Portable Polarized Dissolved Oxygen Meter – Single Parameter (DDO10)
WhatsApp Order
The Portable Polarized Dissolved Oxygen Meter – Single Parameter (DDO10) is a rugged, handheld instrument designed for accurate, on-site dissolved oxygen analysis. Utilizing a polarographic probe technology, it measures DO concentration (0.00~20.00 mg/L) and percent saturation (0.0~200.0%) with automatic compensation for temperature, barometric pressure, and manual salinity changes.
Featuring a 3.5-inch TFT color screen and a user-friendly UI interface, the Portable Polarized Dissolved Oxygen Meter – Single Parameter (DDO10) simplifies field water quality testing. It stores up to 3000 data sets, supporting GLP-compliant documentation, and its rechargeable lithium battery with a Type-C port ensures convenient power for mobile use. The system includes a polarographic DO probe (DDO01-2M-H), maintenance solutions, membrane caps, and a hard carrying case, making it ready for deployment.
For the water quality specialist, the Portable Polarized Dissolved Oxygen Meter – Single Parameter (DDO10) is essential for monitoring dissolved oxygen in purified water systems (WFI, dialysis water), assessing aeration in wastewater treatment, and verifying water quality in pharmaceutical production and hospital facilities. For the patient, this rigorous monitoring helps ensure that water used in dialysis and other medical treatments meets stringent safety standards, preventing potential harm from improperly treated water. The meter provides quick, reliable, and verifiable results for any application requiring critical DO measurement.
Description
Portable Polarized Dissolved Oxygen Meter – Single Parameter (DDO10)
PRIMARY CLINICAL & DIAGNOSTIC USES
1. Rapid Assessment of Dissolved Oxygen in Biological and Environmental Samples
-
Primary Use: Provides a portable, single-parameter dissolved oxygen meter utilizing polarographic probe technology to measure DO concentration (0.00~20.00 mg/L) and oxygen saturation (0.0~200.0%) in aqueous samples, with integrated temperature, barometric pressure, and salinity compensation for accurate readings.
-
How it helps: For the clinical laboratory scientist and environmental health specialist, the DDO10 enables rapid, on-site determination of dissolved oxygen levels in various aqueous matrices relevant to healthcare environments, such as purified water systems, dialysis water, and biological oxygen demand (BOD) samples in wastewater treatment. The 3.5-inch TFT color screen provides an intuitive, easy-to-read interface for efficient fieldwork. For the patient, accurate measurement of dissolved oxygen in water used for dialysis or other medical processes is a critical parameter for ensuring water quality and preventing adverse events related to improper water treatment.
2. Monitoring of Water Quality in Critical Healthcare Systems
-
Primary Use: Designed to monitor dissolved oxygen levels in purified water systems, water-for-injection (WFI) loops, and wastewater treatment facilities associated with hospitals and pharmaceutical manufacturing.
-
How it helps: For the facility water quality manager and infection control officer, the DDO10’s IP57 dustproof and waterproof rating, along with its rechargeable lithium battery and Type-C charging, makes it ideally suited for spot-checking water quality at various points in a distribution system. The auto-calibration and data storage functions support rigorous quality assurance documentation as required by GLP standards. For the patient, continuous and accurate monitoring of water treatment processes helps prevent healthcare-associated infections linked to waterborne pathogens.
SECONDARY & SUPPORTIVE USES
1. Aquaculture and Zebrafish Facility Management: Used to monitor dissolved oxygen levels in aquatic animal housing facilities within research institutions.
2. Pharmaceutical Bioprocess Support: Verifies DO levels in small-scale bioreactors and shaker flasks used in pharmaceutical R&D.
3. Wastewater Treatment Monitoring: Measures dissolved oxygen in hospital wastewater treatment systems to assess treatment efficacy and aeration basin performance.
4. Boiler Water and Steam Generation Monitoring: Checks scavenger residuals and corrosion potential in boiler water systems.
5. Environmental and Surface Water Monitoring: Portable format is ideal for field studies measuring DO in natural water bodies to assess ecosystem health.
6. Educational and Laboratory Training: Serves as a practical teaching tool for demonstrating electrochemistry and water quality measurement principles.
