StepMate Stepper

WhatsApp Order
The StepMate Stepper is a slim, lightweight manual repeating pipette that transforms tedious multi-dispensing tasks into fast, accurate, single-handed operations. Engineered on the positive displacement principle, this instrument excels where air-displacement pipettes fail — handling high viscosity fluids such as glycerol and Tween, high density solutions, and volatile solvents with exceptional precision and accuracy. Available in a single-channel configuration covering a volume range from 10 μL to 5 mL, this pipette provides the versatility required for high-throughput and routine laboratory workflows across clinical diagnostics, molecular biology, and pharmaceutical quality control.
Every StepMate Stepper is factory calibrated according to ISO 8655 standards, delivering outstanding systematic error as low as ±0.2% and random error (CV) as low as ≤0.2% at higher volumes. The instrument accepts seven sizes of disposable polypropylene dispenser syringes from 0.5 mL to 50 mL, offering up to 48 dispensing steps from a single fill. The entire unit is fully autoclavable at 121°C for 20 minutes without disassembly, ensuring sterility for aseptic applications in cell culture and microbiology.
Key ergonomic features include a lightweight body weighing only 0.5 kg, a smooth filling slide bar, an ambidextrous grip for right-handed or left-handed use, and a volume locking system to prevent accidental setting changes. A durable tip stop lever secures syringes firmly in place, and the five-position dial allows quick selection of step volumes without calculation.
For the clinical laboratory scientist and molecular biologist, the StepMate Stepper delivers the accuracy, reproducibility, and ergonomic comfort required for high-throughput ELISA, PCR master mix distribution, and clinical chemistry reagent preparation. For the patient, consistent, error-free repeat dispensing ensures that diagnostic results are reproducible and reliable, directly supporting timely and effective clinical decision making.
Description

StepMate Stepper

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Positive Displacement for Difficult Liquids
Primary Use: Provides a manual, positive-displacement repeating pipette with a mechanical stepped volume control mechanism, used for the accurate and reproducible dispensing of high viscosity, high density, and high vapor pressure liquids including glycerol, Tween detergents, concentrated acids, and volatile organic solvents without the volume errors common in air-displacement pipettes.
How it helps: For the molecular biologist and formulation chemist, the StepMate’s positive displacement piston moves directly inside the disposable syringe tip, eliminating the air gap that causes volume inaccuracy with viscous or volatile fluids. This design delivers systematic error as low as ±0.2% and random error (CV) as low as ≤0.2% at higher volumes, far exceeding the performance of standard air-displacement pipettes for difficult liquids. For the patient receiving pharmaceutical formulations or diagnostic test results, this accuracy ensures that critical reagents such as enzyme concentrates or volatile solvents are delivered exactly as specified, directly supporting batch consistency and test reliability.
2. Multi-Step Reagent Dispensing Without Refilling
Primary Use: Enables up to 48 successive dispensing steps from a single syringe fill, with five easy-to-select dial settings that control dispensing volume, used for distributing master mixes, buffers, or detection reagents across multi-well plates or reaction tube racks in high-throughput workflows.
How it helps: For the high-throughput laboratory technician and clinical research associate, the StepMate’s ability to dispense 48 times without refilling dramatically reduces workflow interruptions and repetitive strain injuries. The intuitive volume locking system prevents accidental volume changes during operation. For the patient, reduced handling steps and consistent reagent distribution across all wells of a 96-well plate minimize well-to-well variability, supporting reproducible results in infectious disease testing, genetic screening, and oncology biomarker detection.
3. Autoclavable Contamination Control for Aseptic Work
Primary Use: The entire instrument is constructed from chemically resistant polymers and is fully autoclavable without disassembly at 121°C for 20 minutes, and is compatible with sterile, individually wrapped dispenser tips certified free of DNA, RNase, and endotoxins.
How it helps: For the cell culture specialist and pharmaceutical quality control scientist, the ability to autoclave the complete unit without disassembly eliminates the risk of cross-contamination between sensitive cell lines or sterile reagents. The robust, corrosion-resistant materials withstand repeated autoclaving cycles without degradation. For the patient receiving cell-based therapies or sterile injectable drugs, rigorous sterilization of dispensing equipment ensures that therapeutic products are not adulterated by contaminants, maintaining the safety and integrity of the final product.
4. Single-Handed Ergonomic Operation to Minimize Fatigue
Primary Use: The pipette features a lightweight, slim body (0.5 kg), a smooth filling slide bar, a durable tip stop lever, and an ergonomic grip designed for both right-handed and left-handed single-handed operation without hand switching.
How it helps: For the laboratory staff member performing hundreds of repeat dispensing steps daily, the ergonomic lightweight design and low-force filling mechanism reduce the risk of repetitive strain injury (RSI) and hand fatigue. The ambidextrous operation allows comfortable use by all staff regardless of handedness. For the patient, this fatigue-preventing design contributes to consistent, error-free sample handling throughout long shifts, supporting day-to-day reproducibility of diagnostic tests and clinical research results.

