Fixed Speed Vortex Mixer (MX-F)

WhatsApp Order
The Fixed Speed Vortex Mixer (MX-F) is a compact, reliable benchtop vortex mixer designed for general laboratory mixing applications in clinical diagnostic, molecular biology, and research laboratories . Operating at a fixed speed of 3000 rpm with a 4 mm orbit diameter, this vortex mixer provides consistent, reproducible mixing of blood collection tubes, reagents, buffers, and biological samples .
Key features include two operating modes—touch activation (press tube into cup head for immediate mixing) for quick, on-demand mixing of individual tubes, and continuous operation mode (switch-activated) for extended mixing of larger volumes or multiple samples . The universal voltage (100-240V, 50/60Hz) and low power consumption (60W) enable use in laboratories worldwide without voltage conversion . The impact-resistant plastic housing with rubber suction feet provides stability and prevents “walking” during operation .
For the clinical laboratory scientist and phlebotomist, the Fixed Speed Vortex Mixer (MX-F) ensures immediate mixing of blood collection tubes after venipuncture—preventing clot formation and ensuring accurate hematology, coagulation, and chemistry results . For the molecular biologist, the MX-F facilitates resuspension of nucleic acid pellets, mixing of PCR reaction components, and homogenization of buffers for diagnostic assays . The optional multi-tube head for 0.2 mL PCR strips and flat rubber pad for larger vessels extend the versatility of this fixed-speed mixer .
With its compact footprint (127 × 130 × 160 mm), lightweight design (2.0 kg), and simple operation, theFixed Speed Vortex Mixer (MX-F) is an essential tool for clinical diagnostic laboratories, molecular diagnostics labs, blood banks, physician office laboratories, and research facilities requiring reliable, consistent vortex mixing for patient sample preparation and diagnostic testing .
Description

 Fixed Speed Vortex Mixer (MX-F)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Rapid Mixing of Blood Collection Tubes for Anticoagulant Distribution
  • Primary Use: Provides a fixed-speed vortex mixer (3000 rpm) designed for rapid, thorough mixing of blood collection tubes immediately after venipuncture to ensure proper distribution of anticoagulants (EDTA, heparin, citrate) throughout the blood sample .
  • How it helps: For the phlebotomist and clinical laboratory technician, the MX-F ensures immediate and consistent mixing of blood samples—preventing clot formation, micro-clots, and inaccurate hematology or coagulation test results. For the patient, proper mixing of blood collection tubes ensures that complete blood count (CBC), coagulation studies (PT/PTT), and chemistry panels accurately reflect their clinical status, reducing the need for repeat blood draws due to clotted or improperly mixed specimens .
2. Reagent and Sample Homogenization for Diagnostic Assays
  • Primary Use: Used to rapidly mix reagents, buffers, and biological samples (serum, plasma, urine) before analysis in immunoassays, clinical chemistry analyzers, and point-of-care testing devices .
  • How it helps: For the clinical laboratory scientist, the MX-F’s fixed speed (3000 rpm) and continuous or touch-activated operation provide consistent, reproducible mixing of diagnostic reagents—ensuring homogeneous distribution of analytes and reducing inter-assay variability. For the patient undergoing diagnostic testing for cardiac biomarkers (troponin), metabolic panels, or infectious diseases, consistent reagent mixing improves the accuracy and reliability of test results that guide treatment decisions .
3. Liquid Resuspension of Cell Pellets and Precipitates
  • Primary Use: Facilitates rapid resuspension of cell pellets, protein precipitates, and nucleic acid pellets in appropriate buffers for downstream molecular diagnostics and biochemical analysis .
  • How it helps: For the molecular biologist and clinical laboratory scientist, the MX-F’s fixed-speed vortexing action (3000 rpm) effectively dislodges and resuspends pelleted materials—ensuring uniform distribution of cells or analytes in suspension before aliquoting for PCR, ELISA, or other diagnostic platforms . For the patient, uniform resuspension ensures that aliquots taken for testing accurately represent the original specimen, reducing the risk of false-negative or false-positive results due to heterogeneous sample distribution.
4. Mixing of Microcentrifuge Tubes and PCR Strips
  • Primary Use: Equipped with a standard cup head (for individual microcentrifuge tubes) and an optional multi-tube head (for 0.2 mL PCR strip tubes), enabling efficient mixing of small-volume samples used in molecular diagnostics .
  • How it helps: For the molecular diagnostics technologist, the MX-F’s versatility allows mixing of individual samples (1.5-2.0 mL microcentrifuge tubes) and 0.2 mL PCR strip tubes without changing work surfaces—streamlining high-throughput PCR setup workflows. For the patient undergoing PCR-based testing for COVID-19, influenza, hepatitis, or other infectious diseases, consistent mixing of PCR reaction components ensures reliable amplification and accurate diagnostic results .

