Intelligent 3D Shaker (SK-D1810-S)

WhatsApp Order
The Intelligent 3D Shaker (SK-D1810-S) featuring fixed 10° tilt angle, variable speed control (10-80 rpm), dual independent LED displays, programmable timer (1 minute to 99 hours 59 minutes), and a maintenance-free brushless DC motor, designed for gentle, uniform mixing of cell cultures, molecular biology samples, and diagnostic assays in clinical and research laboratories.
Key features include a 3-dimensional rocking motion at fixed 10° tilt angle for gentle, uniform mixing, dual independent LED displays for simultaneous monitoring of speed and time, programmable timer with automatic stop (1 minute to 99 hours 59 minutes), and a non-slip silicone work platform (268 × 268 mm) that securely holds flasks, culture flasks, petri dishes, centrifuge tubes, and blotting containers.
The Intelligent 3D Shaker (SK-D1810-S) accommodates a variety of laboratory vessels, with a maximum load capacity of 3 kg and universal voltage (100-240V, 50/60Hz) enabling use in laboratories worldwide without voltage conversion. The cold room and incubator compatibility (5-40°C operating temperature, 80% RH) allows sample mixing under controlled temperature conditions for temperature-sensitive applications. The IP21 protection rating provides durability against dust and moisture in typical laboratory environments.
For the clinical laboratory scientist and molecular biologist, the Intelligent 3D Shaker (SK-D1810-S) supports cell culture maintenance (uniform distribution of cells, nutrients, and reagents), DNA/RNA extraction protocols, Western blotting and antibody incubations (consistent reagent distribution across membranes), gel staining and destaining (automated, reproducible dye distribution), hybridization reactions for nucleic acid research, and immunoassays (ELISA plate incubation, reducing well-to-well variability).
Universal voltage (100-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion, while the compact footprint (294 × 348 × 123 mm) and moderate weight (3.7 kg) allow easy benchtop placement. The whisper-quiet brushless DC motor and wear-resistant silicone platform ensure minimal noise, extended service life, and easy cleaning.
For the patient undergoing diagnostic testing for infectious diseases, genetic disorders, or cancer biomarkers, the SK-D1810-S’s gentle, uniform mixing ensures consistent cell culture conditions, reliable DNA extraction, reproducible antibody incubations, and accurate gel electrophoresis results—supporting reliable diagnostic outcomes that guide appropriate treatment decisions across molecular diagnostics, immunology, and cell biology applications.
Description

 Intelligent 3D Shaker (SK-D1810-S)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. Gentle 3D Mixing for Cell Culture and Molecular Biology
  • Primary Use: Provides a digital 3D shaker with fixed 10° tilt angle, variable speed control (10-80 rpm), and independent LED displays for time and speed, designed for gentle, uniform mixing of cell cultures, DNA extractions, and molecular biology samples.
  • How it helps: For the cell biologist and molecular biologist, the Intelligent 3D Shaker (SK-D1810-S) gentle three-dimensional rocking motion ensures uniform distribution of cells, nutrients, and reagents without causing shear stress or damage to delicate biological samples—critical for successful cell culture maintenance, DNA extraction protocols, and antibody incubations. For the patient undergoing diagnostic testing, consistent sample processing ensures that molecular assays (PCR, Western blot) produce accurate, reproducible results that guide appropriate treatment decisions.
2. Antibody Incubations and Immunoblotting
  • Primary Use: Used for uniform mixing in Western blotting, immunoassays, and antibody incubation protocols, ensuring consistent reagent distribution across membranes and gels.
  • How it helps: For the immunology technologist and research scientist, the 3D rocking motion (fixed 10° tilt angle) ensures complete coverage of blotting membranes with antibodies and blocking solutions—reducing background noise and improving signal-to-noise ratio in diagnostic immunoblots. For the patient undergoing confirmatory testing for infectious diseases (HIV, Lyme disease) or autoimmune conditions, consistent antibody incubations ensure accurate detection of disease-specific antibodies that guide diagnosis and treatment monitoring.
3. DNA Extraction and Gel Staining Applications
  • Primary Use: Supports uniform mixing for DNA extraction protocols, gel staining, and destaining of electrophoresis gels, ensuring consistent reagent distribution and reproducible results.
  • How it helps: For the molecular biologist and clinical laboratory scientist, the Intelligent 3D Shaker (SK-D1810-S) programmable timer (1 minute to 99 hours 59 minutes) allows automated, reproducible dye distribution for gel staining and destaining—reducing operator-dependent variability and improving band visualization. For the patient undergoing genetic testing, consistent nucleic acid extraction and gel electrophoresis results support accurate diagnosis of genetic disorders, infectious diseases, and oncology biomarkers.
4. Cold Room and Incubator Compatibility
  • Primary Use: Designed for use in cold rooms (5-40°C, 80% RH) and incubators, allowing sample mixing under controlled temperature conditions for temperature-sensitive applications.
  • How it helps: For the clinical laboratory scientist and research technician, the Intelligent 3D Shaker (SK-D1810-S) wide operating temperature range (5-40°C) and IP21 protection rating allow sample mixing in cold rooms for temperature-sensitive antibody binding reactions, as well as in incubators for cell culture and microbiology workflows. For the patient, temperature-controlled mixing preserves sample integrity for temperature-sensitive assays, supporting accurate diagnostic results for conditions requiring strict temperature control during sample processing.

