Variable speed Vortex Mixer (MX-S)

WhatsApp Order
The Variable speed Vortex Mixer (MX-S) is a versatile benchtop vortex mixer with adjustable speed control (0-3000 rpm), analog scale speed display, and touch/continuous operation modes, designed for optimal mixing of blood collection tubes, reagents, and biological samples in clinical diagnostic and research laboratories . With variable speed control, operators can select the appropriate mixing intensity for different sample types—gentle speeds (0-500 rpm) for resuspension of cell pellets and coagulation tubes to prevent platelet activation, moderate speeds (500-1500 rpm) for routine reagent mixing, and high speeds (1500-3000 rpm) for rapid mixing of buffers and viscous solutions .
Key features include dual operating modes—touch activation for quick mixing of individual tubes and continuous operation for extended mixing of bulk reagents or multiple samples, variable speed control knob for precise adjustment of mixing intensity (0-3000 rpm) with analog scale display for visual confirmation, and optional accessories including multi-tube head for 0.2 mL PCR strips and flat rubber pad for larger vessels (up to 50 mL conical tubes, small flasks) .
For the clinical laboratory scientist and phlebotomist, the Variable speed Vortex Mixer (MX-S) ensures optimal mixing of blood collection tubes after venipuncture with speed selection appropriate for different tube types—gentle speeds for light blue top coagulation tubes (PT/PTT) to prevent platelet activation, and higher speeds for lavender top EDTA tubes (CBC) and serum separator tubes to ensure thorough mixing of anticoagulants and clot activators . For the molecular biologist, the MX-S facilitates resuspension of nucleic acid pellets, mixing of PCR reaction components, and homogenization of buffers for diagnostic assays .
Universal voltage (100-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion, while the compact footprint (127 × 130 × 160 mm) and lightweight design (2.0 kg) allow easy benchtop placement . Rubber suction feet prevent “walking” during high-speed operation, and low-noise operation ensures a comfortable working environment .
For the patient undergoing coagulation monitoring (warfarin, heparin), complete blood count (CBC), molecular diagnostic testing (COVID-19, influenza, hepatitis), or routine chemistry panels, the Variable speed Vortex Mixer (MX-S) variable-speed, optimized mixing ensures accurate test results that guide appropriate treatment decisions—preventing false-negative or false-positive results due to improper sample mixing .
Description

 Variable speed Vortex Mixer (MX-S)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Adjustable Speed Mixing for Blood Collection Tubes
  • Primary Use: Provides a variable-speed vortex mixer with adjustable speed control (0-3000 rpm) and touch/continuous operation modes, designed for optimal mixing of blood collection tubes at speeds appropriate for different anticoagulants and tube types.
  • How it helps: For the phlebotomist and clinical laboratory technician, the Variable speed Vortex Mixer (MX-S) allows selection of precise mixing speeds for different blood collection tubes—gentler speeds (200-500 rpm) for light blue top coagulation tubes (PT/PTT) to prevent platelet activation, and higher speeds (1500-3000 rpm) for lavender top EDTA tubes (CBC) to ensure thorough mixing of anticoagulant. Speed adjustment can be made via the intuitive control knob with analog scale display, allowing operators to dial in the exact speed needed for each application . For the patient undergoing coagulation monitoring (warfarin, heparin) or complete blood count (CBC) testing, speed-optimized variable mixing ensures accurate test results that guide appropriate clinical management.
2. Reagent and Sample Homogenization for Diagnostic Assays
  • Primary Use: Used to rapidly mix reagents, buffers, and biological samples (serum, plasma, urine) at adjustable speeds (0-3000 rpm) before analysis in clinical chemistry, immunoassay, and point-of-care testing devices .
  • How it helps: For the clinical laboratory scientist, the Variable speed Vortex Mixer (MX-S) control allows selection of appropriate mixing intensity—gentle speeds for resuspension of cell pellets and sensitive samples, higher speeds for rapid mixing of reagents and buffers. The mixer uses a vortex action to effectively mix small volumes of liquid in tubes quickly and efficiently . For the patient undergoing diagnostic testing for cardiac biomarkers (troponin), metabolic panels, or infectious diseases, appropriate mixing speed improves the accuracy and reliability of test results that guide treatment decisions.
3. Dual Operating Modes for Workflow Flexibility
  • Primary Use: Features both touch-activation (press down to start) and continuous operation modes, allowing hands-free mixing for extended periods when processing multiple samples .
  • How it helps: For the clinical laboratory scientist and research technician, the dual operating modes provide flexibility—touch mode for quick mixing of individual tubes, continuous mode for extended mixing of bulk reagents or when processing multiple samples in sequence. The continuous mode is activated by a toggle switch at the base of the unit, while touch mode is activated by pressing the tube onto the cup head . For the patient, efficient mixing modes reduce hands-on time and potential for error, ensuring consistent sample preparation across large batches of diagnostic tests.
4. Liquid Resuspension of Cell Pellets and Precipitates
  • Primary Use: Facilitates rapid resuspension of cell pellets, protein precipitates, and nucleic acid pellets in appropriate buffers using adjustable speed control to prevent foaming or shearing .
  • How it helps: For the molecular biologist and clinical laboratory scientist, the Variable speed Vortex Mixer (MX-S) low-speed capability (down to 0 rpm with gradual ramp-up) allows gentle resuspension of delicate biological materials—preserving the integrity of cells, proteins, and nucleic acids for downstream molecular diagnostics . For the patient, gentle resuspension ensures that aliquots taken for PCR, ELISA, or other diagnostic platforms accurately represent the original specimen.
5. Variable Speed Control with Analog Scale Display
  • Primary Use: Features variable speed control with analog scale display (0-3000 rpm), allowing operators to select the exact speed needed for each application—from gentle mixing of delicate samples to high-speed vortexing of difficult solutions .
  • How it helps: For the clinical laboratory scientist and research technician, the analog speed display provides immediate visual feedback of current operating speed, allowing rapid adjustment without navigating digital menus—reducing setup time and improving workflow efficiency . For the patient, simplified operation reduces the potential for operator error that could compromise sample integrity and diagnostic accuracy.

