Pro Thermo Control(H100)

WhatsApp Order
The Pro Thermo Control(H100) is a programmable digital dry bath heater (thermostatic control device) designed for precise temperature-controlled heating in clinical diagnostic, molecular biology, and research laboratories . Operating over a temperature range of 15°C to 100°C (room temperature +5°C to 100°C) with control accuracy of ±0.5°C, this compact benchtop unit provides uniform heating (temperature uniformity max. ±0.5°C) and a rapid heating rate of 5.5°C/min .
The H100-Pro features tool-free magnetic heat block mounting with magnet adhesion technology, allowing quick interchange of aluminum heating blocks compatible with various tube sizes (0.5 mL to 50 mL tubes, PCR plates, and microplates) . The TFT display provides real-time monitoring of temperature and time settings, with programmable memory supporting up to 9 programs (each with up to 6 sequential steps) for customizable thermal protocols . Built-in temperature calibration function (three-point calibration: 37°C, 60°C, 90°C) ensures long-term accuracy and compliance .
For the clinical laboratory scientist and molecular biologist, the H100-Pro supports enzyme-substrate reactions for biochemical tests and clinical chemistry, DNA denaturation for nucleic acid amplification and PCR preparation, sample preparation for molecular diagnostics and nucleic acid extraction, and reagent thawing for diagnostic workflows . Individual block lids minimize heat loss and prevent contamination, while the overheating protection (150°C safety cutoff) ensures safe sample and user handling .
For the patient undergoing diagnostic testing for infectious diseases, genetic disorders, or cancer biomarkers, the H100-Pro’s precise temperature control ensures consistent DNA denaturation, reliable enzyme reaction conditions, and accurate sample preparation—supporting reliable test results that guide appropriate treatment decisions across clinical chemistry, molecular diagnostics, and research applications.
Description

Pro Thermo Control(H100)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Precise Heating for Molecular Biology and Diagnostic Assays
  • Primary Use: Provides a programmable digital dry bath heater with a temperature range from 15°C to 100°C (ambient +5°C to 100°C), designed for precise temperature control of clinical and molecular biology samples .
  • How it helps: For the clinical laboratory scientist and molecular biologist, the H100-Pro delivers precise temperature control (accuracy ±0.5°C) across its entire range, ensuring optimal conditions for enzyme reactions, DNA denaturation, and sample incubation (room temp +5 to 100°C) . The ambient temperature and humidity must be 10-40°C and <80% RH for proper operation.
2. Enzyme Reaction and Biochemical Test Preparation
  • Primary Use: Used for incubating enzyme-substrate reactions, biochemical assays, and clinical chemistry tests requiring stable, uniform heating .
  • How it helps: For the clinical chemist, the H100-Pro supports enzymatic assay preparation for liver function tests (ALT, AST), cardiac biomarkers, and other enzyme-based diagnostic assays . Consistent temperature uniformity (max. ±0.5°C) ensures reliable enzymatic assay results, improving diagnostic accuracy and reducing inter-run variability .
3. DNA Denaturation and Nucleic Acid Amplification
  • Primary Use: Provides controlled heating for DNA denaturation steps in PCR preparation, nucleic acid amplification protocols, and molecular diagnostic workflows .
  • How it helps: For the molecular biologist, the H100-Pro’s rapid heating rate (5.5°C/min) and precise temperature control (±0.5°C) ensures consistent denaturation of double-stranded DNA—critical for PCR, sequencing, and hybridization-based assays . This supports accurate genetic testing for infectious diseases, inherited disorders, and oncology biomarkers.
4. Sample Preparation and Reagent Thawing
  • Primary Use: Used for controlled thawing of frozen clinical specimens and gentle warming of reagents to operating temperature before diagnostic testing .
  • How it helps: For the medical technologist, the H100-Pro provides uniform, gentle heating that preserves sample integrity—preventing hemolysis, protein denaturation, and analyte degradation that can occur with rapid or uneven heating. For the patient, proper sample handling reduces the need for repeat specimen collection due to degraded samples, saving time and discomfort.

SECONDARY & SUPPORTIVE USES

1. Lipid and Cholesterol Analysis Sample Preparation: Used for warming samples and reagents in lipid profiling and cholesterol fractionation protocols.
2. Immunoassay and ELISA Incubation: Provides precise temperature control for enzyme-linked immunosorbent assay (ELISA) incubation steps .
3. Protein Denaturation and Purification: Used for protein denaturation steps in Western blotting and protein purification workflows.
4. Nucleic Acid Extraction and Purification: Supports spin column-based DNA/RNA extraction protocols requiring precise temperature control .
5. Solid Phase Extraction (SPE) Applications: Used for temperature-controlled elution and incubation steps in SPE procedures .
6. Oligonucleotide Synthesis and Deprotection: Supports deprotection steps in oligonucleotide synthesis workflows .
7. Histology and Pathology Tissue Processing: Used for warming embedding media and processing solutions in histology laboratories.
8. Microbiology Culture Media Preparation: Warms culture media to specified temperatures before inoculation in clinical microbiology workflows.
9. Serum Coagulation Testing: Supports plasma/serum preparation for coagulation studies and clotting factor analysis .
10. Therapeutic Drug Monitoring: Used for warming samples and reagents in therapeutic drug monitoring and toxicology screening.
11. Endocrine and Hormone Assay Preparation: Supports temperature-controlled incubation for thyroid function tests, reproductive hormone panels, and endocrine assays .
12. Pharmaceutical Quality Control: Used for stability testing and sample preparation in pharmaceutical QC laboratories.
13.Blood Bank and Transfusion Medicine: Supports temperature-controlled processing of blood components and compatibility testing samples.
14. Research and Academic Laboratories: Provides reliable programmable heating for general laboratory incubation needs in research settings.
15. Veterinary Diagnostic Laboratory: Supports clinical chemistry and molecular biology workflows for animal health testing .
16. Food Safety and Environmental Testing: Used for sample preparation and media warming in food microbiology and water quality testing.
17. Programmable Multi-Step Protocols: Customizable user program setting with up to 6 sequential steps for complex thermal protocols .
18. Temperature Calibration Support: Built-in temperature calibration function for long-term accuracy and compliance .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A programmable digital dry bath heater (thermostatic control device) with magnetic or mechanical heat block mounting, designed for precise temperature control in clinical diagnostics, molecular biology, and research laboratories .
  • Designation: H100-Pro Thermo Control, Dry Bath Heater, Digital Dry Bath, Programmable Heating Block, DLAB H100-Pro, Thermostatic Incubator .
  • Key Components:
    • Heating Block: Interchangeable aluminum blocks compatible with various tube sizes (0.5 mL, 1.5 mL, 2 mL, 5 mL, 15 mL, 50 mL, PCR plates, microplates) .
    • Magnetic Mounting System: Magnetic heat block fixation for tool-free, quick interchange of blocks with magnet adhesion technology .
    • TFT Display: Full-color TFT screen for real-time monitoring of temperature and time settings .
    • Control Interface: User-friendly interface with programmable memory (9 programs) .
    • Block Lids: Individual block lids for heat preservation and contamination prevention .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Temperature Range (Heating): Room temperature +5°C to 100°C .
  • Temperature Setting Range: 15°C to 100°C .
  • Temperature Control Accuracy: ±0.5°C (temperature control@20-45) .
  • Temperature Uniformity: ±0.2°C to ±0.5°C (max. ±0.5°C) .
  • Maximum Heating Rate: 5.5°C/min .
  • Time Setting Range: 0 to 99 hours 59 minutes (0min-99h59min) .
  • Program Memory: 9 program slots; supports up to 6 sequential steps per program .
  • Power: 200W .
  • Voltage/Frequency: 100–240V, 50/60Hz (DC12V input) .
  • Display: TFT (full-color) .
  • Overheating Protection: 150°C safety cutoff .
  • Module Material: Aluminum (adapter block material) .
  • Dimensions (W × D × H): 200 × 235 × 120 mm .
  • Weight: 7.3 kg .
  • Ambient Temperature: 10-40°C .
  • Permissible Ambient Humidity: <80% RH .
  • Calibration: Built-in temperature calibration function; three-point calibration (37°C, 60°C, 90°C) .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Compact benchtop housing (200 × 235 × 120 mm) with durable aluminum heating blocks.
  • Mounting System: Magnetic block mounting (tool-free) with magnet adhesion technology for quick interchangeable blocks .
  • Control System: Microprocessor-controlled with programmable memory (9 programs) and TFT display for real-time monitoring .
  • Programmability: Customizable program setting with up to 6 sequential steps per program .
  • Operation Modes: Timing mode and continuous operation mode .
  • Additional Functions: USB interface for data export ; temperature calibration function (built-in) .
  • Block Lids: Individual block lids for heat preservation, preventing contamination and minimizing heat loss .
  • Safety Features: Overheating protection (150°C safety cutoff) , over-temperature protection.
  • Portability: Benchtop design with compact footprint suitable for routine laboratory use.
  • Maintenance: Magnetic block system allows easy cleaning and disinfecting without tools .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: Medical device for clinical diagnostic use; laboratory equipment classification.
  • Safety Features: Overheating protection system (150°C safety cut-off) , over-temperature protection, over-current protection, reverse voltage protection .
  • Electrical Safety: Universal voltage (110/220V, 50/60Hz) with DC12V input; 200W power consumption .
  • GLP Compliance: Programmable protocols support GLP documentation; USB connectivity for data export .
  • Temperature Calibration: Built-in three-point temperature calibration ensures long-term accuracy and compliance .
  • Unit Weight: 7.3 kg for benchtop stability.