SECONDARY & SUPPORTIVE USES

1. ELISA and immunoassay plate loading: Dispenses antibodies, wash buffers, and substrates across 96-well plates with uniform distribution, with up to 48 consistent aliquots per fill, ensuring reproducible immunoassay results.
2. qPCR and PCR master mix distribution: Delivers precise volumes of master mix, primers, probes, and templates into 96-well or 384-well reaction plates without cross-contamination, supporting accurate gene expression and pathogen detection.
3. Cell culture media and supplement addition: Dispenses sterile media, serum, antibiotics, and growth factors into culture flasks or multi-well plates for cell propagation experiments under aseptic conditions.
4. Enzymatic assay preparation: Delivers enzyme solutions, cofactors, substrates, and stop solutions for kinetic and endpoint assays requiring precise, repetitive addition with minimal variability.
5. Protein quantification assays: Adds Bradford, BCA, or Lowry reagents into standard cuvettes or microplates with exceptional volume accuracy for protein concentration determination in research and QC labs.
6. DNA and RNA extraction workflows: Dispenses binding buffers, wash buffers, and elution solutions into spin columns or magnetic bead-based purification systems, ensuring consistent nucleic acid yields.
7. Pharmaceutical quality control: Delivers test solutions, dissolution media, and QC samples during drug product analysis where consistent volume delivery is mandatory for regulatory compliance.
8. Clinical chemistry reagent preparation: Dispenses calibrators, controls, and reagents for routine chemistry panels and metabolite analysis on benchtop clinical analyzers.
9. Blood bank and transfusion medicine: Dispenses red blood cell suspensions, antisera, and reagent red cells for ABO/Rh typing and compatibility testing with high reproducibility.
10. Food and beverage safety testing: Prepares food homogenates, enrichment broths, and PCR reagents for pathogen detection such as Salmonella, Listeria, and E. coli O157:H7.
11. Environmental monitoring: Dispenses water, soil extract, and wastewater samples for microbial analysis, coliform testing, and water quality monitoring in public health laboratories.
12. Forensic DNA analysis: Loads PCR products and DNA extracts for STR analysis in forensic casework, where microliter precision and contamination control are critical for evidence integrity.
13. Next-generation sequencing (NGS) library preparation: Dispenses adapters, indexes, and master mixes where even small volume errors can significantly affect library quality and sequencing results.
14. Drug discovery and high-throughput screening: Dispenses compounds, cells, and assay reagents into 96-well and 384-well plates for pharmaceutical research and screening campaigns.
15. Academic research and teaching labs: Serves as an intuitive, durable teaching tool for students learning precise repetitive liquid handling techniques in laboratory courses.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A manual, positive-displacement repeating pipette with a mechanical stepped volume control mechanism, available as a single-channel repeating dispenser.
  • Designation: StepMate Stepper, DLAB StepMate Stepper, Scilogex StepMate Repeater Pipettor, AELAB StepMate Stepper.
  • Key Components:
    • Ergonomic hand grip with single-handed operation design
    • Easy-to-select dial with 5 fixed volume settings (positions 1 through 5)
    • Filling slide bar for rapid syringe loading
    • Durable tip stop lever for secure syringe retention
    • Volume locking system to prevent accidental setting changes
    • Chemically resistant, autoclavable polymer body
    • Universal tip cone compatible with 0.5 mL to 50 mL dispenser syringes

