Pen Meter (DORP1)
WhatsApp Order
The Pen Meter (DORP1) is a pocket-sized, single-parameter pen tester measuring Oxidation-Reduction Potential (ORP) from -1000.0 mV to +1000.0 mV with accuracy of ±0.1% F.S. ±1 digit and resolution of 0.1/1 mV, featuring replaceable combined electrode design (DORP1-S), multi-color backlit LCD display with reading stability indicator and auto data lock, IP67 dustproof/waterproof rating, 0-60℃ temperature measurement with ±0.2℃ accuracy, 1 point automatic calibration with 222 mV ORP standard, support for CH/USA/NIST standard buffer solutions, low battery indicator, user-configurable auto shut-off and backlight duration, and complete field-ready kit including hard carrying case, ORP standard solution (222 mV, 30mL), 3 mol KCl electrode storage solution (10mL), sample vial (30mL), 4 AAA batteries, and lanyard—ideal for water quality testing in clinical, pharmaceutical, and environmental applications .
For the dialysis technician, infection control officer, and water quality specialist, the DORP1 enables rapid, on-site ORP measurement to verify disinfection efficacy in purified water systems, dialysis fluids, and pharmaceutical process water—critical parameters for ensuring patient safety during renal replacement therapy and drug manufacturing . The replaceable electrode design extends instrument service life, while the IP67 rating ensures reliable operation in harsh field environments .
Key features include multi-color backlit display with reading stability indicator and auto data lock when stable (smiley icon), function, low battery indicator, user-configurable auto shut-off time and backlight duration, and compatibility with CH, USA, and NIST calibration standards . The DORP1+ variant adds Bluetooth connectivity for wireless connection to mobile APP with two-way control, unlimited data storage, graphical display modes (chart, curve, dial, normal), calibration reminders, measurement object ID management, and timed storage .
For the patient, accurate ORP monitoring of water used in dialysis and pharmaceutical manufacturing ensures that critical treatment fluids meet stringent safety and quality standards—preventing potential harm from improperly treated water and supporting the production of safe, effective medications.
Description
Pen Meter (DORP1)
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Disinfection Efficacy Monitoring in Dialysis Water Systems
-
Primary Use: Provides a pocket-sized, single-parameter pen meter that measures Oxidation-Reduction Potential (ORP) from -1000.0 mV to +1000.0 mV with accuracy of ±0.1% F.S. ±1 digit, specifically designed for assessing the oxidizing power of disinfection processes in water treatment systems .
-
How it helps: For infection control officers and dialysis technicians, the DORP1 pen meter enables rapid, on-site verification of ORP levels in purified water loops, dialysis water systems, and hospital plumbing—directly confirming that disinfection processes are actively combating microbial growth. The multi-color backlit display ensures easy reading in various lighting conditions, while the IP67 dustproof/waterproof rating allows for use in demanding utility environments . For the patient, accurate ORP monitoring ensures that water used in renal replacement therapy is free from harmful microorganisms, meeting critical safety standards for dialysis treatment.
2. Water Quality Verification for Pharmaceutical Manufacturing
-
Primary Use: Used to measure ORP levels in pharmaceutical process water, purified water systems, and water-for-injection (WFI) loops to verify oxidation-reduction status and ensure water quality compliance .
-
How it helps: For the pharmaceutical QA/QC chemist and water quality specialist, the DORP1 provides portable ORP measurement with 0.1/1 mV resolution and automatic temperature compensation across 0-60°C range. The replaceable electrode design (DORP1-S) extends instrument service life, while the reading stability indicator and auto data lock ensure accurate, reproducible measurements . For the patient, rigorous ORP monitoring of pharmaceutical water systems helps ensure that medications and IV solutions meet stringent purity standards, supporting product safety.
3. Antioxidant and Redox Status Assessment
-
Primary Use: Measures the oxidation-reduction potential of aqueous solutions, providing information about the total oxidizing or reducing capacity of water samples in healthcare and research applications .