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry benchtop; ambient temperature 10-40°C, relative humidity <80% RH .
  • Cleaning: Wipe exterior with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; magnetic block system allows tool-free removal for easy cleaning and disinfecting .
  • Block Maintenance: Remove and clean aluminum heating blocks with mild detergent; dry thoroughly before reinstallation.
  • Inspection: Inspect block contacts for residue or damage before each use; clean if needed.
  • Calibration: Perform periodic temperature calibration per manufacturer guidelines (three-point calibration: 37°C, 60°C, 90°C) whenever heating block is changed .
  • Power Cord: Inspect power cord for damage before each use.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Precise heating for molecular biology applications (DNA denaturation, PCR preparation), clinical chemistry (enzyme/substrate reactions, biochemical tests), diagnostic workflows (clinical diagnostics), and general sample preparation (reagent warming, nucleic acid extraction) .
  • Clinical Role: Essential sample preparation and incubation equipment in clinical diagnostic laboratories, hospital molecular diagnostics labs, blood banks, pathology departments, research laboratories, and pharmaceutical QC facilities requiring precise programmable heating.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Operating Conditions: Use within permissible ambient temperature (10-40°C) and humidity (<80% RH) .
  • Heating Block Compatibility: Use only manufacturer-approved aluminum heating blocks for specific tube formats to ensure proper thermal contact and heat transfer.
  • Block Installation: Ensure heating block is properly seated with magnetic mounting system (tool-free, must be securely attached) before operation.
  • Temperature Verification: Allow unit to reach set temperature before loading temperature-sensitive samples; verify temperature stability before use.
  • Lid Use: Always use block lids during operation to maintain temperature stability, prevent heat loss, and prevent contamination .
  • Sample Containers: Use appropriate containers rated for the temperature range (15-100°C) to prevent leakage or material degradation.
  • Overheating Protection: Unit includes 150°C safety cutoff; however, do not exceed recommended temperature settings for specific sample types .
  • Cleaning: Clean spills immediately; disinfect heating block if biological materials are involved; allow block to cool before removal.
  • Placement: Place on firm, flat, level, heat-resistant surface; ensure adequate clearance around unit for ventilation.
  • Training: Only trained laboratory personnel should operate the H100-Pro for clinical diagnostic applications.

2. FIRST AID MEASURES

  • Burn/Scald: If hot heating block contacts skin, cool affected area immediately with cool running water for at least 15 minutes; seek medical attention for severe burns.
  • Sample Spillage: If biological sample spills into unit, disconnect power, allow to cool, disinfect area immediately with 70% ethanol or appropriate disinfectant.
  • Electrical Malfunction: If unit shows signs of electrical malfunction, disconnect power immediately; do not attempt to operate; contact service personnel.
  • Calibration Verification: If test results are inconsistent, perform temperature calibration to verify accuracy before proceeding with diagnostic testing .

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn.
  • Extinguishing Media: Use carbon dioxide or dry chemical extinguisher for electrical fires.
  • Fire Response: Unplug unit immediately; do not use water on electrical fire.