Multi-functional Horizontal Electrophoresis Tank (DL-SUB03)

WhatsApp Order
The Multi-functional Horizontal Electrophoresis Tank (DL-SUB03) is a large-format, high-throughput horizontal gel box designed for DNA and RNA fragment separation, PCR product confirmation, restriction fragment analysis, and nucleic acid quality assessment in high-volume clinical diagnostic and research laboratories . Featuring five interchangeable gel trays (200 × 200 mm, 200 × 130 mm, 130 × 200 mm, 130 × 130 mm, 130 × 65 mm) and multiple comb configurations (0.75 mm, 1.0 mm, 1.5 mm thicknesses with 8-well, 11-well, and 2-well options), this system provides resolution of nucleic acid fragments from 5 to 2500 base pairs with 10 base pair resolution and a maximum sample load of up to 200 samples per run .
For the molecular biologist and clinical laboratory scientist, the DL-SUB03 supports high-volume PCR product confirmation for infectious disease testing (COVID-19, influenza, hepatitis, HIV, respiratory virus panels, gastrointestinal pathogen panels), DNA fragment analysis and size determination with 10 bp resolution, restriction fragment length polymorphism (RFLP) analysis for genetic screening (sickle cell disease, cystic fibrosis, BRCA mutations), multiplex pathogen detection, nucleic acid quality assessment for molecular diagnostics, gel extraction for downstream applications, and sequencing sample preparation .
Constructed from high-strength, high-transparency plastic with UV protection, the DL-SUB03 provides a clear view of the electrophoresis process while protecting operators during UV visualization. The interchangeable tray and comb system allows rapid adaptation to varying sample volumes and throughput demands, with gel inspection window for monitoring progress without opening the cover . A free gel tray is included with the system .
For the patient undergoing molecular diagnostic testing for infectious diseases, inherited genetic conditions, or oncology biomarkers, the DL-SUB03’s high-volume capacity (up to 200 samples per run), high-resolution fragment separation (10 bp resolution), and reliable DNA fragment analysis ensure accurate PCR product confirmation, restriction fragment analysis, and nucleic acid quality assessment—supporting reliable diagnostic results that guide appropriate treatment decisions across molecular diagnostics, genetic screening, and clinical pathology applications.
Description

Multi-functional Horizontal Electrophoresis Tank (DL-SUB03)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. High-Throughput PCR Product Confirmation for Infectious Disease Testing
  • Primary Use: Provides a large-format multi-functional horizontal electrophoresis tank with interchangeable gel trays (200 × 200 mm, 200 × 130 mm, 130 × 200 mm, 130 × 130 mm, 130 × 65 mm) and multiple comb configurations, enabling high-volume separation of PCR products for infectious disease diagnosis .
  • How it helps: For the molecular biologist and clinical laboratory scientist, the DL-SUB03 delivers exceptional sample loading capacity using long gel configurations—allowing confirmation of up to 200 samples per run. For the patient undergoing molecular diagnostic testing for COVID-19, influenza, hepatitis, HIV, or other infectious diseases, high-volume processing reduces turnaround time for test results, enabling earlier diagnosis and treatment initiation.
2. DNA Fragment Analysis and Size Determination
  • Primary Use: Supports separation of DNA fragments from 5 to 2500 base pairs with resolution of fragments differing by 10 base pairs, enabling precise molecular weight determination and fragment sizing .
  • How it helps: For the molecular geneticist and clinical laboratory scientist, the DL-SUB03’s long gel configuration (200 × 200 mm) provides extended separation distance for high-resolution fragment analysis—enabling accurate sizing of PCR products, restriction fragments, and sequencing samples . For the patient undergoing genetic testing for inherited disorders, precise fragment sizing supports definitive diagnosis and informs clinical management decisions.
3. Restriction Fragment Length Polymorphism (RFLP) Analysis
  • Primary Use: Supports large-format restriction fragment analysis for genetic fingerprinting, mutation detection, and population genetics using 1.0 mm and 1.5 mm thickness combs .
  • How it helps: For the molecular geneticist, the DL-SUB03’s large gel format provides superior separation of complex restriction fragment patterns—enabling detection of genetic mutations associated with inherited disorders, cancer predisposition, and pharmacogenetic variation . For the patient undergoing genetic screening, high-resolution RFLP analysis supports accurate diagnosis and personalized treatment planning.
4. Multiplex PCR Pathogen Detection and Resolution
  • Primary Use: Supports multiplex PCR product resolution using long gels (200 × 200 mm configuration) with sample loads up to 200 samples per run, enabling simultaneous detection of multiple pathogen targets in high-volume testing .
  • How it helps: For the clinical microbiologist, the DL-SUB03’s long gel configuration provides extended separation distance for resolving multiple PCR amplicons of different sizes—enabling multiplex detection of respiratory virus panels, gastrointestinal pathogen panels, and sexually transmitted infection panels in high-volume clinical laboratories. For the patient, simultaneous testing for multiple pathogens reduces the number of specimens required and accelerates diagnosis of co-infections.