-
How it helps: For the clinical laboratory scientist and researcher, the DORP1 enables rapid assessment of redox status in various aqueous matrices, supporting studies on oxidative stress, water treatment efficacy, and chemical reaction monitoring. The Bluetooth-compatible variant (DORP1+) allows wireless data transfer to mobile APP with unlimited storage, calibration reminders, and sample ID management . For the patient, redox status monitoring of water used in medical device processing and pharmaceutical manufacturing helps ensure product quality and safety.
4. Field and Utility Water Testing
-
Primary Use: Pocket-sized pen design with IP67 dustproof/waterproof rating supports on-site ORP measurement in diverse locations including cooling towers, boiler feed water, wastewater discharge points, and environmental monitoring sites .
-
How it helps: For hospital facility engineers and environmental safety officers, the DORP1’s portable, battery-operated design (4 × AAA batteries) allows for convenient spot-checking of water quality at various points in hospital water distribution systems. The bundled hard carrying case, ORP standard solution (222 mV, 30mL), and electrode storage solution provide complete field-ready capability . For the patient and community, consistent monitoring of hospital water systems helps prevent healthcare-associated infections and ensures environmental compliance.
SECONDARY & SUPPORTIVE USES
1. Disinfection Control in Hydrotherapy and Spa Pools: Monitors ORP levels in hospital hydrotherapy pools, aquatic therapy centers, and spas to ensure chlorine or other oxidizers remain at effective concentrations for microbial control.
2. Cooling Tower and Boiler Water Testing: Measures ORP in cooling towers, boiler feed water, and steam generation systems to assess corrosion potential and treatment efficacy.
3. Wastewater Treatment Monitoring: Assesses ORP levels in hospital wastewater treatment systems to evaluate aeration efficiency and treatment process performance.
4. Environmental and Surface Water Monitoring: Portable pen format is ideal for field studies measuring ORP in natural water bodies to assess ecosystem health and pollution levels.
5. Pharmaceutical Process Validation: Supports ORP measurement for validation and routine monitoring of pharmaceutical water systems and cleaning validation protocols.
6. Research and Academic Laboratories: Serves as a portable ORP testing tool for research applications in redox chemistry, environmental science, and water quality studies.
7. Food and Beverage Quality Control: Verifies ORP levels in process water, cleaning solutions, and product formulations in hospital nutrition services and food safety testing.
8. Aquaculture and Zebrafish Facility Management: Monitors ORP in aquatic animal housing facilities within research institutions to ensure optimal environmental conditions.
9. Educational and Laboratory Training: Serves as a teaching tool for demonstrating ORP measurement principles in medical technology and clinical laboratory science training programs.
10. Chlorine and Oxidizer Concentration Verification: Provides rapid assessment of oxidizing agent effectiveness in disinfection systems by measuring ORP as a surrogate for available chlorine.
11. Electrode Replacement Compatibility: Uses replaceable DORP1-S electrode design, extending instrument service life and allowing continued use when the original probe reaches end of life .
12. Bluetooth Data Management (DORP1+ Model): Supports wireless connection to mobile APP for two-way control, unlimited data storage, graphical display modes, calibration reminders, sample ID management, and timed storage .
13. Multi-Standard Calibration: Provides CH, USA, and NIST standard buffer solution options for flexible calibration based on regional requirements .
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A pocket-sized, single-parameter pen meter (pen tester) measuring Oxidation-Reduction Potential (ORP) and temperature, with replaceable combined electrode design, multi-color backlit LCD display, and IP67 dustproof/waterproof rating .
-
Designation: DORP1 Pen Meter, DORP1 Pen Tester, Pocket ORP Meter, DLAB ORP Pen Meter .
-
Key Components:
-
Instrument Meter: Pocket-sized pen housing with multi-color backlit LCD display, IP67 dustproof/waterproof rating, and low battery indicator .
-
ORP Electrode: Replaceable combined probe (DORP1-S, pre-installed) with platinum sensing elements .
-
ORP Standard Solution: 222 mV ORP calibration standard, 30mL .
-
Electrode Storage Solution: 3 mol KCl ORP electrode soaking solution, 10mL .
-
Sample Vial: 30mL sample vial for convenient sample collection and testing .
-
Power Supply: 4 × 1.5V AAA alkaline batteries (pre-installed) .
-
Accessories: Hard carrying case (28.0×23.0×8.2 cm), lanyard, instruction manual .
