Isometric gene amplification instrument (TC1000-S)

WhatsApp Order
The  Isometric Gene Amplification Instrument is a 96-well benchtop thermal cycler (PCR instrument) featuring advanced Peltier heating/cooling technology (5°C/sec ramp rate), precise temperature control (accuracy ±0.3°C at 55°C), excellent temperature uniformity (<0.3°C at 55°C), edge temperature compensation to minimize “edge effect”, 7-inch LCD color touchscreen (800×480), Touchdown PCR support (-9.9°C to +9.9°C), Long PCR support (-9min 59s to +9min 59s), power failure protection with automatic program recovery, and one-click fast incubation for denaturation/enzyme digestion/ELISA, designed for DNA amplification in clinical diagnostic, molecular biology, and research laboratories .
Key features include a 96-well aluminum block compatible with PCR tubes, 8-strips, and 96-well PCR plates, heated lid with automatic temperature control (30-110°C) and auto-off function when block <30°C, intuitive 7-inch color touchscreen for easy program editing, user-defined file system supporting up to 30 segments and 99 cycles per program, and storage for over 200 custom programs across 16 folders .
The  Isometric gene amplification instrument supports standard PCR, Touchdown PCR for enhanced specificity (minimizing nonspecific amplification and primer-dimer formation), and Long PCR for large fragment amplification . Edge temperature compensation technology ensures consistent amplification across all 96 wells, eliminating temperature variation at block edges . One-click fast incubation provides quick access to common laboratory protocols including denaturation, enzyme digestion/ligation, and ELISA, reducing setup time and minimizing programming errors . Power failure protection automatically resumes unfinished cycles upon power restoration, ensuring sample safety during extended runs .
For the clinical laboratory scientist and molecular biologist, the  Isometric gene amplification instrument supports infectious disease detection (COVID-19, HIV, hepatitis, tuberculosis, HPV, influenza), genetic mutation screening (β-thalassemia, BRCA, CFTR), gene cloning, DNA sequencing preparation, forensic DNA analysis (STR amplification), genotyping and SNP detection, and food safety pathogen detection .
Universal voltage (100-120V/200-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion, while the compact footprint (280 × 370 × 250 mm) and moderate weight (11 kg) allow easy benchtop placement . The 4-105°C temperature range and 5°C/sec ramp rate provide rapid, reliable thermal cycling for routine diagnostic applications .
For the patient undergoing infectious disease testing, genetic screening for hereditary disorders, or oncology biomarker detection, the  Isometric gene amplification instrument precise temperature control, edge temperature compensation, and Touchdown PCR capability ensure accurate, reproducible PCR results that guide appropriate treatment decisions across clinical infectious disease, oncology, genetics, and molecular diagnostics applications .
Description

