Long Deck Double Layer Rocking Rotator (SK-R30D-E)
WhatsApp Order
The Long Deck Double Layer Rocking Rotator is a long-deck double-layer rocking rotator featuring adjustable speed control (0-30 rpm), fixed 40° tilt angle, continuous operation mode, and a maintenance-free brushless DC motor, designed for gentle, uniform mixing of blood tubes, serology specimens, and molecular biology samples in clinical diagnostic and research laboratories .
Key features include a double-layer deck design (405mm length) that accommodates up to 16 × 5-10mL blood collection tubes or 6 × 50mL centrifuge tubes per layer (up to 32 tubes total) using interchangeable silicone mattresses, fixed 40° ± 3° rocking motion for gentle, thorough mixing, continuous operation mode for extended use, analog speed control (0-30 rpm), and a maintenance-free brushless DC motor for quiet, reliable operation . The unit’s compact footprint (405 × 160 × 160 mm) and lightweight design (2.2 kg) allow easy benchtop placement .
The SK-R30D-E accommodates a variety of tube formats via interchangeable silicone mattress accessories, with universal voltage (100-240V, 50/60Hz) enabling use in laboratories worldwide without voltage conversion . The cold room and incubator compatibility (5-40°C operating temperature, ≤80% RH) allows sample mixing under controlled temperature conditions for temperature-sensitive applications .
For the clinical laboratory scientist and phlebotomist, the SK-R30D-E ensures gentle, thorough mixing of blood samples after collection—preventing clot formation, platelet activation, and hemolysis that could compromise complete blood count (CBC) and coagulation study (PT/PTT) results . For the immunology technologist, it supports RPR and VDRL serological testing for infectious diseases (HIV, syphilis, hepatitis) . For the molecular biologist, it facilitates gentle mixing of DNA, RNA, and protein samples for PCR and sequencing workflows .
Universal voltage (100-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion . The double-layer design maximizes throughput while maintaining a small benchtop footprint . The silicone mattresses provide secure tube retention and are easy to clean and decontaminate between sample batches .
For the patient undergoing coagulation monitoring (warfarin, heparin), complete blood count (CBC), serological testing for infectious diseases, or molecular diagnostic testing, the Long Deck Double Layer Rocking Rotator
gentle rocking motion ensures accurate test results that guide appropriate treatment decisions—preventing false-negative or false-positive results due to improper sample mixing, clot formation, or platelet activation .
Categories: LABORATORY EQUIPMENT AND SUPPLIES, Lab Consumables
Tags: Blood Sample Mixer, Clinical Laboratory Equipment, Coagulation Prevention, DLAB SK-R30D-E, Double Layer Rocking Mixer, Laboratory Rocking Rotator, Rocking Rotator, Sample Preparation, Serology Mixing, SK-R30D-E Long Deck Double Layer Rocking Rotator
Description
Long Deck Double Layer Rocking Rotator (SK-R30D-E)
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Gentle Blood Sample Mixing for Coagulation Testing
-
Primary Use: Provides a long-deck double-layer rocking rotator with adjustable speed (0-30 rpm) and a fixed 40° tilt angle, designed for gentle, uniform mixing of whole blood samples to prevent coagulation and ensure accurate PT/PTT test results .
-
How it helps: For the clinical laboratory scientist and phlebotomist, the SK-R30D-E’s 40° rocker motion ensures thorough mixing of blood samples without causing hemolysis or activating platelets—critical for preventing micro-clot formation in light blue top coagulation tubes . For the patient undergoing anticoagulant therapy monitoring (warfarin, heparin), proper gentle mixing ensures accurate coagulation test results that guide appropriate medication dosing and clinical management.
2. High-Capacity Batch Processing for Clinical Laboratories
-
Primary Use: Featuring a double-layer deck design compatible with various silicone mattresses, it can accommodate up to 16 × 5~10mL blood collection tubes or 6 × 50mL tubes per layer, enabling simultaneous processing of multiple patient samples .
-
How it helps: For the laboratory manager, the high capacity (up to 32 small tubes total) allows for batch processing of coagulation and serology samples, significantly improving workflow efficiency and reducing turnaround times . For the patient, batch processing reduces laboratory turnaround time for routine coagulation and serology testing, enabling faster clinical decision-making.