-
Bluetooth Variant (DORP1+): Adds Bluetooth connectivity, mobile APP support, advanced data management, calibration reminders, sample ID management, and timed storage .
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Measurement Parameter: mV (ORP) and Temperature (℃/℉) .
-
ORP Measurement Range: (-1000.0 ~ +1000.0) mV .
-
ORP Resolution: 0.1 / 1 (selectable) .
-
ORP Accuracy: ±0.1% F.S. ± 1 digit .
-
Temperature Measurement Range: 0~60℃ (32~140°F) .
-
Temperature Accuracy: ±0.2℃ .
-
Display: Multi-color backlit LCD display; display mode changes color based on measurement status; reading stability indicator; auto data lock when stable .
-
Calibration: Supports 1 point ORP calibration; compatible with CH, USA, NIST standard buffer solutions .
-
User Settings: Customizable auto shut-off time; adjustable backlight duration; low voltage indicator; .
-
Protection Class: IP67 (dustproof and waterproof against temporary immersion) .
-
Operating Conditions: 0~60℃; suitable for field and laboratory use .
-
Power: 4 × AAA alkaline batteries (pre-installed); user replaceable; low battery indicator .
-
Dimensions (Carrying Case): 28.0 × 23.0 × 8.2 cm .
-
Electrode Compatibility: Replaceable combined probe (DORP1-S) .
-
Bluetooth Features (DORP1+): Two-way control, unlimited data storage, graphical display modes (chart, curve, dial, normal), calibration reminders, measurement object ID management, timed storage, user-friendly UI .
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: Pocket-sized, ergonomic pen-style handheld design with replaceable combined probe; IP67 dustproof/waterproof rating for field use .
-
Display: Multi-color backlit LCD display; screen color changes based on measurement status and data stability; .
-
User Interface: Simple operation; short press to power on; long press to enter calibration; reading stability indicator (smiley icon) confirms stable measurement; auto data lock automatically locks readings when stable .
-
Calibration: Supports 1 point automatic ORP calibration; rinse electrode in pure water, submerge in calibration solution (222 mV ORP standard), wait for stability indicator, confirm calibration .
-
Measurement Mode: Single parameter ORP measurement; displays ORP in mV and temperature in ℃/℉ simultaneously .
-
Data Locking: Auto-hold function automatically locks readings when stability indicator confirms stable measurement; short press to release auto-hold .
-
Replaceable Electrode: Combined probe design allows electrode replacement (DORP1-S) to extend instrument service life .
-
Bluetooth Operation (DORP1+): Supports wireless connection to mobile APP for two-way control, data transfer, and advanced data management.
-
APP Display Modes (DORP1+): Provides multiple display modes (graph, curve, dial, normal) for different data visualization preferences .
-
Portability: Compact pocket-sized design with hard carrying case for safe transport and storage; lanyard included for convenient carrying .
-
Power Management: Low voltage indicator alerts when batteries need replacement; user-configurable auto shut-off and backlight duration to conserve battery life .
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: In Vitro Diagnostic (IVD) preparatory equipment; laboratory water quality testing instrument .
-
Safety Certifications: Manufactured under ISO 9001:2015 quality management system; CE compliant .
-
Protection Class: IP67 (dustproof and waterproof against temporary immersion up to 1 meter for 30 minutes), suitable for harsh field environments .
-
Electrical Safety: Low-voltage operation with 4 × AAA batteries (1.5V each); safe for use in laboratory and field environments.
-
Material Safety: Plastic housing with replaceable combined probe; platinum sensing elements for ORP measurement; RoHS compliant materials.
-
Calibration Compliance: Supports CH, USA, NIST standard buffer solutions for region-specific calibration requirements .
-
GLP Compliance (DORP1+): APP supports calibration reminders, measurement object ID management, timed storage, and unlimited data storage for quality documentation .
-
Bluetooth Security (DORP1+): Bluetooth connection requires pairing; secure data transfer; APP supports user authentication.
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store the meter in its hard carrying case in a clean, dry environment; protect from extreme temperatures and direct sunlight; remove batteries for long-term storage.