SECONDARY & SUPPORTIVE USES

1. RNA Denaturing Gel Electrophoresis: Used for formaldehyde-agarose gel electrophoresis for assessing RNA integrity and purity (28S/18S ratio) in molecular diagnostics .
2. Gel Extraction and Purification: Used for separation and visualization of target DNA fragments before gel extraction for downstream applications (e.g., sequencing, cloning).
3. Southern Blotting Sample Preparation: Provides DNA separation for subsequent transfer to membranes for hybridization-based detection.
4. Microbial Pathogen Identification: Used for PCR product confirmation in bacterial, viral, and fungal identification workflows in clinical microbiology .
5. DNA Fragment Size Determination: Supports molecular weight determination of DNA fragments using DNA ladders and size markers with 10 bp resolution .
6. AFLP Analysis (Amplified Fragment Length Polymorphism): Supports large-format fragment separation for genetic fingerprinting and marker-assisted selection.
7. Blood Bank and Transfusion Medicine: Supports DNA-based blood group genotyping and donor screening for blood-borne pathogens.
8. Food Safety and Quality Testing: Supports GMO detection, foodborne pathogen identification, and food authenticity testing.
9. PFGE Sample Confirmation: Used for checking DNA quality and size range before pulsed-field gel electrophoresis for bacterial typing in outbreak investigations.
10. Veterinary Diagnostic Laboratory: Used for PCR product confirmation and nucleic acid analysis for animal health testing .
11. Environmental Microbiology Testing: Used for detection of microbial pathogens in water, soil, and environmental samples by PCR and electrophoresis .
12. Pharmaceutical Quality Control: Used for nucleic acid purity assessment in biopharmaceutical manufacturing .
13. Pharmacogenomics Testing: Supports DNA fragment analysis for genotyping of drug metabolism genes (e.g., CYP450) .
14. Research and Academic Laboratories: Provides large-format electrophoresis for DNA fragment analysis in molecular biology research .
15. Educational and Training Laboratories: Supports teaching of PCR and electrophoresis techniques in medical and graduate training programs .
16. Method Development and Optimization: Used to optimize electrophoresis protocols for clinical implementation .
17. Troubleshooting and Quality Assurance: Supports investigation of PCR failures, contamination events, and assay performance issues .
18. Sequencing Sample Preparation: Used for checking sequencing reaction products before purification .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A large-format, multi-functional horizontal electrophoresis tank with interchangeable gel trays and multiple comb configurations, designed for high-volume DNA/RNA fragment separation, PCR product confirmation, nucleic acid quality assessment, and high-resolution genetic analysis in clinical diagnostic and research laboratories .
  • Designation: DL-SUB03 Multi-functional Horizontal Electrophoresis Tank, Large-Format Horizontal Gel Tank, High-Throughput DNA Electrophoresis Tank, DLAB DL-SUB03, Multi-Purpose Large Horizontal Gel Box .
  • Key Components:
    • Tank Body: High-strength, high-transparency plastic with UV protection .
    • Gel Trays: Five interchangeable trays (200 × 200 mm, 200 × 130 mm, 130 × 200 mm, 130 × 130 mm, 130 × 65 mm) .
    • Sample Combs: Multiple comb thicknesses (0.75 mm, 1.0 mm, 1.5 mm) with 8-well, 11-well, and 2-well configurations .
    • Maximum Sample Load: Up to 200 samples per run (using long tray with 2 rows of 11-well combs + 2 rows of 8-well combs) .
    • Application: Can be used as a sequencing tank .
    • Electrodes: Platinum wire electrodes .
    • Buffer Chamber: Integrated buffer tank with volume indicators .
    • Cover: Transparent safety cover with UV protection .
    • Inspection Window: Gel inspection window for monitoring .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Resolution: 5-2500 bp (base pair) separation range; resolves fragments differing by 10 bp .
  • Maximum Sample Load: Up to 200 samples per run .
  • Sample Output: Suitable for high-volume clinical diagnostic laboratories .
  • Running Time: Optimized for high-volume processing with rapid separation .
  • Gel Tray Options: Five interchangeable trays for flexible throughput and resolution: 200 × 200 mm, 200 × 130 mm, 130 × 200 mm, 130 × 130 mm, 130 × 65 mm .
  • Comb Thickness: 0.75 mm, 1.0 mm, 1.5 mm .
  • Comb Configurations: 8-well combs, 11-well combs, 2-well combs .
  • Construction Material: High-strength, high-transparency plastic with UV protection .
  • Electrode Material: Platinum wire .
  • Durability: Heat-resistant plate for gel preparation .
  • Safety Features: Transparent cover with UV protection; insulated design; gel inspection window .
  • Functionality: Can be used as a sequencing tank .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: High-strength, high-transparency plastic with injection molding for durability and visibility; UV protection for operator safety .
  • Interchangeable Trays: Five gel tray sizes for flexible throughput and resolution needs .
  • Comb Options: Multiple comb thicknesses (0.75 mm, 1.0 mm, 1.5 mm) for different sample volume requirements .
  • Gel Casting: Heat-resistant plate for gel preparation; easy-to-use comb guides .
  • Buffer Management: Clear buffer level indicators; easy pour and disposal .
  • Electrode Access: Easy access for cleaning and maintenance .
  • UV Protection: Transparent cover provides UV protection during gel observation; separate gel inspection window for monitoring .
  • Portability: Benchtop design with large footprint for high-volume processing .
  • Compatibility: Standard DNA ladders and size markers; sequencing applications .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: Medical laboratory equipment for in vitro diagnostic use .
  • Safety Features: Transparent cover with UV protection; insulated design; gel inspection window .
  • Electrical Safety: Low voltage operation with electrophoresis power supply .
  • Material Safety: Non-toxic plastic materials; platinum electrodes .
  • UV Safety: Cover provides UV protection; use appropriate UV protective equipment when visualizing gels .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry benchtop; avoid stacking heavy objects .
  • Cleaning: Rinse thoroughly with distilled water after each use; remove residual agarose .
  • Electrode Care: Avoid bending or damaging electrodes; clean with distilled water .
  • Gel Tray Care: Clean trays and combs with mild detergent; rinse thoroughly; heat-resistant plates for gel preparation .
  • Buffer Disposal: Dispose of used electrophoresis buffer per laboratory safety protocols .
  • Visualization: Use appropriate UV transilluminator for visualizing DNA bands after staining .
  • Sequencing Applications: Use appropriate gel concentrations and running conditions for sequencing protocols .
  • Gel Inspection: Use gel inspection window to monitor electrophoresis progress without opening cover .

