UV-Vis Spectrophotometer (SP-UV1000)

WhatsApp Order
The UV-Vis Spectrophotometer (SP-UV1000) is a high-performance single-beam instrument engineered for accurate, reproducible analysis of nucleic acids, proteins, clinical chemistry analytes, and pharmaceutical compounds in clinical diagnostics, molecular biology, and pharmaceutical quality control. Covering a wavelength range of 190–1100 nm with automatic switching between tungsten and deuterium lamps, this spectrophotometer provides the analytical versatility required for routine and specialized laboratory workflows.
Every UV-Vis Spectrophotometer (SP-UV1000) is factory calibrated and supplied with a certificate of calibration, delivering exceptional photometric accuracy of ±0.003 A at 0.5 A and precision with photometric repeatability of ≤0.0015 A at the same absorbance. The instrument’s stability of ≤0.002 A/h at 500 nm after a 2-hour warm-up ensures reliable, drift-free measurements for endpoint and kinetic assays. A large 128 × 64 dot backlit LCD display provides clear data visualization, and the 4-position sample compartment accommodates standard 10 mm path length cuvettes, with optional holders available for path lengths from 5 to 100 mm.
Key user-focused features include automatic wavelength calibration via arrow keys to reduce user errors, data storage for up to 200 test data groups and 200 standard curves with automatic backup to prevent data loss during power interruption, and multi-function measurement modes including photometric, quantitative analysis, and multi-wavelength scanning. The optional Wave Professional software enables computer control, kinetics analysis, and nucleic acid/protein measurement functions.
The UV-Vis Spectrophotometer (SP-UV1000) is supplied with four glass and two quartz square cuvettes (3.5 mL) and includes USB and parallel ports for printer connection. The instrument is manufactured under ISO quality systems, and the manufacturer’s CNAS-certified calibration laboratory ensures measurement traceability and confidence in results.
For the clinical laboratory scientist, molecular biologist, and pharmaceutical quality control analyst, the UV-Vis Spectrophotometer (SP-UV1000) delivers the accuracy, stability, and versatility required for DNA/RNA purity assessment, protein quantification, enzyme kinetic assays, and routine clinical chemistry testing. For the patient, reliable spectrophotometric analysis ensures that diagnostic results are accurate and reproducible, directly supporting effective clinical decision-making, appropriate treatment selection, and confident disease monitoring.
Description

UV-Vis Spectrophotometer (SP-UV1000)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Nucleic Acid Quantification and Purity Assessment for Molecular Diagnostics
Primary Use: Provides a single-beam UV-Vis spectrophotometer with a dual light source (tungsten and deuterium lamps) covering a wavelength range of 190–1100 nm, used for the accurate quantification and purity assessment of DNA, RNA, and oligonucleotides in clinical molecular diagnostics, including infectious disease testing and genetic screening workflows.
How it helps: For the molecular diagnostics scientist, the UV-Vis Spectrophotometer (SP-UV1000) measures absorbance at 260 nm for nucleic acid concentration and automatically calculates 260/280 and 260/230 purity ratios, ensuring that extracted DNA or RNA meets quality standards for downstream PCR, qPCR, or sequencing. The large LCD display and automatic wavelength calibration reduce setup errors. For the patient, precise nucleic acid quantification and purity confirmation directly support accurate pathogen detection (e.g., HIV, hepatitis, COVID-19) and reliable genetic screening results, reducing the risk of false negatives caused by contaminated or degraded samples.
2. Protein Concentration Determination for Clinical Biochemistry
Primary Use: Enables the direct measurement of protein concentration via absorbance at 280 nm (A280 method) for purified proteins, antibodies, and serum samples, as well as colorimetric protein assays such as Bradford, BCA, and Lowry using visible wavelength detection.
How it helps: For the clinical biochemistry technologist, the UV-Vis Spectrophotometer (SP-UV1000) provides rapid, accurate protein quantification for patient serum, cerebrospinal fluid, and urine samples. The instrument’s photometric accuracy of ±0.003 A at 0.5 A ensures reliable results for total protein and albumin measurements. For the patient, accurate protein quantification supports diagnosis and monitoring of conditions such as nephrotic syndrome, liver disease, multiple myeloma, and nutritional disorders, enabling timely clinical interventions.
3. Enzymatic Activity and Kinetic Monitoring for Clinical Enzyme Assays
Primary Use: Performs time-scan (kinetics) measurements for monitoring enzymatic reactions over time, used for the clinical determination of enzyme activities including ALT, AST, ALP, GGT, LDH, and CK in patient serum samples.
How it helps: For the clinical chemistry laboratory scientist, the SP-UV1000’s kinetics mode tracks absorbance changes at specific wavelengths over time, allowing calculation of enzyme reaction rates. The instrument’s stability of ≤0.002 A/h after warm-up ensures consistent, drift-free kinetic measurements. For the patient undergoing liver function testing, cardiac enzyme panels, or metabolic disorder screening, accurate enzyme activity results directly guide diagnosis, treatment decisions, and disease progression monitoring.
4. Spectrophotometric Analysis of Blood and Serum Components for Clinical Chemistry
Primary Use: Used for the quantitative analysis of various blood and serum components, including glucose, cholesterol, triglycerides, bilirubin, creatinine, uric acid, and electrolytes, using endpoint measurement modes with Beer-Lambert law quantification.
How it helps: For the clinical chemistry technologist, the UV-Vis Spectrophotometer (SP-UV1000) measures the concentration of key metabolites by detecting the absorbance of colored reaction products generated by specific reagent kits. The instrument’s photometric range of -0.3 to 3.0 A accommodates a wide range of clinical sample concentrations. For the patient, reliable measurements of blood glucose, lipid panels, kidney function markers, and liver enzymes support routine health screening, chronic disease management, and acute care diagnostics directly at the point of sample processing.

