Digital Vortex Mixer + 96-well microplate (MX-S+)

WhatsApp Order
The MX-S+ Digital Vortex Mixer is a precision benchtop mixer equipped with a 96-well microplate adapter. It features an LCD display, variable speed control (100-3000 rpm), a programmable timer (1 second to 99 minutes 59 seconds), and a maintenance-free DC brushless motor. This versatile system is designed for high-throughput mixing of 96-well microplates for ELISA and immunoassays, as well as individual blood collection tubes, PCR tubes, and centrifuge tubes.
For the clinical laboratory scientist, the MX-S+ with its microplate capability ensures uniform mixing across all 96 wells, reducing well-to-well variability and improving the sensitivity of diagnostic assays for autoimmune and infectious diseases. For the patient, this technology ensures accurate antibody detection and reliable test results that guide treatment decisions.
Description

 Digital Vortex Mixer + 96-well microplate (MX-S+)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. High-Throughput Mixing for ELISA and Microplate Assays
  • Primary Use: Provides a digital vortex mixer with an LCD display, adjustable speed control (100-3000 rpm), and a programmable timer, specifically equipped to accommodate a 96-well microplate for uniform mixing of ELISA reagents and high-throughput immunoassay samples.
  • How it helps: For the clinical laboratory scientist and immunology technologist, the MX-S+ with its 96-well microplate capability ensures consistent, reproducible mixing of antigens, antibodies, and enzyme conjugates across all wells of the plate. This is critical for reducing well-to-well variability and improving assay sensitivity in high-throughput diagnostic testing. The LCD display provides real-time monitoring, allowing precise control of mixing parameters for different ELISA protocols. For the patient undergoing autoimmune disease testing (e.g., ANA, rheumatoid factor) or infectious disease serology (HIV, hepatitis), reliable microplate mixing ensures accurate antibody detection that guides appropriate treatment decisions.
2. Precision Digital Mixing for Blood Collection Tubes
  • Primary Use: Features a standard cup head for individual tubes, allowing the operator to select precise mixing speeds (100-3000 rpm) for different blood collection tubes—gentler speeds for coagulation tubes to prevent platelet activation, and higher speeds for EDTA tubes to ensure thorough mixing.
  • How it helps: For the phlebotomist and clinical laboratory technician, the digital speed control and LCD display allow accurate setting and verification of mixing parameters for different tube types. This ensures consistent sample processing across runs and operators, reducing variability. For the patient undergoing coagulation monitoring (PT/PTT) or a complete blood count (CBC), speed-optimized digital mixing ensures accurate test results that guide appropriate clinical management.
3. LCD Display for Precise Parameter Control
  • Primary Use: Features a large LCD digital display that shows real-time rotation speed (100-3000 rpm) and run time (1 second to 99 minutes 59 seconds), enabling precise monitoring and adjustment of mixing parameters.
  • How it helps: For the quality assurance manager, the digital display allows accurate setting and verification of mixing protocols, supporting GLP documentation. For the patient, standardized digital mixing protocols improve diagnostic accuracy and reduce the need for repeat testing due to inconsistent sample preparation.
4. DC Brushless Motor for Maintenance-Free Operation
  • Primary Use: Utilizes a maintenance-free DC brushless motor providing high stability, smooth operation, and low noise levels for reliable long-term laboratory use with both the 96-well microplate and standard tubes.
  • How it helps: For the laboratory manager, the brushless DC motor eliminates routine brush replacement, reduces maintenance downtime, and ensures consistent performance over years of daily use—improving laboratory efficiency. For the patient, reliable mixer performance ensures that sample preparation quality does not degrade over time, supporting reproducible diagnostic results.
5. Dual Operating Modes for Workflow Flexibility
  • Primary Use: Supports both touch-activation mode for quick mixing of individual tubes and continuous operation mode for extended mixing of the 96-well microplate or bulk reagents.
  • How it helps: For the clinical laboratory scientist, the dual operating modes provide flexibility—touch mode for rapid mixing of individual patient samples, and continuous mode for the 96-well microplate to ensure uniform mixing across all wells during ELISA incubation steps. For the patient, efficient mixing modes reduce hands-on time and potential for error, ensuring consistent sample preparation across large batches of diagnostic tests.