SECONDARY & SUPPORTIVE USES

1. Mixing of Microcentrifuge Tubes and PCR Strips: Supports mixing of individual microcentrifuge tubes (0.2-2.0 mL) and 0.2 mL PCR strip tubes using optional multi-tube head accessory .
2. Mixing of Larger Vessels (Conical Tubes, Small Flasks): Accommodates larger vessels (up to 50 mL conical tubes, small flasks) using optional flat rubber pad accessory .
3. Preparation of Serial Dilutions for Standard Curves: Used to mix serial dilutions for standard curve preparation in ELISA and other quantitative immunoassays.
4. Dissolution of Lyophilized Controls and Calibrators: Used to dissolve lyophilized quality control materials and calibrators in clinical chemistry and immunoassay laboratories .
5. Mixing of Buffers and Diluents for Manual Assays: Supports manual preparation of working reagents, dilutions, and standard curves for manual immunoassay formats.
6. Homogenization of Viscous Liquids (Glycerol, Protein Solutions): Used to mix viscous solutions to ensure homogeneous distribution of components before aliquoting.
7. Dissolution of Powders and Crystalline Materials: Used to accelerate dissolution of powdered reagents, salts, and crystalline materials into liquid solvents.
8. Preparation of Suspensions for Turbidimetric Assays: Used to mix bacterial suspensions and latex bead suspensions for turbidimetric and nephelometric immunoassays .
9. Mixing of Lipid and Lipoprotein Fractions: Supports homogenization of lipid samples for cholesterol, triglyceride, and HDL/LDL fraction analysis.
10. Quality Control Sample Preparation: Used to mix QC samples before analysis to ensure batch-to-batch consistency in clinical laboratory quality assurance programs .
11. Point-of-Care Testing Support: Provides reliable mixing of test reagents and patient samples in point-of-care settings (physician offices, clinics, emergency departments).
12. Blood Gas and Electrolyte Sample Mixing: Used to mix heparinized blood samples before blood gas and electrolyte analysis to ensure even distribution of anticoagulant.
13. Mixing of Reagent Red Blood Cells: Used to mix reagent red blood cells, antisera, and patient samples for blood bank compatibility testing and antibody screening .
14. Veterinary Diagnostic Laboratory: Supports mixing of blood, urine, and other biological specimens for animal health testing .
15. Pharmaceutical Quality Control: Supports mixing of drug formulations, dissolution media, and QC samples in pharmaceutical testing laboratories .
16. Environmental and Food Testing Laboratories: Used to mix water, soil, and food extracts for microbiological and chemical analysis .
17. Research and Academic Laboratories: Provides variable-speed vortex mixing for routine laboratory applications in research and teaching laboratories.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A variable-speed vortex mixer with analog scale speed display (0-3000 rpm), touch-activation and continuous operation modes, designed for mixing of blood tubes, reagents, and biological samples in clinical diagnostic and research laboratories .
  • Designation: MX-S Variable Speed Vortex Mixer, Variable Speed Vortex Mixer, Laboratory Vortex Mixer, Benchtop Vortex Mixer, DLAB Vortex Mixer .
  • Key Components:
o Drive Motor: Heavy-duty variable-speed motor .
o Operating Modes: Touch activation (press down to start) and continuous operation (switch on) .
o Speed Control: Variable speed control knob with analog scale display (0-3000 rpm) .
o Cup Head: Standard cup head for individual microcentrifuge tubes and vials .
o Optional Accessories: Multi-tube head for 0.2 mL PCR strip tubes, flat rubber pad for larger vessels .
o Housing: Impact-resistant plastic body with rubber suction feet for stability .
o Power Switch: Rocker switch for continuous operation mode activation .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Speed Range: 0-3000 rpm (variable, adjustable) .
  • Operating Modes: Touch (pressure-activated) and Continuous (switch-activated) .
  • Orbit Diameter: 4 mm .
  • Capacity: Standard cup head accommodates individual tubes (0.2 mL to 50 mL depending on accessory) .
  • Speed Display: Analog scale (0-3000 rpm knob scale) .
  • Voltage/Frequency: 100-240V, 50/60Hz (universal voltage) .
  • Power: 60W .
  • Dimensions (W × D × H): 127 × 130 × 160 mm .
  • Weight: 2.0 kg .
  • Noise Level: Low-noise operation .
  • Footing: Rubber suction feet prevent "walking" during operation .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Impact-resistant plastic body with sealed electronics for spill protection .
  • Operating Modes: Touch activation for quick mixing of individual tubes; continuous mode for extended mixing of larger volumes or multiple samples .
  • Speed Control: Variable speed control knob allows precise adjustment of mixing intensity from gentle (0-500 rpm) to vigorous (2000-3000 rpm); analog scale provides visual confirmation of speed setting .
  • Cooling: Built-in cooling fan for extended continuous operation .
  • Stability: Rubber suction feet provide secure benchtop placement, preventing movement during operation at high speeds .
  • Portability: Compact footprint (127 × 130 × 160 mm) and light weight (2.0 kg) for easy benchtop placement .
  • Maintenance: Simple external cleaning; no routine internal maintenance required .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards .
  • Safety Features: Enclosed motor with thermal protection; sealed housing prevents liquid ingress into electronics .
  • Electrical Safety: 60W low-power consumption; universal voltage (100-240V) for international use .
  • Noise Control: Low-noise operation minimizes distractions in clinical laboratory settings .
  • Stability: Rubber suction feet prevent accidental displacement during operation at high speeds .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture.
  • Cleaning: Wipe exterior with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; disconnect power before cleaning .
  • Inspection: Inspect power cord for damage before each use; check rubber feet for wear .
  • Operation: For touch mode, press tube firmly into cup head until motor activates; for continuous mode, switch rocker switch to ON position; adjust speed using control knob .
  • Speed Selection: Start at low speed (200-500 rpm) and increase gradually to prevent sample splashing; analog scale provides visual feedback of current speed setting .
  • Accessories: Optional multi-tube head for 0.2 mL PCR strips and flat rubber pad for larger vessels available separately .
  • Spill Management: If liquid spills onto unit, disconnect power immediately, clean thoroughly, allow to dry before reuse .