SECONDARY & SUPPORTIVE USES

1. Urinalysis parameter quantification: Measures colorimetric reactions for urine test strips and liquid reagents, quantifying parameters including protein, glucose, ketones, bilirubin, urobilinogen, nitrite, leukocytes, and occult blood for routine urinalysis in clinical laboratories.
2. Therapeutic drug monitoring: Quantifies concentrations of pharmaceutical drugs in patient serum or plasma for drugs with narrow therapeutic windows, including antiepileptics, immunosuppressants, and certain antibiotics, using UV-visible absorption methods.
3. Cell density measurement for microbiology: Measures optical density (OD) at 600 nm (OD600) of bacterial and yeast cultures to monitor microbial growth, determine cell concentration, and optimize harvest timing in clinical microbiology laboratories.
4. Hemoglobin and bilirubin measurement in neonatal screening: Quantifies total and direct bilirubin levels in neonatal serum for jaundice assessment, and measures hemoglobin for anemia screening in newborn and pediatric populations.
5. Immunoassay endpoint detection: Serves as the detection platform for various clinical immunoassays including ELISA, where the spectrophotometer measures the final colored product absorbance to quantify antibody or antigen concentrations in patient samples.
6. Drug dissolution testing for pharmaceutical QC: Quantifies drug release from solid dosage forms in dissolution testing, measuring the concentration of active pharmaceutical ingredient in dissolution media over time for quality control release testing.
7. Water quality testing for clinical utilities: Monitors the quality of purified water used in clinical laboratories, dialysis centers, and pharmacy compounding areas by measuring parameters such as chlorine, nitrate, and total organic carbon.
8. Veterinary diagnostic sample analysis: Perform the same range of clinical chemistry, protein quantification, and nucleic acid purity assessments for veterinary patient samples in animal health diagnostic laboratories.
9. Forensic toxicology screening: Quantifies drugs of abuse, alcohol markers, and certain poisons in biological specimens for forensic casework using validated UV-visible spectrophotometric methods.
10. POC test validation in research settings: Serves as a reference method for validating point-of-care testing devices and new diagnostic assays during research and development, providing gold-standard comparison data.
11. Food safety and nutritional analysis: Analyzes food and beverage samples for components such as caffeine, total polyphenols, vitamin C, and food colorants in food safety and nutritional testing laboratories.
12. Pharmaceutical raw material testing: Quantifies the concentration of active pharmaceutical ingredients and excipients during incoming raw material quality control, ensuring that pharmaceutical ingredients meet specification before use in drug manufacturing.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A single-beam, scanning UV-Vis spectrophotometer with dual-light-source configuration for routine laboratory analysis.
  • Designation: UV-Vis Spectrophotometer (SP-UV1000), DLAB UV-Vis Spectrophotometer (SP-UV1000), Scilogex SP-UV1000.
  • Key Components:
    • Tungsten lamp (visible range) and deuterium lamp (UV range) with automatic switching
    • 128 x 64 dot backlit LCD display with adjustable brightness
    • 4-position sample compartment for 10 mm path length cuvettes, with optional holders for 5-100 mm path lengths
    • USB port and parallel port for printer connection
    • Data storage RAM for up to 200 data groups and 200 standard curves, with automatic backup
    • Optional Wave Professional software for computer control and advanced analysis

