Pro Large Multifunctional Transference Rocking Shaker (SK-R330-)

WhatsApp Order
The Pro Large Multifunctional Transference Rocking Shaker is a high-capacity digital see-saw rocking shaker featuring fixed 9° tilt angle, variable speed control (10-70 rpm), dual independent LCD displays, programmable timer (1-1199 minutes), and a maintenance-free brushless DC motor, designed for uniform mixing of electrophoresis gels, Western blot membranes, and biological samples in high-volume clinical diagnostic and research laboratories .
Key features include see-saw rocking motion at fixed 9° tilt angle for gentle, thorough mixing, dual independent LCD displays for simultaneous monitoring of speed and time, programmable timer with automatic stop (1-1199 minutes) and audible alert, continuous or timed operation modes, and a maintenance-free brushless DC motor for quiet, reliable operation . The 300 × 285 mm work platform with 10 kg load capacity securely holds multiple culture dishes, flasks, beakers, blotting containers, and gel staining trays via optional accessories  .
The Pro Large Multifunctional Transference Rocking Shaker  accommodates a variety of laboratory vessels, with universal voltage (100-240V, 50/60Hz) enabling use in laboratories worldwide without voltage conversion . The cold room and incubator compatibility (5-40°C operating temperature, 80% RH) allows sample mixing under controlled temperature conditions for temperature-sensitive applications such as hybridizations and cell culture . The IP21 protection rating provides durability against dust and moisture in typical laboratory environments  .
For the clinical laboratory scientist and molecular biologist, the Pro Large Multifunctional Transference Rocking supports high-throughput electrophoresis gel decolorization and staining (Coomassie blue, silver nitrate), Western blot membrane washing and antibody incubations across multiple membranes, Southern and Northern blot hybridization reactions, immunoprecipitation (IP) protocols, liquid-solid suspension mixing (cell pellets, tissue homogenates), clinical sample preparation, and general liquid mixing for aeration and extraction applications  .
Universal voltage (100-240V, 50/60Hz) enables use in laboratories worldwide without voltage conversion, while the robust weight (9 kg) provides benchtop stability and efficient space utilization  . The whisper-quiet brushless DC motor ensures minimal noise, extended service life, and enhanced laboratory safety  .
For the patient undergoing diagnostic testing for infectious diseases, genetic disorders, or cancer biomarkers, the  Pro Large Multifunctional Transference Rocking Shaker  uniform see-saw rocking mixing across large sample batches ensures consistent gel staining, reproducible antibody incubations, and accurate nucleic acid hybridization results supporting reliable diagnostic outcomes that guide appropriate treatment decisions across high-volume molecular diagnostics, immunology, and cell biology applications.
Description

Pro Large Multifunctional Transference Rocking Shaker (SK-R330-)