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: High-volume PCR product confirmation for infectious disease testing, DNA fragment analysis and size determination, restriction fragment length polymorphism (RFLP) analysis, multiplex pathogen detection, nucleic acid quality assessment, and gel extraction in clinical diagnostic and research laboratories .
  • Clinical Role: Essential large-format, multi-functional electrophoresis equipment in clinical diagnostic laboratories, molecular diagnostics labs, hospital pathology departments, blood banks, reference laboratories, and research facilities performing high-volume DNA/RNA electrophoresis for patient diagnosis .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Power Supply Connection: Connect to an approved electrophoresis power supply only; observe correct polarity .
  • Buffer Levels: Ensure gel is fully submerged in buffer during electrophoresis .
  • Comb Selection: Select appropriate comb thickness (0.75 mm, 1.0 mm, 1.5 mm) for sample volume and application .
  • Gel Tray Selection: Select appropriate gel tray size for throughput and resolution needs .
  • Transilluminator Use: Use appropriate UV protective equipment (gloves, face shield) when visualizing gels on UV transilluminator .
  • Staining Hazards: Use appropriate PPE when handling DNA stains (e.g., ethidium bromide alternatives) .
  • Cleaning: Disconnect from power supply before cleaning .
  • Buffer Disposal: Dispose of used buffer per laboratory safety protocols; some buffers contain hazardous chemicals .
  • Agarose Preparation: Use appropriate PPE when handling hot agarose solution .
  • Training: Only trained laboratory personnel should operate the DL-SUB03 for clinical diagnostic applications .

2. FIRST AID MEASURES

  • Buffer Spill: If electrophoresis buffer spills, clean immediately; use absorbent materials; dispose per laboratory protocol .
  • Electrical Shock: If electrical shock occurs, disconnect power supply immediately; seek medical attention for any electrical injury .
  • Hot Agarose Burn: If hot agarose contacts skin, cool affected area with cool running water; seek medical attention for severe burns .
  • UV Exposure: If eyes or skin are exposed to UV light during visualization, protect area; seek medical evaluation if symptoms develop .

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic tank components may burn if exposed to flame or high heat .
  • Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for electrical fires .
  • Fire Response: Disconnect power supply; do not use water on electrical fire .