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Optical system: Single beam with dual light source and automatic switching between tungsten and deuterium lamps
  • Spectral bandwidth: 4.0 nm
  • Wavelength range: 190–1100 nm (extended model) or 200–1000 nm (standard model)
  • Wavelength accuracy: ±2 nm
  • Wavelength repeatability: ≤1 nm
  • Photometric range: -0.3 to 3.0 A (absorbance) and 0 to 200% T (transmittance)
  • Photometric accuracy: ±0.003 A at 0.5 A; ±0.006 A at 1.0 A; ±0.5% T at 100% T
  • Photometric repeatability: ≤0.0015 A at 0.5 A; ≤0.003 A at 1.0 A; ≤0.25% T at 100% T
  • Stability: ≤0.002 A/h at 500 nm (after 2-hour warm-up)
  • Stray light: ≤0.2% T at 220 nm and 360 nm
  • Sample compartment: 4-position, standard 10 mm path length cuvettes (10 × 10 × 4.5 mm, 3.5 mL). Optional holders available for 5-100 mm path lengths
  • Data storage: Up to 200 test data groups and 200 standard curves stored in RAM; data retained after power failure
  • Wavelength calibration: Automatic wavelength setting with arrow keys to reduce user errors
  • Output interfaces: USB port and parallel port for printer connection
  • Power requirements: 110/220 VAC, 50/60 Hz, 120 W
  • Dimensions (L × W × H): 490 × 360 × 210 mm
  • Weight: 12–14 kg depending on model
  • Quality compliance: Manufactured under ISO standards; CNAS-certified calibration laboratory

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Durable benchtop enclosure with stable base for vibration-resistant measurements
  • Display: Large 128 × 64 dot backlit LCD screen with adjustable brightness for clear data visualization, including graphical display capabilities
  • Operation: Standalone operation with all functions executable directly from the instrument; auto wavelength setting via arrow keys for calibration
  • Sample loading: 4-position cuvette holder allowing multiple samples to be queued for sequential measurement
  • Measurement modes: Photometric mode (fixed wavelength), quantitative analysis (standard curve), multi-wavelength scanning, and time-scan kinetics (with optional software)
  • Data management: Large-capacity data storage with up to 200 data groups and 200 standard curves; automatic backup protects against data loss during power interruption
  • Portability: Benchtop unit weighing 12-14 kg; not designed for portable use but occupies standard laboratory benchtop footprint
  • Software compatibility: Optional Wave Professional software enables computer control, spectrum scanning, time scanning (kinetics), multi-wavelength scanning, and nucleic acid/protein measurement functions (compatible with SP-V1100/SP-UV1100)
  • Maintenance: Tungsten and deuterium lamps are user-replaceable; automatic lamp switching extends lamp life by optimizing usage based on wavelength
  • Included accessories: 4 glass square cuvettes (3.5 mL) and 2 quartz square cuvettes (3.5 mL)

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic (IVD) use; manufactured under ISO quality management systems; CNAS-certified calibration laboratory ensures measurement traceability
  • Lamp Safety: Tungsten and deuterium lamps operate at high temperatures; allow cooling before handling. UV radiation from deuterium lamp requires sample compartment cover to remain closed during operation
  • Electrical Safety: Compliant with IEC 61010 standard for laboratory electrical equipment; grounded power cord; 110/220 VAC selectable input
  • Chemical Safety: Sample compartment designed to contain minor spills; instrument body resistant to common laboratory chemicals
  • Data Integrity: Automatic data backup prevents loss during power interruption; data stored in non-volatile RAM
  • Quality Compliance: Each instrument undergoes factory calibration and is supplied with calibration certificate; traceable to international standards

