Pipette Filler (Levo ME)

WhatsApp Order
The Pipette Filler (Levo ME) is a lightweight, ergonomic motorized pipette controller from DLAB that provides comfortable, efficient, and precise liquid handling. Designed for use with all common glass or plastic serological pipettes (0.1–100 mL), this handheld device is a versatile tool for any laboratory.
For the laboratory scientist, the  Pipette Filler (Levo ME) offers significant advantages. Its powerful motor provides fast aspiration (25 mL in under 7 seconds), dramatically improving workflow efficiency. The two operating buttons allow independent, stepless speed control for both aspiration and dispensing, giving technicians precise control to avoid foaming or splashing. The lightweight (200 g) design and ergonomic shape minimize hand strain during prolonged use. A replaceable 0.45 µm hydrophobic filter prevents over-aspiration and protects against aerosol contamination.
The device is powered by a long-lasting lithium-ion battery that provides >8 hours of intermittent use on a 2–3 hour charge, and it can be used while charging to prevent downtime. For aseptic applications, the silicone adapter and nose cone can be removed and autoclaved. For the patient, the consistent precision and contamination-control features of the Levo ME help ensure accurate, reliable, and timely diagnostic results.
Description

Pipette Filler (Levo ME)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Motorized Aspiration for Efficient Liquid Transfer
  • Primary Use: Provides a motorized, handheld serological pipette controller designed for fast, efficient aspiration and dispensing of liquids in clinical and research laboratories, compatible with glass or plastic serological pipettes (0.1–100 mL).
  • How it helps: For the clinical laboratory scientist, the Levo ME’s powerful motor reduces the time and physical effort required for large-volume liquid transfer tasks. It can aspirate 25 mL of liquid in under 7 seconds, significantly streamlining workflows in diagnostic settings. The motorized aspiration provides consistent suction, which is critical for preventing the introduction of air bubbles that might compromise the accuracy of volumetric measurements. For the patient, this efficiency contributes to faster, more consistent sample processing, supporting timely diagnostic reporting.
2. Adjustable Aspiration and Dispensing Speeds for Versatile Liquid Handling
  • Primary Use: Features independently controlled upper and lower buttons for aspiration and dispensing, allowing the user to adjust speeds steplessly according to the task and liquid viscosity.
  • How it helps: For the laboratory technician, the ability to fine-tune speed with the fingertips can prevent splashing or foaming, which is crucial for handling sensitive protein solutions or cell cultures. The separate controls for aspiration and dispensing provide a high level of tactile precision. For the patient, this reduces the risk of sample degradation due to mechanical stress, ensuring that the specimen tested accurately represents their biological condition.
3. Long Battery Life and Low Weight for Extended Use
  • Primary Use: Powered by a high-capacity lithium-ion battery that provides more than 8 hours of intermittent use on a 2–3 hour charge (and can be used while charging), while weighing approximately 200 grams (approx. 0.44 lbs).
  • How it helps: For the laboratory manager, the long battery life supports full daily shifts without recharging, and the option to use it while charging eliminates downtime. The lightweight design minimizes hand fatigue, reducing the risk of repetitive strain injury (RSI) during high-throughput tasks. For the patient, a well-rested and comfortable technician is better able to maintain consistent technique and focus, contributing to the overall reliability of diagnostic assays.
4. Replaceable Filter to Prevent Aerosol Contamination
  • Primary Use: Equipped with a replaceable 0.45 µm hydrophobic filter that protects the internal mechanism from liquid overflow and prevents the escape of biohazardous aerosols.
  • How it helps: For the biosafety officer and laboratory personnel, this filter is a critical safety feature when handling infectious samples or volatile reagents. It serves as a barrier, safeguarding both the equipment and the user from potential contamination. For the patient, this filter helps prevent cross-contamination between samples, supporting the generation of accurate and reliable test results.
5. Gravity or Motorized Dispensing with Blow-Out Function
  • Primary Use: Offers a choice between motor-assisted dispensing for controlled, step-by-step release or gravity-based dispensing for rapid output, with a dedicated “blow-out” function to expel the final drop from the pipette tip.
  • How it helps: For the research scientist, the motor control allows for precise, drop-by-drop dispensing, which is essential for layering reagents or filling microplates. The gravity dispensing mode is ideal for rapid, large-volume transfers. The blow-out function ensures complete sample delivery, which is critical for accurate quantitative analysis. For the patient, this versatility ensures that the right tool is available for every laboratory procedure, supporting the overall accuracy of diagnostic and research assays.

SECONDARY & SUPPORTIVE USES

1. Cell Culture and Media Transfer: Used in cell culture laboratories for the sterile transfer of media, buffers, and reagents, helping to maintain aseptic conditions.
2. Clinical Chemistry and Sample Preparation: Used to aliquot patient sera, plasma, or urine samples for various diagnostic panels and to prepare reagents for automated analyzers.
3. Microbiology and Bacteriology: Used to transfer liquid media, broths, and bacterial suspensions to tubes or plates for culture and antimicrobial susceptibility testing (AST).
4. Pharmaceutical Quality Control (QC): Used to transfer test solutions, dissolution media, and QC samples during the analysis of drug products, ensuring accurate dosing and purity.
5. Analytical Chemistry Laboratories: Used for the precise transfer of solvents, standards, and samples for techniques such as HPLC, GC, and ICP-MS.
6. Blood Bank and Transfusion Medicine: Used to transfer reagents and patient samples for blood typing, cross-matching, and antibody screening.
7. Veterinary Diagnostic Laboratories: Assists with the transfer of samples and reagents for diagnostic testing of animal diseases, supporting animal health and public health surveillance.
8. Food and Beverage Testing: Used to transfer food extracts, buffers, and reagents for quality control and safety testing, including tests for pathogens, allergens, and nutritional content.
9. Educational and Research Institutions: A valuable teaching tool for students to learn accurate liquid handling techniques and a reliable workhorse for routine laboratory tasks.
10. Vaccine Development and Production: Used in the preparation of culture media, antigens, and formulations during vaccine research and manufacturing.
11. Environmental Testing Laboratories: Used to transfer water, soil, and effluent samples for chemical and microbiological analysis, helping to monitor environmental safety.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A motorized, handheld serological pipette controller designed for efficient and precise liquid handling using standard glass or plastic pipettes.
  • Designation: Levo ME Pipette Filler, Motorized Pipette Controller, Serological Pipettor, DLAB Levo ME.
  • Key Components:
    • Aspiration Button: Upper concave trigger for motorized liquid uptake (speed can be adjusted steplessly).
    • Dispensing Button: Lower concave trigger for controlled, motorized liquid release.
    • Blow-Out Button: Separate mechanism to expel the final drop from the pipette tip, ensuring complete sample delivery.
    • Silicone Adapter & Nose Cone: The liquid-contact parts are designed to be fully autoclavable for sterilization.
    • Replaceable Hydrophobic Filter: A 0.45 µm PES membrane filter that prevents over-aspiration and aerosol contamination.
    • Charging Stand: Allows the device to be stored upright while charging, saving bench space.
    • Lithium-ion Battery: High-capacity rechargeable battery for extended wireless operation.
    • Ergonomic Housing: Lightweight body (approx. 200 g) designed for comfortable single-handed use.
    • **Button Pad: Two separate silicone pads for pressure-sensitive speed adjustment (speed increases with increased pressure).

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Pipette Type & Volume Compatibility: For use with glass or plastic serological pipettes (0.1–100 mL) and Pasteur pipettes.
  • Aspiration Speed: Aspirates 25 mL of water in less than 7 seconds.
  • Dispensing Speed: Dispensing can be performed by gravity or by motor (pressure-controlled for fine adjustment).
  • Blow-Out Function: Allows complete emptying of the pipette tipafter gravity dispensing) to deliver the last drop.
  • Battery Type: Lithium-ion (Li-ion), with a service life of >8 hours of intermittent use per full charge.
  • Charging Time: Recharges fully in 2–3 hours.
  • Protective Filter: Equipped with a replaceable 0.45 μm hydrophobic filter.
  • Weight: Approximately 200 g (approx. 0.44 lbs), contributing to a lightweight, ergonomic feel.
  • Autoclavable Parts: The silicone adapter and the device's nose cone are fully autoclavable at 121°C for sterilization.
  • Voltage: Universal voltage (100-240V) power adapter included.

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Robust chemical-resistant housing for durability in demanding laboratory environments.
  • Operation: Ergonomic single-handed operation with pressure-sensitive speed control. Aspiration and dispensing speeds are independently controlled and can be adjusted steplessly .
  • Filtration: The 0.45 μm hydrophobic filter protects internal components and prevents the escape of biohazardous aerosols.
  • Charging: Handpiece can be used immediately while charging, minimizing downtime.
  • Portability: Lightweight, battery-powered unit for easy use on the bench or inside a biosafety cabinet.
  • Battery Status: An LED indicator light on the handpiece shows the current battery status and confirms the device is charging.
  • Sterilization: The silicone nose cone adapter can be removed and autoclaved to prevent cross-contamination between users or applications.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; CE certified.
  • Safety Features: The hydrophobic filter acts as a critical safety barrier, trapping aerosols and preventing liquid from entering the internal mechanism, thus protecting both the user and the equipment.
  • Electrical Safety: Low-voltage operation with a certified AC adapter and an integrated lithium-ion battery management system.
  • Chemical Resistance: Housings made from durable, chemical-resistant plastics to withstand long-term contact with solvents and disinfectants.

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store the pipette controller upright on its included charging stand when not in use.
  • Cleaning: Wipe the external surfaces of the handpiece with 70% isopropyl alcohol. Ensure the device is disconnected from the charger during deep cleaning.
  • Autoclaving: Remove the silicone adapter and the nose cone; these components can be autoclaved at 121°C for 20 minutes for effective sterilization.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: The Levo ME is a motorized pipette filler designed for the rapid, efficient, and precise transfer of liquids using serological pipettes in high-throughput clinical, pharmaceutical, and research laboratories.
  • Clinical Role: An essential tool for sample preparation and liquid handling in clinical chemistry, molecular diagnostics, cell culture, and pharmaceutical quality control.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Chemical Compatibility: Ensure the silicone adapter, housing, and the filter are compatible with the solvents and reagents being used.
  • Proper Pipette Fit: Always ensure the serological pipette is securely inserted into the silicone adapter before use to prevent leakage or inaccurate volume aspiration.
  • Filter Integrity: Check that the hydrophobic filter is properly seated and dry before operation. A clogged or saturated filter will reduce suction performance and must be replaced.
  • Charging: Use only the supplied AC power adapter to charge the lithium-ion battery.
  • Autoclaving: Never attempt to autoclave the entire unit. Only remove and autoclave the silicone adapter and nose cone.

2. FIRST AID MEASURES

  • Sample Splash: If a biological or chemical sample splashes onto the skin, wash immediately with soap and water. If a splash enters the eyes, flush with copious amounts of water for at least 15 minutes and seek medical attention.
  • Chemical Exposure: If a large volume of a hazardous chemical is aspirated, refer to the specific chemical's Safety Data Sheet (SDS) for detailed first-aid instructions.
  • Mechanical Injury: If the pipette tip punctures the skin, wash the wound thoroughly and follow your facility's exposure management protocol for bloodborne pathogens.

3. FIRE FIGHTING MEASURES

  • Flammability: The plastic components of the pipette controller are combustible. The primary fire risk comes from the flammable reagents being used in the laboratory.
  • Extinguishing Media: Use a multi-purpose ABC dry chemical fire extinguisher, CO₂, or alcohol-resistant foam for fires involving electrical equipment or flammable liquids.