Showing all 3 results

Horizontal Electrophoresis Tank (DL-SUB01)

The Horizontal Electrophoresis Tank (DL-SUB01) is a compact, high-transparency horizontal gel box designed for rapid DNA and RNA fragment separation, PCR product confirmation, and nucleic acid quality assessment in clinical diagnostic and research laboratories . Featuring interchangeable gel trays (60 × 60 mm and 120 × 60 mm) and multiple comb configurations (1-2 wells for larger sample volumes, 5-10 wells for multiple samples), this system provides resolution of nucleic acid fragments from 5 to 2500 base pairs .
For the molecular biologist and clinical laboratory scientist, the DL-SUB01 supports PCR product confirmation for infectious disease testing (COVID-19, influenza, hepatitis, HIV), restriction fragment analysis for genetic screening (sickle cell disease, cystic fibrosis), nucleic acid quality assessment (DNA/RNA integrity and purity), multiplex PCR product resolution for respiratory virus panels, gel extraction for downstream applications, and microbial pathogen identification workflows .
Constructed from high-strength, high-transparency plastic with platinum wire electrodes, the DL-SUB01 provides a clear view of the electrophoresis process while protecting operators during UV visualization. The lightweight design (0.8 kg) and compact footprint (190 × 110 × 50 mm) make it ideal for space-constrained laboratories, while the interchangeable tray and comb system allows rapid adaptation to varying sample volumes and throughput demands .
For the patient undergoing molecular diagnostic testing for infectious diseases, inherited genetic conditions, or oncology biomarkers, the DL-SUB01's reliable DNA fragment separation ensures accurate PCR product confirmation, restriction fragment analysis, and nucleic acid quality assessment—supporting reliable diagnostic results that guide appropriate treatment decisions across molecular diagnostics, genetic screening, and clinical pathology applications.

Multi-functional Horizontal Electrophoresis Tank (DL-SUB02)

The Multi-functional Horizontal Electrophoresis Tank (DL-SUB02) is a versatile, high-throughput horizontal gel box designed for DNA and RNA fragment separation, PCR product confirmation, restriction fragment analysis, and nucleic acid quality assessment in clinical diagnostic and research laboratories . Featuring interchangeable gel trays (120 × 120 mm, 120 × 60 mm, 60 × 120 mm, 60 × 60 mm) and multiple comb configurations (0.75 mm, 1.0 mm, 1.5 mm thicknesses with 8-well, 11-well, and 2-well options), this system provides resolution of nucleic acid fragments from 5 to 2500 base pairs with a maximum sample load of up to 83 samples per run (using 3 rows of 8-well combs + 2 rows of 11-well combs) .
For the molecular biologist and clinical laboratory scientist, the DL-SUB02 supports high-throughput PCR product confirmation for infectious disease testing (COVID-19, influenza, hepatitis, HIV, respiratory virus panels, gastrointestinal pathogen panels), restriction fragment analysis for genetic screening (sickle cell disease, cystic fibrosis, BRCA mutations), nucleic acid quality assessment for molecular diagnostics, multiplex pathogen detection, gel extraction for downstream applications, and DNA fragment size determination .
Constructed from high-strength, high-transparency plastic with UV protection, the DL-SUB02 provides a clear view of the electrophoresis process while protecting operators during UV visualization. The interchangeable tray and comb system allows rapid adaptation to varying sample volumes and throughput demands, while the 1.0 mm comb thickness is specifically suited for restriction fragment analysis. The system can also be configured as a sequencing tank for specialized applications .
For the patient undergoing molecular diagnostic testing for infectious diseases, inherited genetic conditions, or oncology biomarkers, the DL-SUB02's high-throughput capacity and reliable DNA fragment separation ensure accurate PCR product confirmation, restriction fragment analysis, and nucleic acid quality assessment—supporting reliable diagnostic results that guide appropriate treatment decisions across molecular diagnostics, genetic screening, and clinical pathology applications.

Multi-functional Horizontal Electrophoresis Tank (DL-SUB03)

The Multi-functional Horizontal Electrophoresis Tank (DL-SUB03) is a large-format, high-throughput horizontal gel box designed for DNA and RNA fragment separation, PCR product confirmation, restriction fragment analysis, and nucleic acid quality assessment in high-volume clinical diagnostic and research laboratories . Featuring five interchangeable gel trays (200 × 200 mm, 200 × 130 mm, 130 × 200 mm, 130 × 130 mm, 130 × 65 mm) and multiple comb configurations (0.75 mm, 1.0 mm, 1.5 mm thicknesses with 8-well, 11-well, and 2-well options), this system provides resolution of nucleic acid fragments from 5 to 2500 base pairs with 10 base pair resolution and a maximum sample load of up to 200 samples per run .
For the molecular biologist and clinical laboratory scientist, the DL-SUB03 supports high-volume PCR product confirmation for infectious disease testing (COVID-19, influenza, hepatitis, HIV, respiratory virus panels, gastrointestinal pathogen panels), DNA fragment analysis and size determination with 10 bp resolution, restriction fragment length polymorphism (RFLP) analysis for genetic screening (sickle cell disease, cystic fibrosis, BRCA mutations), multiplex pathogen detection, nucleic acid quality assessment for molecular diagnostics, gel extraction for downstream applications, and sequencing sample preparation .
Constructed from high-strength, high-transparency plastic with UV protection, the DL-SUB03 provides a clear view of the electrophoresis process while protecting operators during UV visualization. The interchangeable tray and comb system allows rapid adaptation to varying sample volumes and throughput demands, with gel inspection window for monitoring progress without opening the cover . A free gel tray is included with the system .
For the patient undergoing molecular diagnostic testing for infectious diseases, inherited genetic conditions, or oncology biomarkers, the DL-SUB03's high-volume capacity (up to 200 samples per run), high-resolution fragment separation (10 bp resolution), and reliable DNA fragment analysis ensure accurate PCR product confirmation, restriction fragment analysis, and nucleic acid quality assessment—supporting reliable diagnostic results that guide appropriate treatment decisions across molecular diagnostics, genetic screening, and clinical pathology applications.