Multi-Purpose Low Speed Centrifuge (DM0408)

WhatsApp Order
The Multi-Purpose Low Speed Centrifuge (DM0408) is a versatile benchtop centrifuge designed for a wide range of clinical diagnostic applications including blood chemistry, urinalysis, coagulation testing, and blood bank workflows. With multiple rotor options accommodating blood collection tubes, urine tubes, conical tubes, and microcentrifuge tubes, this single instrument handles diverse sample processing needs across the clinical laboratory.
For the medical technologist and clinical laboratory scientist, the DM0408 facilitates serum and plasma separation for blood chemistry testing, coagulation studies, and lipid panels. It supports urinalysis sediment preparation for microscopic examination, cerebrospinal fluid cell concentration for neurological diagnostic testing, and blood bank compatibility testing for transfusion medicine. The centrifuge also handles routine clinical chemistry sample preparation for liver function tests, renal function tests, electrolytes, glucose, and lipid profiles.
The DM0408 features reliable motor operation, user-friendly controls for speed and time adjustment, and essential safety features including automatic lid lock and imbalance detection. With interchangeable rotors for different tube types, a compact benchtop footprint suitable for standard laboratory benchtops, and consistent, reliable performance, the DM0408 provides versatile sample processing for routine laboratory workflows supporting patient diagnosis and treatment monitoring.
Description

Multi-Purpose Low Speed Centrifuge (DM0408)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Versatile Low-Speed Blood Component Separation for Clinical Diagnostics
  • Primary Use: Provides a multi-purpose benchtop low-speed centrifuge designed for a wide range of clinical diagnostic applications, enabling separation of whole blood into serum, plasma, and cellular components using various rotor configurations.
  • How it helps: For the medical technologist and clinical laboratory scientist, the DM0408 offers flexibility with multiple rotor options—allowing the same instrument to handle routine blood chemistry tubes, coagulation tubes, and specialized collection tubes. For the patient, versatile equipment ensures consistent sample processing across different test types, reducing turnaround time and improving diagnostic reliability.
2. Urinalysis and Body Fluid Sediment Preparation
  • Primary Use: Accommodates urine tubes and conical tubes for urine sediment preparation, as well as cerebrospinal fluid and other body fluid samples for microscopic examination.
  • How it helps: For the clinical laboratory scientist, the DM0408’s low-speed, gentle centrifugation preserves cellular morphology while effectively concentrating sediment elements—improving microscopic diagnostic accuracy for urinary tract infections, kidney disease, and neurological conditions. For the patient, accurate sediment preparation supports correct diagnosis of conditions such as UTIs, glomerulonephritis, and meningitis.
3. Routine Clinical Chemistry and Coagulation Testing
  • Primary Use: Supports serum and plasma preparation for standard blood chemistry panels including liver function tests, renal function tests, electrolytes, glucose, lipid profiles, and coagulation studies.
  • How it helps: For the clinical chemist, the DM0408’s consistent low-speed operation ensures optimal separation without hemolysis or cellular damage—improving the accuracy of routine chemistry and coagulation testing. For the patient, high-quality sample preparation reduces the need for repeat blood draws and ensures reliable diagnostic results.
4. Blood Bank and Compatibility Testing
  • Primary Use: Supports blood bank workflows including cross-matching, antibody screening, and blood component preparation for transfusion medicine.
  • How it helps: For the blood bank technologist, the DM0408 provides reliable sample preparation for compatibility testing—ensuring safe blood transfusions through proper separation of donor and recipient blood components. For the patient requiring blood transfusion, accurate compatibility testing prevents transfusion reactions and ensures safe blood product administration.
5. Multi-Purpose General Laboratory Processing
  • Primary Use: Serves as a general-purpose centrifuge for routine clinical laboratory workflows including aliquot preparation, quality control sample processing, and basic research applications.
  • How it helps: For the laboratory manager, the DM0408’s versatility reduces the need for multiple dedicated centrifuges—saving bench space and equipment costs while handling a wide range of daily laboratory tasks. For the patient, efficient multi-purpose processing supports timely diagnosis and treatment across multiple clinical departments.

SECONDARY & SUPPORTIVE USES

1. Blood Chemistry Sample Preparation: Used for serum and plasma separation for routine chemistry panels, electrolytes, enzymes, and cardiac biomarkers.
2. Coagulation Testing Preparation: Supports platelet-poor plasma preparation for PT, PTT, fibrinogen, and other coagulation studies.
3. Urinalysis Sediment Preparation: Used for concentration of urine sediment for microscopic examination and culture preparation.
4. Cerebrospinal Fluid (CSF) Processing: Used for cell concentration and sediment preparation for CSF analysis in neurology diagnostics.
5. Pleural, Peritoneal, and Synovial Fluid Analysis: Supports cell concentration and sediment preparation for body fluid cytology and chemistry.
6. Blood Bank and Transfusion Medicine: Used for cross-matching, antibody screening, and blood component preparation.
7. Routine Hematology: Used for sample preparation in complete blood count (CBC) and differential analysis workflows.
8. Quality Control Sample Preparation: Supports preparation of QC samples for clinical laboratory quality assurance programs.
9. Aliquot Preparation: Used for preparing sample aliquots for secondary testing, storage, and reference laboratory send-outs.
10. Basic Research and Academic Laboratories: Used in educational and research settings for routine centrifugation needs.
11. Veterinary Diagnostic Laboratory: Supports sample processing for animal health testing and veterinary diagnostics.
12. Blood Collection Tube Processing: Compatible with standard blood collection tubes for routine clinical workflows.
13. General Laboratory Applications: Suitable for a wide range of routine centrifugation tasks in clinical and research settings.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A multi-purpose benchtop low-speed centrifuge designed for a wide range of clinical diagnostic applications including blood chemistry, urinalysis, coagulation testing, and blood bank workflows.
  • Designation: DM0408 Multi-Purpose Low Speed Centrifuge, Low Speed Multi-Purpose Centrifuge, Benchtop Clinical Centrifuge, General Purpose Centrifuge, DLAB DM0408, Laboratory Centrifuge.
  • Key Components:
    • Multiple Rotor Options: Accommodates various tube sizes including blood collection tubes, urine tubes, conical tubes, and microcentrifuge tubes.
    • Motor: Reliable motor for consistent low-speed operation.
    • Control: Digital or analog controls for speed and time settings.
    • Display: Speed and time display.
    • Safety Features: Lid lock, imbalance detection.

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Maximum Speed: Low speed range suitable for clinical applications.
  • Maximum RCF (Relative Centrifugal Force): Appropriate for serum/plasma separation and urine sediment preparation.
  • Capacity: Accommodates multiple tube types and sizes via interchangeable rotors.
  • Rotor Options: Fixed-angle and swing-out rotors for blood tubes, urine tubes, and conical tubes.
  • Run Time: Programmable with continuous operation option.
  • Motor Type: Durable AC or DC motor.
  • Noise Level: Quiet operation suitable for clinical laboratory environments.
  • Power Requirements: Standard laboratory power supply.
  • Dimensions: Compact benchtop footprint.
  • Weight: Moderate weight for benchtop stability.

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Durable housing with corrosion-resistant rotor chamber.
  • Control: User-friendly interface for speed and time adjustment.
  • Rotor Exchange: Easy rotor change for different applications.
  • Operation Modes: Timed operation and continuous operation.
  • Safety Features: Automatic lid lock, imbalance detection.
  • Portability: Benchtop design suitable for routine laboratory use.
  • Maintenance: Regular cleaning and rotor inspection as per standard protocols.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: Class II medical device for clinical diagnostic use.
  • Safety Certifications: CE certified or equivalent.
  • Safety Features: Lid safety interlock, imbalance detection, over-speed protection.
  • Electrical Safety: Complies with laboratory equipment electrical standards.
  • Noise Control: Low noise operation for comfortable laboratory environment.

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry benchtop; ensure adequate ventilation.
  • Cleaning: Wipe exterior with soft, damp cloth; clean rotor chamber after each use.
  • Rotor Maintenance: Remove and clean rotors with mild detergent; dry thoroughly before reinstallation.
  • Inspection: Inspect rotors for cracks or damage before each use; replace if compromised.
  • Power Cord: Inspect power cord for damage before each use.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Multi-purpose low-speed sample processing for blood chemistry, urinalysis, coagulation testing, blood bank compatibility testing, and general laboratory workflows.
  • Clinical Role: Essential sample preparation equipment in clinical diagnostic laboratories, hospital laboratories, physician office laboratories, blood banks, and research laboratories.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Rotor Balancing: Ensure rotor is balanced with tubes of equal weight; imbalance may cause excessive vibration.
  • Lid Security: Ensure lid is securely closed before operation.
  • Rotor Inspection: Inspect rotors for cracks or damage before each use; do not use damaged rotors.
  • Tube Compatibility: Use only tubes rated for low-speed centrifugation.
  • Rotor Loading: Load tubes symmetrically; never run rotor with unbalanced loads.
  • Cleaning: Clean spills immediately; disinfect if biological materials are involved.
  • Placement: Place on stable, level surface; ensure adequate ventilation.
  • Training: Only trained laboratory personnel should operate the centrifuge.

2. FIRST AID MEASURES

  • Tube Breakage: If tube breaks during operation, stop centrifuge immediately, allow rotor to stop fully, carefully remove fragments using forceps, disinfect rotor and chamber.
  • Sample Splash: If biological sample splashes, disinfect area immediately with appropriate disinfectant.
  • Imbalance Shutdown: If imbalance shutdown occurs, rebalance rotor equally, restart centrifuge.

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic and electronic components may burn.
  • Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for electrical fires.
  • Fire Response: Unplug centrifuge immediately; do not use water on electrical fire.