Stainless Steel Temperature Electrode (DTEMP-02H)

WhatsApp Order
The Stainless Steel Temperature Electrode (DTEMP-02H) is a dedicated ATC (Automatic Temperature Compensation) probe designed for use with DLAB portable pH, ORP, and multi-parameter meters such as the DORP10 and DPO10 series . Featuring a rugged stainless steel housing (Φ5 × 120mm), a built-in 10KΩ thermistor, and a 1-meter cable, it is engineered to provide highly accurate (ΔT = ±0.2°C) and fast temperature readings across a range of 0 to 110°C .
For the clinical laboratory scientist, the Stainless Steel Temperature Electrode (DTEMP-02H) is crucial for performing Automatic Temperature Compensation (ATC) during pH or ORP measurement. Fluctuations in sample temperature directly affect electrode slope and liquid junction potential; this probe supplies live temperature data to the meter, allowing it to mathematically correct the raw millivolt signal to a standardized temperature value.
For the patient, the use of ATC technology ensures that diagnostic results (such as the accuracy of buffer solutions or the stability of biological fluids) are reliable and reproducible, eliminating errors caused by ambient temperature changes. The durable stainless-steel construction ensures longevity in busy clinical and industrial environments.
Description

Stainless Steel Temperature Electrode (DTEMP-02H)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Automatic Temperature Compensation (ATC) for pH and ORP Measurements
  • Primary Use: Provides a stainless steel temperature electrode designed for automatic temperature compensation (ATC) during pH and ORP measurements, ensuring accurate readings by correcting for temperature-dependent variations in electrode response .
  • How it helps: For the clinical laboratory scientist and medical technologist, the Stainless Steel Temperature Electrode (DTEMP-02H) works in conjunction with pH or ORP meters to automatically adjust measurements based on the sample temperature (ΔT). This eliminates the need for manual temperature correction, reducing calculation errors and improving the reproducibility of diagnostic testing . For the patient, proper ATC ensures that pH readings of biological fluids (such as blood, plasma, or urine) are accurate, supporting the correct diagnosis and management of metabolic conditions, acid-base imbalances, and electrolyte disorders.
2. High-Accuracy Temperature Measurement for Biological Samples
  • Primary Use: Measures temperature of liquid samples (including biological fluids, buffers, and reagents) across a range of 0-110 with a precision of ±0.2, using a built-in 10KΩ thermistor sensor .
  • How it helps: For the clinical laboratory scientist and quality control officer, the electrode’s high accuracy (ΔT = ±0.2°C) and rapid response are essential for verifying environmental conditions during analytical runs. It ensures that reagents stored at suboptimal temperatures are not used, or that incubations are performed at the correct temperature to maintain enzyme activity. For the patient, precise temperature measurement prevents false results caused by thermal degradation of sensitive biomarkers in diagnostic kits.
3. Durable Stainless Steel Construction for Laboratory Durability
  • Primary Use: Features a rugged stainless steel housing (Φ5mm × 120mm) and a flexible 1-meter cable, offering high resistance to corrosion and physical damage from frequent handling in busy clinical environments .
  • How it helps: For the laboratory manager and bench technician, the stainless steel build ensures the electrode resists breakage and chemical attack from salts, aqueous solutions, and buffers. This durability reduces replacement frequency and equipment downtime, ensuring that temperature monitoring is always available for quality control protocols. For the patient, robust equipment ensures consistent quality control and sample processing without interruptions due to equipment failure.

SECONDARY & SUPPORTIVE USES

1. Quality Control of Temperature-Sensitive Reagents: Monitors the temperature of reagents (e.g., enzymes, antibodies, or substrates) during thawing and preparation to ensure they remain within safe thermal limits.
2. Water Quality and Environmental Testing: Measures temperature of purified water, dialysis water, and aqueous samples in hospital environmental monitoring programs to verify compliance with standards .
3. Temperature Verification in Incubators and Water Baths: Used to spot-check the temperature accuracy of laboratory equipment such as incubators, heating blocks, and water baths.
4. Monitoring of Industrial and Pharmaceutical Processes: Supports temperature monitoring in pharmaceutical compounding, bioprocessing, and chemical reaction monitoring (reaction temperature control) in R&D labs .
5. Research and Academic Laboratories: Serves as a general-purpose temperature probe for any aqueous solution in research settings, including teaching labs.
6. Electrode Compatibility Testing: Used with various pH/ORP meters to verify electrode and meter functionality, ensuring the temperature sensing circuit is operational.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A stainless steel temperature electrode used primarily for Automatic Temperature Compensation (ATC) in conjunction with pH and ORP meters .
  • Designation: Stainless Steel Temperature Electrode, ATC Probe, Temperature Sensor .
  • Key Components:
o Electrode Housing: Stainless steel (SS) casing, dimensions Φ5mm × 120mm .
o Temperature Sensor : Built-in 10KΩ thermistor (NTC type) .
o Cable: Length 1 meter .
o Electrical Interface: 4-core connection for stable data transmission .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Measurement Range (Liquid): 0 – 110 °C .
  • Accuracy: ±0.2 °C .
  • Resolution: 0.1 °C .
  • Housing Material: Stainless Steel .
  • Cable Length: 1.0 meter .
  • Connector Type: 4-core plug / Mini-DIN (compatible with DLAB portable meters) .
  • Compatibility: DORP10, DPO10, PO10 Portable Meters and similar pH/ORP analyzers .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Rugged, fully sealed stainless steel shaft for high durability and chemical resistance.
  • Operation: Simple immersion; ensure the probe tip is fully submerged in the sample.
  • Maintenance: Wipe clean with a soft cloth; rinse with distilled water after use; no electrolyte refilling required.
  • Portability: Small footprint and long cable allow for use in laboratory beakers or field sample collection.
  • Sterilization: Wipe down with 70% ethanol or mild disinfectants; do not autoclave.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: Standard laboratory accessory for diagnostic equipment (used in IVD workflows).
  • Electrical Safety: Low-voltage passive sensor; safe for use with standard laboratory meters.
  • Chemical Resistance: Stainless steel resists corrosion from salts and mild acids/bases; avoid strong mineral acids.
  • Waterproof Rating: The electrode itself is resistant to immersion.

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store in a clean, dry place at room temperature. Do not bend the probe shaft.
  • Cleaning: Rinse with distilled water after each use to remove reagent or sample residue. Wipe dry with a soft cloth.
  • Inspection: Inspect the cable for cuts or damage before use. Check the metal shaft for pitting or corrosion.
  • Cable Care: Do not sharply bend or crimp the cable, as this can damage the internal wiring.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Automatic temperature compensation (ATC) for precise pH/ORP measurements; general temperature measurement of aqueous solutions in clinical chemistry, pharmaceutical QC, and water testing .
  • Clinical Role: Essential accessory for portable pH/ORP meters used in hospital labs, blood gas analysis support, and environmental monitoring of water treatment systems .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Do not immerse the connector end of the cable in liquid. Keep the plug dry.
  • Handling: The stainless steel shaft is durable but can be bent under extreme force; handle with care.
  • Cleaning: Do not use abrasive cleaners or metal brushes on the sensor, as this may scratch the surface and affect thermal conductivity.
  • Training: Assist trained laboratory personnel in verifying temperature readings against certified thermometers for QA purposes.

2. FIRST AID MEASURES

  • Sample Splash: If sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
  • Sharp Edges: Although polished, the metal tip could cause minor cuts if handled improperly.

3. FIRE FIGHTING MEASURES

  • Flammability: The cable insulation is plastic and combustible; the metal shaft is non-flammable.
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires involving the cable.