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Variable-speed mixing of blood collection tubes, reagents, biological samples, and resuspension of pellets for clinical diagnostic laboratories, molecular diagnostics, point-of-care testing, and research applications .
  • Clinical Role: Essential mixing equipment in clinical diagnostic laboratories, hospital laboratories, physician office laboratories, blood banks, molecular diagnostics labs, and research facilities .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources .
  • Spill Protection: Use appropriate tube sealing to prevent sample leakage into the mixer head; clean spills immediately .
  • Operation Mode: For continuous operation, ensure switch is in OFF position before plugging in unit .
  • Speed Selection: Start at low speed (200-500 rpm) and increase gradually to prevent splashing; high speeds (2000-3000 rpm) may cause aerosol generation with open tubes .
  • Tube Selection: Use appropriate tube size for cup head; do not force oversized tubes into cup head .
  • Stability: Ensure rubber suction feet are clean and dry for secure benchtop placement; replace worn feet as needed .
  • Temperature: Unit may become warm after extended continuous operation at high speeds; allow to cool between uses .
  • Training: Only trained laboratory personnel should operate the MX-S for clinical diagnostic applications .

2. FIRST AID MEASURES

  • Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water .
  • Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel .
  • Mechanical Failure: If unit fails to operate or makes abnormal noise, disconnect power, check for obstruction, contact service if issue persists .
  • Chemical Spill: If corrosive chemicals spill on unit, wipe immediately with appropriate neutralizer, dry thoroughly before reconnecting power .

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn .
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires .
  • Fire Response: Unplug unit immediately; do not use water on electrical fire .