Intelligent Decolorizing Shaker (SK-O180-S)

WhatsApp Order
The  Intelligent Decolorizing Shaker (SK-O180-S) is an intelligent orbital shaker featuring adjustable speed (50-350 rpm), fixed 20mm orbit amplitude, programmable timer (1-1199 minutes), RS232 interface, and a maintenance-free brushless DC motor, designed for uniform mixing of electrophoresis gels, Western blot membranes, and biological samples in clinical diagnostic and research laboratories .
Key features include orbital shaking action at 20mm orbit diameter for thorough, uniform mixing, dual independent LED displays for simultaneous monitoring of speed and time, programmable timer with automatic stop (1-1199 minutes), RS232 interface for computer connectivity and free PC software for real-time monitoring, user calibration support for speed accuracy, and a maintenance-free brushless DC motor for quiet, reliable operation . The 330 × 330 mm work platform with 3 kg load capacity securely holds culture dishes, flasks, beakers, blotting containers, and gel staining trays .
The Intelligent Decolorizing Shaker (SK-O180-S) accommodates a variety of laboratory vessels, with universal voltage (100-240V, 50/60Hz) enabling use in laboratories worldwide without voltage conversion . The cold room and incubator compatibility (5-40°C operating temperature, 80% RH) allows sample mixing under controlled temperature conditions for temperature-sensitive applications such as hybridizations and cell culture . The IP21 protection rating provides durability against dust and moisture in typical laboratory environments .
For the clinical laboratory scientist and molecular biologist, the SK-O180-S supports electrophoresis gel decolorization and staining (Coomassie blue, silver nitrate), Western blot membrane washing and antibody incubations, Southern and Northern blot hybridization reactions, immunoprecipitation (IP) protocols, liquid-solid suspension mixing (cell pellets, tissue homogenates), clinical sample preparation, and general liquid mixing for aeration and extraction applications .
Universal voltage (100-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion, while the moderate weight (6.5 kg) allows benchtop stability and efficient space utilization . The whisper-quiet brushless DC motor and safety speed protection ensure minimal noise, extended service life, and enhanced laboratory safety .
For the patient undergoing diagnostic testing for infectious diseases, genetic disorders, or cancer biomarkers, the Intelligent Decolorizing Shaker (SK-O180-S) uniform orbital mixing ensures consistent gel staining, reproducible antibody incubations, and accurate nucleic acid hybridization results—supporting reliable diagnostic outcomes that guide appropriate treatment decisions across molecular diagnostics, immunology, and cell biology applications .
Description

 Intelligent Decolorizing Shaker (SK-O180-S)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Electrophoresis Gel Decolorization and Staining Optimization
  • Primary Use: Provides an intelligent orbital shaker with adjustable speed (50-350 rpm), fixed orbit amplitude, and programmable timer (1-1199 minutes), specifically optimized for uniform and efficient decolorization of polyacrylamide and agarose gels .
  • How it helps: For the molecular biologist and clinical laboratory scientist, the Intelligent Decolorizing Shaker (SK-O180-S) orbital motion ensures even distribution of destaining solutions, accelerating background dye removal while preserving delicate gel integrity—resulting in sharper protein bands and more accurate densitometry for diagnostic assays . For the patient, this precision ensures reliable detection of protein abnormalities in conditions such as hereditary anemias, monoclonal gammopathies, or genetic protein disorders, reducing the need for repeat biopsies or blood draws .
2. Western Blot Membrane Washing and Agitation
  • Primary Use: Used for consistent, gentle washing of PVDF and nitrocellulose membranes during Western blotting, ensuring even reagent coverage and reducing non-specific background binding .
  • How it helps: For the clinical immunologist and research technologist, the smooth orbital motion (20mm orbit) provides thorough yet gentle agitation for wash buffers and antibody solutions—effectively reducing background noise and enhancing signal specificity in diagnostic immunoblots . For the patient undergoing confirmatory testing for HIV, Lyme disease, or autoimmune conditions, consistent membrane processing ensures accurate detection of disease-specific antibodies that guide diagnosis and treatment monitoring .
3. DNA Hybridization and Molecular Applications
  • Primary Use: Suitable for Southern blot, Northern blot, and in-situ hybridization protocols, as well as DNA renaturation processes, with cold room and incubator compatibility .
  • How it helps: For the molecular geneticist, the Intelligent Decolorizing Shaker (SK-O180-S) wide operating temperature range (5-40°C) allows use inside standard incubators or cold rooms for stringent temperature control during nucleic acid hybridization—improving binding specificity and reducing false positives . For the patient undergoing genetic cancer screening or hereditary disease testing, consistent hybridization conditions ensure high-fidelity results that guide clinical management .
4. General Liquid Mixing and Suspension Homogenization
  • Primary Use: Designed for mixing liquid samples in culture dishes, flasks, and beakers, supporting aeration, extraction, and resuspension applications in clinical diagnostic workflows .
  • How it helps: For the clinical laboratory scientist, the 3 kg load capacity and universal voltage (100-240V, 50/60Hz) allow versatile sample processing—from gentle mixing of patient serum samples to resuspension of cell pellets and tissue homogenates . For the patient, reliable sample preparation ensures that diagnostic test results accurately reflect the clinical specimen, reducing the risk of false results due to heterogeneous sample distribution .