Isometric gene amplification instrument

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Polymerase Chain Reaction (PCR) for Infectious Disease Detection
  • Primary Use: Provides a 96-well thermal cycler (PCR instrument) with a temperature range of 4-105°C, heating/cooling rate of 5°C/sec, and temperature control accuracy of ±0.3°C at 55°C, designed for amplification of specific DNA sequences from pathogens to detect infectious diseases .
  • How it helps: For the clinical laboratory scientist and molecular biologist, the  Isometric gene amplification instrument precise temperature control and high ramp rate ensure efficient, reproducible DNA amplification from patient specimens—critical for accurate diagnosis of viral, bacterial, and fungal infections. The 7-inch color touchscreen and intuitive program editing interface simplify assay setup . For the patient, reliable PCR results enable early detection of infectious diseases (COVID-19, HIV, hepatitis, tuberculosis, HPV, influenza), guiding appropriate antiviral or antibiotic therapy.
2. Touchdown PCR for Enhanced Specificity
  • Primary Use: Supports Touchdown PCR programs with a range of -9.9°C to +9.9°C, enabling gradual decrease of annealing temperature during cycling to enhance amplification specificity .
  • How it helps: For the molecular diagnostics developer and research scientist, Touchdown PCR minimizes nonspecific amplification and primer-dimer formation—critical for detecting rare mutations, low-abundance targets, and complex clinical specimens. For the patient undergoing genetic testing for inherited disorders or oncology biomarkers, enhanced specificity reduces false-positive results, ensuring accurate diagnosis and appropriate treatment planning.
3. Long PCR for Large Fragment Amplification
  • Primary Use: Supports Long PCR programs with time adjustment range of -9 minutes 59 seconds to +9 minutes 59 seconds, allowing amplification of DNA fragments up to several kilobases .
  • How it helps: For the molecular biologist and clinical geneticist, Long PCR enables amplification of large genomic regions for sequencing, mutation detection, and structural variant analysis—essential for diagnosing genetic disorders involving large deletions or duplications. For the patient, comprehensive genetic analysis supports definitive diagnosis of hereditary conditions such as Duchenne muscular dystrophy, spinal muscular atrophy, and other disorders involving large genetic alterations.
4. Genetic Mutation Screening for Hereditary Disorders
  • Primary Use: Used for amplification of DNA fragments from patient samples to detect genetic mutations associated with hereditary disorders, including β-thalassemia, sickle cell disease, cystic fibrosis, and BRCA-associated cancers .
  • How it helps: For the clinical geneticist and molecular pathologist, the Isometric gene amplification instrument enables rapid, reliable amplification of specific gene regions—facilitating detection of point mutations, insertions, deletions, and other genetic variants. For the patient undergoing hereditary disease screening, accurate PCR results inform genetic counseling, reproductive decision-making, and preventive healthcare measures.
5. One-Click Fast Incubation for Routine Laboratory Protocols
  • Primary Use: Features one-click fast incubation functions for denaturation, enzyme digestion/ligation, ELISA, and other common laboratory protocols, simplifying routine molecular biology workflows .
  • How it helps: For the clinical laboratory scientist and research technician, pre-programmed one-click protocols reduce setup time and minimize programming errors—improving laboratory efficiency and ensuring consistent sample treatment across runs. For the patient, standardized protocol execution reduces inter-run variability, improving the reliability of diagnostic test results.

SECONDARY & SUPPORTIVE USES

1. Reverse Transcription PCR (RT-PCR): Used with reverse transcriptase enzymes to amplify RNA targets for detection of RNA viruses (influenza, RSV, Ebola, Zika) and gene expression analysis.
2. Gene Cloning and Molecular Biology Research: Used for preparation of DNA inserts for plasmid construction, bacterial transformation, and recombinant protein expression workflows in research laboratories .
3. DNA Sequencing Preparation: Amplifies target DNA regions for Sanger sequencing, next-generation sequencing (NGS) library preparation, and amplicon sequencing applications .
4. Forensic DNA Analysis: Supports STR (short tandem repeat) amplification for human identification in forensic casework and paternity testing .
5. Genotyping and SNP Detection: Used for amplification of specific gene regions to identify single nucleotide polymorphisms (SNPs) for pharmacogenetic testing and disease risk assessment.
6. Mutagenesis and Site-Directed Mutagenesis: Supports PCR-based mutagenesis for protein engineering and functional genomics research .
7. Food Safety and Pathogen Detection: Used for detection of foodborne pathogens (Salmonella, Listeria, E. coli O157:H7) in food safety testing laboratories.
8. Agricultural and Plant Research: Supports detection of plant pathogens, genetically modified organism (GMO) screening, and marker-assisted breeding applications .
9. Veterinary Diagnostic Testing: Used for detection of animal pathogens (canine parvovirus, feline leukemia, avian influenza) in veterinary diagnostic laboratories.
10. Environmental Microbiology: Supports detection of waterborne pathogens and microbial source tracking in environmental water quality testing.
11. Drug Discovery and Pharmaceutical Research: Used in drug discovery workflows for target validation, biomarker identification, and pharmacogenomic studies .
12. Epigenetic Analysis: Used for methylation-specific PCR (MSP) and bisulfite sequencing PCR for DNA methylation studies in cancer research.
13. Food Industry Quality Control: Supports PCR-based testing in food manufacturing for quality assurance and regulatory compliance .
14. Blood Bank Screening: Used for screening blood donations for transfusion-transmitted infections including HIV, hepatitis B, hepatitis C, and West Nile virus.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A 96-well benchtop thermal cycler (PCR instrument) with advanced Peltier heating/cooling technology, 5°C/sec ramp rate, 7-inch color touchscreen, and power failure protection, designed for DNA amplification in clinical diagnostics, molecular biology, and research laboratories .
  • Designation: Isometric Gene Amplification Instrument,  Isometric gene amplification instrument Thermal Cycler, Standard PCR Machine, Gene Amplification Instrument, DLAB  Isometric Gene Amplification Instrument .
  • Key Components:
o Sample Block: 96-well aluminum block (0.2mL) compatible with PCR tubes, 8-strips, and 96-well PCR plates .
o Heating/Cooling System: High-performance Peltier elements with independent heating segments .
o Heated Lid: Adjustable temperature range 30-110°C; automatic shutoff when block temperature <30°C .
o Display: 7-inch LCD color touchscreen (800×480 resolution) .
o Power Supply: Universal voltage (100-120V/200-240V, 50/60Hz) with power failure protection .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Sample Capacity: 96 × 0.2mL PCR tubes; 12 × 0.2mL PCR 8-strips; 96-well PCR plates (no skirt, half-skirt, full-skirt) .
  • Heating Temperature Range: 4-105°C .
  • Heated Lid Temperature Range: 30-110°C .
  • Temperature Display Accuracy: ±0.1°C .
  • Temperature Control Accuracy (at 55°C): ±0.3°C .
  • Temperature Uniformity (at 55°C): <0.3°C .
  • Maximum Heating/Cooling Rate: 5°C per second .
  • Edge Temperature Compensation: Yes; auxiliary heating mechanism diminishes "edge effect" and enhances temperature uniformity .
  • Touchdown PCR Range: -9.9°C to +9.9°C .
  • Long PCR Time Adjustment: -9 minutes 59 seconds to +9 minutes 59 seconds .
  • 1-Step Fast Incubation: Yes (denaturation, enzyme digestion/ligation, ELISA) .
  • Power Failure Protection: Yes; automatically resumes unfinished cycles upon power restoration .
  • Display: 7-inch LCD color touchscreen (800×480 resolution) .
  • User Defined File System: Maximum 30 segments, 99 cycles; 16 folders, each folder up to 16 files; storage for over 200 files .
  • Voltage/Frequency: 100-120V/200-240V, 50/60Hz .
  • Dimensions (W × D × H): 280 × 370 × 250 mm .
  • Weight: 11 kg .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Sturdy benchtop housing with durable aluminum sample block; high-performance Peltier elements for reliable temperature control .
  • Display: 7-inch LCD color touchscreen (800×480) with intuitive graphical user interface; simple program editing .
  • User Interface: Color touch panel with easy-to-navigate menus; supports program customization and multi-file storage .
  • Temperature Control Methods: Block control or tube control mode .
  • Edge Temperature Compensation: Reduces temperature variation across the block, minimizing "edge effect" for consistent amplification in all wells .
  • Hot Lid Function: Adjustable lid temperature (30-110°C); automatically turns off when block temperature drops below 30°C to conserve energy and extend component life .
  • One-Click Fast Incubation: Quick access to denaturation, enzyme digestion/ligation, ELISA, and other common incubation protocols .
  • Power Failure Protection: Automatic program recovery; completes unfinished cycles after power restoration; ensures sample safety during extended runs .
  • Portability: Compact benchtop design (280 × 370 × 250 mm) and moderate weight (11 kg) for easy benchtop placement .