SECONDARY & SUPPORTIVE USES

1. PCR Plate Sample Preparation: Used to mix PCR reaction components in 96-well PCR plates before thermal cycling (using optional plate adapter).
2. Liquid Resuspension of Cell Pellets and Precipitates: Facilitates rapid resuspension of cell pellets, protein precipitates, and nucleic acid pellets in appropriate buffers using adjustable speed control to prevent foaming or shearing.
3. Mixing of Microcentrifuge Tubes and PCR Strips: Supports mixing of individual microcentrifuge tubes (0.2-2.0 mL) and 0.2 mL PCR strip tubes.
4. Mixing of Larger Vessels (Conical Tubes): Accommodates larger vessels (up to 50 mL conical tubes) using an optional flat rubber pad accessory.
5. Preparation of Serial Dilutions for Standard Curves: Used to mix serial dilutions for standard curve preparation in ELISA and other quantitative immunoassays, using either the microplate or individual tubes.
6. Dissolution of Lyophilized Controls and Calibrators: Used to dissolve lyophilized quality control materials and calibrators in clinical chemistry and immunoassay laboratories.
7. Mixing of Reagent Red Blood Cells: Used to mix reagent red blood cells, antisera, and patient samples for blood bank compatibility testing and antibody screening.
8. Homogenization of Liquid Samples for Chemistry Analyzers: Used to mix serum, plasma, or urine samples before loading onto automated chemistry analyzers.
9. Quality Control Sample Preparation: Used to mix QC samples before analysis to ensure batch-to-batch consistency in clinical laboratory quality assurance programs.
10. Preparation of Suspensions for Turbidimetric Assays: Used to mix bacterial suspensions and latex bead suspensions for turbidimetric and nephelometric immunoassays.
11. Blood Gas and Electrolyte Sample Mixing: Used to mix heparinized blood samples before blood gas and electrolyte analysis to ensure even distribution of anticoagulant.
12. Pharmaceutical Quality Control: Supports mixing of drug formulations, dissolution media, and QC samples in pharmaceutical testing laboratories.
13. Research and Academic Laboratories: Provides digital vortex mixing for routine laboratory applications in research and teaching laboratories.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A digital vortex mixer with LCD display, variable speed control (100-3000 rpm), and programmable timer (1s-99min59s), specifically equipped to accommodate a 96-well microplate and standard tubes for clinical diagnostic and research laboratories.
  • Designation: MX-S+ Digital Vortex Mixer + 96-well microplate, Digital Vortex Mixer, LCD Vortex Mixer, Laboratory Vortex Mixer, Microplate Vortex Mixer.
  • Key Components:
    • Drive Motor: Maintenance-free DC brushless motor .
    • Display: LCD digital display showing speed and time .
    • Operating Modes: Touch activation and continuous operation .
    • Speed Control: Variable control (100-3000 rpm) .
    • Timer: Programmable (1 second to 99 minutes 59 seconds) .
    • Orbit Diameter: 4 mm .
    • Standard Cup Head: For individual tubes .
    • 96-Well Microplate Capability: Unit is configured to accept a 96-well microplate via pressure-mounted accessory system .
    • Housing: Impact-resistant plastic body with rubber suction feet for stability .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Speed Range: 100-3000 rpm (variable, adjustable) .
  • Orbit Diameter: 4 mm .
  • Operating Modes: Touch (pressure-activated) and Continuous (switch-activated) .
  • Timer Range: 1 second to 99 minutes 59 seconds (programmable) .
  • Display: LCD (speed and time) .
  • Motor Type: DC brushless motor (maintenance-free) .
  • Motor Power: 20W input / 12W output .
  • Total Power: 24-25W .
  • Input Voltage: 24V DC power supply; 100-240V, 50/60Hz (universal voltage) .
  • Dimensions (W × D × H): 160 × 146 × 115 mm .
  • Weight: 3.4 kg .
  • Noise Level: Low-noise operation .
  • Amplitude: 4 mm orbital shaking .
  • Permissible Ambient Temperature: 5-40°C .
  • Permissible Ambient Humidity: ≤80% RH .
  • Protection Class: IP21 .
  • Compatibility: Standard cup head; 96-well microplate adapter; various tube adapters for microcentrifuge tubes, blood collection tubes, conical tubes, and PCR strips .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Impact-resistant plastic body with sealed electronics; rubber suction feet prevent "walking" during high-speed operation.
  • Display: LCD digital display for real-time monitoring of speed (100-3000 rpm) and time (1s-99min59s).
  • Operating Modes: Touch activation for quick mixing of individual tubes; continuous mode for extended mixing of the 96-well microplate or bulk reagents.
  • Speed Control: Variable speed control allows precise adjustment of mixing intensity from gentle (100-500 rpm) to vigorous (2000-3000 rpm).
  • Timer: Programmable timer with countdown display; automatic stop at end of set time.
  • Accessory Mounting: Pressure-mounted accessory system for secure fit of the 96-well microplate adapter and other tube adapters.
  • Stability: Rubber suction feet provide secure benchtop placement.
  • Portability: Compact footprint (160 × 146 × 115 mm) and moderate weight (3.4 kg).
  • Maintenance: Brushless DC motor eliminates routine brush replacement.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards.
  • Safety Features: Enclosed motor with thermal protection; sealed housing prevents liquid ingress; rubber suction feet prevent movement.
  • Electrical Safety: Low-voltage DC motor (24V input); universal voltage power supply (100-240V, 50/60Hz) with over-current protection.
  • Noise Control: Low-noise operation minimizes distractions.
  • GLP Compliance: Digital timer and speed display support GLP documentation.
  • Protection Class: IP21 rating (protection against solid objects >12mm and vertical dripping water).