SECONDARY & SUPPORTIVE USES

1. Hybridization Reactions and Nucleic Acid Research: Used for uniform mixing in hybridization protocols for DNA and RNA studies, including Southern and Northern blotting applications.
2. Cell Culture Maintenance: Supports gentle, continuous mixing for cell culture flasks and culture bottles, ensuring uniform distribution of nutrients and gases for optimal cell growth.
3. Immunoprecipitation and Protein Extraction: Used for gentle mixing in immunoprecipitation protocols and protein extraction workflows requiring consistent, gentle agitation.
4. ELISA Plate Incubation: Supports uniform mixing during ELISA plate incubation steps, reducing well-to-well variability in diagnostic immunoassays.
5. Microbial Culture Growth: Used for mixing bacterial and yeast cultures in flasks and culture bottles, ensuring uniform growth conditions and consistent cell density.
6. Gel Destaining Protocols: Used for destaining of Coomassie blue-stained SDS-PAGE gels and other electrophoresis applications requiring gentle, uniform agitation.
7. Blotting Membrane Washing: Supports uniform washing of Western blot and Southern blot membranes, reducing background noise and improving signal specificity.
8. Liquid-Solid Suspension Homogenization: Used for mixing of cell pellets, tissue homogenates, and other liquid-solid suspensions in molecular preparation workflows.
9. Clinical Sample Preparation: Supports mixing of serum, plasma, and other biological fluids for clinical chemistry and immunoassay sample preparation.
10. Research and Academic Laboratories: Provides versatile 3D mixing for diverse research applications in cell biology, molecular biology, and biochemistry.
11. Pharmaceutical Quality Control: Used for mixing of QC samples and reagents in pharmaceutical testing laboratories requiring gentle, uniform agitation.
12. Veterinary Diagnostic Laboratory: Supports mixing of biological specimens for animal health testing and infectious disease diagnosis.
13. Chromogenic Substrate Development: Used in ELISA and immunohistochemistry workflows for consistent chromogenic substrate development across multiple samples.
14. Microplate Assay Development: Supports uniform mixing in 96-well and 384-well microplate assays for drug discovery and biomarker screening.
15. University and Educational Laboratory Training: Provides versatile 3D mixing for teaching laboratory techniques in undergraduate and graduate science courses.
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A digital 3D shaker (intelligent shaker) with fixed 10° tilt angle, variable speed control (10-80 rpm), dual LED display, and programmable timer, designed for gentle, uniform mixing of cell cultures, molecular biology samples, and diagnostic assays in clinical and research laboratories.
  • Designation: SK-D1810-S Intelligent 3D Shaker, 3D Shaker, Laboratory Shaker, Digital Rocking Shaker, DLAB SK-D1810-S, Intelligent 3D Rocker.
  • Key Components:
o Motion Type: 3-dimensional rocking (nutating) motion at fixed 10° tilt angle.
o Work Platform: Anti-slip silicone disc surface (268 × 268 mm) for secure vessel placement.
o Display: Dual independent LED displays for simultaneous speed and timer viewing.
o Control: Variable speed control knob/touchpad; programmable timer.
o Motor: Maintenance-free brushless DC motor.
o Housing: Impact-resistant plastic body with non-slip base.

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Motion Type: 3D (three-dimensional) rocking motion.
  • Tilt Angle: Fixed 10°.
  • Speed Range: 10-80 rpm (variable, adjustable).
  • Speed Display: LED digital display.
  • Timer Display: LED digital display.
  • Timer Range: 1 minute to 99 hours 59 minutes (programmable).
  • Maximum Load Capacity: 3 kg (approx. 6.6 lbs).
  • Work Platform Dimensions (W × D): 268 × 268 mm.
  • External Dimensions (W × D × H): 294 × 348 × 123 mm.
  • Motor Type: Brushless DC motor.
  • Motor Rating Input: 16W.
  • Motor Rating Output: 10W.
  • Total Power: 20W.
  • Voltage/Frequency: 100-240V, 50/60Hz (universal voltage).
  • Weight: 3.7 kg (approx. 8.2 lbs).
  • Operating Temperature: 5-40°C (cold room and incubator compatible).
  • Permissible Ambient Humidity: ≤80% RH.
  • Protection Class: IP21.
  • Compatibility: Suitable for flasks, culture flasks, petri dishes, centrifuge tubes, microplates, and blotting containers.

