Intelligent Linear Decolorizing Shaker (SK-L180-S)

WhatsApp Order
The Intelligent Linear Decolorizing Shaker (SK-L180-S) is a digital linear reciprocating shaker featuring 20mm amplitude, variable speed control (40-200 rpm), dual independent LED displays, programmable timer (1 minute to 99 hours 59 minutes), and a maintenance-free brushless DC motor, designed for uniform mixing of electrophoresis gels, Western blot membranes, and biological samples in clinical diagnostic and research laboratories .
Key features include linear reciprocating shaking action at 20mm amplitude for thorough, uniform mixing , dual independent LED displays for simultaneous monitoring of speed and time, programmable timer with automatic stop (1 minute to 99 hours 59 minutes) , and a maintenance-free brushless DC motor for quiet, reliable operation . The 268 × 268 mm work platform securely holds culture dishes, flasks, beakers, and blotting containers .
The Intelligent Linear Decolorizing Shaker (SK-L180-S) accommodates a variety of laboratory vessels, with a maximum load capacity of 2 kg and universal voltage (100-240V, 50/60Hz) enabling use in laboratories worldwide without voltage conversion . The cold room and incubator compatibility (5-40°C operating temperature, 80% RH) allows sample mixing under controlled temperature conditions for temperature-sensitive applications. The IP20 protection rating provides durability against dust and moisture in typical laboratory environments .
For the clinical laboratory scientist and molecular biologist, the Intelligent Linear Decolorizing Shaker (SK-L180-S) supports electrophoresis gel decolorization and staining (Coomassie blue, silver nitrate), Western blot membrane washing and antibody incubations, Southern and Northern blot hybridization reactions, clinical sample preparation, and general liquid mixing for aeration and extraction applications .
Universal voltage (100-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion, while the compact footprint (294 × 348 × 123 mm) and moderate weight (3.4 kg) allow easy benchtop placement . The whisper-quiet brushless DC motor and safety speed protection ensure minimal noise, extended service life, and enhanced laboratory safety .
For the patient undergoing diagnostic testing for infectious diseases, genetic disorders, or cancer biomarkers, the Intelligent Linear Decolorizing Shaker (SK-L180-S) uniform linear mixing ensures consistent gel staining, reproducible antibody incubations, and accurate nucleic acid hybridization results—supporting reliable diagnostic outcomes that guide appropriate treatment decisions across molecular diagnostics, immunology, and cell biology applications.
Description

 Intelligent Linear Decolorizing Shaker (SK-L180-S)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Electrophoresis Gel Decolorization and Staining
  • Primary Use: Provides a linear reciprocating shaker with 20mm amplitude, variable speed control (40-200 rpm), and dual LED displays for time and speed, specifically designed for uniform mixing of electrophoresis gel staining and destaining solutions .
  • How it helps: For the molecular biologist and clinical laboratory scientist, the Intelligent Linear Decolorizing Shaker (SK-L180-S) linear shaking action ensures even distribution of Coomassie blue, silver nitrate, and other staining solutions across polyacrylamide and agarose gels—reducing background noise and improving band visualization for diagnostic protein analysis . For the patient undergoing confirmatory testing for genetic disorders or infectious diseases, clear and consistent gel results support accurate diagnosis.
2. Western Blot Membrane Washing and Antibody Incubations
  • Primary Use: Used for uniform washing of Western blot membranes and incubation of antibodies, ensuring complete and even reagent coverage without damaging delicate membranes .
  • How it helps: For the immunology technologist, the gentle linear motion (20mm amplitude) at adjustable speeds (40-200 rpm) provides thorough yet non-damaging agitation for membrane washing steps—effectively reducing background noise and enhancing signal specificity in diagnostic immunoblots . For the patient undergoing confirmatory testing for HIV, Lyme disease, or autoimmune conditions, consistent membrane processing ensures accurate detection of disease-specific antibodies that guide diagnosis and treatment monitoring.
3. DNA Hybridization and Molecular Biology Applications
  • Primary Use: Supports uniform mixing for Southern blot, Northern blot, and in-situ hybridization protocols, ensuring consistent reagent distribution across membranes and slides .
  • How it helps: For the molecular biologist, the Intelligent Linear Decolorizing Shaker (SK-L180-S) programmable timer (1 minute to 99 hours 59 minutes) allows automated, reproducible hybridization steps—reducing operator-dependent variability and improving nucleic acid detection sensitivity . For the patient undergoing genetic testing for inherited disorders or cancer biomarkers, reliable hybridization results support accurate molecular diagnosis.
4. Clinical Sample Preparation and General Mixing
  • Primary Use: Designed for mixing liquid samples in culture dishes, flasks, and beakers, supporting aeration and extraction applications in clinical diagnostic workflows .
  • How it helps: For the clinical laboratory scientist, the 2kg load capacity and universal voltage (100-240V, 50/60Hz) allow versatile sample processing—from gentle mixing of patient serum samples to more vigorous extraction procedures . For the patient, reliable sample preparation ensures that diagnostic test results accurately reflect the clinical specimen, reducing the risk of false results due to heterogeneous sample distribution.
5. Cold Room and Incubator Compatibility
  • Primary Use: Designed for use in cold rooms (5-40°C, 80% RH), CO₂ incubators, and environmental chambers, allowing sample mixing under controlled temperature conditions .
  • How it helps: For the clinical laboratory scientist and research technician, the Intelligent Linear Decolorizing Shaker (SK-L180-S) wide operating temperature range (5-40°C) allows sample mixing in cold rooms for temperature-sensitive antibody binding reactions, as well as in incubators for cell culture and microbiology workflows. For the patient, temperature-controlled mixing preserves sample integrity for temperature-sensitive assays, supporting accurate diagnostic results for conditions requiring strict temperature control during sample processing.