  • Maintenance: Peltier elements designed for long-term durability; periodic calibration recommended.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: Medical device for in vitro diagnostic use; complies with international laboratory safety standards .
  • Safety Features: Power failure protection with automatic program recovery; over-temperature protection; hot lid automatic shutoff (when block <30°C) .
  • Electrical Safety: Universal voltage (100-120V/200-240V, 50/60Hz) for international use; earthed power connection recommended; 600W power consumption .
  • Program Security: User-defined file system with password protection capability; customizable access levels for different users .
  • GLP Compliance: Program storage and user authentication support GLP documentation; real-time run monitoring.
  • Data Integrity: USB data export for program and data backup; supports user-defined file management .
  • Materials: Aluminum sample block (thermal conductivity and durability); durable plastic housing .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture; ambient temperature 5-40°C, ≤80% RH.
  • Cleaning: Wipe exterior with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface disinfection; do not immerse in liquid; disconnect power before cleaning.
  • Inspection: Inspect power cord for damage before each use; check sample block for debris or residue; verify heated lid seal integrity.
  • Operation: Place on stable, level surface; ensure adequate ventilation; connect to appropriate power supply; power ON; select or create program; load samples into 96-well block or plate; close lid securely; start run; monitor progress on touchscreen .
  • Program Creation: Use touchscreen interface to create new programs; set denaturation, annealing, and extension temperatures and times; configure cycle numbers (max 99 cycles, 30 segments); save to internal memory .
  • Touchdown PCR Programming: Configure touchdown range (-9.9°C to +9.9°C) to gradually decrease annealing temperature for enhanced specificity .
  • Long PCR Programming: Adjust extension time (-9min 59s to +9min 59s) for amplification of long DNA fragments .
  • One-Click Incubation: Select pre-programmed protocols for denaturation, enzyme digestion/ligation, or ELISA from touchscreen menu .
  • File Management: Organize programs into folders (up to 16 folders, each up to 16 files); storage for over 200 custom programs .
  • Power Failure Recovery: If power fails during run, instrument automatically resumes unfinished cycles upon power restoration; samples are preserved .
  • 4°C Hold: After program completion, samples are held at 4°C indefinitely to preserve amplified products.
  • Spill Management: If liquid spills onto unit, disconnect power immediately, clean thoroughly with appropriate disinfectant, allow to dry before reuse.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: DNA amplification via polymerase chain reaction (PCR) for infectious disease detection, genetic mutation screening, gene cloning, DNA sequencing preparation, and forensic DNA analysis in clinical diagnostic, molecular biology, and research laboratories .
  • Clinical Role: Essential molecular diagnostics equipment in clinical diagnostic laboratories, hospital molecular pathology departments, infectious disease reference laboratories, genetics laboratories, blood banks, forensic laboratories, and research institutions performing PCR-based patient testing .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources and sharp edges; use only properly grounded electrical outlets.
  • Sample Containment: Use appropriate biosafety practices when handling infectious samples; prepare samples in biosafety cabinet when indicated; seal tubes and plates to prevent aerosol generation.
  • Hot Surface Warning: Heated lid reaches temperatures up to 110°C; allow to cool before opening or handling; use caution when opening lid immediately after run completion.
  • Cross-Contamination Prevention: Use filter pipette tips; perform setup in designated pre-PCR and post-PCR areas; use UNG (uracil-N-glycosylase) for carryover prevention when indicated.
  • Ventilation: Ensure adequate ventilation; unit generates heat during operation; do not block ventilation openings; place in well-ventilated area.
  • Sample Tube Compatibility: Use only PCR-grade tubes, strips, or plates rated for thermal cycling; ensure proper sealing to prevent evaporation and sample loss.
  • Load Limits: Do not exceed 96-sample capacity; load tubes or plates symmetrically for optimal thermal performance.
  • Training: Only trained laboratory personnel should operate the  Isometric gene amplification instrument for clinical diagnostic applications.

2. FIRST AID MEASURES

  • Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
  • Burn: If hot lid or sample block contacts skin, cool affected area with cool running water for 15 minutes; seek medical attention for severe burns.
  • Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel.
  • Power Failure: If power fails during critical run, samples will be preserved; upon restoration, program automatically resumes; assess sample integrity before proceeding with downstream analysis.
  • Chemical Spill: If corrosive chemicals spill on unit, disconnect power immediately, wipe with appropriate neutralizer, dry thoroughly before reconnecting power.

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn; Peltier elements are solid-state and non-flammable.
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires.
  • Fire Response: Unplug unit immediately; do not use water on electrical fire; evacuate area if fire cannot be quickly contained.