PRIMARY CLINICAL & DIAGNOSTIC USES

1. High-Capacity Western Blot Membrane Processing
  • Primary Use: Provides a large-scale digital see-saw rocking shaker with a fixed 9° tilt angle, variable speed control (10-70 rpm), and dual independent LCD displays, specifically designed for uniform washing of Western blot membranes and antibody incubations across large sample volumes .
  • How it helps: For the immunology technologist and clinical laboratory scientist, the Pro Large Multifunctional Transference Rocking Shaker gentle rocking motion ensures complete, even coverage of blocking buffers and antibody solutions across multiple large membranes simultaneously—effectively reducing background noise and enhancing signal specificity in diagnostic immunoblots . For the patient undergoing confirmatory testing for HIV, Lyme disease, or autoimmune conditions, consistent membrane processing across large batches ensures accurate detection of disease-specific antibodies that guide diagnosis and treatment monitoring.
2. High-Throughput Gel Staining and Destaining for Molecular Diagnostics
  • Primary Use: Engineered for uniform distribution of Coomassie blue, silver nitrate, and other staining solutions onto polyacrylamide and agarose gels, ensuring consistent background clearance and band visualization for diagnostic protein analysis .
  • How it helps: For the molecular biologist and clinical laboratory scientist, the Pro Large Multifunctional Transference Rocking Shaker see-saw rocking action (9° fixed angle) and 10 kg load capacity allow simultaneous processing of multiple large gels—reducing operator-dependent variability and improving band resolution . For the patient undergoing genetic testing for hereditary disorders or protein abnormalities, clear and consistent gel results support accurate diagnosis without the need for repeat testing.
3. DNA Hybridization and Molecular Biology Applications
  • Primary Use: Supports uniform mixing for Southern blot, Northern blot, and in-situ hybridization protocols, as well as DNA renaturation processes, with cold room and incubator compatibility .
  • How it helps: For the molecular geneticist, the SK-R330-Pro’s wide operating temperature range (5-40°C) allows use inside standard incubators or cold rooms for stringent temperature control during nucleic acid hybridization—improving binding specificity and reducing false positives . For the patient undergoing genetic cancer screening or hereditary disease testing, consistent hybridization conditions ensure high-fidelity, reliable results.
4. Large-Capacity Clinical Sample Preparation
  • Primary Use: Designed for mixing liquid samples in culture dishes, flasks, and beakers, supporting aeration and extraction applications in high-volume clinical diagnostic workflows .
  • How it helps: For the clinical laboratory scientist, the 10 kg load capacity and wide speed range (10-70 rpm) allow versatile, high-volume sample processing—from gentle mixing of patient serum samples to more vigorous extraction procedures . For the patient, reliable sample preparation across large batches ensures that diagnostic test results accurately reflect the clinical specimen, reducing the risk of false results due to heterogeneous sample distribution.
5. Cold Room and Incubator Compatibility
  • Primary Use: Designed for use in cold rooms (5-40°C, 80% RH) and incubators, allowing sample mixing under controlled temperature conditions for temperature-sensitive applications .
  • How it helps: For the clinical laboratory scientist and research technician, the SK-R330-Pro’s wide operating temperature range (5-40°C) allows sample mixing in cold rooms for temperature-sensitive antibody binding reactions, as well as in incubators for cell culture and microbiology workflows across large sample volumes . For the patient, temperature-controlled mixing preserves sample integrity for temperature-sensitive assays, supporting accurate diagnostic results for conditions requiring strict temperature control during sample processing.

SECONDARY & SUPPORTIVE USES

1. Immunoprecipitation (IP) and Protein Extraction: Provides the gentle but consistent rocking motion required for capturing antigen-antibody complexes in solution for downstream analysis .
2. Cell Culture and Aeration: Provides continuous see-saw agitation for microbial, yeast, or mammalian cell cultures in flasks, ensuring adequate gas exchange and nutrient distribution .
3. Liquid-Solid Suspension Mixing: Effectively resuspends cell pellets, bacterial pellets, and homogenized tissue samples in buffers for DNA/RNA extraction workflows .
4. Clinical Chemistry Sample Preparation: Mixes serum, plasma, or urine samples on a benchtop shaker before analysis on automated analyzers .
5. ELISA Plate Incubation: Supports uniform mixing during ELISA plate incubation steps, reducing well-to-well variability in diagnostic immunoassays .
6. Microbiology Culture Mixing: Used for mixing bacterial and yeast cultures in flasks, ensuring uniform growth conditions and consistent cell density across batches .
7. Blotting Membrane Washing: Supports uniform washing of Western, Southern, and Northern blot membranes across multiple containers, reducing background noise and improving signal specificity .
8. Pharmaceutical Quality Control: Agitates QC samples for dissolution testing or stability studies in pharmaceutical R&D and QC laboratories .
9. Blood Bank and Transfusion Medicine: Supports gentle mixing of blood components, donor blood samples, and reagent red blood cells for compatibility testing .
10. Veterinary Diagnostic Laboratory: Supports mixing of biological specimens for animal health testing and infectious disease diagnosis in high-volume settings .
11. Research and Academic Laboratories: Provides large-capacity see-saw rocking mixing for diverse research applications in cell biology, molecular biology, and biochemistry .
12. Environmental and Food Testing Laboratories: Used for mixing of environmental extracts and food samples for microbiological and chemical analysis across multiple samples .
13. High-Volume Electrophoresis Gel Staining: Distributes Coomassie blue, silver, and fluorescent stains evenly for consistent protein and nucleic acid detection across large gels .
14. Fermentation and Bioprocessing: Provides consistent agitation for microbial or yeast cultures in flasks during small-scale fermentation and bioprocessing workflows .
15. University and Educational Laboratory Training: Provides reliable see-saw rocking mixing for teaching laboratory techniques in undergraduate and graduate science courses .
KEY PRODUCT FEATURES