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Volume range: 10 μL to 5 mL (depends on syringe size and dial setting)
  • Dispensing steps: Up to 48 successive steps from a single fill
  • Syringe compatibility: Fits 7 sizes of disposable polypropylene syringe tips: 0.5 mL, 1.25 mL, 2.5 mL, 5.0 mL, 12.5 mL, 25.0 mL, and 50.0 mL
  • Dial settings and step counts: Setting 1 gives 48 steps, Setting 2 gives 23 steps, Setting 3 gives 15 steps, Setting 4 gives 11 steps, Setting 5 gives 8 steps
  • Example accuracy with 0.5 mL syringe at 50 μL: Systematic error ±0.8%, random error (CV) ≤0.7%
  • Example accuracy with 1.25 mL syringe at 125 μL: Systematic error ±0.8%, random error (CV) ≤0.5%
  • Example accuracy with 50 mL syringe at 5000 μL: Systematic error ±0.2%, random error (CV) ≤0.2%
  • Sterilization: Fully autoclavable at 121°C, 1 bar for 20 minutes without disassembly; compatible with sterile dispenser tips
  • Operation: Single-handed, ambidextrous design with smooth filling slide bar
  • Maintenance: Maintenance-free design requiring no routine lubrication or calibration
  • Compatibility: Compatible with most manufacturers' Eppendorf-style Combitips and similar universal repeating pipette syringe tips
  • Construction material: Chemical and corrosion-resistant polymer resistant to a wide range of laboratory reagents
  • Quality compliance: Factory calibrated; meets ISO 8655 standards for volumetric instruments; CE marked

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Slim, light, and robust chemical-resistant polymer body with smooth, easy-to-clean surface
  • Weight: Approximately 0.5 kg
  • Operation: Manual, single-handed thumb and slide bar operation
  • Volume adjustment: Rotary dial with five easy-to-select fixed volume settings; volume locking system prevents accidental changes
  • Syringe filling: Smooth slide bar mechanism for rapid, single-handed syringe loading
  • Syringe retention: Durable tip stop lever secures syringe firmly in place
  • Tip compatibility: Universal tip cone fits seven sizes of disposable polypropylene dispenser syringes from 0.5 mL to 50 mL
  • Portability: Compact, lightweight design for easy benchtop storage and transport; can be stored upright in a pipette stand
  • Ambidextrous design: Usable with either left hand or right hand; no hand switching required
  • Maintenance: Maintenance-free design; factory calibrated, no user calibration needed
  • Warranty: 3-year manufacturer's warranty

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic (IVD) use; manufactured under ISO quality systems
  • Sterilization Safety: Fully autoclavable without disassembly; after autoclaving, allow to cool and dry before use; chemical-resistant materials withstand repeated autoclaving
  • Chemical Resistance: Constructed from advanced polymers that resist a wide range of laboratory chemicals, acids, organic solvents, detergents, and tissue culture reagents
  • Tip Seal Verification: Positive displacement design prevents leakage and ensures accurate volume delivery, especially for volatile liquids where air-displacement pipettes fail
  • Contamination Control: Compatible with sterile, individually wrapped tips certified free of DNA, RNase, endotoxins, and ATP for critical molecular biology applications
  • Safety Lock: Volume locking system prevents accidental setting changes during operation, reducing error and reagent waste
  • Quality Compliance: Factory calibrated; meets ISO 8655 volumetric instrument standards; each unit quality tested before shipment