SECONDARY & SUPPORTIVE USES

1. Cell Culture Maintenance: Supports gentle mixing for culture flasks and bottles, ensuring uniform distribution of nutrients and gases for optimal cell growth .
2. Immunoprecipitation and Protein Extraction: Used for gentle mixing in immunoprecipitation protocols and protein extraction workflows requiring consistent, gentle agitation .
3. Liquid-Solid Suspension Homogenization: Used for mixing of cell pellets, tissue homogenates, and other liquid-solid suspensions in molecular preparation workflows .
4. ELISA Plate Incubation: Supports uniform mixing during ELISA plate incubation steps, reducing well-to-well variability in diagnostic immunoassays .
5. Microbial Culture Growth: Used for mixing bacterial and yeast cultures in flasks, ensuring uniform growth conditions and consistent cell density .
6. Gel Staining Protocols: Used for uniform distribution of Coomassie blue, silver nitrate, and other gel stains, ensuring consistent band visualization .
7. Blotting Membrane Washing: Supports uniform washing of Western, Southern, and Northern blot membranes, reducing background noise and improving signal specificity .
8. Aeration and Extraction Applications: Suitable for aeration of liquid cultures and extraction procedures requiring consistent agitation .
9. Clinical Sample Preparation: Supports mixing of serum, plasma, and other biological fluids for clinical chemistry and immunoassay sample preparation .
10. Research and Academic Laboratories: Provides linear reciprocating mixing for diverse research applications in cell biology, molecular biology, and biochemistry.
11. Pharmaceutical Quality Control: Used for mixing of QC samples and reagents in pharmaceutical testing laboratories requiring gentle, uniform agitation .
12. Veterinary Diagnostic Laboratory: Supports mixing of biological specimens for animal health testing and infectious disease diagnosis.
13. Environmental and Food Testing Laboratories: Used for mixing of environmental extracts and food samples for microbiological and chemical analysis .
14. Safety Speed Protection: Equipped with safety speed protection that prevents misuse or sudden overload conditions, enhancing laboratory safety .
15. Maintenance-Free Operation: Brushless DC motor eliminates routine brush replacement, reducing maintenance downtime .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: An intelligent linear reciprocating decolorizing shaker with LED display, variable speed control (40-200 rpm), and programmable timer, designed for uniform mixing of electrophoresis gels, membranes, and biological samples in clinical diagnostic and research laboratories .
  • Designation: SK-L180-S Intelligent Linear Decolorizing Shaker, Linear Reciprocating Shaker, Laboratory Shaker, DLAB SK-L180-S, Decolorizing Shaker .
  • Key Components:
o Motion Type: Linear reciprocating (back-and-forth) shaking action .
o Work Platform: 268 × 268 mm work plate with anti-slip surface for secure vessel placement .
o Motor: Maintenance-free brushless DC motor .
o Display: Dual independent LED displays for simultaneous speed and timer viewing .
o Control: Digital control with programmable timer.
o Housing: Impact-resistant plastic body with non-slip base.

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Motion Type: Linear reciprocating (Linear Shaker) .
  • Amplitude: 20 mm .
  • Speed Range: 40-200 rpm (variable, adjustable) .
  • Speed Display: LED digital display .
  • Timer Display: LED digital display .
  • Timer Range: 1 minute to 99 hours 59 minutes (programmable) .
  • Maximum Load Capacity: 2 kg (including clamps) .
  • Work Platform Dimensions (W × D): 268 × 268 mm .
  • External Dimensions (W × D × H): 294 × 348 × 123 mm .
  • Motor Type: Brushless DC motor (maintenance-free) .
  • Motor Rating Input: 16W .
  • Motor Rating Output: 10W .
  • Total Power: 20W .
  • Voltage/Frequency: 100-240V, 50/60Hz (universal voltage) .
  • Weight: 3.4 kg .
  • Operating Temperature: 5-40°C (cold room and incubator compatible) .
  • Permissible Ambient Humidity: ≤80% RH .
  • Protection Class: IP20 .
  • Compatibility: Suitable for culture dishes, flasks, beakers, and blotting containers .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Impact-resistant plastic body with non-slip base for stable benchtop placement.
  • Motion Type: Linear reciprocating (back-and-forth) shaking action at 20mm amplitude for thorough, uniform mixing .
  • Work Platform: 268 × 268 mm work plate securely holds vessels in place during operation .
  • Display: Dual independent LED displays show real-time speed (40-200 rpm) and timer (1 minute to 99 hours 59 minutes) simultaneously .
  • Control System: Digital speed control; programmable timer with automatic stop at end of set time.
  • Timer: Programmable timer range 1 minute to 99 hours 59 minutes; ideal for extended experiments; unit automatically halts when timer reaches zero .
  • Noise Level: Quiet operation (brushless DC motor) minimizes distractions in clinical laboratory environment.
  • Operating Conditions: Can be used in cold rooms (5-40°C), CO₂ incubators, and environmental chambers .
  • Portability: Compact footprint (294 × 348 × 123 mm) and moderate weight (3.4 kg) for easy benchtop placement.
  • Maintenance: Brushless DC motor eliminates routine brush replacement .
  • Safety Features: Equipped with safety speed protection to prevent misuse or sudden overload conditions .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards.
  • Safety Features: Safety speed protection prevents misuse or sudden overload conditions; IP20 protection rating provides protection against solid objects >12mm .
  • Electrical Safety: Universal voltage (100-240V, 50/60Hz) for international use; 20W low power consumption; earthed power connection recommended .
  • Motor Type: Brushless DC motor provides maintenance-free, quiet, stable operation .
  • Timer Safety: Programmable timer (1 minute to 99 hours 59 minutes) with automatic stop at end of set time prevents over-mixing of sensitive samples.
  • Operating Conditions: 5-40°C ambient temperature; ≤80% relative humidity .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture.
  • Cleaning: Wipe work platform and housing with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; disconnect power before cleaning.
  • Inspection: Inspect power cord for damage before each use; check work platform for residue or wear; verify stability of benchtop placement.
  • Operation: Place unit on safe, stable surface; ensure operating voltage matches power supply; connect power cable; switch ON instrument.
  • Speed Setting: Set desired speed (40-200 rpm) using digital controls; LED display shows current speed setting .
  • Timer Setting: Set desired run time (1 minute to 99 hours 59 minutes); LED display shows current time setting; unit automatically halts when timer reaches zero .
  • Load Balancing: Distribute vessels evenly across work platform; do not exceed maximum load capacity (2 kg) .
  • Spill Management: If liquid spills onto unit, disconnect power immediately, clean thoroughly, allow to dry before reuse.
  • Incubator Use: Unit is suitable for use in CO₂ incubators and environmental chambers .

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Uniform linear reciprocating mixing for electrophoresis gel decolorization and staining, Western blot membrane washing, DNA hybridization, and general sample preparation in clinical diagnostic, molecular biology, and research laboratories .
  • Clinical Role: Essential mixing equipment in clinical diagnostic laboratories, molecular biology labs, immunology laboratories, pharmaceutical research laboratories, and academic research institutions.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources.
  • Load Limits: Do not exceed maximum load capacity (2 kg); ensure load is evenly distributed across work platform to prevent imbalance .
  • Spill Protection: Use appropriate vessel caps or seals to prevent sample leakage; clean spills immediately.
  • Speed Selection: Select appropriate speed for sample type (40-200 rpm); use lower speeds (40-80 rpm) for delicate membrane washing steps; use higher speeds (150-200 rpm) for gel staining/destaining solutions.
  • Cold Room/Incubator Use: Ensure instrument is placed on stable surface within cold room or incubator; operating temperature range 5-40°C; permissible ambient humidity ≤80% RH .
  • Timer Use: Set appropriate time for mixing protocol; do not exceed recommended mixing times for sensitive samples; unit automatically halts when timer reaches zero.
  • Platform Cleaning: Clean work platform regularly to prevent residue buildup and maintain vessel stability.
  • Training: Only trained laboratory personnel should operate the SK-L180-S for clinical diagnostic applications.

2. FIRST AID MEASURES

  • Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
  • Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel.
  • Mechanical Failure: If unit fails to operate or makes abnormal noise, disconnect power, check for obstruction, contact service if issue persists.
  • Chemical Spill: If corrosive chemicals spill on unit, disconnect power immediately, wipe with appropriate neutralizer, dry thoroughly before reconnecting power.

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn.
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires.
  • Fire Response: Unplug unit immediately; do not use water on electrical fire.