SECONDARY & SUPPORTIVE USES

1. Homogenization of Liquid Samples for Chemistry Analyzers: Used to mix serum, plasma, or urine samples before loading onto automated chemistry analyzers to ensure representative sampling .
2. Resuspension of lyophilized (Freeze-Dried) Controls and Calibrators: Used to dissolve lyophilized quality control materials and calibrators in clinical chemistry and immunoassay laboratories .
3. Mixing of Buffers and Diluents for Manual Assays: Supports manual preparation of working reagents, dilutions, and standard curves for ELISA, RIA, and other manual immunoassay formats.
4. Homogenization of Viscous Liquids (Glycerol, Protein Solutions): Used to mix viscous solutions to ensure homogeneous distribution of components before aliquoting .
5. Dissolution of Powders and Crystalline Materials: Used to accelerate dissolution of powdered reagents, salts, and crystalline materials into liquid solvents .
6. Preparation of Suspensions for Turbidimetric Assays: Used to mix bacterial suspensions and latex bead suspensions for turbidimetric and nephelometric immunoassays.
7. Mixing of Lipid and Lipoprotein Fractions: Supports homogenization of lipid samples for cholesterol, triglyceride, and HDL/LDL fraction analysis .
8. Quality Control Sample Preparation: Used to mix QC samples before analysis to ensure batch-to-batch consistency in clinical laboratory quality assurance programs.
9. Point-of-Care Testing Support: Provides reliable mixing of test reagents and patient samples in point-of-care settings (physician offices, clinics, emergency departments) .
10. Blood Gas and Electrolyte Sample Mixing: Used to mix heparinized blood samples before blood gas and electrolyte analysis to ensure even distribution of anticoagulant .
11. Research and Academic Laboratories: Provides fixed-speed vortex mixing for routine laboratory applications in research and teaching laboratories.
12. Veterinary Diagnostic Laboratory: Supports mixing of blood, urine, and other biological specimens for animal health testing .
13. Blood Bank and Transfusion Medicine: Used to mix reagent red blood cells, antisera, and patient samples for compatibility testing and antibody screening .
14. Pharmaceutical Quality Control: Supports mixing of drug formulations, dissolution media, and QC samples in pharmaceutical testing laboratories.
15. Environmental and Food Testing Laboratories: Used to mix water, soil, and food extracts for microbiological and chemical analysis.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A fixed-speed (3000 rpm) benchtop vortex mixer with touch activation and continuous operation modes, designed for general laboratory mixing of blood tubes, reagents, and biological samples .
  • Designation: MX-F Fixed Speed Vortex Mixer, Fixed Speed Vortex Mixer, Laboratory Vortex Mixer, Benchtop Vortex Mixer, DLAB Vortex Mixer .
  • Key Components:
    • Drive Motor: Heavy-duty electric motor with fixed speed 3000 rpm .
    • Operating Modes: Touch activation (press down to start) and continuous operation (switch on) .
    • Cup Head: Standard cup head for individual microcentrifuge tubes and vials .
    • Optional Accessories: Multi-tube head for 0.2 mL PCR strip tubes, flat rubber pad for larger vessels .
    • Housing: Impact-resistant plastic body with rubber suction feet for stability .
    • Power Switch: Rocker switch for continuous operation mode activation .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Speed: Fixed 3,000 rpm .
  • Operating Modes: Touch (pressure-activated) and Continuous (switch-activated) .
  • Orbit Diameter: 4 mm (standard vortex mixing action) .
  • Capacity: Standard cup head accommodates individual tubes (0.2 mL to 50 mL depending on accessory) .
  • Voltage/Frequency: 100-240V, 50/60Hz (universal voltage) .
  • Power: 60W .
  • Dimensions (W × D × H): 127 × 130 × 160 mm .
  • Weight: 2.0 kg .
  • Noise Level: Low-noise operation suitable for clinical laboratory environments .
  • Footing: Rubber suction feet prevent "walking" during operation .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Impact-resistant plastic body with sealed electronics for spill protection.
  • Operating Modes: Touch activation for quick mixing of individual tubes; continuous mode for extended mixing of larger volumes .
  • Control: Simple rocker switch for continuous mode; pressure-activated for touch mode .
  • Cooling: Built-in cooling fan for extended continuous operation .
  • Stability: Rubber suction feet provide secure benchtop placement, preventing movement during operation .
  • Portability: Compact footprint (127 × 130 × 160 mm) and light weight (2.0 kg) for easy benchtop placement .
  • Maintenance: Simple external cleaning; no routine internal maintenance required.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards .
  • Safety Features: Enclosed motor with thermal protection; sealed housing prevents liquid ingress into electronics .
  • Electrical Safety: 60W low-power consumption; universal voltage (100-240V) for international use .
  • Noise Control: Low-noise operation minimizes distractions in clinical laboratory settings.
  • Stability: Rubber suction feet prevent accidental displacement during operation .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture.
  • Cleaning: Wipe exterior with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization ; disconnect power before cleaning .
  • Inspection: Inspect power cord for damage before each use; check rubber feet for wear .
  • Operation: For touch mode, press tube firmly into cup head until motor activates; for continuous mode, switch rocker switch to ON position .
  • Accessories: Optional multi-tube head for 0.2 mL PCR strips and flat rubber pad for larger vessels available separately .
  • Spill Management: If liquid spills onto unit, disconnect power immediately, clean thoroughly, allow to dry before reuse .