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture.
  • Cleaning: Wipe exterior with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; disconnect power before cleaning.
  • Inspection: Inspect power cord and adapters for damage before each use; check rubber feet for wear.
  • Operation (Microplate): Secure the 96-well microplate into the appropriate adapter using pressure mounting; ensure it is firmly seated. Select continuous operation mode and set the desired speed and time.
  • Operation (Tubes): For touch mode, press the tube firmly into the cup head until the motor activates. For continuous mode, use the switch/power control.
  • Speed Selection: Start at low speed (100-500 rpm) and increase gradually to prevent splashing.
  • Spill Management: If liquid spills onto the unit, disconnect power immediately, clean thoroughly, and allow to dry before reuse.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Digital variable-speed mixing of 96-well microplates (for ELISA and immunoassays), blood collection tubes, reagents, and biological samples for clinical chemistry, molecular diagnostics, and research applications.
  • Clinical Role: Essential mixing equipment in clinical diagnostic laboratories, immunology laboratories, molecular diagnostics labs, blood banks, and pharmaceutical research facilities.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Disconnect power before cleaning; do not immerse the unit in liquid; keep the power cord away from heat sources.
  • Spill Protection: Use appropriate caps or seals for tubes and microplates to prevent sample leakage; clean spills immediately.
  • Microplate Security: Ensure the 96-well microplate is securely seated in its adapter before starting the mixer to prevent it from dislodging.
  • Speed Selection: Start at low speed (100-500 rpm) and increase gradually to prevent splashing or sample loss from the microplate wells.
  • Timer Use: Set the appropriate time for the mixing protocol; do not exceed recommended mixing times for sensitive samples.
  • Training: Only trained laboratory personnel should operate the MX-S+ for clinical diagnostic applications.

2. FIRST AID MEASURES

  • Sample Splash: If a biological sample splashes into the eyes, flush with water for 15 minutes and seek medical attention; if on the skin, wash with soap and water.
  • Electrical Malfunction: If the unit shows signs of electrical malfunction (smoke, burning smell), disconnect the power immediately; do not attempt to operate it; contact service personnel.
  • Chemical Spill: If corrosive chemicals spill on the unit, wipe them off immediately with an appropriate neutralizer, and dry thoroughly before reconnecting the power.

3. FIRE FIGHTING MEASURES

  • Flammability: The plastic housing and electrical components may burn.
  • Extinguishing Media: Use carbon dioxide (CO₂) or a dry chemical extinguisher for electrical fires.
Fire Response: Unplug the unit immediately; do not use water on an electrical fire.