-
Cleaning: Rinse the ORP electrode with distilled water after each use; wipe the meter body with a soft, damp cloth using a mild detergent; do not submerge the meter body beyond the IP67 rating limits; for the platinum sensing element, avoid touching or scrubbing with abrasive materials.
-
Inspection: Inspect the electrode for damage or contamination before each use; check the platinum sensing element for integrity; verify calibration before critical measurements.
-
Operation: Remove the protective cap; power on by short pressing the power button; rinse electrode with distilled water; immerse electrode in sample, stir gently; wait for stability indicator (smiley icon); read stabilized value; auto data lock will lock readings when stable .
-
Calibration: Calibrate before first use or when measurement errors are suspected; rinse electrode in pure water, submerge in ORP calibration standard (222 mV), shake gently, let stand; wait for stability indicator, then confirm calibration .
-
Electrode Storage: Store electrode with protective cap in place; keep electrode moist using 3 mol KCl ORP electrode soaking solution to prevent drying; never store dry .
-
Electrode Hydration: If electrode has dried out, soak in 3 mol KCl storage solution for 24-48 hours before use; recalibrate before use.
-
Battery Replacement: Replace batteries when low voltage indicator appears; use 4 × AAA alkaline batteries (1.5V each); ensure correct polarity when installing new batteries.
-
APP Setup (DORP1+): Download the DLAB mobile APP, follow the to connect via Bluetooth, configure measurement parameters, and enable data storage functions .
-
Spill Management: If liquid spills onto the meter, wipe immediately with a soft, dry cloth; despite IP67 rating, avoid prolonged immersion.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Portable ORP measurement for disinfection efficacy monitoring in dialysis water systems, pharmaceutical water quality verification, cooling tower and boiler water testing, wastewater treatment monitoring, and environmental water quality assessment .
-
Clinical Role: Essential water quality testing instrument for dialysis units, hospital engineering departments, infection control, pharmaceutical quality control laboratories, and environmental monitoring programs requiring rapid on-site ORP assessment.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Electrical Safety: Do not immerse the meter beyond the IP67 rating limits; avoid immersion in liquids other than water samples; ensure battery compartment is properly sealed before use.
-
Electrode Handling: The platinum sensing element is delicate; do not touch or scrub with abrasive materials; inspect the sensing element before each use for damage.
-
Electrode Storage: Always store electrode with protective cap in place; keep electrode moist using 3 mol KCl storage solution; never store dry; dried electrodes require rehydration before use .
-
Calibration Verification: Calibrate daily or before critical use using fresh ORP calibration standard (222 mV) .
-
Sample Compatibility: Rinse electrode thoroughly with distilled water between different samples to prevent cross-contamination; ensure there are no air bubbles trapped on the electrode surface during measurement.
-
Battery Safety: Use only AAA alkaline batteries; do not mix old and new batteries; remove batteries for long-term storage to prevent leakage; dispose of used batteries properly.
-
Environmental Protection: Dispose of calibration standards, sample vials, and other consumables according to local environmental regulations; ORP standard solution (222 mV) contains salts and may be disposed of via standard laboratory waste streams.
-
Bluetooth Security (DORP1+): Ensure Bluetooth connection is secure; use APP password protection if available; do not leave APP open on shared devices without logging out .
-
Data Backup (DORP1+): Regularly export data from APP to secure storage to prevent data loss in case of mobile device failure.
-
Training: Only trained laboratory personnel should operate the DORP1 Pen Meter for water quality testing applications.
2. FIRST AID MEASURES
-
Calibration Standard Exposure: If ORP calibration standard (222 mV solution) splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
-
Sample Splash: If biological or chemical sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
-
Electrical Malfunction: If the meter shows signs of electrical malfunction (erratic readings, display issues, battery leakage), remove batteries immediately; do not attempt to operate; contact service personnel.
-
Electrode Damage: If the platinum sensing element is damaged, discontinue use; replace the electrode with a new DORP1-S probe.
-
Battery Leakage: If battery leakage occurs, remove batteries immediately, clean the battery compartment with a dry cloth, dispose of batteries properly; avoid skin contact with leaked electrolyte.