3. Serology and Immunoassay Sample Preparation
-
Primary Use: Used for uniform mixing of serum and plasma specimens in RPR, VDRL, and other serological screening tests requiring gentle, consistent agitation .
-
How it helps: For the immunology technologist, the consistent 40° rocker motion ensures even distribution of reagents without damaging delicate protein complexes—critical for accurate antibody detection in serological testing for infectious diseases (HIV, syphilis, hepatitis) . For the patient undergoing serological testing, standardized gentle mixing ensures accurate antibody detection that guides appropriate treatment decisions.
4. Molecular Biology Sample Preparation
-
Primary Use: Supports gentle mixing of DNA, RNA, and protein samples for PCR, sequencing, and blotting workflows without shearing .
-
How it helps: For the molecular biologist, the SK-R30D-E’s gentle rocking motion (0-30 rpm) allows low-speed mixing of sensitive biomolecules—preserving the integrity of high molecular weight DNA, RNA, and antibody structures during sample preparation . For the patient undergoing molecular diagnostic testing for genetic disorders or infectious diseases, careful sample handling ensures that diagnostic tests accurately reflect the patient’s clinical status.
5. Cold Room and Incubator Compatibility
-
Primary Use: Designed for use in cold rooms (5-40°C, 80% RH) and incubators, allowing sample mixing under controlled temperature conditions for temperature-sensitive applications .
-
How it helps: For the clinical laboratory scientist and research technician, the SK-R30D-E’s wide operating temperature range (5-40°C) allows sample mixing in cold rooms for temperature-sensitive antibody binding reactions, as well as in incubators for cell culture and microbiology workflows . For the patient, temperature-controlled mixing preserves sample integrity for temperature-sensitive assays, supporting accurate diagnostic results for conditions requiring strict temperature control during sample processing.
6. Brushless DC Motor for Maintenance-Free Operation
-
Primary Use: Utilizes a maintenance-free brushless DC motor providing quiet operation, high stability, and reliable long-term performance for continuous laboratory use .
-
How it helps: For the laboratory manager, the brushless DC motor eliminates routine brush replacement, reduces maintenance downtime, and ensures consistent performance over years of daily use—improving laboratory efficiency and reducing total cost of ownership . For the patient, reliable, consistent mixer performance ensures that sample preparation quality does not degrade over time, supporting reproducible diagnostic results.
7. Continuous Operation for Extended Use
-
Primary Use: Supports continuous operation mode for extended mixing protocols, allowing uninterrupted sample processing throughout the workday .
-
How it helps: For the clinical laboratory scientist, continuous operation mode allows extended, hands-free mixing of samples during incubations and other time-sensitive protocols—improving workflow efficiency and reducing operator intervention . For the patient, uninterrupted processing reduces the risk of sample degradation due to interrupted mixing cycles, supporting consistent diagnostic results.
SECONDARY & SUPPORTIVE USES
1. Prevention of Blood Coagulation in Whole Blood Samples: Used for gentle, continuous mixing of whole blood samples to prevent clot formation before complete blood count (CBC) and coagulation testing .
2. Immunoprecipitation and Antibody-Antigen Reactions: Supports gentle rocking mixing for immunoprecipitation protocols and antibody-antigen reaction studies in immunology research .
3. Cell Suspension and Culture Media Mixing: Used for gentle mixing of cell suspensions, culture media, and biological fluids to preserve cell viability and prevent sedimentation .
4. Latex Agglutination and Serological Tests: Used for mixing latex bead reagents and patient samples in agglutination-based diagnostic tests for infectious diseases .
5. Biological Fluid Homogenization: Used for homogenization of plasma, serum, and other biological fluids for clinical chemistry and immunoassay preparation .
6. Microbiology Culture Tube Mixing: Supports mixing of bacterial cultures, fungal suspensions, and microbiological samples in tubes for growth and assay preparation .
7. Pharmaceutical Formulation Development: Used for mixing of drug formulations, suspensions, and viscous pharmaceutical preparations during product development .
8. Research and Academic Laboratories: Provides gentle rocking mixing for diverse research applications in cell biology, biochemistry, molecular biology, and biotechnology .