1. BASIC IDENTIFICATION ATTRIBUTES

  • Device Type: A large multifunctional digital see-saw rocking shaker with dual independent LCD displays, variable speed control (10-70 rpm), programmable timer (1-1199 minutes), and maintenance-free brushless DC motor, designed for uniform mixing of electrophoresis gels, blotting membranes, and biological samples in high-volume clinical diagnostic and research laboratories .
  • Designation: SK-R330-Pro Large Multifunctional Transference Rocking Shaker, See-Saw Rocker, Digital Rocking Shaker, Large Multifunctional Rocking Shaker, DLAB SK-R330-Pro .
  • Key Components:
    • Motion Type: See-saw rocking motion at fixed 9° tilt angle .
    • Work Platform: 300 × 285 mm loading platform with anti-slip mat .
    • Motor: Maintenance-free brushless DC motor .
    • Display: Dual independent LCD displays for simultaneous speed and timer viewing .
    • Control: Digital control with programmable timer; continuous or timed operation mode .
    • Timer: 1-1199 minutes (1 minute to 19 hours 59 minutes) .
    • Housing: Impact-resistant, sturdy construction with non-slip base .
    • Optional Accessories: Wide range of platforms for culture flasks, petri dishes, and various vessels .
    • Power Supply: Universal voltage (100-240V, 50/60Hz) .

2. TECHNICAL & PERFORMANCE PROPERTIES

  • Tilt Angle: 9° (fixed) .
  • Speed Range: 10-70 rpm (variable, adjustable) .
  • Maximum Load Capacity: 10 kg (including platform) .
  • Operating Modes: Continuous operation or timed operation .
  • Timer Range: 1 minute to 19 hours 59 minutes (1-1199 minutes) .
  • Timer Display: LCD digital display .
  • Speed Display: LCD digital display .
  • Motor Type: DC motor (brushless) .
  • Motor Rating Input: 40W .
  • Motor Rating Output: 24W .
  • Total Power: 50W .
  • Voltage/Frequency: 100-240V, 50/60Hz (universal voltage) .
  • Work Platform Dimensions (W × D): 300 × 285 mm .
  • External Dimensions (W × D × H): 360 × 410 × 200 mm .
  • Weight: 9 kg .
  • Operating Temperature: 5-40°C (cold room and incubator compatible) .
  • Permissible Ambient Humidity: ≤80% RH .
  • Protection Class: IP21 .
  • Compatibility: Suitable for culture dishes, flasks, beakers, blotting containers, and gel staining trays via optional accessories .
  • Certifications: CE, cTUVus approved .

3. PHYSICAL & OPERATIONAL PROPERTIES

  • Construction: Impact-resistant, sturdy housing with non-slip base for stable benchtop placement; designed for heavy loads up to 10 kg .
  • Motion Type: See-saw rocking motion at fixed 9° tilt angle for gentle, uniform mixing .
  • Work Platform: 300 × 285 mm loading platform with anti-slip mat securely holds multiple vessels simultaneously; supports optional accessories for various vessel types .
  • Display: Dual independent LCD displays show real-time speed (10-70 rpm) and timer (1-1199 minutes) simultaneously .
  • Control System: Digital speed control; programmable timer with automatic stop at end of set time; continuous or timer operation mode optional .
  • Noise Level: Quiet operation (brushless DC motor) minimizes distractions in clinical laboratory environment .
  • Operating Conditions: Can be used in cold rooms (5-40°C) and standard incubators; IP21 protection rating .
  • Portability: Moderate weight (9 kg) for benchtop stability; footprint (360 × 410 × 200 mm) for efficient bench space utilization .
  • Maintenance: Brushless DC motor eliminates routine brush replacement .
  • Safety Features: Overload protection; non-slip base prevents movement during operation .

4. SAFETY & COMPLIANCE ATTRIBUTES

  • Regulatory Status: General laboratory equipment for in vitro diagnostic use; meets applicable laboratory safety standards .
  • Safety Features: IP21 protection rating provides protection against solid objects >12mm and vertical dripping water; non-slip base prevents movement during operation; overload protection .
  • Electrical Safety: Universal voltage (100-240V, 50/60Hz) for international use; 50W low power consumption; earthed power connection recommended .
  • Motor Type: Brushless DC motor provides maintenance-free, quiet, stable operation .
  • Timer Safety: Programmable timer (1-1199 minutes) with automatic stop prevents over-mixing of sensitive samples; audible alert when run completes .
  • Operating Conditions: 5-40°C ambient temperature; ≤80% relative humidity .
  • Certifications: CE, cTUVus approved .

