Pro Large Multifunctional 3D Shaker (SK-D3309-)

WhatsApp Order
The Pro Large Multifunctional 3D Shaker (SK-D3309-) is a digital, high-capacity laboratory rocker featuring a gentle three-dimensional wave-like motion at a fixed 9° tilt angle . Designed for heavy-duty applications, this unit supports a maximum load capacity of 5kg (including clamps), making it ideal for processing large volumes of samples . Key features include dual independent LCD displays for precise monitoring of speed (10-70 rpm) and time (1 minute to 19 hours 59 minutes), a robust DC motor, and compatibility with cold rooms and incubators (5-40°C) .
For the clinical laboratory scientist and molecular biologist, the Pro Large Multifunctional 3D Shaker (SK-D3309-) is essential for genomic and proteomic workflows . It provides consistent, low-foam agitation for polyacrylamide gel staining and destaining, ensuring high-quality band resolution . It also offers the gentle, even flow required for membrane washes in Western Blotting and Southern/Northern Blotting, preventing damage to delicate membranes .
With universal voltage (100-240V) and advanced safety features including overload protection and an IP21 rating, this unit provides reliable, reproducible results for immunoprecipitation, cell culture, and general liquid mixing, supporting vital patient diagnostics across molecular and cell biology applications .
Description

Pro Large Multifunctional 3D Shaker (SK-D3309-)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Gentle 3D Agitation for Biological and Biochemical Reactions
  • Primary Use: Provides a digital large multifunctional 3D shaker with a gentle three-dimensional wave-like motion at a fixed 9° tilt angle, ideal for homogenously mixing samples in tubes, flasks, and microplates for cell culture, hybridization, and biochemical assays .
  • How it helps: For the clinical laboratory scientist and researcher, the Pro Large Multifunctional 3D Shaker (SK-D3309-) smooth 3D gyratory motion ensures uniform reagent distribution without causing shear stress or foam formation—critical for maintaining the integrity of delicate biological samples and cell cultures . For the patient undergoing diagnostic testing, this gentle yet effective mixing guarantees reproducible assay conditions, leading to accurate results that guide treatment decisions .
2. Electrophoresis Gel Staining and Destaining
  • Primary Use: Used for even distribution of stains and destaining solutions onto agarose and polyacrylamide gels, ensuring consistent background clearance and band visualization for molecular diagnostics .
  • How it helps: For the molecular biologist, the 10-70 rpm speed range and programmable timer (1 minute to 19 hours 59 minutes) allow automated, reproducible dye distribution—reducing operator-dependent variability and improving band resolution . For the patient undergoing genetic testing, clear and consistent gel results support accurate diagnosis of genetic disorders or infectious diseases .
3. Membrane Hybridization and Immunoblotting
  • Primary Use: Supports uniform mixing and incubation protocols for membrane hybridization (Southern/Northern blot), Western blotting, and immunoprecipitation, ensuring complete and even coverage of reagents .
  • How it helps: For the immunology technologist, the 9° tilt angle and 5kg load capacity allow for gentle yet thorough washing and antibody incubation of blotting membranes, effectively reducing background noise and enhancing signal specificity . For the patient, this ensures high sensitivity in confirmatory testing for conditions like HIV, Lyme disease, or autoimmune markers .
4. Large-Capacity Sample Processing for High Throughput
  • Primary Use: Features a 330 × 330 mm platform with a maximum load capacity of 5kg (including clamps), capable of shaking multiple flasks, culture dishes, and multi-well plates simultaneously .
  • How it helps: For the laboratory manager, the high capacity allows for batch processing of multiple patient samples or large volume cultures, significantly improving workflow efficiency and reducing manual handling time . For the patient, batch processing reduces turnaround times for critical results, enabling faster clinical decision-making .
5. Cold Room and Incubator Compatibility
  • Primary Use: Designed to operate reliably within an ambient temperature range of 5-40°C and 80% relative humidity, making it compatible for use in cold rooms and standard incubators .
  • How it helps: For the clinical researcher, this wide operating range allows the shaker to be placed directly in temperature-controlled environments for temperature-sensitive applications (e.g., hybridizations, cell culture) without loss of function . For the patient, maintaining precise thermal conditions during sample processing preserves sample integrity, supporting accurate diagnostic results .

