-activated) and Continuous (switch-activated).
  • Timer Range: 1 second to 99 minutes 59 seconds (programmable).
  • Display: LCD (speed and time).
  • Motor Type: DC brushless motor (maintenance-free).
  • Motor Power: 20W input / 12W output.
  • Total Power: 24-25W.
  • Input Voltage: 24V DC power supply; 100-240V, 50/60Hz (universal voltage).
  • Dimensions (W × D × H): 160 × 146 × 115 mm.
  • Weight: 3.4 kg.
  • Noise Level: Low-noise operation.
  • Amplitude: 4 mm orbital shaking.
  • Permissible Ambient Temperature: 5-40°C.
  • Permissible Ambient Humidity: ≤80% RH.
  • Protection Class: IP21.
  • Compatibility: Standard cup head; optional adapters for 96-well microplates, microcentrifuge tubes, blood collection tubes, conical tubes, and PCR strips.

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Impact-resistant plastic body with sealed electronics for spill protection; rubber suction feet prevent "walking" during high-speed operation.
  • Display: LCD digital display for real-time monitoring of speed (100-3000 rpm) and time (1s-99min59s).
  • Operating Modes: Touch activation for quick mixing of individual tubes; continuous mode for extended mixing of bulk reagents or multiple samples.
  • Speed Control: Variable speed control allows precise adjustment of mixing intensity from gentle (100-500 rpm) to vigorous (2000-3000 rpm).
  • Timer: Programmable timer with countdown display; automatic stop at end of set time.
  • Accessory Mounting: Pressure-mounted accessory system for secure fit of various adapters.
  • Stability: Rubber suction feet provide secure benchtop placement, preventing movement during operation at high speeds.
  • Portability: Compact footprint (160 × 146 × 115 mm) and moderate weight (3.4 kg) for easy benchtop placement.
  • Maintenance: Brushless DC motor eliminates routine brush replacement.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards.
  • Safety Features: Enclosed motor with thermal protection; sealed housing prevents liquid ingress into electronics; rubber suction feet prevent movement.
  • Electrical Safety: Low-voltage DC motor (24V input); universal voltage power supply (100-240V, 50/60Hz) with over-current protection.
  • Noise Control: Low-noise operation minimizes distractions in clinical laboratory settings.
  • GLP Compliance: Digital timer and speed display support GLP documentation; programmable timer allows reproducible mixing protocols.
  • Protection Class: IP21 rating provides protection against solid objects >12mm and vertical dripping water.

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture.
  • Cleaning: Wipe exterior with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; disconnect power before cleaning.
  • Inspection: Inspect power cord and adapters for damage before each use; check rubber feet for wear.
  • Operation: For touch mode, press tube firmly into cup head until motor activates; for continuous mode, use switch/power control; adjust speed using control knob; set timer as needed using digital controls.
  • Speed Selection: Start at low speed (100-500 rpm) and increase gradually to prevent sample splashing; high speeds (2000-3000 rpm) may cause aerosol generation with open tubes.
  • Timer Setting: Set desired run time using timer controls; unit will automatically stop at end of set time.
  • Accessory Installation: Use pressure mounting for accessory attachment; ensure secure fit to prevent slippage or splashing.
  • Spill Management: If liquid spills onto unit, disconnect power immediately, clean thoroughly, allow to dry before reuse.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Digital variable-speed mixing of blood collection tubes, reagents, biological samples, and microplates for clinical chemistry, immunoassays, molecular diagnostics, hematology, and research applications.
  • Clinical Role: Essential mixing equipment in clinical diagnostic laboratories, hospital laboratories, immunology laboratories, molecular diagnostics labs, blood banks, physician office laboratories, pharmaceutical research facilities, and academic research laboratories.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources.
  • Spill Protection: Use appropriate tube caps or seals to prevent sample leakage into the mixer head; clean spills immediately.
  • Operation Mode: For continuous operation, ensure unit is set to OFF before plugging in power supply.
  • Speed Selection: Start at low speed (100-500 rpm) and increase gradually to prevent splashing; high speeds (2000-3000 rpm) may cause aerosol generation with open tubes.
  • Timer Use: Set appropriate time for mixing protocol; do not exceed recommended mixing times for sensitive samples.
  • Stability: Ensure rubber suction feet are clean and dry for secure benchtop placement; replace worn feet as needed.
  • Temperature: Unit may become warm after extended continuous operation at high speeds; allow to cool between uses.
  • Training: Only trained laboratory personnel should operate the MX-S+ for clinical diagnostic applications.

2. FIRST AID MEASURES

  • Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
  • Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel.
  • Mechanical Failure: If unit fails to operate or makes abnormal noise, disconnect power, check for obstruction, contact service if issue persists.
  • Chemical Spill: If corrosive chemicals spill on unit, wipe immediately with appropriate neutralizer, dry thoroughly before reconnecting power.

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn.
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires.
  • Fire Response: Unplug unit immediately; do not use water on electrical fire.