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store upright in a pipette stand to protect the tip cone; do not lay the instrument on its side with a syringe inserted
  • Cleaning: Wipe exterior surfaces with 70% isopropyl alcohol or a mild detergent solution; do not immerse the pipette in liquid
  • Autoclaving: Entire instrument can be autoclaved without disassembly at 121°C, 1 bar for 20 minutes. After autoclaving, allow the instrument to cool and dry before use
  • Pre-use inspection: Before each use, inspect the tip cone for damage and ensure the syringe tip is securely seated using the stop lever
  • Syringe loading: Pull the slide bar fully upward; insert the syringe tip firmly; push the slide bar downward to fill
  • Dispensing technique: Press the operating button to dispense; each click advances one step; repeat until all steps are complete
  • Discard first and last dispense: For maximum accuracy, discard the first and last dispensed aliquots from each syringe fill
  • Syringe replacement: Remove empty syringe tip using the stop lever; discard according to laboratory biohazard procedures; load a fresh syringe for subsequent use
  • Inspection: Periodically inspect the slide bar mechanism for smooth operation; no routine lubrication is required

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Precision repeat dispensing of liquids in clinical diagnostics (ELISA, PCR, clinical chemistry), molecular biology (DNA/RNA extraction, NGS library preparation), pharmaceutical quality control, cell culture, and general research, where accurate, reproducible repeat dispensing is required.
  • Clinical Role: An essential instrument for clinical diagnostic laboratories, molecular diagnostics labs, immunology laboratories, blood banks, pathology departments, pharmaceutical QC facilities, and research institutions; critical for high-throughput reagent distribution, patient sample processing, and sterile media preparation where consistent, error-free repeat dispensing is mandatory.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Chemical Compatibility: Verify that the syringe tip material (polypropylene, polyethylene) is compatible with the specific reagents used. Some aggressive organic solvents may affect syringe performance.
  • Autoclaving Preparation: The entire instrument can be autoclaved without disassembly. After autoclaving, allow the instrument to cool and dry before use. Do not autoclave disposable syringe tips; use pre-sterilized tips.
  • Syringe Fit: Ensure the syringe tip is securely seated and locked by the stop lever before aspirating; a loose syringe may cause inaccurate volume delivery or sample loss.
  • Dispensing Technique: Depress the operating button completely for each step. Do not force the mechanism; smooth, consistent pressure ensures even volume distribution.
  • Avoid Dropping: Dropping the instrument may damage the internal piston mechanism; if dropped, inspect for damage before reuse.
  • Cleaning: Do not immerse the entire instrument in liquid; wipe exterior surfaces only.
  • Discard First and Last Dispense: To achieve specified accuracy, discard the first and last dispensed aliquot from each syringe fill.
  • Personal Protective Equipment: Always wear appropriate PPE including gloves and lab coat when handling biological or chemical samples.
  • Training: Only trained laboratory personnel should operate the StepMate Stepper for clinical diagnostic and research applications.

2. FIRST AID MEASURES

  • Sample Splash to Eyes: If a biological or chemical sample splashes into the eyes, flush immediately with water for 15 minutes and seek medical attention.
  • Skin Contact with Sample: Wash contaminated skin with soap and water thoroughly; if irritation develops, seek medical evaluation.
  • Sharps Injury (Syringe Tip): If a dispenser tip punctures the skin, wash the wound thoroughly and follow the facility's exposure management protocol for bloodborne pathogens.
  • Chemical Exposure: If the instrument is contaminated with a hazardous chemical, refer to the specific Safety Data Sheet (SDS) for detailed first aid instructions.
  • Inhalation: If chemical vapors from volatile solvents are inhaled during dispensing, move to fresh air immediately; seek medical attention if symptoms persist.
  • Autoclave Burn: If handling the instrument immediately after autoclaving, use heat-resistant gloves; if a burn occurs, cool the area with cool running water for 15 minutes and seek medical attention.

3. FIRE FIGHTING MEASURES

  • Flammability: The plastic components of the instrument body and polypropylene dispenser syringes are combustible; they may melt or burn if exposed to flame or high heat.
  • Extinguishing Media: Use carbon dioxide (CO₂) or a dry chemical extinguisher for fires involving plastic materials.
  • Fire Response: The primary fire hazard is the flammable laboratory reagents being handled; follow the laboratory's fire safety protocols. Evacuate the area if volatile organic solvents are in use.