SECONDARY & SUPPORTIVE USES

1. Electrophoresis Gel Staining: Distributes Coomassie blue, silver nitrate, and fluorescent stains evenly for consistent protein and nucleic acid detection .
2. Immunoprecipitation (IP): Provides the gentle but consistent rotation required for capturing antigen-antibody complexes in solution for downstream analysis .
3. Liquid-Solid Suspension Mixing: Effectively resuspends cell pellets, bacterial pellets, and homogenized tissue samples in buffers for DNA/RNA extraction .
4. Clinical Chemistry Sample Preparation: Mixes serum, plasma, or urine samples on a benchtop shaker before analysis on automated analyzers .
5. Cell Culture Aeration: Provides continuous orbital agitation for microbial, yeast, or mammalian cell cultures in flasks, ensuring adequate gas exchange and nutrient distribution .
6. Pharmaceutical Quality Control: Agitates QC samples for dissolution testing, stability studies, or content uniformity testing in pharmaceutical R&D and QC laboratories .
7. Fermentation and Bioprocessing: Provides consistent agitation for microbial or yeast cultures in flasks during small-scale fermentation and bioprocessing workflows .
8. Blood Bank and Transfusion Medicine: Supports gentle mixing of reagent red blood cells, antisera, and patient samples for compatibility testing and antibody screening .
9. Veterinary Diagnostic Laboratory: Supports mixing of biological specimens for animal health testing and infectious disease diagnosis .
10. Cold Room and Incubator Compatibility: Engineered to operate reliably in cold rooms (5-40°C) and standard incubators for temperature-sensitive applications such as hybridizations and cell culture .
11. University and Educational Laboratory Training: Provides reliable orbital mixing for teaching laboratory techniques in undergraduate and graduate science courses .
12. Research and Academic Laboratories: Provides intelligent orbital mixing for diverse research applications in cell biology, molecular biology, and biochemistry .
13. Environmental and Food Testing Laboratories: Used for mixing of environmental extracts and food samples for microbiological and chemical analysis .
14. Safety Speed Protection: Equipped with safety speed protection that prevents misuse or sudden overload conditions, enhancing laboratory safety .
15. Maintenance-Free Operation: Brushless DC motor eliminates routine brush replacement, reducing maintenance downtime .
16. User Calibration: Supports user calibration for speed control, ensuring accuracy across the full 50-350 rpm range .
17. RS232 Interface for Data Export: RS232 interface allows connection to a computer for data export and remote monitoring .
18. Free PC Software: Free Shaker PC software available for real-time display of working curves on a computer .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: An intelligent orbital decolorizing shaker with LED display, variable speed control (50-350 rpm), programmable timer (1-1199 minutes), RS232 interface, and maintenance-free brushless DC motor, designed for uniform mixing of electrophoresis gels, membranes, and biological samples in clinical diagnostic and research laboratories .
  • Designation: SK-O180-S Intelligent Decolorizing Shaker, Orbital Decolorizing Shaker, Laboratory Shaker, DLAB SK-O180-S, Intelligent Orbital Shaker .
  • Key Components:
o Motion Type: Orbital (circular) shaking motion .
o Orbit Diameter: 20 mm (fixed amplitude) .
o Work Platform: 330 × 330 mm loading platform with anti-slip surface for secure vessel placement .
o Motor: Maintenance-free brushless DC motor .
o Display: Dual independent LED displays for simultaneous speed and timer viewing .
o Control: Digital control with programmable timer .
o Interface: RS232 port for computer connectivity and PC software .
o Housing: Impact-resistant plastic body with non-slip base .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Speed Range: 50-350 rpm (variable, adjustable) .
  • Orbit Diameter: 20 mm .
  • Timer Range: 1 minute to 1199 minutes (programmable) .
  • Maximum Load Capacity: 3 kg (including accessories) .
  • Work Platform Dimensions (L × W): 330 × 330 mm .
  • External Dimensions (W × D × H): 420 × 430 × 106 mm .
  • Motor Type: Brushless DC motor (maintenance-free) .
  • Total Power: 30W .
  • Voltage/Frequency: 100-240V, 50/60Hz (universal voltage) .
  • Weight: 6.5 kg .
  • Operating Temperature: 5-40°C (cold room and incubator compatible) .
  • Permissible Ambient Humidity: ≤80% RH .
  • Protection Class: IP21 .
  • Interface: RS232 .
  • Compatibility: Suitable for culture dishes, flasks, beakers, blotting containers, and gel staining trays .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Impact-resistant plastic body with non-slip base for stable benchtop placement .
  • Motion Type: Orbital (circular) shaking motion at 20mm fixed orbit amplitude for thorough, uniform mixing .
  • Work Platform: Large 330 × 330 mm loading platform with anti-slip surface securely holds multiple vessels simultaneously .
  • Display: Dual independent LED displays show real-time speed (50-350 rpm) and timer (1-1199 minutes) simultaneously .
  • Control System: Digital speed control; programmable timer with automatic stop at end of set time .
  • Noise Level: Quiet operation (brushless DC motor) minimizes distractions in clinical laboratory environment .
  • Operating Conditions: Can be used in cold rooms (5-40°C) and standard incubators .
  • Portability: Moderate weight (6.5 kg) for benchtop stability; compact footprint for efficient bench space utilization .
  • Maintenance: Brushless DC motor eliminates routine brush replacement .
  • Safety Features: Equipped with safety speed protection to prevent misuse or sudden overload conditions .
  • Data Export: RS232 interface allows connection to computer; free Shaker PC software available for real-time display of working curves .
  • User Calibration: Supports user calibration for speed control accuracy .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards .
  • Safety Features: Safety speed protection prevents misuse or sudden overload conditions; IP21 protection rating provides protection against solid objects >12mm .
  • Electrical Safety: Universal voltage (100-240V, 50/60Hz) for international use; 30W low power consumption; earthed power connection recommended .
  • Motor Type: Brushless DC motor provides maintenance-free, quiet, stable operation .
  • Timer Safety: Programmable timer (1-1199 minutes) with automatic stop prevents over-mixing of sensitive samples .
  • Operating Conditions: 5-40°C ambient temperature; ≤80% relative humidity .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture.
  • Cleaning: Wipe work platform and housing with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; disconnect power before cleaning .
  • Inspection: Inspect power cord for damage before each use; check work platform for residue or wear; verify stability of benchtop placement .
  • Operation: Place unit on safe, stable surface; ensure operating voltage matches power supply; connect power cable; switch ON instrument .
  • Speed Setting: Set desired speed (50-350 rpm) using digital controls; LED display shows current speed setting .
  • Timer Setting: Set desired run time (1-1199 minutes); LED display shows current time setting; unit automatically halts when timer reaches zero .
  • Load Balancing: Distribute vessels evenly across work platform; do not exceed maximum load capacity (3 kg) .
  • Cold Room/Incubator Use: Unit can be placed in cold rooms (5-40°C) or standard incubators for temperature-sensitive applications .
  • Data Export: Connect to PC via RS232 interface to export data or use free Shaker PC software for real-time monitoring .
  • Spill Management: If liquid spills onto unit, disconnect power immediately, clean thoroughly, allow to dry before reuse .

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Uniform orbital mixing for electrophoresis gel decolorization and staining, Western blot membrane washing, DNA hybridization, and general sample preparation in clinical diagnostic, molecular biology, and research laboratories .
  • Clinical Role: Essential mixing equipment in clinical diagnostic laboratories, molecular biology labs, immunology laboratories, pharmaceutical research laboratories, and academic research institutions .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources .
  • Load Limits: Do not exceed maximum load capacity (3 kg); ensure load is evenly distributed across work platform to prevent imbalance .
  • Spill Protection: Use appropriate vessel caps or seals to prevent sample leakage; clean spills immediately .
  • Speed Selection: Select appropriate speed for sample type (50-350 rpm); use lower speeds (50-100 rpm) for delicate membrane washing steps; use higher speeds (250-350 rpm) for gel destaining solutions .
  • Cold Room/Incubator Use: Ensure instrument is placed on stable surface within cold room or incubator; operating temperature range 5-40°C; permissible ambient humidity ≤80% RH .
  • Timer Use: Set appropriate time for mixing protocol; do not exceed recommended mixing times for sensitive samples; unit automatically halts when timer reaches zero .
  • Platform Cleaning: Clean work platform regularly to prevent residue buildup and maintain vessel stability .
  • User Calibration: Perform speed calibration periodically to ensure accuracy across the full speed range .
  • Training: Only trained laboratory personnel should operate the SK-O180-S for clinical diagnostic applications .

2. FIRST AID MEASURES

  • Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water .
  • Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel .
  • Mechanical Failure: If unit fails to operate or makes abnormal noise, disconnect power, check for obstruction, contact service if issue persists .
  • Chemical Spill: If corrosive chemicals spill on unit, disconnect power immediately, wipe with appropriate neutralizer, dry thoroughly before reconnecting power .

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn .
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires .
  • Fire Response: Unplug unit immediately; do not use water on electrical fire .