3. FIRE FIGHTING MEASURES
-
Flammability: The plastic housing, cable, and carrying case are combustible; may melt or burn if exposed to flame or high heat.
-
Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for fires involving plastic components.
-
Fire Response: Remove batteries if safe to do so; do not use water on electrical fire; evacuate area if fire cannot be quickly contained.
Related products
Brucella Set
$1.00
A Brucella Set is a comprehensive serological test system (Class II medical device, CE-marked/FDA-cleared) for qualitative and quantitative detection of antibodies against Brucella species (B. abortus, B. melitensis, B. suis, B. canis) using multiple methodologies including tube agglutination, slide agglutination, and 2-mercaptoethanol (2-ME) testing. The set includes killed, stained Brucella antigens, positive and negative controls, dilution tubes, reaction cards, and 2-ME reagent for IgM/IgG differentiation. Diagnostic titer ≥1:160 or fourfold rise confirms brucellosis. Primary clinical applications include diagnosis of brucellosis in endemic regions (undulant fever, night sweats, arthralgia), fever of unknown origin investigation, occupational health screening in high-risk workers (veterinarians, farmers, slaughterhouse workers), diagnosis of focal complications (sacroiliitis, spondylitis, meningitis, endocarditis), treatment monitoring (fourfold decline indicates response), outbreak investigation, and public health surveillance. Critical safety precautions include handling all samples in biosafety cabinet (Brucella is highly infectious via aerosol), 2-ME reagent toxicity (use fume hood), awareness of prozone phenomenon (serial dilutions essential), cross-reactions with other Gram-negative bacteria, and mandatory reporting to public health authorities. Essential test for brucellosis diagnosis in endemic regions and occupational health settings.
Centrifuge Tubes
$1.00
Centrifuge Tubes are specialized disposable containers (polypropylene) designed to withstand high centrifugal forces (up to 30,000 x g) for separating biological fluids based on density. Available in microcentrifuge sizes (0.2-2.0 mL), conical tubes (15 mL, 50 mL), and larger volumes (100-500 mL). Features include leak-proof screw caps with O-rings (conical tubes), snap caps (microcentrifuge tubes), graduated volume markings, writing areas, and sterile/non-sterile options. Certified RNase/DNase-free, pyrogen-free, and autoclavable. Primary clinical applications include blood component separation (serum/plasma), urine sediment preparation, microbiology sample concentration, molecular biology (DNA/RNA extraction), cell culture processing, protein/enzyme analysis, and viral load testing. Critical safety precautions include never exceeding maximum RCF rating, proper balancing by weight, secure cap tightening, inspection for cracks, and disposal as biohazardous waste. Essential consumable in every clinical, research, and industrial laboratory.
CRP Test Kit
$1.00
CRP Test Kit (C-Reactive Protein) is a quantitative or semi-quantitative immunoassay (latex agglutination, turbidimetry, nephelometry, ELISA, or rapid immunochromatographic) for detecting C-reactive protein in blood, an acute-phase reactant produced in response to inflammation. Rapid rise within 6-12 hours, peaks at 24-48 hours, half-life 19 hours. Normal <5-10 mg/L; mild elevation 10-100 mg/L (viral infections, autoimmune flares); moderate 100-200 mg/L (bacterial infections); marked >200 mg/L (sepsis, major trauma). High-sensitivity CRP (hs-CRP) detects 0.1-10 mg/L for cardiovascular risk stratification (<1 mg/L low risk, 1-3 mg/L moderate, >3 mg/L high). Primary clinical applications include detection and monitoring of inflammation, diagnosis and management of infections (differentiating bacterial from viral), assessment of autoimmune disease activity, post-surgical monitoring for complications, cardiovascular risk screening (hs-CRP), monitoring rheumatic fever and inflammatory conditions, and neonatal sepsis evaluation. Critical safety precautions include proper sample handling (universal precautions), quality control verification, awareness of non-specific elevation, prozone phenomenon in very high concentrations, and clinical correlation for interpretation. Essential test for evaluating inflammation across all medical specialties.
