High Shear Homogenizer (D-500)
WhatsApp Order
The High Shear Homogenizer is a powerful benchtop rotor-stator homogenizer featuring a 500W AC carbon brush motor, variable speed control (10,000-30,000 rpm with 6 speed settings), interchangeable autoclavable 316L stainless steel dispersing shafts, and a wide working volume range of 10-40,000 mL, designed for rapid homogenization, dispersion, and emulsification of biological tissues, pharmaceutical formulations, and chemical samples in clinical diagnostic, pharmaceutical, and research laboratories .
Key features include a 500W high-power motor handling samples up to 10,000 mPa·s viscosity , 6-stage adjustable speed dial for precise control of homogenization intensity , interchangeable dispersing shafts ( High Shear Homogenize/1 for solid-liquid mixing and tissue homogenization; High Shear Homogenize/2 for emulsification and cream preparation) , fully autoclavable 316L stainless steel construction with PTFE seals for chemical resistance and contamination prevention, automatic overload protection and smooth motor start for safety and extended motor life, emergency stop safety switch for immediate shutdown, and compact (75 × 75 × 280 mm) and lightweight (1.7 kg) design for benchtop or stand-mounted operation . An optional H-600 stand enables hands-free, stationary operation .
For the histotechnologist and pathologist, the High Shear Homogenize processes tough tissue samples such as muscle, liver, breast, and other organs in seconds—enabling rapid preparation of homogenized specimens for histological examination, immunohistochemistry, and diagnostic pathology . For the molecular biologist, it supports cell disruption and nucleic acid extraction for PCR-based infectious disease testing, genetic screening, and oncology biomarker detection. For the pharmaceutical QC chemist, it processes high-viscosity formulations, creams, and ointments for stability testing and quality release.
For the patient undergoing biopsy for suspected cancer, inflammatory disease, or infectious condition, the High Shear Homogenize rapid tissue homogenization reduces turnaround time for diagnostic results, enabling earlier diagnosis and treatment initiation . For patients requiring pharmaceutical products, consistent formulation testing ensures that medications, topical creams, and biological products meet quality standards for safety and efficacy. For patients requiring molecular diagnostic testing, efficient cell lysis and nucleic acid extraction ensure accurate PCR and sequencing results that guide appropriate treatment decisions across clinical pathology, molecular diagnostics, infectious disease testing, and pharmaceutical quality control applications.
Categories: LABORATORY EQUIPMENT AND SUPPLIES, Lab Consumables
Tags: Cell Lysis, Clinical Laboratory Equipment, D-500 Homogenizer, Dispersion, DLAB High Shear Homogenize, Emulsification, High Shear Homogenizer, High Speed Homogenizer, Histopathology Equipment, Laboratory Homogenizer, Pharmaceutical QC Equipment, Rotor-Stator Homogenizer, Sample Preparation, Tissue Homogenizer
Description
High Shear Homogenizer
PRIMARY CLINICAL & DIAGNOSTIC USES
1. High-Performance Tissue Homogenization for Histopathology
-
Primary Use: Provides a benchtop high shear homogenizer with a powerful 500W motor, variable speed control (10,000-30,000 rpm with 6 speed settings), interchangeable 316L stainless steel dispersing shafts, and a wide working volume range of 10-40,000 mL for rapid homogenization of biological tissues, organs, and cells for pathological analysis .
-
How it helps: For the histotechnologist and pathologist, the High Shear Homogenize processes tough tissue samples such as muscle, liver, breast, and other organs in seconds—enabling rapid preparation of homogenized specimens for histological examination, immunohistochemistry, and diagnostic pathology. The high shear rotor-stator mechanism (up to 36 m/sec linear velocity) ensures complete tissue disruption even for fibrous samples . For the patient, faster tissue processing reduces turnaround time for biopsy results, enabling earlier diagnosis of cancers, inflammatory conditions, and infectious diseases.
2. Sample Preparation for Molecular Diagnostics and PCR
-
Primary Use: Used for cell disruption, lysis, and homogenization of biological samples before nucleic acid extraction (DNA/RNA) and protein purification for molecular diagnostic workflows .
-
How it helps: For the molecular biologist and clinical laboratory scientist, the High Shear Homogenize efficiently lyses cells and releases intracellular contents from animal and plant tissues, enabling high-yield extraction of nucleic acids and proteins from biopsy specimens, surgical resections, and cultured cells. The fully autoclavable 316L stainless steel dispersing shafts prevent sample cross-contamination . For the patient undergoing genetic testing for hereditary disorders, infectious diseases, or oncology biomarkers, efficient cell lysis ensures accurate PCR and sequencing results that guide treatment decisions.
3. High-Viscosity Sample Processing for Biopharmaceutical Testing
-
Primary Use: Capable of processing samples with viscosity up to 10,000 mPa·s, enabling homogenization and emulsification of viscous biological fluids, creams, ointments, and pharmaceutical formulations for quality control and formulation testing .
-
How it helps: For the pharmaceutical quality control chemist and formulation scientist, the High Shear Homogenize high torque 500W motor and wide speed range provide efficient processing of high-viscosity samples—ensuring consistent emulsification of creams, lotions, and ointments for stability testing and quality release. For the patient, consistent pharmaceutical formulation testing ensures that medications, topical creams, and biological products meet quality standards for safety and efficacy.
4. Pathological Analysis of Large-Volume Biopsy and Surgical Specimens
-
Primary Use: Facilitates homogenization of large-volume biopsy specimens and surgical resection tissues (up to 40,000 mL) for pathological analysis, enzyme activity assays, and biomarker quantification .
-
How it helps: For the pathologist and clinical researcher, the D-500’s wide working volume range (10-40,000 mL) allows homogenization of both small needle biopsies and large surgical resection specimens—enabling comprehensive analysis of limited diagnostic material as well as bulk tissue processing. For the patient, the ability to process a wide range of specimen volumes reduces the need for repeat procedures and enables complete pathological evaluation of removed tissues.
5. Emulsification and Dispersion for Quality Control Testing
-
Primary Use: Used for emulsification of lipid-containing samples, dispersion of active pharmaceutical ingredients, and homogenization of complex biological fluids for clinical chemistry and pharmaceutical quality control testing .
-
How it helps: For the clinical chemist and pharmaceutical QC scientist, the High Shear Homogenize high shear rotor-stator mechanism (up to 79 dB(A) noise level) creates stable emulsions and dispersions of lipid-rich samples, lipoproteins, API suspensions, and other complex formulations—enabling accurate measurement of active ingredients, particle size distribution, and formulation stability . For the patient, consistent sample emulsification ensures reliable quality control results that guide pharmaceutical manufacturing and clinical laboratory testing.
SECONDARY & SUPPORTIVE USES
1. Biopharmaceutical Research and Development: Used for cell lysis, protein extraction, and formulation development in biopharmaceutical discovery and manufacturing workflows.
2. Gene Research and Genetic Analysis: Supports tissue homogenization for DNA/RNA extraction in clinical genetics laboratories and molecular diagnostics .
3. Active Pharmaceutical Ingredient (API) Extraction: Facilitates extraction of active pharmaceutical ingredients from tablets, pills, and other solid dosage forms for content uniformity testing .
4. Oil-Water Emulsification for Cosmetic and Pharmaceutical Testing: Supports preparation of emulsions and creams for quality control testing of cosmetic and pharmaceutical products .
5. Oral Solid Dosage Form Disintegration Testing: Used for homogenization of tablets and capsules for dissolution testing and API release analysis.
6. Parenteral Drug Product Testing: Supports homogenization of injectable formulations for particle size analysis and stability studies.
7. Dairy and Food Homogenization: Used for homogenization of dairy products and food samples for nutritional labeling and safety testing .
8. Nanomaterial Dispersion for Diagnostic Assays: Helps disperse nanoparticles and microparticles for diagnostic assay development and quality control .
9. Polymerization and Chemical Reaction Preparation: Supports mixing and homogenization in chemical reaction preparation for polymer synthesis.
10. Paint, Ink, and Coating Homogenization: Used for dispersion of pigments and additives in paint, ink, and coating manufacturing quality control .
11. Fine Chemicals and Pesticide Testing: Used for homogenization of chemical samples in fine chemical and pesticide quality control laboratories.
12. Active Ingredient Extraction from Natural Products: Supports extraction of active compounds from botanical materials for nutraceutical and pharmaceutical development.
13. Environmental Sample Processing: Helps homogenize soil, water, and environmental samples for pollutant analysis and environmental monitoring .
14. Prospecting and Mining Sample Preparation: Supports homogenization of geological and mineral samples for element analysis and mineral exploration .
15. Veterinary Diagnostic Laboratory: Processes tissue and fluid samples for animal health testing and infectious disease diagnosis.
16. Research and Academic Laboratories: Provides high shear homogenization for diverse research applications in cell biology, biochemistry, and biotechnology.
17. Nanoparticle Synthesis and Dispersion: Supports dispersion of nanoparticles and microparticles for drug delivery research and formulation development.
18. Textile Chemical Quality Control: Used for homogenization of textile auxiliaries and finishing agents for quality testing .
19. Cosmetics Formulation Development: Supports formulation of creams, lotions, gels, and other cosmetic products.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A benchtop high shear homogenizer (rotor-stator homogenizer) with variable speed control (10,000-30,000 rpm, 6 speed levels), interchangeable autoclavable dispersing shafts, and wide working volume range, designed for rapid homogenization, dispersion, and emulsification of biological tissues, pharmaceutical formulations, and chemical samples in clinical diagnostic, pharmaceutical, and research laboratories .
-
Designation: High Shear Homogenizer, High Shear Homogenizer, D-500 Homogenizer, DLAB High Shear Homogenize, Laboratory Homogenizer, High Speed Homogenizer, Bench-top Homogenizer .
-
Key Components:
o Drive Motor: AC carbon brush motor, 500W input power .
o Speed Control: 6-stage adjustable speed dial (10,000-30,000 rpm) .
o Dispersing Shafts: Interchangeable 316L stainless steel shafts with PTFE seals (DS-500/1 for solid-liquid mixing; DS-500/2 for emulsification) .
o Stand: H-600 stand for hands-free, stationary operation .
o Housing: Compact benchtop design, 75x75x280 mm dimensions .
o Safety Features: Automatic overload protection, smooth motor start, emergency stop safety switch .
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Speed Range: 10,000-30,000 rpm (6 speed settings) .
-
Maximum Rotor Linear Velocity: 22.7-36 m/sec .
-
Working Volume: 10-40,000 mL (10-5000 mL with DS-500/1 or DS-500/2 shafts) .
-
Maximum Viscosity: 10,000 mPa·s .
-
Motor Type: AC carbon brush motor .
-
Motor Power: 500W .
-
Speed Display: Rotary dial with 6 positions .
-
Noise Level: ≤79 dB(A) .
-
Dispersing Shaft Material: SS 316L stainless steel (corrosion-resistant, autoclavable) .
-
Seal Material: PTFE (chemically inert, autoclavable) .
-
pH Range: 2-13 .
-
Fineness: Suspensions & Emulsion 10-15 µm & 1-10 µm .
-
Power Requirements: 110-120V/60Hz or 220-240V/50-60Hz (universal voltage) .
-
Dimensions (L × W × H): 75 × 75 × 280 mm (drive only) .
-
Weight: 1.7 kg .
-
Operating Temperature: 0-40°C .
-
Permissible Ambient Humidity: up to 85% RH .
-
Protection Class: IP20 .
-
Safety Features: Automatic overload protection; smooth motor start; emergency stop safety switch; thermal fuse for overload protection .
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Construction: Compact benchtop design with lightweight (1.7 kg) drive unit; ergonomic grip for handheld operation; optional H-600 stand for hands-free, stationary use .
-
Dispersing Shafts: Interchangeable shafts with tool-free attachment; fully autoclavable 316L stainless steel construction; PTFE seal rings for chemical resistance; available in two configurations: DS-500/1 for solid-liquid mixing, DS-500/2 for emulsification .
-
Principle: Rotor-stator mechanism where samples are drawn into the core of the homogenizer by a rotor turning at high speed (10,000-30,000 rpm), then forced through narrow slits in the stator where high shear forces cause rapid tissue disruption, emulsification, and cell lysis .
-
Control: 6-stage rotary speed dial with positions for precise adjustment of homogenization intensity .
-
Operation Modes: Handheld mode for manual operation; H-600 stand mode for hands-free, stationary operation .
-
Safety Features: Automatic overload protection extends motor lifespan ; smooth motor start prevents splashing and sample loss ; emergency stop safety switch for immediate shutdown .
-
Portability: Compact (75 × 75 × 280 mm) and lightweight (1.7 kg) for easy transport between workstations and benchtop storage.
-
Maintenance: Dispersing shafts are easily disassembled without specialized tools for cleaning and sterilization; AC carbon brush motor requires periodic brush replacement .
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: General laboratory equipment for research and in vitro diagnostic use; meets applicable laboratory safety standards .
-
Safety Features: IP20 protection rating provides protection against solid objects >12mm; automatic overload protection mechanism maximizes motor working life; smooth motor start prevents splashing and sample loss; emergency stop safety switch for immediate shutdown .
-
Electrical Safety: Universal voltage (100-240V, 50/60Hz) for international use; 500W power consumption; earthed power connection recommended; thermal fuse for overload protection .
-
Noise Control: ≤79 dB(A) operation level; insulated motor housing keeps motor noise to safe, approved level .
-
Material Safety: SS 316L stainless steel (corrosion-resistant, biocompatible, autoclavable); PTFE seals (chemically inert, biocompatible, autoclavable) .
-
Sterilization Compatibility: Dispersing shafts are fully autoclavable at 121°C for aseptic applications .
-
Certifications: CE certified; meets applicable safety standards .
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store drive unit on clean, dry benchtop or in designated storage area; dispersing shafts should be cleaned and dried before storage; H-600 stand provides convenient storage for drive unit and shaft during idle periods .
-
Cleaning: Dispersing shafts: disassemble without tools, rinse with distilled water, clean with mild detergent, rinse thoroughly; autoclavable at 121°C for sterilization . Drive unit: wipe exterior with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface disinfection; do not immerse drive unit in liquid; disconnect power before cleaning.
-
Inspection: Inspect dispersing shafts for damage (bent shafts, worn PTFE seals, corrosion) before each use; verify shaft is securely attached to drive unit; inspect power cord for damage before each use; check stand stability before mounting drive unit .
-
Operation: Secure sample container in stand or clamp; select appropriate dispersing shaft for sample volume and viscosity; attach shaft to drive unit; immerse shaft into sample (avoid touching container bottom); select speed setting (1-6); start motor; process sample until homogenized (typically 10-30 seconds for tissue) .
-
Shaft Selection: Use High Shear Homogenize/1 shaft for solid-liquid mixing, tissue homogenization, and general dispersion; use High Shear Homogenize/2 shaft for emulsification, cream preparation, and oil-water mixing .
-
Speed Selection: Use lower speeds (position 1-2) for soft tissues and cell suspensions; use medium speeds (position 3-4) for muscle, liver, and organ tissues; use higher speeds (position 5-6) for tough tissues, fibrous materials, high-viscosity samples, and emulsion preparation .
-
Aseptic Technique: For sterile applications, use autoclaved dispersing shafts and perform homogenization in biosafety cabinet; avoid aerosol generation.
-
Stand Use: For hands-free operation, mount drive unit on H-600 stand; secure stand on stable benchtop; clamp sample container in position; lower drive unit so shaft is properly immersed; operate with both hands free .
-
Spill Management: If sample spills onto drive unit, disconnect power immediately, clean thoroughly with appropriate disinfectant, allow to dry before reuse.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: High shear homogenization, dispersion, and emulsification of biological tissues (muscle, liver, breast, organs), cells, clinical specimens, pharmaceutical formulations, and chemical samples for histopathology, molecular diagnostics, cytology, clinical chemistry, pharmaceutical quality control, and research laboratories .
-
Clinical Role: Essential sample preparation equipment in histopathology laboratories, molecular diagnostics labs, clinical chemistry laboratories, microbiology labs, cytology labs, pharmaceutical QC laboratories, biotechnology research facilities, and academic research institutions .
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Electrical Safety: Disconnect power before cleaning or changing dispersing shafts; do not immerse drive unit in liquid; keep power cord away from heat sources and sharp edges; use only properly grounded electrical outlets; use emergency stop safety switch for immediate shutdown if needed .
-
Aerosol Generation: High-speed homogenization may generate aerosols; use appropriate containment (biosafety cabinet, fume hood) when processing infectious materials, hazardous chemicals, or volatile solvents.
-
Personal Protective Equipment: Wear appropriate PPE—laboratory coat, safety glasses/face shield, gloves—when operating homogenizer; use cut-resistant gloves when handling and cleaning dispersing shafts.
-
Shaft Selection: Select appropriate dispersing shaft for sample volume and viscosity; using smaller shaft in larger volume may reduce efficiency; using larger shaft in smaller volume may cause splashing and sample loss.
-
Sample Container: Use appropriate container (beaker, vessel) with sufficient diameter and depth for dispersing shaft; avoid using flimsy or uncapped tubes; clamp container securely when using stand-mounted operation.
-
Operation Precautions: Never operate homogenizer with shaft out of liquid; this may damage PTFE seals and cause overheating. Ensure shaft is fully immersed before starting motor. Do not process samples containing hard particles (glass, metal, hard plastics) that may damage rotor-stator assembly .
-
Noise Exposure: At ≤79 dB(A), noise level is below occupational exposure limits; however, extended operation may cause fatigue; use hearing protection if operating for prolonged periods.
-
Sharp Edges: Dispersing shafts contain sharp rotor-stator edges; handle with care to avoid cuts.
-
Cleaning: Clean dispersing shafts immediately after use to prevent dried sample residue; do not use abrasive cleaners on shafts.
-
Training: Only trained laboratory personnel should operate the High Shear Homogenizer for clinical diagnostic applications.
2. FIRST AID MEASURES
-
Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
-
Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell, sparking), press emergency stop safety switch, disconnect power immediately; do not attempt to operate; contact service personnel .
-
Mechanical Failure: If unit fails to operate, makes abnormal noise, or vibrates excessively, disconnect power, inspect shaft for damage or debris, contact service if issue persists.
-
Sharp Edge Injury: If cut by dispersing shaft, clean wound thoroughly with soap and water, apply appropriate dressing, seek medical attention if bleeding persists or wound is deep.
-
Chemical Spill: If corrosive chemicals spill on unit, disconnect power immediately, wipe with appropriate neutralizer, dry thoroughly before reconnecting power.
3. FIRE FIGHTING MEASURES
-
Flammability: Plastic housing and electrical components may burn; AC carbon brush motor may produce sparks during normal operation.
-
Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires.
-
Fire Response: Press emergency stop safety switch, unplug unit immediately; do not use water on electrical fire; if sparks or smoke are observed during normal operation, discontinue use and service unit .
Related products
Anti-Streptol Olysin O Titer (ASOT)
$24.23
Anti-Streptol Olysin O Titer (ASOT) is a quantitative or semi-quantitative serological test (latex agglutination, turbidimetry, nephelometry, or ELISA) for detecting antibodies against streptolysin O, an exotoxin produced by Group A Streptococcus. Elevated or rising titers indicate recent streptococcal infection and are essential for diagnosing post-streptococcal sequelae including acute rheumatic fever (Jones criteria) and post-streptococcal glomerulonephritis. The test requires serum samples; acute and convalescent (2-4 weeks apart) with fourfold rise confirms recent infection. Reference range typically <200-250 Todd units/mL (adults), varies by age and population. Primary clinical applications include diagnosis of Group A streptococcal infections, acute rheumatic fever evaluation, post-streptococcal glomerulonephritis diagnosis, differentiation of acute vs. past infection, evaluation of unexplained arthritis or carditis, pediatric inflammatory conditions (PANDAS), and monitoring disease activity in rheumatic fever. Critical safety precautions include proper timing of acute and convalescent samples, awareness of false negatives/positives, clinical correlation for diagnosis, and standard biohazard precautions. Essential test for rheumatology, nephrology, cardiology, and infectious disease practice.
Coagulation Analyzer
$1.00
A Coagulation Analyzer is a compact, automated instrument designed for performing essential tests that evaluate the blood's clotting ability. It accurately measures key parameters such as Prothrombin Time (PT/INR), Activated Partial Thromboplastin Time (aPTT), Thrombin Time, and Fibrinogen, which are critical for monitoring anticoagulant therapy (warfarin, heparin), diagnosing bleeding disorders, and assessing surgical risk. With its photometric detection and user-friendly operation, it delivers reliable results for small to medium-volume laboratories, clinics, and hospital wards. Its role in ensuring safe and effective patient management in thrombosis and hemostasis makes it a vital tool in clinical diagnostics.
Cover Glass
$1.00
Cover Glass (coverslips) are thin, transparent glass or plastic squares (e.g., 18×18 mm, 22×22 mm) or rectangles (22×30 mm, 24×50 mm) used to cover specimens on microscope slides for microscopic examination. Available in thickness No. 1 (0.13-0.16 mm) and No. 1.5 (0.16-0.19 mm) for optimal microscopy. Made from optical glass with high light transmission (>90%), refractive index 1.52 matching immersion oil. Packaged in boxes of 100-1000, interleaved with paper to prevent scratching. Primary clinical applications include covering blood films for manual differential counts and malaria diagnosis, wet mount preparations of urine sediment and vaginal secretions, histopathology and cytology slides, Gram-stained bacterial smears, semen analysis, KOH preparations for fungal elements, and India ink preparations for Cryptococcus. Critical safety precautions include handling with forceps (sharp edges), disposing of broken coverslips in sharps containers, avoiding fingerprints on optical surface, and proper disposal of biohazard-contaminated coverslips. Essential consumable in every clinical laboratory performing microscopy.