SECONDARY & SUPPORTIVE USES


1. Cell Culture Maintenance: Supports gentle mixing for flasks and culture bottles, ensuring uniform distribution of nutrients and gases for optimal cell growth .
2. Immunoprecipitation and Protein Extraction: Used for gentle mixing in immunoprecipitation protocols and protein extraction workflows requiring consistent, gentle agitation .
3. Liquid-Solid Suspension Homogenization: Used for mixing of cell pellets, tissue homogenates, and other liquid-solid suspensions in molecular preparation workflows.
4. ELISA Plate Incubation: Supports uniform mixing during ELISA plate incubation steps, reducing well-to-well variability in diagnostic immunoassays .
5. Microbial Culture and Fermentation: Used for mixing bacterial and yeast cultures in flasks, ensuring uniform growth conditions and consistent cell density .
6. Clinical Sample Preparation: Supports mixing of serum, plasma, and other biological fluids for clinical chemistry and immunoassay sample preparation.
7. Blotting Membrane Washing: Supports uniform washing of Western, Southern, and Northern blot membranes, reducing background noise and improving signal specificity .
8. DNA/RNA Hybridization Reactions: Used for uniform mixing in hybridization protocols for nucleic acid research and molecular diagnostics.
9. Pharmaceutical Quality Control: Used for mixing of QC samples and reagents in pharmaceutical testing laboratories requiring gentle, uniform agitation .
10. Research and Academic Laboratories: Provides versatile 3D mixing for diverse research applications in cell biology, molecular biology, and biochemistry .
11. Veterinary Diagnostic Laboratory: Supports mixing of biological specimens for animal health testing and infectious disease diagnosis .
12. Chromogenic Substrate Development: Used in ELISA and immunohistochemistry workflows for consistent chromogenic substrate development across multiple samples.
13. Microplate Assay Development: Supports uniform mixing in 96-well and 384-well microplate assays for drug discovery and biomarker screening .
14. University and Educational Laboratory Training: Provides versatile 3D mixing for teaching laboratory techniques in undergraduate and graduate science courses .
15. Compatibility with RS232 & Software: Connect to a computer via RS232 interface for data transfer; free Shaker PC software allows real-time display of working curves on a computer .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A large multifunctional digital 3D shaker (three-dimensional rocker) with gentle wave-like motion, designed for blotting, hybridization, cell culture, and general mixing applications in clinical and research laboratories .
  • Designation: SK-D3309-Pro Large Multifunctional 3D Shaker, LCD Digital 3D Laboratory Shaker, Multifunctional 3D Rocker, DLAB SK-D3309-Pro .
  • Key Components:
    • Motion Type: Three-dimensional (3D) gyratory rocking motion .
    • Work Platform: Large 300×285mm loadable platform with anti-slip silicone surface; supports optional clamps for flasks .
    • Tilt Angle: Fixed 9° angle for gentle, wave-like agitation .
    • Display: Dual independent LCD displays for simultaneous viewing of speed and timer .
    • Control: Digital control with knob/touchpad; programmable timer .
    • Motor: DC motor (40W Input / 24W Output) .
    • Interface: RS232 port for computer connectivity and data export .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Tilt Angle: 9° (fixed) .
  • Speed Range: 10-70 rpm (variable, adjustable) .
  • Maximum Load Capacity: 5 kg (including clamps/accessories) .
  • Operating Modes: Timed operation and Continuous operation .
  • Timer Range: 1 minute to 19 hours 59 minutes (1-1199 minutes) .
  • Timer Display: LCD Digital .
  • Speed Display: LCD Digital .
  • Motor Type: DC motor .
  • Motor Rating Input: 40W .
  • Motor Rating Output: 24W .
  • Total Power: 50W .
  • Voltage/Frequency: 100-240V, 50/60Hz (universal voltage) .
  • Work Platform Dimensions (W × D): 300 × 285 mm .
  • External Dimensions (W × D × H): 360 × 430 × 106 mm . (Alternative 430×360×106mm) .
  • Weight: 9 kg .
  • Operating Temperature: 5-40°C (cold room and incubator compatible) .
  • Permissible Ambient Humidity: ≤80% RH .
  • Protection Class: IP21 .
  • Interface: RS232 .
  • Compatibility: Suitable for flasks, culture dishes, Petri dishes, centrifuge tubes, microplates, and blotting containers with various optional clamps .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Impact-resistant, sturdy housing with non-slip base for stable benchtop placement; designed for heavy loads up to 5kg .
  • Work Platform: Anti-slip silicone disc surface (or detachable rubber mat) that securely holds vessels in place, preventing sliding during operation; supports optional universal clamp kits for flasks .
  • Motion Type: 3-dimensional rocking/nutating motion at fixed 9° tilt angle, creating a smooth wave-like action for gentle, uniform mixing .