KEY PRODUCT FEATURES
1. BASIC IDENTIFICATION ATTRIBUTES
-
Device Type: A portable, battery-operated meter using a polarographic dissolved oxygen sensor. It is a single-parameter instrument for measuring DO concentration and saturation, with integrated temperature measurement and automatic/built-in compensation mechanisms.
-
Designation: DDO10 Portable Polarized Dissolved Oxygen Meter, DLAB DDO10, Portable DO Meter, Single-Parameter DO Analyzer.
-
Key Components:
-
Instrument Meter: Portable housing with a 3.5-inch TFT LCD color screen, UI interface, and Type-C charging port.
-
Polarographic DO Probe: Model DDO01-2M-H dissolved oxygen electrode with a 2-meter cable, pre-installed membrane cap.
-
Electrode Maintenance Supplies: DDOS-01 internal solution and DDOSC replacement membrane cap set.
-
Power Supply: Rechargeable lithium battery (pre-installed) and charging cable.
-
Accessories: Hard carrying case for transport and storage.
-
2. TECHNICAL & PERFORMANCE PROPERTIES
-
Measurement Range: Dissolved oxygen: 0.00~20.00 mg/L; Oxygen saturation: 0.0~200.0%.
-
Measurement Accuracy: DO: ±0.30 mg/L.
-
Temperature Display Range: 0.0~100.0°C / 32.0~212.0°F (with an extended sensor limit).
-
Temperature Accuracy: ±0.2°C.
-
Compensation Methods: Automatic barometric pressure compensation (0~200.0 kPa), automatic temperature compensation (0.0~50.0 °C), and manual salinity compensation (0~45 ppt).
-
Display: 3.5-inch TFT LCD color screen.
-
Data Storage: 3000 data sets, including parameter, measured value, temperature, and timestamp.
-
Power Supply: Rechargeable lithium battery, charged via Type-C port.
-
Protection Class: IP57 (dustproof and waterproof).
-
Dimensions (Carrying Case): 33 × 27.2 × 8.2 cm.
3. PHYSICAL & OPERATIONAL PROPERTIES
-
Display: High-resolution color TFT screen for superior visibility and user experience.
-
User Interface: New UI design and intelligent operation system with functions for timed measurement, parameter setting, and data locking.
-
Connectivity: Type-C charging port, compliant with modern electronics standards.
-
Electrode Maintenance: Polarographic probe requires periodic polarization before use and replenishment of the internal electrolyte solution; different membrane caps are used based on application.
4. SAFETY & COMPLIANCE ATTRIBUTES
-
Regulatory Status: IVD (In Vitro Diagnostic) preparatory equipment; complies with GLP standards for data management.
-
Waterproof Rating: IP57, providing reliable operation in humid or wet field conditions.
-
Power Management: Built-in low-power management, automatic power-off, and power failure protection functions.
-
Software Upgradeable: Supports software upgrades for maintaining instrument performance.
5. STORAGE & HANDLING ATTRIBUTES
-
Storage: Store the meter in a clean, dry place. The DO probe must be stored with the membrane cap moist to prevent it from drying out and damaging the sensor.
-
Cleaning: Rinse the probe with distilled water after each use. Wipe the meter body with a soft, damp cloth using a mild detergent. Do not submerge the meter body.
-
Polarization: The polarographic DO probe requires a warm-up/polarization period (typically 10-30 minutes) before accurate calibration and measurement to stabilize the sensor current. Ensure the meter is ON and connected to the probe well in advance of use.
-
Calibration: Calibrate the meter before use, typically in water-saturated air (100% humidity) or using a zero-oxygen solution (e.g., sodium sulfite).
-
Calibrating: Follow the on-screen instructions to perform electrode calibration or standard solution calibration.
6. LABORATORY & CLINICAL APPLICATIONS
-
Primary Application: On-site or laboratory measurement of dissolved oxygen concentration to assess water quality, monitor biological processes, and support environmental compliance in water treatment, aquaculture, and pharmaceutical facilities.
-
Clinical Role: Used in hospital engineering and facility management teams for water quality surveillance of dialysis water systems, purified water loops, and wastewater treatment plants, as well as in pharmaceutical QA/QC for water system validation.
SAFETY HANDLING PRECAUTIONS
1. SAFETY PRECAUTIONS
-
Electrical Safety: Do not immerse the meter in liquid, despite its IP57 rating. Ensure the Type-C port is dry before charging. Avoid pulling the probe cable violently.
-
Probe Handling: The polarographic probe is delicate. Do not touch the membrane with sharp objects or abrasives. Do not use the probe in solutions containing organic solvents that might damage the membrane.
-
Polarization Time: To ensure accuracy, DO probes require a warm-up period of at least 10-30 minutes after connecting to the meter to stabilize the current. Connect the probe and turn on the meter well in advance of calibration.
-
Calibration Intervals: Calibrate the meter daily before use or as per facility protocol, especially when high accuracy is required for critical water systems. Use air calibration for general purposes.
-
Membrane Cap Life: Replace the membrane cap when it is damaged or when the response time becomes sluggish.
2. FIRST AID MEASURES
-
Electrolyte Exposure: If the internal electrolyte solution (DO filling solution) comes into contact with eyes, flush with copious amounts of water for at least 15 minutes and seek medical attention. If on skin, wash with soap and water.
-
Sample Splash: If a biological sample splashes into the eyes, flush with water for 15 minutes and seek medical attention; if on skin, wash with soap and water.
-
Electrical Malfunction: If the meter shows signs of electrical malfunction, disconnect it from any power source and contact service personnel.
3. FIRE FIGHTING MEASURES
-
Flammability: The plastic housing, cable, and case are combustible; may melt or burn if exposed to flame or high heat.
-
Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires.
-
Fire Response: Disconnect the meter from the charging cable; do not use water on an electrical fire.
Related products
Applicator Sticks
$1.00
Applicator Sticks are single-use medical devices with absorbent tips (cotton, rayon, flocked polyester) on wood, plastic, or paper shafts for collecting clinical specimens (throat, nasal, wound, cervical, urethral, rectal) for microbiological culture, rapid testing, and molecular diagnostics. Sterile individually wrapped or non-sterile bulk formats. Flocked swabs provide >90% specimen release for PCR testing. Primary applications include specimen collection for infection diagnosis, wound care and antiseptic application, gynecological sampling (Pap smears, STI testing), eye/ear specimen collection, laboratory slide preparation, and forensic evidence collection. Critical precautions include single-use only, sterile technique, proper collection method, and biohazard disposal. Essential consumable in all clinical settings.
Blood Grouping kit
$1.00
A Blood Grouping Kit is a Class II medical device (FDA-cleared/CE-marked) containing monoclonal antibodies (Anti-A, Anti-B, Anti-D) and control reagents for determining ABO blood group and Rh factor by agglutination method. The kit includes color-coded reagent vials, reaction cards or slides, mixing sticks, lancets, and capillary pipettes. Test time 2-5 minutes (slide method) or 15-30 minutes (tube method). Interpretation based on agglutination pattern: Anti-A positive = group A; Anti-B positive = group B; both positive = group AB; both negative = group O; Anti-D positive = Rh positive; Anti-D negative = Rh negative. Primary clinical applications include pre-transfusion compatibility testing, prenatal and neonatal testing (Rh incompatibility prevention), preoperative blood typing, blood donor screening, and emergency blood typing. Critical safety precautions include refrigerated storage (2-8°C), proper disposal of lancets in sharps containers, universal precautions for blood samples, and confirmation with reverse typing when possible. Essential kit for transfusion medicine, obstetrics, surgery, and emergency care.
Coagulation Analyzer
$1.00
A Coagulation Analyzer is a compact, automated instrument designed for performing essential tests that evaluate the blood's clotting ability. It accurately measures key parameters such as Prothrombin Time (PT/INR), Activated Partial Thromboplastin Time (aPTT), Thrombin Time, and Fibrinogen, which are critical for monitoring anticoagulant therapy (warfarin, heparin), diagnosing bleeding disorders, and assessing surgical risk. With its photometric detection and user-friendly operation, it delivers reliable results for small to medium-volume laboratories, clinics, and hospital wards. Its role in ensuring safe and effective patient management in thrombosis and hemostasis makes it a vital tool in clinical diagnostics.
Electric Centrifuge
$1.00
An Electric Centrifuge is a Class I medical device that uses rapid rotation to separate fluids of different densities, essential in clinical laboratories for processing blood, urine, and other biological specimens. Available in benchtop, refrigerated, microcentrifuge, hematocrit, and high-speed models with fixed-angle, swinging-bucket, or vertical rotors. Speed range 1,000-30,000+ RPM with RCF up to 65,000+ x g. Features include brushless induction motor, digital controls, imbalance detection, lid lock safety, and programmable protocols. Primary clinical applications include separation of serum/plasma for chemistry and hematology testing, urine sediment analysis for microscopy, platelet-rich plasma (PRP) preparation for regenerative medicine, concentration of bacteria for microbiology, cytology fluid analysis, blood banking, and molecular biology sample processing. Critical safety precautions include proper balancing of loads (weight matching), use of sealed rotors for biohazardous samples, regular rotor inspection for corrosion or cracks, never exceeding maximum rated speed, and never opening lid during operation. Essential equipment in clinical, research, and teaching laboratories.
ESR Tubes Glass
$1.00
ESR Tubes Glass are specialized glass tubes (300 mm length, 2.55 mm bore diameter, graduated 0-200 mm in 1 mm intervals) meeting ICSH and CLSI Westergren specifications for measuring erythrocyte sedimentation rate, a non-specific marker of inflammation. Used with citrated or diluted EDTA blood, filled to exactly 200 mm, placed vertically in Westergren stand, and read at 60 minutes. Primary clinical applications include determination of ESR for diagnosing and monitoring inflammatory conditions (infections, autoimmune disorders, malignancies), monitoring disease activity in rheumatoid arthritis, assessment of temporal arteritis and polymyalgia rheumatica, evaluation of infection and inflammatory response, screening for occult inflammatory conditions, and monitoring chronic inflammatory diseases (SLE, IBD, vasculitis). Critical safety precautions include handling glass tubes carefully to avoid breakage (sharps hazard), proper disposal in sharps containers as biohazardous waste, ensuring vertical alignment and constant temperature (18-25°C), reading at exactly 60 minutes, and avoiding air bubbles and vibration. Essential consumable for reference Westergren ESR testing in clinical laboratories.
Hematology Analyzer
$1.00
A Hematology Analyzer is a compact, automated benchtop analyzer designed to perform Complete Blood Counts (CBC) with a 3-part white blood cell differential. Utilizing impedance and photometric methods, it delivers rapid, precise results for red blood cells, white blood cells, platelets, and key indices from a small blood sample. Ideal for physician offices, small clinics, and satellite laboratories, it enables in-house hematology testing with walk-away operation. Its automated flagging system highlights abnormal results that require further manual smear review. As a core instrument for initial hematological screening, it combines efficiency with essential diagnostic capability for routine patient management.
Mission Plus HB Machine
$1.00
The Mission Plus HB Machine is a portable, battery-operated hemoglobin meter (Class II medical device, FDA-cleared/CE-marked) using photometric technology to measure hemoglobin concentration in capillary or venous blood within 5-15 seconds. Features include backlit LCD display, memory storage for 100-500 results, simple one-button operation, and disposable single-use cuvettes (5-20 µL sample volume). Accuracy ±0.3 g/dL compared to reference methods, measurement range 4-24 g/dL. Primary clinical applications include rapid anemia screening in outpatient clinics, preoperative assessment, antenatal care and maternal health monitoring, malaria-endemic region screening, chronic disease management (CKD, IBD, cancer), nutritional assessment and intervention programs, and blood donor screening. Critical safety precautions include single-use lancets, proper hand hygiene, correct sample application, quality control with control solutions, proper cuvette storage (protect from heat, light, humidity), and never using expired cuvettes. Essential point-of-care device for hemoglobin testing in diverse healthcare settings.
Rota virus
$1.00

Dermatoscope and Magnifiers
Diagnostic Kits
Vital Signs Monitors
Stethoscopes and Accessories
Otoscopes, Ophthalmoscopes, and Retinoscopes
Reflex Hammers and Neurological Tools
Scales and Measuring Devices
Spirometers and Pulmonary Function Tests
Electrosurgical Units and Accessories
Cutting Instruments
Grasping and Holding Instruments
Hemostatic Instruments
Specialized Surgical Sets
Single-Use Procedure Trays and Packs
Surgical Drapes, Gowns, and Covers
Tissue Unifying Instruments
Radiation Protection
X-Ray Machines and Accessories
Ultrasound Systems and Probes
MRI and CT Scanners
Radiology Consumables
Bone Densitometers
Fluoroscopy Equipment
Imaging Tables and Positioning Aids
Microscopes and Accessories
Centrifuges and Separators
Analyzers
Incubators and Ovens
Pipettes, Dispensers, and Lab Glassware
Refrigerators, Freezers, and Storage Units
Lab Consumables
Sterilizers and Autoclaves for Lab Use
Multi-Parameter Monitors
Ventilators and Respiratory Support Devices
Defibrillators and AEDs
Infusion Pumps and IV Systems
Patient Warmers and Cooling Devices
Central Monitoring Stations
Accessories
Anesthesia Machines and Workstations
Oxygen Concentrators and Delivery Systems
Nebulizers and Inhalers
CPAP/BiPAP Machines
Airway Management
Anesthesia Masks, Circuits, and Bags
Humidifiers and Heaters
Respiratory Therapy Accessories
First Aid Kits and Cabinets
Emergency Resuscitation Equipment
Trauma Supplies
Emergency Carts and Crash Carts
Burn Care Products
Bleeding Control
Automated External Defibrillators (AEDs)
Transport and Evacuation
Wheelchairs and Accessories
Walkers, Crutches, and Canes
Prosthetics and Orthotics
Physical Therapy Equipment
Transfer Devices
Bathroom Safety
Orthopedic Traction and Tables
Hot/Cold Therapy Packs and Units
Beds and Mattresses
Chairs and Stools
Tables
Cabinets and Storage
Privacy Screens & Curtains
Stands and Racks
Linens and Textiles
Lighting
Autoclaves and Sterilizers
Ultrasonic Cleaners
Disinfectant Solutions and Wipes
Sterilization Pouches, Wraps, and Indicators
Instrument Trays and Containers
UV and Ozone Disinfection Devices
Washer Disinfectors
Wound Care
Gloves
Masks and Respirators
Catheters and Tubing
Swabs, Applicators, and Sponges
Incontinence Products
Personal Protective Equipment (PPE)
Dental Chairs and Units
Handpieces and Burs
Instruments
Consumables
Sterilization for Dental Use
Orthodontic Supplies
Endodontic Tools
Slit Lamps and Tonometers
Lensometers and Phoropters
Ophthalmic Surgical Instruments
Eyewear Frames and Lenses
Contact Lens Supplies
Vision Testing Charts and Devices
Eye Care Consumables
Laser Systems for Eye Care
ENT Exam Chairs and Tables
Endoscopes
Audiometers and Hearing Tests
ENT Instruments
Nasal and Throat Packs
Hearing Aids and Accessories
Otology Supplies
Fetal Dopplers and Monitors
Delivery Beds and Tables
Gynecological Instruments
Neonatal Incubators and Warmers
Breast Pumps and Accessories
Contraceptive Devices
Maternity Supports and Pads
Neonatal Consumables
Cystoscopes and Urethroscopes
Dialysis Machines and Supplies
Urological Catheters and Bags
Lithotripters
Prostate Treatment Devices
Urinary Incontinence Products
Kidney Stone Management Tools
Consumables & Disposables
EEG and EMG Machines
Neurosurgical Instruments
Nerve Stimulators
Headrests and Positioning Aids
Lumbar Puncture Kits
Seizure Monitoring Devices
Consumables
Rehabilitation for Neurological Conditions
ECG Machines and Accessories
Holter Monitors
Stress Test Systems
Pacemakers and Defibrillator Accessories
Vascular Access Devices
Cardiac Catheters and Guidewires
Blood Flow Meters
Consumables
Orthopedic Instruments
Casts, Splints, and Padding
Joint Replacement Supplies
Prosthetic Limbs and Components
Bone Grafts and Substitutes
Traction Devices
Orthopedic Braces and Supports
Rehabilitation Aids for Orthopedics
Home Oxygen Therapy
Hospital Beds for Home Use
Mobility Aids
Bathroom and Daily Living Aids
Wound Care for Home
Monitoring Devices
Enteral Feeding Pumps and Tubes
Hand Sanitizers and Dispensers
Face Shields and Goggles
Isolation Gowns and Suits
Biohazard Waste Containers
Air Purifiers and HEPA Filters
Surface Disinfectants
Sharps Containers
Protective Barriers
Cardiovascular & Endurance Training
Strength Training & Weightlifting
Functional Training & Core Conditioning
Physical Therapy & Rehabilitation
Sports & Outdoor Recreation
Gym Flooring & Facility Equipment
Fitness Monitoring & Accessories
Kids & Novelties