9. Blood Bank and Transfusion Medicine: Supports gentle mixing of blood components, donor blood samples, and reagent red blood cells for compatibility testing .
10. Veterinary Diagnostic Laboratory: Used for mixing of blood, serum, and other biological specimens for animal health testing and infectious disease diagnosis .
11. Environmental and Food Testing Laboratories: Supports mixing of environmental extracts and food samples for microbiological and chemical analysis .
12. Clinical Chemistry Sample Preparation: Used for mixing blood samples for complete blood count (CBC), coagulation studies (PT/PTT), and clinical chemistry panels .
13. Quality Control Sample Mixing: Used for mixing quality control (QC) samples to ensure batch-to-batch consistency in clinical laboratory quality assurance programs .
14. Cold Room Sample Preparation: Compatible with cold room use (5-40°C) for temperature-sensitive sample mixing protocols .
15. Incubator-Compatible Cell Culture: Suitable for use in incubators for cell culture and microbiology applications requiring controlled temperature environments .
16. Gentle Dissolution of Solids: Used for gentle dissolution of powdered reagents, crystalline materials, and freeze-dried products into liquid solvents .
17. Multi-Tube Format Compatibility: Compatible with various tube formats including 5-10mL blood collection tubes, 50mL centrifuge tubes, and other laboratory tubes via interchangeable silicone mattresses .
18. Accessory Versatility: Available with various silicone mattress accessories for different tube sizes and configurations .
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A long-deck double-layer rocking rotator with adjustable speed (0-30 rpm), fixed 40° tilt angle, continuous operation mode, and maintenance-free brushless DC motor, designed for gentle mixing of blood tubes, serology specimens, and molecular biology samples in clinical diagnostic and research laboratories .
-
Designation: SK-R30D-E Long Deck Double Layer Rocking Rotator, Rocking Rotator, Double Layer Rocking Mixer, Laboratory Rocking Rotator, DLAB SK-R30D-E .
-
Key Components:
o Rocking Deck: Double-layer long deck platform (405mm length) .
o Silicone Mattresses: Interchangeable silicone pads for various tube sizes (5-10mL blood collection tubes, 50mL centrifuge tubes) .
o Motor: Maintenance-free brushless DC motor .
o Control: On/Off switch; continuous operation only (no timer) .
o Speed Adjustment: Manual speed control (0-30 rpm) .
o Housing: Impact-resistant plastic body with non-slip base .
o Tilt Angle: Fixed 40° ± 3° rocking motion .
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Motion Type: Rocking rotator (rocking motion) .
-
Tilt Angle: 40° ± 3° (fixed) .
-
Speed Range: 0-30 rpm (variable, adjustable) .
-
Speed Display: No digital display; analog speed control .
-
Timer: No timer; continuous operation only .
-
Run Type: Continuous operation .
-
Maximum Load Capacity: 1 kg (all levels combined) .
-
Motor Type: Brushless DC motor (maintenance-free) .
-
Power: 15W .
-
Voltage/Frequency: 100-240V, 50/60Hz (universal voltage) .
-
Dimensions (D × W × H): 405 × 160 × 160 mm .
-
Weight: 2.2 kg .
-
Operating Temperature: 5-40°C (cold room and incubator compatible) .
-
Permissible Ambient Humidity: ≤80% RH .
-
Protection Class: Not specified .
-
Tube Capacity (Single Layer): Up to 16 × 5-10mL blood collection tubes or 6 × 50mL centrifuge tubes (using appropriate silicone mattresses) .
-
Total Capacity (Double Layer): Up to 32 × 5-10mL blood collection tubes or 12 × 50mL centrifuge tubes .
-
Compatibility: 5-10mL blood collection tubes, 50mL centrifuge tubes, 15mL centrifuge tubes (with appropriate silicone mattresses) .
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: Impact-resistant plastic body with non-slip base for stable benchtop placement; double-layer deck design for high-capacity processing .
-
Deck Design: Long deck (405mm length) with double-layer configuration; each layer can accommodate different silicone mattress accessories for various tube sizes .
-
Silicone Mattresses: Interchangeable silicone pads secure tubes during operation; available for 5-10mL blood collection tubes (16-position) and 50mL centrifuge tubes (6-position) .
-
Motion Type: Rocking rotator motion at fixed 40° tilt angle for gentle, uniform mixing .
-
Speed Control: Manual analog speed control (0-30 rpm) .
-
Operation Mode: Continuous operation only; unit runs continuously once turned on; no timer function .
-
Noise Level: Quiet operation (brushless DC motor) minimizes distractions in clinical laboratory environment .
-
Operating Conditions: Can be used in cold rooms (5-40°C) and standard incubators .
-
Portability: Compact footprint (405 × 160 × 160 mm) and lightweight (2.2 kg) for easy benchtop placement .
-
Maintenance: Brushless DC motor eliminates routine brush replacement .
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards .
-
Safety Features: Non-slip base prevents movement during operation .
-
Electrical Safety: Universal voltage (100-240V, 50/60Hz) for international use; 15W low power consumption; earthed power connection recommended .
-
Motor Type: Brushless DC motor provides maintenance-free, quiet, stable operation .
-
Tube Security: Silicone mattresses secure tubes during rocking motion, preventing dislodgment .
-
Operating Conditions: 5-40°C ambient temperature; ≤80% relative humidity .
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store on clean, dry, level benchtop; protect from dust and moisture.
-
Cleaning: Wipe deck and housing with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; disconnect power before cleaning; silicone mattresses can be removed and cleaned separately .
-
Inspection: Inspect power cord for damage before each use; check silicone mattresses for wear or residue; verify stability of benchtop placement .
-
Operation: Place unit on safe, stable surface; ensure operating voltage matches power supply; connect power cable; switch ON instrument; adjust speed using manual control knob (0-30 rpm) .
-
Speed Selection: Select appropriate speed for sample type (0-30 rpm); use lower speeds (5-15 rpm) for blood coagulation samples to prevent platelet activation; use higher speeds (20-30 rpm) for general mixing applications .
-
Tube Loading: Load tubes symmetrically into silicone mattresses; distribute tubes evenly across both layers to maintain balanced load; do not exceed maximum load capacity (1 kg total) .
-
Mattress Selection: Use appropriate silicone mattress for tube size: 16-position mattress for 5-10mL blood collection tubes; 6-position mattress for 50mL centrifuge tubes .
-
Continuous Operation: Unit operates in continuous mode only; ensure unit is monitored during extended operation; no automatic stop function .
-
Spill Management: If liquid spills onto unit, disconnect power immediately, clean thoroughly, allow to dry before reuse; silicone mattresses facilitate spill management .
-
Maintenance: If service required, instrument must be cleaned in advance to avoid pollution of hazardous substances .
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: Gentle rocking mixing of blood tubes (coagulation prevention), serology specimens, immunology samples, and molecular biology preparations in clinical diagnostic laboratories, blood banks, and research facilities .
-
Clinical Role: Essential mixing equipment in clinical diagnostic laboratories, coagulation laboratories, serology laboratories, blood banks, hematology laboratories, molecular diagnostics labs, and research facilities requiring gentle sample mixing .
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Electrical Safety: Disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources .
-
Tube Security: Ensure tubes are securely seated in silicone mattresses before starting operation; verify that mattresses are properly positioned on deck .
-
Balanced Loading: Load tubes symmetrically across both layers to prevent imbalance and excessive motor strain; do not exceed maximum load capacity (1 kg total) .
-
Speed Selection: Select appropriate speed for sample type (0-30 rpm); use lower speeds (5-15 rpm) for blood coagulation samples to prevent platelet activation; use higher speeds (20-30 rpm) for general mixing applications .
-
Continuous Operation: Unit operates in continuous mode only; ensure unit is monitored during extended operation; no automatic stop function; turn off manually when mixing is complete .
-
Cold Room/Incubator Use: Ensure instrument is placed on stable surface within cold room or incubator; operating temperature range 5-40°C; permissible ambient humidity ≤80% RH .
-
Mattress Selection: Use appropriate silicone mattress for tube size to ensure proper tube fit and security .
-
Cleaning: Clean spills immediately; disinfect silicone mattresses if biological materials are involved; allow to dry before reuse .
-
Training: Only trained laboratory personnel should operate the SK-R30D-E for clinical diagnostic applications .