ESR Tubes Glass
$1.00
ESR Tubes Glass are specialized glass tubes (300 mm length, 2.55 mm bore diameter, graduated 0-200 mm in 1 mm intervals) meeting ICSH and CLSI Westergren specifications for measuring erythrocyte sedimentation rate, a non-specific marker of inflammation. Used with citrated or diluted EDTA blood, filled to exactly 200 mm, placed vertically in Westergren stand, and read at 60 minutes. Primary clinical applications include determination of ESR for diagnosing and monitoring inflammatory conditions (infections, autoimmune disorders, malignancies), monitoring disease activity in rheumatoid arthritis, assessment of temporal arteritis and polymyalgia rheumatica, evaluation of infection and inflammatory response, screening for occult inflammatory conditions, and monitoring chronic inflammatory diseases (SLE, IBD, vasculitis). Critical safety precautions include handling glass tubes carefully to avoid breakage (sharps hazard), proper disposal in sharps containers as biohazardous waste, ensuring vertical alignment and constant temperature (18-25°C), reading at exactly 60 minutes, and avoiding air bubbles and vibration. Essential consumable for reference Westergren ESR testing in clinical laboratories.
Fridge Thermometer
$1.00
A Fridge Thermometer is a precision temperature monitoring device designed for continuous use inside medical and laboratory refrigerators and freezers. Its primary role is to safeguard the potency of vaccines, medications, and biological samples by ensuring storage temperatures remain within a critical specified range (e.g., +2°C to +8°C). Available in analog or digital formats, accurate models with memory functions are essential for compliance with cold chain protocols, requiring daily monitoring, logging, and regular calibration. It is a fundamental quality control tool in pharmacies, clinics, immunization centers, and laboratories.
Rheumatoid factor
$1.00
Rheumatoid Factor (RF) testing is a quantitative or semi-quantitative serological assay (nephelometry, turbidimetry, latex agglutination, or ELISA) for detecting autoantibodies against the Fc portion of immunoglobulin G, primarily of the IgM isotype. RF is a key marker in the ACR/EULAR classification criteria for rheumatoid arthritis, with sensitivity 60-80% and specificity 70-90%. Test requires serum samples; results reported in IU/mL (reference <15-20 IU/mL) or titer. Primary clinical applications include diagnosis and classification of rheumatoid arthritis, prognostic assessment (high-titer RF correlates with severe, erosive disease), differential diagnosis of inflammatory arthritis, monitoring disease activity, diagnosis of Sjögren's syndrome, evaluation of mixed cryoglobulinemia (hepatitis C-associated), and assessment of other autoimmune and chronic inflammatory conditions. Critical safety precautions include awareness of false positives (other autoimmune diseases, chronic infections, healthy elderly), false negatives (seronegative RA 20-30%), need for clinical correlation, and anti-CCP antibody testing to improve diagnostic accuracy. Essential test for rheumatology practice, autoimmune disease evaluation, and differential diagnosis of inflammatory arthritis.
Salmonella Typhi Test Peratop
$1.00
The Salmonella typhi test peratop is a CE-marked rapid immunochromatographic assay for qualitative detection of IgG and IgM antibodies to Salmonella enterica serotype Typhi in human serum, plasma, or whole blood, providing results in 15-20 minutes. The test uses recombinant S. typhi antigens immobilized on a membrane to capture specific antibodies, with separate lines for IgG and IgM interpretation. The kit includes individually foil-wrapped test cassettes, sample diluent, disposable pipettes, and package insert. Primary clinical applications include rapid diagnosis of typhoid fever in endemic regions (Indian subcontinent, Southeast Asia, Africa, South America), differentiation of acute (IgM positive) from past infection (IgG only), outbreak investigation and control, screening in febrile patients, travel medicine assessment, antibiotic stewardship, and maternal/child health in endemic areas. Critical safety precautions include proper specimen handling (universal precautions), quality control verification, awareness of window period (repeat testing if early infection suspected), and clinical correlation of results. Essential rapid test for typhoid fever diagnosis in resource-limited and endemic settings.
Vacutainer (EDTA/PLAIN)
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties