High Speed Micro Centrifuge (D3024)

WhatsApp Order
The High Speed Micro Centrifuge (D3024) is a benchtop high-speed centrifuge designed for clinical diagnostic sample processing, molecular biology applications, and research laboratory use. With a maximum speed of 15,000 rpm (up to 21,380 × g), this centrifuge provides the speed and capacity needed for high-throughput sample processing in moderate to large volume diagnostic laboratories.
The standard A24-2 rotor accommodates 24 × 1.5/2.0 mL microcentrifuge tubes with 0.5 mL and 0.2 mL adapters, while optional rotors support 0.2 mL × 36, 0.5 mL × 36, PCR strips × 4, 5 mL × 12, and 5 mL × 18 configurations. The LCD display with touch panel control allows precise speed (500-15,000 rpm, step: 100 rpm) and time (20 seconds to 99 minutes) adjustment.
For the clinical laboratory scientist and medical technologist, the D3024 facilitates serum and plasma separation for blood chemistry testing, coagulation studies, and lipid panels. It supports nucleic acid extraction and purification for molecular diagnostics, PCR sample preparation (with spin-down and continuous operation modes), protein precipitation steps for biochemical assays, and cell pelleting for culture processing.
The automatic imbalance detection, lid safety interlock, over-speed detection, over-temperature detection, and durable rotor construction ensure safe, reliable operation throughout years of daily laboratory use. With a quiet brushless DC motor (≤55 dB) and compact benchtop footprint (210 × 250 × 170 mm), the D3024 provides versatile, consistent performance for routine laboratory workflows supporting patient diagnosis and treatment monitoring.
Description

High Speed Micro Centrifuge (D3024)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. High-Throughput Blood Component Separation for Clinical Diagnostics
  • Primary Use: Provides a benchtop high-speed microcentrifuge with a 24-place rotor, enabling simultaneous processing of up to 24 microcentrifuge tubes for blood component separation, serum and plasma preparation for diagnostic laboratory analysis.
  • How it helps: For the medical technologist and clinical laboratory scientist, the D3024 significantly increases sample processing throughput compared to 12-place centrifuges—reducing hands-on time, accelerating turnaround for test results, and improving laboratory efficiency. For the patient, faster high-volume sample processing means receiving diagnostic results more quickly, enabling earlier diagnosis and treatment initiation.
2. Versatile Rotor System for Multiple Applications
  • Primary Use: Features an interchangeable rotor system with options for 24 × 1.5/2.0 mL tubes, 0.2 mL × 36, 0.5 mL × 36, 0.2 mL × 4 PCR strips, and 5 mL × 18 configurations, supporting a wide range of clinical and research applications.
  • How it helps: For the laboratory manager and molecular biologist, the multiple rotor options eliminate the need for several dedicated centrifuges—allowing a single instrument to handle routine blood work, PCR preparation, specialized assays, and clinical chemistry applications. For the patient, versatile equipment ensures that diagnostic testing can be performed efficiently across multiple test types without equipment delays.
3. PCR and Molecular Diagnostics Preparation
  • Primary Use: Accommodates 0.2 mL PCR tubes and 8-strip PCR tubes, with dedicated rotor options for high-throughput PCR preparation, enabling rapid spin-down of samples before polymerase chain reaction amplification.
  • How it helps: For the molecular biologist, the D3024 supports high-throughput PCR preparation with quick spin-down capabilities, continuous operation modes, and programmable run parameters—reducing pre- and post-PCR processing time. For the patient, reliable PCR sample preparation contributes to accurate diagnostic results for infectious diseases such as COVID-19, influenza, hepatitis, and other pathogens.
4. Precise Speed Control for Sensitive Applications
  • Primary Use: Programmable speed settings allow precise control from 500 to 15,000 rpm for applications requiring specific centrifugation parameters, such as platelet-poor plasma preparation, nucleic acid purification, and protein precipitation.
  • How it helps: For the clinical chemist and molecular diagnostics specialist, precise speed and time control ensures optimal separation of blood components, consistent nucleic acid yields, and reproducible results across batches. For the patient undergoing lipid profiling or coagulation studies, standardized sample processing reduces test variability and improves diagnostic accuracy.

SECONDARY & SUPPORTIVE USES

1. Blood Chemistry and Coagulation Testing: Used for serum and plasma separation for routine blood chemistry analysis and coagulation studies.
2. Lipoprotein and Lipid Panel Analysis: Supports sample preparation for lipid profiling and lipoprotein separation for cardiovascular risk assessment.
3. Nucleic Acid Extraction and Purification: Used in DNA and RNA extraction protocols for spin column-based purification in molecular diagnostics.
4. Plasmid Mini-Prep and Maxi-Prep Preparation: Supports quick spin-downs during plasmid isolation procedures for cloning and sequencing experiments.
5. Protein Precipitation and Biochemical Assays: Used for protein precipitation steps in biochemical assays and downstream analysis.
6. Phase Separation for Liquid-Liquid Extraction: Facilitates separation of organic and aqueous phases in extraction procedures.
7. Therapeutic Drug Monitoring: Supports sample preparation for therapeutic drug monitoring and toxicology screening.
8. Cytogenetic Analysis: Used for cell pelleting and chromosome preparation in cytogenetics laboratories.
9. Microbiology Sample Processing: Supports bacterial and yeast cell pelleting for culture and assay preparation.
10. Research and Academic Laboratories: Used in university and research laboratory settings for routine centrifugation needs.
11. Veterinary Diagnostic Laboratory: Supports sample processing for animal health testing and veterinary diagnostics.
12. Blood Processing for Platelet-Rich Plasma (PRP): Used for PRP preparation in regenerative medicine applications.
13. Clinical Pathology: Supports sample preparation for a wide range of clinical pathology tests including enzymes, electrolytes, and protein analysis.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A high-speed benchtop microcentrifuge with 24-place rotor capacity and multiple rotor options, designed for clinical diagnostic sample processing, molecular biology applications, and research laboratory use.
  • Designation: D3024 High Speed Micro Centrifuge, High Speed Microcentrifuge, Benchtop Microcentrifuge, Clinical Centrifuge, Molecular Biology Centrifuge, DLAB D3024.
  • Key Components:
o Rotor A24-2: 24 × 1.5/2.0 mL rotor with 0.5 mL and 0.2 mL tube adapters.
o Optional Rotors: 0.2 mL × 36, 0.5 mL × 36, 0.2 mL × 4 PCR strips, 5 mL × 12, 5 mL × 18 configurations.
o Motor: Brushless DC motor for quiet, durable operation.
o Display: LCD display for speed and time monitoring.
o Control: Touch panel for precise parameter adjustment.

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Maximum Speed: 15,000 rpm.
  • Maximum RCF (Relative Centrifugal Force): 21,380 × g.
  • Speed Setting Range: 500 – 15,000 rpm, step: 100 rpm.
  • Time Setting Range: 20 seconds – 99 minutes.
  • Capacity (Standard Rotor): 24 × 1.5/2.0 mL tubes.
  • Additional Rotor Capacities: 0.2 mL × 36, 0.5 mL × 36, PCR strips × 4, 5 mL × 12, 5 mL × 18.
  • Acceleration/Braking Time: 25 seconds up / 25 seconds down.
  • Motor Type: Brushless DC motor.
  • Noise Level: ≤ 55 dB.
  • Power Requirements: AC 100–240 V, 50/60 Hz.
  • Dimensions (L × W × H): 210 × 250 × 170 mm.
  • Weight: Approximately 4.5 kg.
  • Rotor Material: Engineering polymer and aluminum alloy construction for durability.

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: High-strength plastic housing with durable rotor assembly.
  • Control: LCD display with touch panel for speed and time adjustment.
  • Rotor Exchange: Tool-free rotor change system for quick switching between applications.
  • Operation Modes: Continuous operation mode; programmable for repeat tests.
  • Speed/RCF Switchover: Convenient switchover between speed and RCF display.
  • Sound Alert: Sound alert at run completion.
  • Portability: Benchtop footprint suitable for standard laboratory benchtops.
  • Maintenance: Brushless DC motor requires minimal maintenance.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: Class II medical device.
  • Safety Certification: CE certified; meets applicable regulatory standards.
  • Safety Features: Automatic imbalance detection, automatic lid lock, lid safety interlock, over-speed detection, over-temperature detection.
  • Overheat Protection: Built-in thermal protection mechanism.
  • Electrical Safety: Wide voltage compatibility (100-240V).
  • Noise Control: Low noise operation (≤55 dB) for comfortable laboratory environment.
  • Aerosol Protection: Bio-safe rotor design for aerosol containment.

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry benchtop; protect from dust and moisture.
  • Cleaning: Wipe exterior with soft, damp cloth; use mild detergent if needed.
  • Rotor Maintenance: Remove and clean rotors with mild detergent; dry thoroughly before reinstallation.
  • Inspection: Inspect rotors for cracks or damage before each use; replace if compromised.
  • Power Cord: Inspect power cord for damage before each use.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: High-throughput sample processing for blood chemistry, coagulation testing, PCR preparation, nucleic acid extraction, and protein analysis in clinical diagnostic and research laboratories.
  • Clinical Role: Essential sample preparation equipment in clinical diagnostic laboratories, hospital laboratories, molecular diagnostics labs, blood banks, pathology departments, and research laboratories.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Rotor Balancing: Ensure rotor is balanced with tubes of equal weight; imbalance will trigger automatic shutdown.
  • Lid Security: Ensure lid is securely closed before operation; automatic lid lock prevents operation with open lid.
  • Rotor Inspection: Inspect rotors for cracks or damage before each use; do not use damaged rotors.
  • Tube Compatibility: Use only tubes rated for centrifugation at high speeds (up to 21,380 × g).
  • Rotor Loading: Load tubes symmetrically; do not run rotor with empty positions unless using provided dummy tubes.
  • Cleaning: Clean spills immediately; disinfect if biological materials are involved.
  • Placement: Place on stable, level surface; ensure adequate ventilation.
  • Training: Only trained laboratory personnel should operate the centrifuge.

2. FIRST AID MEASURES

  • Tube Breakage: If tube breaks during operation, stop centrifuge immediately, allow rotor to stop fully, carefully remove fragments using forceps, disinfect rotor and chamber.
  • Sample Splash: If biological sample splashes, disinfect area immediately with appropriate disinfectant.
  • Imbalance Shutdown: If imbalance shutdown occurs, rebalance rotor equally, restart centrifuge.

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic components are combustible; electrical components present fire risk.
  • Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for electrical fires.
  • Fire Response: Unplug centrifuge immediately; do not use water on electrical fire.