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store in a clean, dry, dust-free environment at room temperature (15–30°C). Cover instrument when not in use to protect optics from dust
  • Installation: Place on a stable, vibration-free benchtop away from direct sunlight, heat sources, and strong magnetic fields; allow 2-hour warm-up before use for optimal stability
  • Cleaning: Wipe exterior surfaces with a soft, lint-free cloth slightly dampened with mild detergent or 70% isopropyl alcohol. Clean sample compartment after each use to remove spills. Do not spray liquids directly onto the instrument
  • Cuvette handling: Use only clean, scratch-free cuvettes. Quartz cuvettes are required for UV measurements below 340 nm; glass cuvettes are suitable for visible range measurements above 340 nm
  • Lamp maintenance: Tungsten and deuterium lamps have finite lifetimes (typically 2000 hours). Replace lamps when intensity decreases or at manufacturer-recommended intervals. Allow lamps to cool before replacement
  • Warm-up procedure: Turn on instrument and allow 2-hour warm-up before performing critical measurements to achieve specified stability of ≤0.002 A/h
  • Wavelength calibration: Perform automatic wavelength calibration before each use using the auto-setting function accessible via arrow keys
  • Standard curve preparation: Prepare fresh calibration standards for quantitative analysis; store up to 200 standard curves in instrument memory for repeated use
  • Software updates: Contact manufacturer for optional Wave Professional software installation for advanced functions including kinetics and nucleic acid/protein measurement

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Quantitative and qualitative analysis of biomolecules (nucleic acids, proteins), clinical chemistry analytes (glucose, cholesterol, bilirubin, creatinine, enzymes), and pharmaceutical compounds in clinical diagnostics, molecular biology, pharmaceutical quality control, and research laboratories.
  • Clinical Role: An essential instrument for clinical diagnostic laboratories, molecular diagnostics labs, biochemistry departments, hospital central laboratories, pharmaceutical QC facilities, and research institutions. Critical for patient sample analysis (DNA/RNA purity, protein concentration, enzyme activities, metabolite quantification) where accurate, reproducible spectrophotometric measurement is mandatory for diagnosis, treatment monitoring, and quality control.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • UV Radiation Hazard: The deuterium lamp emits UV radiation. Always keep the sample compartment cover closed during operation. Never stare directly at the light source
  • Electrical Safety: Do not operate with wet hands. Disconnect power before cleaning or performing lamp replacement. Use only the supplied power cord and ensure proper grounding
  • Hot Surface Hazard: Tungsten and deuterium lamps become extremely hot during operation. Allow lamps to cool for at least 30 minutes before handling or replacement
  • Chemical Hazard: Handle all reagents, standards, and patient samples according to laboratory safety protocols. Wear appropriate PPE including gloves and lab coat. Clean spills immediately to prevent damage to instrument optics
  • Cuvette Safety: Handle cuvettes with care; broken glass or quartz can cause injury. Dispose of broken cuvettes in sharps containers
  • Sample Containment: Ensure cuvettes are properly seated in the sample holder to prevent spillage. Use sealed cuvettes for volatile or hazardous samples
  • Stability Requirement: Allow 2-hour warm-up before critical measurements to achieve specified stability specifications
  • Training Requirement: Only trained laboratory personnel should operate the SP-UV1000 for clinical diagnostic applications

2. FIRST AID MEASURES

  • UV Exposure to Eyes: If the sample compartment cover is opened during operation and UV exposure is suspected, rest eyes and seek ophthalmologic evaluation if symptoms (pain, redness, photophobia) develop
  • Skin Contact with Hot Lamp: If burn occurs from contact with hot lamp, cool the area with cool running water for 15 minutes and seek medical attention for severe burns
  • Chemical Splash to Eyes: If chemical sample splashes into eyes during cuvette handling, flush immediately with water for 15 minutes and seek medical attention
  • Skin Contact with Chemical Sample: Wash contaminated skin with soap and water thoroughly; if irritation or signs of infection develop, seek medical evaluation
  • Sharps Injury: If broken cuvette glass punctures skin, wash wound thoroughly and follow facility's exposure management protocol for bloodborne pathogens if sample is biological
  • Electrical Shock: If electrical incident occurs, disconnect power immediately. Do not touch person until power is disconnected. Seek emergency medical attention

3. FIRE FIGHTING MEASURES

  • Flammability: The instrument's plastic housing and internal components are combustible. Lamps operate at high temperatures and can ignite flammable materials in close proximity
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires. Do not use water on electrical fires
  • Fire Response: Primary fire hazard is flammable reagents or solvents being measured. Follow laboratory fire safety protocols. Disconnect power if safe to do so
  • Special Protective Equipment: Firefighters should wear self-contained breathing apparatus and full protective gear when fighting fires in laboratory settings