Microplate Mixer (MX-M)

WhatsApp Order
The Microplate Mixer (MX-M) is a digital microplate mixer (orbital shaker) designed for uniform mixing of reagents in 96-well and 384-well microplates for clinical diagnostic and research applications . With adjustable speed from 0 to 1000 rpm (2 mm orbit diameter), programmable timer from 0 to 99 hours 59 minutes, and maintenance-free brushless DC motor, this microplate mixer provides consistent, reproducible mixing for ELISA, immunoassays, and molecular diagnostics .
Key features include a non-slip silicone platform that secures microplates during operation, digital display for real-time monitoring of speed and time, soft start and stop to prevent splashing and sample loss, and optional stacking platform for high-throughput applications (up to 4 microplates simultaneously). The universal voltage (100-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion .
For the clinical laboratory scientist and immunology technologist, the Microplate Mixer (MX-M) supports ELISA and immunoassay incubation steps—ensuring consistent mixing of antigens, antibodies, and enzyme conjugates for autoimmune disease testing (ANA, rheumatoid factor), infectious disease serology (HIV, hepatitis), and allergy testing. For the molecular biologist, the Microplate Mixer (MX-M) facilitates mixing of PCR reaction components in 96-well PCR plates before thermal cycling—ensuring uniform distribution of master mix, primers, probes, and template DNA for reliable qPCR results .
With its compact footprint, digital control, and programmable timer, the Microplate Mixer (MX-M) is an essential tool for clinical diagnostic laboratories, immunology laboratories, molecular diagnostics labs, reference laboratories, and pharmaceutical research facilities requiring reliable, reproducible microplate mixing for patient sample testing .
Description

 Microplate Mixer (MX-M)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Orbital Shaking for ELISA and Immunoassay Incubation
  • Primary Use: Provides a digital microplate mixer with orbital shaking (0-1000 rpm) and programmable timer (0-99h59min), designed for uniform mixing of reagents in 96-well and 384-well microplates during ELISA and immunoassay incubation steps .
  • How it helps: For the clinical laboratory scientist and immunology technologist, the Microplate Mixer (MX-M) adjustable speed and orbital diameter (2 mm) ensure consistent, reproducible mixing of antigens, antibodies, and enzyme conjugates—critical for reducing well-to-well variability and improving assay sensitivity. For the patient undergoing autoimmune disease testing (e.g., ANA, rheumatoid factor) or infectious disease serology (HIV, hepatitis), reliable microplate mixing ensures accurate antibody detection that guides appropriate treatment decisions .
2. Homogeneous Mixing for Enzyme-Linked Immunosorbent Assay (ELISA)
  • Primary Use: Used to mix reagents and samples in microplate wells without creating bubbles or cross-contamination, ensuring uniform coating of plates and consistent washing steps .
  • How it helps: For the clinical laboratory scientist, the Microplate Mixer (MX-M) orbital shaking action (2 mm orbit) provides gentle yet thorough mixing that prevents well-to-well variability—reducing false-positive and false-negative results in diagnostic ELISA assays . For the patient, consistent microplate mixing ensures that screening tests for HIV, Lyme disease, and autoimmune conditions produce accurate, interpretable results, minimizing the need for repeat testing.
3. High-Throughput Screening for Diagnostic Laboratories
  • Primary Use: Accommodates up to 4 microplates simultaneously (using stacking platform), enabling high-throughput processing of diagnostic assays in clinical reference laboratories .
  • How it helps: For the laboratory manager and high-throughput screening coordinator, the Microplate Mixer (MX-M) large capacity (4 plates) and continuous operation mode significantly increase sample throughput—reducing turnaround time for large batches of patient samples for infectious disease screening, allergy testing, and autoimmune panels . For the patient, faster processing of diagnostic samples means receiving test results more quickly, enabling earlier diagnosis and treatment initiation.
4. Mixing for PCR Plate Sample Preparation
  • Primary Use: Supports mixing of PCR reaction components in 96-well PCR plates before thermal cycling, ensuring uniform distribution of master mix, primers, probes, and template DNA .
  • How it helps: For the molecular biologist and clinical laboratory scientist, the Microplate Mixer (MX-M) adjustable speed (0-1000 rpm) allows gentle mixing of PCR components without creating bubbles that could interfere with fluorescence detection in qPCR assays . For the patient undergoing molecular diagnostic testing for infectious diseases (COVID-19, influenza, hepatitis), consistent mixing of PCR reactions ensures reliable amplification and accurate test results .

SECONDARY & SUPPORTIVE USES

1. Mixing of Cell-Based Assays: Supports uniform mixing of cell suspensions and reagents in microplates for cytotoxicity, proliferation, and viability assays .
2. Colorimetric and Turbidimetric Assay Mixing: Used to mix chromogenic substrates and turbidimetric reagents for endpoint and kinetic assays in clinical chemistry .
3. Mixing of Bead-Based Multiplex Assays: Supports uniform mixing of magnetic bead suspensions in multiplex immunoassays (e.g., Luminex) for cytokine profiling and autoantibody detection .
4. Hybridization Assays: Used to mix hybridization buffers and probes in microplate-based nucleic acid hybridization assays .
5. Reagent and Standard Curve Preparation: Supports mixing of serial dilutions for standard curve preparation in ELISA and other quantitative immunoassays .
6. Quality Control Sample Mixing: Used to mix QC samples in microplates for clinical laboratory quality assurance programs .
7. Microbial Culture Mixing: Supports uniform mixing of bacterial and yeast cultures in microplates for antimicrobial susceptibility testing and growth curve analysis .
8. Protein Crystallization Screening: Used to mix protein and precipitant solutions in crystallization screening plates .
9. Drug Discovery and High-Throughput Screening: Supports assay development and compound screening in pharmaceutical research laboratories .
10. Veterinary Diagnostic Testing: Used for ELISA and immunoassay mixing in veterinary diagnostic laboratories for infectious disease testing and vaccine response monitoring .
11. Food Safety Testing: Supports immunoassay mixing for food allergen detection and foodborne pathogen screening .
12. Research and Academic Laboratories: Provides reliable microplate mixing for diverse research applications in cell biology, immunology, and molecular biology .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A digital microplate mixer (orbital shaker) with adjustable speed and programmable timer, designed for uniform mixing of reagents in microplates for ELISA, immunoassays, and molecular diagnostics .
  • Designation: MX-M Microplate Mixer, Digital Microplate Mixer, Orbital Microplate Shaker, ELISA Plate Shaker, Microplate Shaker, DLAB Microplate Mixer .
  • Key Components:
    • Shaking Platform: Flat platform with non-slip surface for microplates .
    • Stacking Platform (Optional): Allows stacking of up to 4 microplates for high-throughput mixing .
    • Digital Display: LCD or LED display for speed and time monitoring .
    • Control Panel: Digital controls for speed adjustment and timer programming .
    • DC Motor: Maintenance-free brushless DC motor for quiet, reliable operation .
    • Non-Slip Mat: Silicone or rubber mat prevents plate movement during shaking .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Speed Range: 0-1000 rpm (adjustable) .
  • Orbit Diameter: 2 mm .
  • Timer Range: 0-99 hours 59 minutes (programmable) .
  • Operation Mode: Timed operation or continuous operation .
  • Motor Type: Maintenance-free brushless DC motor .
  • Maximum Capacity: 4 microplates (using stacking platform) .
  • Speed Display: Digital (LCD or LED) .
  • Time Display: Digital (LCD or LED) .
  • Voltage/Frequency: 100-240V, 50/60Hz (universal voltage) .
  • Power: Moderate power consumption for continuous laboratory use .
  • Dimensions (W × D × H): Compact benchtop footprint .
  • Weight: Lightweight for benchtop placement .
  • Noise Level: Low-noise operation suitable for clinical laboratory environments .
  • Compatibility: Accommodates standard 96-well and 384-well microplates, PCR plates, and deep-well plates .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Durable housing with corrosion-resistant platform for long-term laboratory use.
  • Shaking Platform: Non-slip silicone or rubber mat prevents microplate movement during operation; raised edges secure plates in position .
  • Control System: Digital microprocessor control with speed regulation and timer programming .
  • Operation Mode: Timed mode (0-99h59min) for automated workflows; continuous mode for extended operation .
  • Start/Stop: Soft start and stop prevents splashing and sample loss .
  • Speed Accuracy: Maintains set speed under load for consistent mixing .
  • Portability: Compact benchtop footprint for easy integration into laboratory workflows.
  • Maintenance: Brushless DC motor requires no routine maintenance.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable safety standards .
  • Safety Features: Non-slip platform prevents plate movement; soft start prevents splashing; enclosed motor with thermal protection .
  • Electrical Safety: Universal voltage (100-240V, 50/60Hz) for international use; low-voltage DC motor .
  • Noise Control: Low-noise operation minimizes distractions in clinical laboratory settings.
  • GLP Compliance: Digital timer and speed display support GLP documentation .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture.
  • Cleaning: Wipe platform and housing with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; disconnect power before cleaning .
  • Inspection: Inspect power cord for damage before each use; check platform for residue or contamination .
  • Operation: Place microplates securely on platform; use stacking platform for multiple plates .
  • Speed Setting: Start at low speed (200-300 rpm) before increasing to desired speed to prevent splashing .
  • Accessories: Optional stacking platform available for high-throughput applications .
  • Spill Management: If liquid spills onto platform, clean immediately to prevent contamination; disconnect power before cleaning .

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Uniform mixing of reagents in microplates for ELISA, immunoassays, molecular diagnostics, cell-based assays, and high-throughput screening in clinical diagnostic and research laboratories .
  • Clinical Role: Essential microplate mixing equipment in clinical diagnostic laboratories, immunology laboratories, molecular diagnostics labs, reference laboratories, and pharmaceutical research facilities .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources .
  • Plate Security: Ensure microplates are securely seated on non-slip platform; use stacking platform with care to prevent plates from sliding .
  • Speed Selection: Start at low speed (200-300 rpm) and gradually increase to prevent splashing and sample loss .
  • Spill Prevention: Use adhesive seals or caps for plates containing hazardous or infectious materials .
  • Loading Limits: Do not exceed maximum capacity (4 microplates with stacking platform) .
  • Cleaning: Clean spills immediately; disinfect platform if biological materials are involved .
  • Training: Only trained laboratory personnel should operate the MX-M for clinical diagnostic applications .

2. FIRST AID MEASURES

  • Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water .
  • Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel .
  • Mechanical Failure: If unit fails to operate or makes abnormal noise, disconnect power, check for obstruction, contact service if issue persists .
  • Chemical Spill: If corrosive chemicals spill on unit, wipe immediately with appropriate neutralizer, dry thoroughly before reconnecting power .

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn .
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires .
  • Fire Response: Unplug unit immediately; do not use water on electrical fire .