H.pylori test kits (Antigen)
$1.00
H.pylori test kits (Antigen) are Class II medical devices (FDA-cleared/CE-marked) for rapid immunochromatographic or enzyme immunoassay detection of Helicobacter pylori antigens in stool specimens, enabling non-invasive diagnosis of active infection and post-treatment eradication confirmation. Test principles use monoclonal or polyclonal antibodies specific to H. pylori antigens, producing visible results in 10-20 minutes (rapid tests) or 1-2 hours (EIA). Sensitivity 90-98%, specificity 92-99% compared to gold standard methods. Primary clinical applications include rapid diagnosis of H. pylori infection in patients with dyspepsia, initial screening in uncomplicated dyspepsia (test-and-treat strategy), confirmation of active infection before therapy, post-treatment eradication confirmation (4-6 weeks after therapy), pediatric testing (preferred non-invasive method), screening in high-risk populations (family history of gastric cancer), and monitoring in patients with peptic ulcer disease or MALT lymphoma. Critical safety precautions include mandatory washout period (4 weeks off antibiotics, 2 weeks off PPIs) to avoid false negatives, proper specimen handling (universal precautions), refrigerated storage of kits (2-30°C), quality control verification, and disposal as biohazardous waste. Essential non-invasive tool for H. pylori management in gastroenterology and primary care.
Hepatitis C Test Kit
$1.00
The Hepatitis C Test Kit is an in vitro diagnostic device for the detection of Hepatitis C virus antibodies or RNA in human blood, serum, or plasma samples. Available in rapid, laboratory immunoassay, and molecular formats, it screens for HCV infection, confirms active infection with RNA testing, and monitors treatment response. With high sensitivity and specificity exceeding 99%, it is essential for identifying infected individuals, linking them to curative direct-acting antiviral therapy, and confirming cure. Essential applications include risk-based screening of high-risk populations, birth cohort screening of baby boomers, evaluation of acute hepatitis, management of occupational exposures, and monitoring of antiviral therapy that can cure over 95% of infections. All patient samples must be handled with universal precautions, and positive antibody results require confirmatory testing.
Salmonella Typhi Test Peratop
$1.00
The Salmonella typhi test peratop is a CE-marked rapid immunochromatographic assay for qualitative detection of IgG and IgM antibodies to Salmonella enterica serotype Typhi in human serum, plasma, or whole blood, providing results in 15-20 minutes. The test uses recombinant S. typhi antigens immobilized on a membrane to capture specific antibodies, with separate lines for IgG and IgM interpretation. The kit includes individually foil-wrapped test cassettes, sample diluent, disposable pipettes, and package insert. Primary clinical applications include rapid diagnosis of typhoid fever in endemic regions (Indian subcontinent, Southeast Asia, Africa, South America), differentiation of acute (IgM positive) from past infection (IgG only), outbreak investigation and control, screening in febrile patients, travel medicine assessment, antibiotic stewardship, and maternal/child health in endemic areas. Critical safety precautions include proper specimen handling (universal precautions), quality control verification, awareness of window period (repeat testing if early infection suspected), and clinical correlation of results. Essential rapid test for typhoid fever diagnosis in resource-limited and endemic settings.
Vacutainer (EDTA/PLAIN)
$1.00
Vacutainer (EDTA/PLAIN) is a sterile, evacuated blood collection tube (lavender/purple top) containing EDTA anticoagulant (K2EDTA or K3EDTA, 1.5-2.0 mg/mL blood) for hematology, blood banking, flow cytometry, and molecular diagnostics. Available in draw volumes 2-10 mL, glass or PET plastic, with color-coded stopper and sterile interior. EDTA chelates calcium, preventing coagulation while preserving cellular morphology. Primary clinical applications include complete blood count (CBC) and differential, blood typing and antibody screening (ABO/Rh, Coombs), hemoglobin A1c (HbA1c) testing, flow cytometry and immunophenotyping (CD4 counts), molecular diagnostics and PCR testing, sickle cell screening and hemoglobin electrophoresis, and parasitology (malaria smears). Critical safety precautions include filling to completion (correct blood-to-additive ratio), gentle inversion 8-10 times immediately after collection, never using for chemistry or coagulation testing, and proper disposal as biohazardous waste. Essential collection tube for hematology and immunohematology.
VDRL Test For Syphilis
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties