Multi-functional Horizontal Electrophoresis Tank (DL-SUB02)

WhatsApp Order
The Multi-functional Horizontal Electrophoresis Tank (DL-SUB02) is a versatile, high-throughput horizontal gel box designed for DNA and RNA fragment separation, PCR product confirmation, restriction fragment analysis, and nucleic acid quality assessment in clinical diagnostic and research laboratories . Featuring interchangeable gel trays (120 × 120 mm, 120 × 60 mm, 60 × 120 mm, 60 × 60 mm) and multiple comb configurations (0.75 mm, 1.0 mm, 1.5 mm thicknesses with 8-well, 11-well, and 2-well options), this system provides resolution of nucleic acid fragments from 5 to 2500 base pairs with a maximum sample load of up to 83 samples per run (using 3 rows of 8-well combs + 2 rows of 11-well combs) .
For the molecular biologist and clinical laboratory scientist, the DL-SUB02 supports high-throughput PCR product confirmation for infectious disease testing (COVID-19, influenza, hepatitis, HIV, respiratory virus panels, gastrointestinal pathogen panels), restriction fragment analysis for genetic screening (sickle cell disease, cystic fibrosis, BRCA mutations), nucleic acid quality assessment for molecular diagnostics, multiplex pathogen detection, gel extraction for downstream applications, and DNA fragment size determination .
Constructed from high-strength, high-transparency plastic with UV protection, the DL-SUB02 provides a clear view of the electrophoresis process while protecting operators during UV visualization. The interchangeable tray and comb system allows rapid adaptation to varying sample volumes and throughput demands, while the 1.0 mm comb thickness is specifically suited for restriction fragment analysis. The system can also be configured as a sequencing tank for specialized applications .
For the patient undergoing molecular diagnostic testing for infectious diseases, inherited genetic conditions, or oncology biomarkers, the DL-SUB02’s high-throughput capacity and reliable DNA fragment separation ensure accurate PCR product confirmation, restriction fragment analysis, and nucleic acid quality assessment—supporting reliable diagnostic results that guide appropriate treatment decisions across molecular diagnostics, genetic screening, and clinical pathology applications.
Description

Multi-functional Horizontal Electrophoresis Tank (DL-SUB02)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. High-Throughput PCR Product Confirmation for Infectious Disease Testing
  • Primary Use: Provides a versatile horizontal electrophoresis tank with interchangeable gel trays (120 × 120 mm, 120 × 60 mm, 60 × 120 mm, 60 × 60 mm) and multiple comb configurations, enabling high-throughput separation of PCR products for infectious disease diagnosis .
  • How it helps: For the molecular biologist and clinical laboratory scientist, the DL-SUB02 delivers flexible sample loading capacity from 5 to 2500 base pairs—allowing confirmation of up to 83 samples per run (using 3 rows of 8-well combs + 2 rows of 11-well combs). For the patient undergoing molecular diagnostic testing for COVID-19, influenza, hepatitis, HIV, or other infectious diseases, efficient high-throughput processing reduces turnaround time for test results, enabling earlier diagnosis and treatment initiation.
2. Restriction Fragment Analysis for Genetic Screening
  • Primary Use: Supports restriction fragment length polymorphism (RFLP) analysis, genetic fingerprinting, and mutation detection using standard 1.0 mm thickness combs .
  • How it helps: For the molecular geneticist and clinical laboratory scientist, the DL-SUB02’s 1.0 mm comb thickness provides optimal sample volume for restriction fragment analysis—enabling detection of genetic mutations associated with inherited disorders (e.g., sickle cell disease, cystic fibrosis, BRCA mutations). For the patient undergoing genetic screening, accurate fragment separation supports definitive diagnosis and informs clinical management decisions.
3. Nucleic Acid Quality Assessment for Molecular Diagnostics
  • Primary Use: Used for rapid assessment of DNA and RNA integrity, purity, and concentration before downstream molecular applications such as PCR, sequencing, and hybridization assays .
  • How it helps: For the clinical laboratory scientist, the DL-SUB02 provides visual confirmation of nucleic acid quality—enabling detection of degradation, contamination, or concentration issues that could compromise diagnostic test results. For the patient, proper sample quality assessment ensures that only high-quality specimens proceed to diagnostic testing, reducing the risk of false-negative or false-positive results.
4. Multiplex Pathogen Detection and Resolution
  • Primary Use: Supports multiplex PCR product resolution using long gels (120 × 120 mm configuration) with sample loads up to 1500 bp, enabling simultaneous detection of multiple pathogen targets in a single lane .
  • How it helps: For the clinical microbiologist, the DL-SUB02’s long gel configuration provides extended separation distance for resolving multiple PCR amplicons of different sizes—enabling multiplex detection of respiratory virus panels, gastrointestinal pathogen panels, and sexually transmitted infection panels . For the patient, simultaneous testing for multiple pathogens reduces the number of specimens required and accelerates diagnosis of co-infections.

SECONDARY & SUPPORTIVE USES

1. RNA Denaturing Gel Electrophoresis: Used for formaldehyde-agarose gel electrophoresis for assessing RNA integrity and purity (28S/18S ratio) in molecular diagnostics .
2. Gel Extraction and Purification: Used for separation and visualization of target DNA fragments before gel extraction for downstream applications (e.g., sequencing, cloning).
3. Southern Blotting Sample Preparation: Provides DNA separation for subsequent transfer to membranes for hybridization-based detection.
4. Microbial Pathogen Identification: Used for PCR product confirmation in bacterial, viral, and fungal identification workflows in clinical microbiology .
5. DNA Fragment Size Determination: Supports molecular weight determination of DNA fragments using DNA ladders and size markers.
6. Blood Bank and Transfusion Medicine: Supports DNA-based blood group genotyping and donor screening for blood-borne pathogens.
7. Food Safety and Quality Testing: Supports GMO detection, foodborne pathogen identification, and food authenticity testing.
8. PFGE Sample Confirmation: Used for checking DNA quality and size range before pulsed-field gel electrophoresis for bacterial typing in outbreak investigations.
9. Veterinary Diagnostic Laboratory: Used for PCR product confirmation and nucleic acid analysis for animal health testing .
10. Environmental Microbiology Testing: Used for detection of microbial pathogens in water, soil, and environmental samples by PCR and electrophoresis .
11. Pharmaceutical Quality Control: Used for nucleic acid purity assessment in biopharmaceutical manufacturing .
12. Pharmacogenomics Testing: Supports DNA fragment analysis for genotyping of drug metabolism genes (e.g., CYP450) .
13. Research and Academic Laboratories: Provides flexible electrophoresis for DNA fragment analysis in molecular biology research .
14. Educational and Training Laboratories: Supports teaching of PCR and electrophoresis techniques in medical and graduate training programs .
15. Method Development and Optimization: Used to optimize electrophoresis protocols for clinical implementation .
16. Troubleshooting and Quality Assurance: Supports investigation of PCR failures, contamination events, and assay performance issues .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A multi-functional horizontal electrophoresis tank with interchangeable gel trays and multiple comb configurations, designed for high-throughput DNA/RNA fragment separation, PCR product confirmation, and nucleic acid quality assessment in clinical diagnostic and research laboratories .
  • Designation: DL-SUB02 Multi-functional Horizontal Electrophoresis Tank, Multi-functional Horizontal Gel Tank, High-Throughput DNA Electrophoresis Tank, DLAB DL-SUB02, Multi-Purpose Horizontal Gel Box .
  • Key Components:
    • Tank Body: High-strength, high-transparency plastic with UV protection .
    • Gel Trays: Four interchangeable trays (120 × 120 mm, 120 × 60 mm, 60 × 120 mm, 60 × 60 mm) .
    • Sample Combs: Multiple comb thicknesses (0.75 mm, 1.0 mm, 1.5 mm) with various well configurations (8-well, 11-well, 2-well) .
    • Compatibility: Can be used as a sequencing tank .
    • Electrodes: Platinum wire electrodes .
    • Buffer Chamber: Integrated buffer tank with volume indicators .
    • Cover: Transparent safety cover with UV protection .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Resolution: 5-2500 bp (base pair) separation range; up to 1500 bp with long gel configuration .
  • Maximum Sample Load: Up to 83 samples per run (using 3 rows of 8-well combs + 2 rows of 11-well combs) .
  • Sample Output: Suitable for clinical diagnostic sample volumes .
  • Running Time: Optimized for rapid separation .
  • Gel Tray Options: Four interchangeable trays: 120 × 120 mm, 120 × 60 mm, 60 × 120 mm, 60 × 60 mm .
  • Comb Thickness: 0.75 mm, 1.0 mm, 1.5 mm .
  • Comb Configurations: 8-well combs, 11-well combs, 2-well combs .
  • Construction Material: High-strength, high-transparency plastic with UV protection .
  • Electrode Material: Platinum wire .
  • Durability: Heat-resistant plate for gel preparation .
  • Safety Features: Transparent cover for UV protection; insulated design .
  • Functionality: Can be used as a sequencing tank .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: High-strength, high-transparency plastic with injection molding for durability and visibility; UV protection for operator safety .
  • Interchangeable Trays: Four gel tray sizes for flexible throughput and resolution needs .
  • Comb Options: Multiple comb thicknesses for different sample volume requirements .
  • Gel Casting: Heat-resistant plate for gel preparation; easy-to-use comb guides .
  • Buffer Management: Clear buffer level indicators; easy pour and disposal .
  • Electrode Access: Easy access for cleaning and maintenance .
  • UV Protection: Transparent cover provides UV protection during gel observation .
  • Portability: Moderate weight for benchtop use .
  • Compatibility: Standard DNA ladders and size markers; sequencing applications .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: Medical laboratory equipment for in vitro diagnostic use .
  • Safety Features: Transparent cover with UV protection; insulated design .
  • Electrical Safety: Low voltage operation with electrophoresis power supply .
  • Material Safety: Non-toxic plastic materials; platinum electrodes .
  • UV Safety: Cover provides UV protection; use appropriate UV protective equipment when visualizing gels .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry benchtop; avoid stacking heavy objects .
  • Cleaning: Rinse thoroughly with distilled water after each use; remove residual agarose .
  • Electrode Care: Avoid bending or damaging electrodes; clean with distilled water .
  • Gel Tray Care: Clean trays and combs with mild detergent; rinse thoroughly; heat-resistant plates for gel preparation .
  • Buffer Disposal: Dispose of used electrophoresis buffer per laboratory safety protocols .
  • Visualization: Use appropriate UV transilluminator for visualizing DNA bands after staining .
  • Sequencing Applications: Use appropriate gel concentrations and running conditions for sequencing protocols .

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: High-throughput PCR product confirmation for infectious disease testing, restriction fragment analysis for genetic screening, nucleic acid quality assessment, multiplex pathogen detection, and gel extraction in clinical diagnostic and research laboratories .
  • Clinical Role: Essential multi-functional electrophoresis equipment in clinical diagnostic laboratories, molecular diagnostics labs, hospital pathology departments, blood banks, reference laboratories, and research facilities performing high-throughput DNA/RNA electrophoresis for patient diagnosis .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Power Supply Connection: Connect to an approved electrophoresis power supply only; observe correct polarity .
  • Buffer Levels: Ensure gel is fully submerged in buffer during electrophoresis .
  • Comb Selection: Select appropriate comb thickness (0.75 mm, 1.0 mm, 1.5 mm) for sample volume and application .
  • Gel Tray Selection: Select appropriate gel tray size for throughput and resolution needs .
  • Transilluminator Use: Use appropriate UV protective equipment (gloves, face shield) when visualizing gels on UV transilluminator .
  • Staining Hazards: Use appropriate PPE when handling DNA stains (e.g., ethidium bromide alternatives) .
  • Cleaning: Disconnect from power supply before cleaning .
  • Buffer Disposal: Dispose of used buffer per laboratory safety protocols; some buffers contain hazardous chemicals .
  • Agarose Preparation: Use appropriate PPE when handling hot agarose solution .
  • Training: Only trained laboratory personnel should operate the DL-SUB02 for clinical diagnostic applications .

2. FIRST AID MEASURES

  • Buffer Spill: If electrophoresis buffer spills, clean immediately; use absorbent materials; dispose per laboratory protocol .
  • Electrical Shock: If electrical shock occurs, disconnect power supply immediately; seek medical attention for any electrical injury .
  • Hot Agarose Burn: If hot agarose contacts skin, cool affected area with cool running water; seek medical attention for severe burns .
  • UV Exposure: If eyes or skin are exposed to UV light during visualization, protect area; seek medical evaluation if symptoms develop .

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic tank components may burn if exposed to flame or high heat .
  • Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for electrical fires .
  • Fire Response: Disconnect power supply; do not use water on electrical fire .