5. STORAGE & HANDLING ATTRIBUTES

  • Storage: Store on clean, dry, level benchtop; protect from dust and moisture.
  • Cleaning: Wipe work platform and housing with soft, damp cloth using neutral detergent; 70% ethanol solution may be used for surface sterilization; disconnect power before cleaning .
  • Inspection: Inspect power cord for damage before each use; check work platform for residue or wear; verify stability of benchtop placement .
  • Operation: Place unit on safe, stable surface; adjust foot screws to ensure level operation; ensure operating voltage matches power supply; connect power cable; switch ON instrument .
  • Speed Setting: Set desired speed (10-70 rpm) using digital controls; LCD display shows current speed setting; speed can be altered during running .
  • Timer Setting: Set desired run time (1-1199 minutes) using digital controls; LCD display shows current time setting; unit automatically halts when timer reaches zero with audible alert .
  • Operation Mode Selection: Select continuous operation (no timer) or timed operation via control interface .
  • Load Balancing: Distribute vessels evenly across work platform; do not exceed maximum load capacity (10 kg) .
  • Cold Room/Incubator Use: Unit can be placed in cold rooms (5-40°C) or standard incubators for temperature-sensitive applications .
  • Spill Management: If liquid spills onto unit, disconnect power immediately, clean thoroughly, allow to dry before reuse .
  • Maintenance: Brushless DC motor requires minimal maintenance; keep unit clean and dry .

6. LABORATORY & CLINICAL APPLICATIONS

  • Primary Application: Large-capacity see-saw rocking mixing for electrophoresis gel staining/destaining, Western blot membrane washing, DNA hybridization, immunoprecipitation, cell culture, and general sample preparation in high-volume clinical diagnostic, molecular biology, and research laboratories .
  • Clinical Role: Essential high-capacity mixing equipment in clinical diagnostic laboratories, molecular biology labs, immunology laboratories, pharmaceutical research laboratories, and academic research institutions with high-throughput testing requirements .
SAFETY HANDLING PRECAUTIONS

1. SAFETY PRECAUTIONS

  • Electrical Safety: Disconnect power before cleaning; do not immerse unit in liquid; keep power cord away from heat sources .
  • Load Limits: Do not exceed maximum load capacity (10 kg); ensure load is evenly distributed across work platform to prevent imbalance .
  • Spill Protection: Use appropriate vessel caps or seals to prevent sample leakage; clean spills immediately .
  • Speed Selection: Select appropriate speed for sample type (10-70 rpm); use lower speeds (10-30 rpm) for delicate membrane washing steps and cell cultures; use higher speeds (40-70 rpm) for gel destaining solutions .
  • Cold Room/Incubator Use: Ensure instrument is placed on stable surface within cold room or incubator; operating temperature range 5-40°C; permissible ambient humidity ≤80% RH .
  • Timer Use: Set appropriate time for mixing protocol; do not exceed recommended mixing times for sensitive samples; unit automatically halts when timer reaches zero .
  • Platform Cleaning: Clean work platform regularly to prevent residue buildup and maintain vessel stability .
  • Accessory Installation: Ensure optional platforms or clamps are securely attached before loading samples .
  • Training: Only trained laboratory personnel should operate the SK-R330-Pro for clinical diagnostic applications .

2. FIRST AID MEASURES

  • Sample Splash: If biological sample splashes into eyes, flush with water for 15 minutes, seek medical attention; if on skin, wash with soap and water .
  • Electrical Malfunction: If unit shows signs of electrical malfunction (smoke, burning smell), disconnect power immediately; do not attempt to operate; contact service personnel .
  • Mechanical Failure: If unit fails to operate or makes abnormal noise, disconnect power, check for obstruction, contact service if issue persists .
  • Overload Shutdown: If unit shuts down due to overload, reduce load weight, distribute load evenly, and restart .
  • Chemical Spill: If corrosive chemicals spill on unit, disconnect power immediately, wipe with appropriate neutralizer, dry thoroughly before reconnecting power .

3. FIRE FIGHTING MEASURES

  • Flammability: Plastic housing and electrical components may burn .
  • Extinguishing Media: Use carbon dioxide (CO₂) or dry chemical extinguisher for electrical fires .
  • Fire Response: Unplug unit immediately; do not use water on electrical fire .