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Impact-resistant plastic body with non-slip base for stable benchtop placement.
  • Work Platform: Anti-slip silicone disc surface (268 × 268 mm) provides secure vessel placement, preventing containers from sliding during operation.
  • Motion Type: 3-dimensional rocking motion at fixed 10° tilt angle for gentle, uniform mixing.
  • Display: Dual independent LED displays show real-time speed (10-80 rpm) and timer (1 minute to 99 hours 59 minutes) simultaneously, allowing easy monitoring.
  • Control System: Variable speed control knob/touchpad for simple adjustment; programmable timer with automatic stop at end of set time.
  • Timer: Programmable timer range 1 minute to 99 hours 59 minutes; ideal for extended experiments; unit automatically halts when timer reaches zero.
  • Noise Level: Quiet operation (brushless DC motor) minimizes distractions in clinical laboratory environment.
  • Operating Conditions: Can be used in cold rooms (5-40°C) and incubators (5-40°C, 80% RH).
  • Portability: Compact footprint (294 × 348 × 123 mm) and moderate weight (3.7 kg) for easy benchtop placement.
  • Maintenance: Brushless DC motor eliminates routine brush replacement; anti-slip silicone surface is easy to clean.

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards.
  • Safety Features: Non-slip silicone platform prevents vessel movement; IP21 protection rating provides protection against solid objects >12mm and vertical dripping water.
  • Electrical Safety: Universal voltage (100-240V, 50/60Hz) for international use; 20W low power consumption; earthed power connection recommended.
  • Motor Type: Brushless DC motor provides maintenance-free, quiet, stable operation.
  • Timer Safety: Programmable timer (1 minute to 99 hours 59 minutes) with automatic stop at end of set time prevents over-mixing of sensitive samples.
  • Operating Conditions: 5-40°C ambient temperature; ≤80% relative humidity.

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture.
  • Cleaning: Wipe work platform and housing with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; disconnect power before cleaning.
  • Inspection: Inspect power cord for damage before each use; check work platform for residue or wear; verify stability of benchtop placement.
  • Operation: Place unit on safe, stable surface; ensure operating voltage matches power supply; socket must be earthed reliably; connect power cable; switch ON instrument.
  • Speed Setting: Rotate speed control knob to set desired speed (10-80 rpm); LED display shows current speed setting.
  • Timer Setting: Use timer controls to set desired run time (1 minute to 99 hours 59 minutes); LED display shows current time setting; unit automatically halts when timer reaches zero.
  • Load Balancing: Distribute vessels evenly across work platform; do not exceed maximum load capacity (3 kg).
  • Spill Management: If liquid spills onto unit, disconnect power immediately, clean thoroughly, allow to dry before reuse; anti-slip silicone surface facilitates spill management.
  • Maintenance: If service required, instrument must be cleaned in advance to avoid pollution of hazardous substances.

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Gentle, uniform 3D mixing for cell culture maintenance, DNA/RNA extraction, Western blotting, immunoassays, gel staining/destaining, and hybridization reactions in clinical diagnostic, molecular biology, and research laboratories.
  • Clinical Role: Essential mixing equipment in clinical diagnostic laboratories, molecular biology labs, immunology laboratories, cell culture facilities, pharmaceutical research laboratories, and academic research institutions.
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Read operating instructions before use; ensure only trained staff works with instrument; ensure socket is earthed reliably; disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources.
  • Load Limits: Do not exceed maximum load capacity (3 kg); ensure load is evenly distributed across work platform to prevent imbalance.
  • Spill Protection: Use appropriate vessel caps or seals to prevent sample leakage; clean spills immediately; anti-slip silicone surface facilitates spill management.
  • Speed Selection: Select appropriate speed for sample type (10-80 rpm); use lower speeds (10-30 rpm) for delicate cell cultures and antibody incubations; use higher speeds (50-80 rpm) for gel staining/destaining solutions.
  • Cold Room/Incubator Use: Ensure instrument is placed on stable surface within cold room or incubator; operating temperature range 5-40°C; permissible ambient humidity ≤80% RH.
  • Timer Use: Set appropriate time for mixing protocol; do not exceed recommended mixing times for sensitive samples; unit automatically halts when timer reaches zero.
  • Platform Cleaning: Clean anti-slip silicone surface regularly to prevent residue buildup and maintain anti-slip properties.
  • Training: Only trained laboratory personnel should operate the SK-D1810-S for clinical diagnostic applications.

2. FIRST AID MEASURES

  • Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water.
  • Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel.
  • Mechanical Failure: If unit fails to operate or makes abnormal noise, disconnect power, check for obstruction, contact service if issue persists.
  • Chemical Spill: If corrosive chemicals spill on unit, disconnect power immediately, wipe with appropriate neutralizer, dry thoroughly before reconnecting power.

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn.
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires.
  • Fire Response: Unplug unit immediately; do not use water on electrical fire.