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Mixing of blood collection tubes, reagents, biological samples, and resuspension of pellets for clinical diagnostic laboratories, molecular diagnostics, point-of-care testing, and research applications .
  • Clinical Role: Essential mixing equipment in clinical diagnostic laboratories, hospital laboratories, physician office laboratories, blood banks, molecular diagnostics labs, and research facilities .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources .
  • Spill Protection: Use appropriate tube sealing to prevent sample leakage into the mixer head; clean spills immediately .
  • Operation Mode: For continuous operation, ensure switch is in OFF position before plugging in unit .
  • Tube Selection: Use appropriate tube size for cup head; do not force oversized tubes into cup head .
  • Stability: Ensure rubber suction feet are clean and dry for secure benchtop placement; replace worn feet as needed .
  • Temperature: Unit may become warm after extended continuous operation; allow to cool between uses .
  • Training: Only trained laboratory personnel should operate the MX-F for clinical diagnostic applications .

2. FIRST AID MEASURES

  • Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water .
  • Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel .
  • Mechanical Failure: If unit fails to operate or makes abnormal noise, disconnect power, check for obstruction, contact service if issue persists .
  • Chemical Spill: If corrosive chemicals spill on unit, wipe immediately with appropriate neutralizer, dry thoroughly before reconnecting power .

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn .
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires .
  • Fire Response: Unplug unit immediately; do not use water on electrical fire .