  • Display: Dual independent LCD screens providing clear, real-time visibility of both agitation speed (rpm) and run time .
  • Control System: Digital control interface with timer; programmable timer with automatic stop function .
  • Noise Level: Silent direct-drive DC motor ensures quiet operation suitable for distraction-free laboratory environments .
  • Operating Conditions: Can be used in cold rooms (5°C) and incubators (up to 40°C, 80% RH) .
  • Data Export: RS232 interface allows connection to a computer for data transfer; free PC software available for real-time monitoring of working curves .
  • Portability: Moderate weight (9kg) for sturdy benchtop placement.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards .
  • Safety Features: Automatic shutdown in case of overload or detected fault; IP21 protection rating (protection against solid objects >12mm and vertical dripping water); secure platform fixation prevents vessel slippage .
  • Electrical Safety: Universal voltage (100-240V, 50/60Hz) for international use; 50W low power consumption; earthed power connection recommended .
  • Motor Type: DC motor provides stable operation and low noise .
  • Timer Safety: Programmable timer with automatic stop prevents over-mixing of sensitive samples .
  • Certifications: CE marked; cTUVus approved .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on a clean, dry, level benchtop; protect from dust and moisture.
  • Cleaning: Wipe the work platform and housing with a soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; disconnect power before cleaning .
  • Inspection: Inspect the power cord for damage before each use; check the work platform for residue or wear; verify stability of benchtop placement .
  • Operation: Place the unit on a safe, stable surface; ensure operating voltage matches the power supply; connect the power cable; switch ON the instrument .
  • Speed Setting: Rotate speed control to set speed (10-70 rpm); LCD display shows current speed setting .
  • Timer Setting: Use timer controls to set run time (1-1199 minutes); LCD display shows current time setting; unit automatically halts when the timer reaches zero .
  • Load Balancing: Distribute vessels evenly across the work platform; do not exceed the maximum load capacity (5 kg) .
  • Spill Management: If liquid spills onto the unit, disconnect power immediately, clean thoroughly, and allow to dry before reuse.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Gentle, uniform 3D mixing for gel staining/destaining, Western blotting, Southern/Northern blotting, immunoprecipitation, cell culture, hybridization reactions, and general sample mixing in clinical diagnostic, molecular biology, and research laboratories .
  • Clinical Role: Essential mixing equipment in clinical diagnostic laboratories, molecular biology labs, immunology laboratories, cell culture facilities, pharmaceutical research laboratories, and academic research institutions.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Disconnect power before cleaning; do not immerse the unit in liquid; keep the power cord away from heat sources .
  • Load Limits: Do not exceed maximum load capacity (5 kg); ensure load is evenly distributed across the work platform to prevent imbalance .
  • Spill Protection: Use appropriate vessel caps or seals to prevent sample leakage; clean spills immediately .
  • Cold Room/Incubator Use: Ensure the instrument is placed on a stable surface within the cold room or incubator; operating temperature range is 5-40°C .
  • Timer Use: Set appropriate time for the mixing protocol; do not exceed recommended mixing times for sensitive samples .
  • Accessory Installation: Ensure clamps or platform accessories are securely attached before loading samples .
  • Training: Only trained laboratory personnel should operate the SK-D3309-Pro for clinical diagnostic applications.

2. FIRST AID MEASURES

  • Sample Splash: If a biological sample splashes into the eyes, flush with water for 15 minutes and seek medical attention; if on the skin, wash with soap and water .
  • Electrical Malfunction: If the unit shows signs of electrical malfunction (smoke, burning smell), disconnect the power immediately; do not attempt to operate it; contact service personnel .
  • Mechanical Failure: If the unit fails to operate or makes abnormal noise, disconnect the power, check for obstruction, and contact service if the issue persists .
  • Chemical Spill: If corrosive chemicals spill on the unit, wipe them immediately with an appropriate neutralizer, and dry thoroughly before reconnecting the power .

3. FIRE FIGHTING MEASURES

  • Flammability: The plastic housing and electrical components may burn .
  • Extinguishing Media: Use carbon dioxide (CO₂) or a dry chemical extinguisher for electrical fires .
  • Fire Response: Unplug the unit immediately; do not use water on an electrical fire .