High Speed Palm Micro Centrifuge(D1012UA )

WhatsApp Order
The High Speed Palm Micro Centrifuge(D1012UA ) is a compact, high-speed centrifuge designed for rapid sample processing in clinical and research laboratories. Operating at speeds up to 10,000 rpm (up to 7,490 × g) with a quiet DC brushless motor, this palm-sized centrifuge supports multiple rotor configurations—including 12 x 0.5/1.5/2.0 mL microcentrifuge tubes, 44 x 0.2 mL PCR tubes, and 4 x 0.2 mL PCR 8-strips . The OLED display allows precise monitoring and adjustment of speed (2,000-10,000 rpm) and run time (10 seconds to 20 minutes) . The FA12-2P combo rotor features a durable clamp-locking design for safe, secure operation .
For the clinical laboratory scientist and medical technologist, the D1012UA facilitates rapid spin-down of samples for PCR preparation , microfiltration of body fluids for urinalysis and cytology, cell pelleting for cytological examination , and nucleic acid extraction and purification workflows . The screen buttons allow adjustment of motor start/stop with support for both soft braking and instant stop modes .
Its compact footprint (210 x 180 x 130 mm) and lightweight design (1.5 kg) make it ideal for point-of-care testing, physician office laboratories, and space-constrained benchtops . Wide voltage technology (100-240V) ensures consistent performance across different laboratory power conditions . This centrifuge provides reliable, consistent performance for routine laboratory workflows supporting patient diagnosis and treatment monitoring.
Description

High Speed Palm Micro Centrifuge(D1012UA )

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Rapid Sample Spin-Down for Molecular Biology Workflows
  • Primary Use: Provides a compact, high-speed microcentrifuge that spins up to 10,000 rpm (7,490 × g) to rapidly collect liquid from tube walls or caps, ensuring complete reagent mixing and optimal reaction conditions for PCR and other molecular assays .
  • How it helps: For the molecular biologist and clinical laboratory scientist, the D1012UA enables quick spin-down of samples before and after thermal cycling—preventing volume loss, ensuring accurate reagent concentrations, and reducing variability in diagnostic test results. For the patient, reliable PCR preparation contributes to accurate molecular diagnostic results for infectious diseases such as COVID-19, influenza, hepatitis, and other pathogens .
2. PCR Sample Preparation and Molecular Diagnostics
  • Primary Use: Accommodates 0.2 mL PCR tubes, 44 × 0.2 mL PCR single tubes, and 4 × 0.2 mL PCR 8-strip tubes, enabling rapid preparation of samples before polymerase chain reaction amplification .
  • How it helps: For the molecular biologist and clinical laboratory scientist, the D1012UA centrifuge includes dedicated rotor configurations for PCR tubes and strip tubes—ensuring that samples are properly mixed, free from air bubbles, and collected at the bottom of tubes before thermal cycling . For the patient undergoing molecular testing, reliable PCR sample preparation contributes to accurate diagnostic results that guide treatment decisions.
3. Microfiltration and Sample Clarification for Body Fluids
  • Primary Use: Facilitates rapid spin-down and microfiltration of urine, cerebrospinal fluid, and other body fluid samples to remove cellular debris and particulates before microscopic examination or chemical analysis .
  • How it helps: For the clinical laboratory scientist, the centrifuge’s OLED display and soft braking modes streamline the preparation of body fluid samples—improving workflow efficiency and ensuring consistent sample quality for diagnostic testing . For the patient, proper sample clarification leads to more accurate test results, reducing the need for repeat specimen collection and allowing for confident clinical decision-making.
4. Cell Separation and Pellet Formation
  • Primary Use: Generates sufficient centrifugal force (up to 7,490 × g) to pellet cells from liquid samples, supporting cytological examination, cell-based diagnostic testing, and sedimentation of small biological components .
  • How it helps: For the cytotechnologist and pathologist, the compact centrifuge allows for rapid cell concentration from body fluids such as pleural fluid, ascitic fluid, and cerebrospinal fluid—enhancing the diagnostic yield of cytological examination for cancer detection. For the patient, improved cell recovery increases the sensitivity of diagnosis from fluid specimens.

SECONDARY & SUPPORTIVE USES

1. Microcentrifuge Tube Processing: Supports 0.5mL, 1.5mL, and 2.0mL microcentrifuge tubes for standard laboratory applications using the FA12-2P rotor .
2. Nucleic Acid Extraction and Purification: Used in DNA and RNA extraction protocols for spin column-based purification and sample preparation in molecular biology workflows .
3. Plasmid Mini-Prep Preparation: Supports quick spin-downs during mini-prep plasmid isolation procedures for cloning and sequencing experiments.
4. Protein Precipitation and Biochemical Assays: Used for protein precipitation steps in biochemical assays and sample preparation for downstream analysis.
5. Phase Separation for Extraction Procedures: Facilitates separation of organic and aqueous phases in liquid-liquid extraction procedures.
6. Lipid and Lipoprotein Analysis: Supports sample preparation for lipid panel testing in clinical chemistry laboratories.
7. Coagulation Testing Preparation: Used for platelet-poor plasma preparation for coagulation studies.
8. Therapeutic Drug Monitoring: Supports sample preparation for therapeutic drug monitoring and toxicology screening.
9. Research and Academic Laboratories: Used in university and research laboratory settings for routine centrifugation needs.
10. Veterinary Diagnostic Laboratory: Supports sample processing for animal health testing and veterinary diagnostics.
11. Food Safety and Environmental Testing: Used in food microbiology and environmental testing laboratories for sample preparation.
12. Biochemistry and Laboratory Research: Used in biochemical assays and microsample processing where rapid centrifugation of small tubes is required .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A compact, high-speed palm microcentrifuge with OLED display, designed for rapid sample processing, PCR preparation, microfiltration, and cell separation in clinical and research laboratories .
  • Designation: D1012UA High Speed Palm Micro Centrifuge, High Speed Micro Centrifuge, Palm Centrifuge, Benchtop Microcentrifuge, PCR Centrifuge, Laboratory Centrifuge, DLAB D1012UA .
  • Key Components:
o Motor: DC brushless motor for smooth, quiet operation .
o Rotor: FA12-2P combo rotor with clamp lock design for safety and durability .
o Rotor Capacity: 0.5/1.5/2.0 mL × 12 tubes; 0.2 mL × 44 PCR tubes; 0.2 mL × 4 PCR 8-strips .
o Display: OLED display for speed and time settings .
o Control: Screen buttons for motor start/stop with soft braking and instant stop modes .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Maximum Speed: 10,000 rpm .
  • Maximum RCF (Relative Centrifugal Force): 7,490 × g (1.5/2 mL tubes); 6,596–7,490 × g (PCR 8-strips) .
  • Speed Setting Range: 2,000 – 10,000 rpm, step: 1,000 rpm .
  • Time Setting Range: 10 seconds – 20 minutes, step: 10 seconds .
  • Acceleration/Deceleration: 1 acceleration step / 2 deceleration steps (soft braking and instant stop) .
  • Motor Type: DC brushless motor .
  • Noise Level: ≤ 58 dB .
  • Power Requirements: AC 100–240 V, 50/60 Hz, 30–40 W .
  • Dimensions (L × W × H): 210 × 180 × 130 mm .
  • Weight: 1.5 kg .
  • Voltage Technology: Wide voltage technology ensures speed is not affected by voltage fluctuations .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: High-strength plastic housing with durable rotor assembly.
  • Control: OLED display with screen buttons for speed and time adjustment .
  • Rotor Design: Clamp-locking rotor for safety, durability, and ease of use .
  • Braking Modes: Supports soft braking and instant stop modes .
  • Operation Modes: Continuous operation mode; supports setting memory function.
  • Portability: Compact footprint for benchtop or palm use; lightweight at only 1.5 kg.
  • Maintenance: DC brushless motor requires minimal maintenance .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: Class II medical device (instrument classification) .
  • Registration: Meets applicable regulatory registration requirements.
  • Rotor Safety: Durable clamp-locking rotor design ensures secure operation during high-speed centrifugation .
  • Electrical Safety: Wide voltage compatibility (100-240V) with voltage fluctuation resistance .
  • Lid Safety: Secure lid interlock system prevents operation with open lid.
  • Noise Control: Low noise operation (≤58 dB) for comfortable laboratory environment .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry benchtop; protect from dust and moisture.
  • Cleaning: Wipe exterior with soft, damp cloth; use mild detergent if needed.
  • Rotor Maintenance: Remove and clean rotors with mild detergent; dry thoroughly before reinstallation.
  • Inspection: Inspect rotors for cracks or damage before each use; replace if compromised.
  • Power Cord: Inspect power cord for damage before each use.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Rapid sample spin-down, PCR preparation, microfiltration of body fluids, and cell pelleting for diagnostic testing in clinical laboratories, molecular biology labs, and research settings .
  • Clinical Role: Essential sample preparation equipment in clinical diagnostic laboratories, hospital laboratories, physician office laboratories, molecular diagnostics labs, and research laboratories.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Imbalance Detection: Ensure rotor is balanced with samples of equal weight; imbalance may cause excessive vibration.
  • Lid Security: Ensure lid is securely closed before operation; centrifuge will not operate with open lid.
  • Rotor Inspection: Inspect rotors for cracks or damage before each use; do not use damaged rotors.
  • Tube Compatibility: Use only tubes rated for centrifugation at high speeds.
  • Liquid Levels: Do not overfill tubes; leave adequate headspace to prevent leakage.
  • Cleaning: Clean spills immediately; disinfect if biological materials are involved.
  • Placement: Place on stable, level surface; ensure adequate ventilation.
  • Power Supply: Use only specified power supply (100-240VAC) .
  • Training: Only trained laboratory personnel should operate the centrifuge.

2. FIRST AID MEASURES

  • Tube Breakage: If tube breaks during operation, stop centrifuge immediately, allow rotor to stop fully, carefully remove fragments using forceps, disinfect rotor and chamber.
  • Sample Splash: If biological sample splashes, disinfect area immediately with appropriate disinfectant.
  • Rotor Imbalance: If excessive vibration occurs, stop centrifuge immediately, check rotor balance, rebalance samples.

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic components are combustible; electrical components present fire risk.
  • Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for electrical fires.
  • Fire Response: Unplug centrifuge immediately; do not use water on electrical fire.