2. FIRST AID MEASURES
-
Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water .
-
Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel .
-
Mechanical Failure: If unit fails to operate or makes abnormal noise, disconnect power, check for obstruction, contact service if issue persists .
-
Chemical Spill: If corrosive chemicals spill on unit, disconnect power immediately, wipe with appropriate neutralizer, dry thoroughly before reconnecting power .
-
Tube Dislodgment: If tube becomes dislodged during operation, stop unit immediately, remove dislodged tube, assess for sample loss, clean affected area .
3. FIRE FIGHTING MEASURES
-
Flammability: Plastic housing and electrical components may burn .
-
Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires .
-
Fire Response: Unplug unit immediately; do not use water on electrical fire .
Related products
Anti-Streptol Olysin O Titer (ASOT)
$24.23
Anti-Streptol Olysin O Titer (ASOT) is a quantitative or semi-quantitative serological test (latex agglutination, turbidimetry, nephelometry, or ELISA) for detecting antibodies against streptolysin O, an exotoxin produced by Group A Streptococcus. Elevated or rising titers indicate recent streptococcal infection and are essential for diagnosing post-streptococcal sequelae including acute rheumatic fever (Jones criteria) and post-streptococcal glomerulonephritis. The test requires serum samples; acute and convalescent (2-4 weeks apart) with fourfold rise confirms recent infection. Reference range typically <200-250 Todd units/mL (adults), varies by age and population. Primary clinical applications include diagnosis of Group A streptococcal infections, acute rheumatic fever evaluation, post-streptococcal glomerulonephritis diagnosis, differentiation of acute vs. past infection, evaluation of unexplained arthritis or carditis, pediatric inflammatory conditions (PANDAS), and monitoring disease activity in rheumatic fever. Critical safety precautions include proper timing of acute and convalescent samples, awareness of false negatives/positives, clinical correlation for diagnosis, and standard biohazard precautions. Essential test for rheumatology, nephrology, cardiology, and infectious disease practice.
Applicator Sticks
$1.00
Applicator Sticks are single-use medical devices with absorbent tips (cotton, rayon, flocked polyester) on wood, plastic, or paper shafts for collecting clinical specimens (throat, nasal, wound, cervical, urethral, rectal) for microbiological culture, rapid testing, and molecular diagnostics. Sterile individually wrapped or non-sterile bulk formats. Flocked swabs provide >90% specimen release for PCR testing. Primary applications include specimen collection for infection diagnosis, wound care and antiseptic application, gynecological sampling (Pap smears, STI testing), eye/ear specimen collection, laboratory slide preparation, and forensic evidence collection. Critical precautions include single-use only, sterile technique, proper collection method, and biohazard disposal. Essential consumable in all clinical settings.
Blood Grouping kit
$1.00
A Blood Grouping Kit is a Class II medical device (FDA-cleared/CE-marked) containing monoclonal antibodies (Anti-A, Anti-B, Anti-D) and control reagents for determining ABO blood group and Rh factor by agglutination method. The kit includes color-coded reagent vials, reaction cards or slides, mixing sticks, lancets, and capillary pipettes. Test time 2-5 minutes (slide method) or 15-30 minutes (tube method). Interpretation based on agglutination pattern: Anti-A positive = group A; Anti-B positive = group B; both positive = group AB; both negative = group O; Anti-D positive = Rh positive; Anti-D negative = Rh negative. Primary clinical applications include pre-transfusion compatibility testing, prenatal and neonatal testing (Rh incompatibility prevention), preoperative blood typing, blood donor screening, and emergency blood typing. Critical safety precautions include refrigerated storage (2-8°C), proper disposal of lancets in sharps containers, universal precautions for blood samples, and confirmation with reverse typing when possible. Essential kit for transfusion medicine, obstetrics, surgery, and emergency care.
Centrifuge Tubes
$1.00
Centrifuge Tubes are specialized disposable containers (polypropylene) designed to withstand high centrifugal forces (up to 30,000 x g) for separating biological fluids based on density. Available in microcentrifuge sizes (0.2-2.0 mL), conical tubes (15 mL, 50 mL), and larger volumes (100-500 mL). Features include leak-proof screw caps with O-rings (conical tubes), snap caps (microcentrifuge tubes), graduated volume markings, writing areas, and sterile/non-sterile options. Certified RNase/DNase-free, pyrogen-free, and autoclavable. Primary clinical applications include blood component separation (serum/plasma), urine sediment preparation, microbiology sample concentration, molecular biology (DNA/RNA extraction), cell culture processing, protein/enzyme analysis, and viral load testing. Critical safety precautions include never exceeding maximum RCF rating, proper balancing by weight, secure cap tightening, inspection for cracks, and disposal as biohazardous waste. Essential consumable in every clinical, research, and industrial laboratory.
Electric Centrifuge
$1.00
An Electric Centrifuge is a Class I medical device that uses rapid rotation to separate fluids of different densities, essential in clinical laboratories for processing blood, urine, and other biological specimens. Available in benchtop, refrigerated, microcentrifuge, hematocrit, and high-speed models with fixed-angle, swinging-bucket, or vertical rotors. Speed range 1,000-30,000+ RPM with RCF up to 65,000+ x g. Features include brushless induction motor, digital controls, imbalance detection, lid lock safety, and programmable protocols. Primary clinical applications include separation of serum/plasma for chemistry and hematology testing, urine sediment analysis for microscopy, platelet-rich plasma (PRP) preparation for regenerative medicine, concentration of bacteria for microbiology, cytology fluid analysis, blood banking, and molecular biology sample processing. Critical safety precautions include proper balancing of loads (weight matching), use of sealed rotors for biohazardous samples, regular rotor inspection for corrosion or cracks, never exceeding maximum rated speed, and never opening lid during operation. Essential equipment in clinical, research, and teaching laboratories.
H.pylori test kits (Antigen)
$1.00
H.pylori test kits (Antigen) are Class II medical devices (FDA-cleared/CE-marked) for rapid immunochromatographic or enzyme immunoassay detection of Helicobacter pylori antigens in stool specimens, enabling non-invasive diagnosis of active infection and post-treatment eradication confirmation. Test principles use monoclonal or polyclonal antibodies specific to H. pylori antigens, producing visible results in 10-20 minutes (rapid tests) or 1-2 hours (EIA). Sensitivity 90-98%, specificity 92-99% compared to gold standard methods. Primary clinical applications include rapid diagnosis of H. pylori infection in patients with dyspepsia, initial screening in uncomplicated dyspepsia (test-and-treat strategy), confirmation of active infection before therapy, post-treatment eradication confirmation (4-6 weeks after therapy), pediatric testing (preferred non-invasive method), screening in high-risk populations (family history of gastric cancer), and monitoring in patients with peptic ulcer disease or MALT lymphoma. Critical safety precautions include mandatory washout period (4 weeks off antibiotics, 2 weeks off PPIs) to avoid false negatives, proper specimen handling (universal precautions), refrigerated storage of kits (2-30°C), quality control verification, and disposal as biohazardous waste. Essential non-invasive tool for H. pylori management in gastroenterology and primary care.
Rota virus
$1.00
Rota virus rapid tests are immunochromatographic assays (CE-marked, FDA-cleared for some brands) for qualitative detection of rotavirus group A antigens in stool specimens, providing results in 10-20 minutes. The test principle uses monoclonal or polyclonal antibodies against rotavirus antigens (typically VP6 protein) immobilized on membranes, capturing antigens that form a visible line. Sensitivity 90-98%, specificity 95-99% compared to ELISA or PCR. The kit includes individually foil-wrapped test devices, sample diluent, and collection applicators. Primary clinical applications include rapid diagnosis of acute gastroenteritis in children (rotavirus is the leading cause of severe diarrhea in under-5 children), outbreak investigation in daycare centers and schools, hospital infection control and isolation precautions, differential diagnosis of acute diarrhea (viral vs. bacterial vs. parasitic), vaccine effectiveness monitoring and surveillance, assessment of dehydration risk, and evaluation of immunocompromised patients. Critical safety precautions include proper specimen collection (clean container, avoid contamination), biological hazard precautions (all stool potentially infectious), quality control verification, and awareness that a negative test does not rule out other causes of gastroenteritis. Essential tool for pediatric gastroenteritis management, infection control, and public health surveillance.
VDRL Test For Syphilis
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties